메뉴 건너뛰기




Volumn 27, Issue 6, 2012, Pages 2813-2824

Transient control of DFIG-based wind power plants in compliance with the australian grid code

Author keywords

Australian Grid Code; doubly fed induction generator (DFIG) based wind power plants; P Q capability curves

Indexed keywords

CAPABILITY CURVES; CONTROL SCHEMES; CONVENTIONAL PI; CURRENT CONTROL LOOP; CURRENT REGULATORS; DOUBLY FED INDUCTION GENERATOR (DFIG); GRID CODES; HIGH-VOLTAGES; NEW DESIGN; POWER CONTROL LOOPS; POWER RECOVERY; REACTIVE POWER CAPABILITY; REACTIVE POWER SUPPORT; RIDE-THROUGH; RIDETHROUGH CAPABILITY; STRINGENT REGULATIONS; SUPPLY VOLTAGES; TIME-DOMAIN SIMULATIONS; VERY FAST TRANSIENTS; WIND GENERATOR SYSTEMS;

EID: 84859060081     PISSN: 08858993     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPEL.2011.2174380     Document Type: Article
Times cited : (123)

References (34)
  • 1
    • 84859079037 scopus 로고    scopus 로고
    • IEA, 2009 IEA wind annual report (May). [Online], Available at
    • IEA, 2009 IEA wind annual report (May 2010). [Online]. Available at http://www.ieawind.org
    • (2010)
  • 2
    • 84859031589 scopus 로고    scopus 로고
    • Australian Government Enhanced Renewable Energy Target (Sep.). [Online]., Available at
    • Australian Government, Enhanced Renewable Energy Target (Sep. 2010). [Online]. Available at http://www.climatechange.gov.au
    • (2010)
  • 3
    • 70349579256 scopus 로고    scopus 로고
    • A review of grid code technical requirements for wind farms
    • Sep.
    • M. Tsili and S. Papathanassiou, "A review of grid code technical requirements for wind farms," IET Renew. Power Gener., vol. 3, no. 3, pp. 308-332, Sep. 2009.
    • (2009) IET Renew. Power Gener. , vol.3 , Issue.3 , pp. 308-332
    • Tsili, M.1    Papathanassiou, S.2
  • 4
    • 84859087410 scopus 로고    scopus 로고
    • Transpower, Generator fault ride through (FRT) investigation (Feb. 2009)
    • Transpower, Generator fault ride through (FRT) investigation (Feb. 2009).
  • 5
    • 84859031592 scopus 로고    scopus 로고
    • [Online]. Available
    • [Online]. Available: www.electricitycommission.govt.nz
  • 6
    • 28244480269 scopus 로고    scopus 로고
    • Control of DFIG-based wind generation for power network support
    • DOI 10.1109/TPWRS.2005.857275
    • F. M. Hughes, O. A. Lara, N. Jenkins, and G. Strbac, "Control of DFIG based wind generation for power network support," IEEE Trans. Power Syst., vol. 20, no. 4, pp. 1958-1966, Nov. 2005. (Pubitemid 41700549)
    • (2005) IEEE Transactions on Power Systems , vol.20 , Issue.4 , pp. 1958-1966
    • Hughes, F.M.1    Anaya-Lara, O.2    Jenkins, N.3    Strbac, G.4
  • 8
    • 69449085926 scopus 로고    scopus 로고
    • A review of the state of the art of power electronics for wind turbines
    • Aug.
    • Z. Chen, J. M. Guerrero, and F. Blaabjerg, "A review of the state of the art of power electronics for wind turbines," IEEE Trans. Power Electron., vol. 24, no. 8, pp. 1859-1875, Aug. 2009.
    • (2009) IEEE Trans. Power Electron. , vol.24 , Issue.8 , pp. 1859-1875
    • Chen, Z.1    Guerrero, J.M.2    Blaabjerg, F.3
  • 9
    • 36348950411 scopus 로고    scopus 로고
    • Voltage and transient stability support by wind farms complying with the E.ON netz grid code
    • DOI 10.1109/TPWRS.2007.907523
    • N. R. Ullah, T. Thiringer, and D. Karlsson, "Voltage and transient stability support by wind farms complying with the E.ON Netz grid code," IEEE Trans. Power Syst., vol. 22, no. 4, pp. 1647-1656, Nov. 2007. (Pubitemid 350141963)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.4 , pp. 1647-1656
    • Ullah, N.R.1    Thiringer, T.2    Karlsson, D.3
  • 10
    • 76649130518 scopus 로고    scopus 로고
    • A variable speed wind turbine control strategy to meet wind farm grid code requirements
    • Feb.
    • S. M. Muyeen, R. Takahashi, T. Murata, and J. Tamura, "A variable speed wind turbine control strategy to meet wind farm grid code requirements," IEEE Trans. Power Syst., vol. 25, no. 1, pp. 331-340, Feb. 2010.
    • (2010) IEEE Trans. Power Syst. , vol.25 , Issue.1 , pp. 331-340
    • Muyeen, S.M.1    Takahashi, R.2    Murata, T.3    Tamura, J.4
  • 11
    • 34248592638 scopus 로고    scopus 로고
    • Processing of symmetrical components in time-domain
    • DOI 10.1109/TPWRS.2007.894860
    • M. Karimi-Ghartemani and H. Karimi, "Processing of symmetrical components in time-domain," IEEE Trans. Power Syst., vol. 22, no. 2, pp. 572-579, May 2007. (Pubitemid 46746218)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.2 , pp. 572-579
    • Karimi-Ghartemani, M.1    Karimi, H.2
  • 12
    • 78650982805 scopus 로고    scopus 로고
    • Enhanced hysteresisbased current regulators in vector control of dfig wind turbines
    • Jan.
    • M. Mohseni, S. M. Islam, and M. A. S. Masoum, "Enhanced hysteresisbased current regulators in vector control of DFIG wind turbines," IEEE Trans. Power Electron., vol. 26, no. 1, pp. 223-234, Jan. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.1 , pp. 223-234
    • Mohseni, M.1    Islam, S.M.2    Masoum, M.A.S.3
  • 13
    • 80053064904 scopus 로고    scopus 로고
    • Impacts of symmetrical and asymmetrical voltage sags on dfig-based wind turbines considering phase-Angle jump, voltage recovery, and sag parameters
    • May
    • M. Mohseni, S. M. Islam, and M. A. S. Masoum, "Impacts of symmetrical and asymmetrical voltage sags on DFIG-based wind turbines considering phase-Angle jump, voltage recovery, and sag parameters," IEEE Trans. Power Electron., vol. 26, no. 5, pp. 1587-1598, May 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.5 , pp. 1587-1598
    • Mohseni, M.1    Islam, S.M.2    Masoum, M.A.S.3
  • 14
    • 20544451598 scopus 로고    scopus 로고
    • Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip
    • DOI 10.1109/TEC.2005.845526
    • J. Morren and S. W. H. de Haan, "Ride-through of wind turbines with doubly fed induction generator during a voltage dip," IEEE Trans. Energy Convers., vol. 20, no. 2, pp. 435-441, Jun. 2005. (Pubitemid 40843745)
    • (2005) IEEE Transactions on Energy Conversion , vol.20 , Issue.2 , pp. 435-441
    • Morren, J.1    De Haan, S.W.H.2
  • 15
    • 33947430524 scopus 로고    scopus 로고
    • Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    • DOI 10.1109/TEC.2006.875783
    • D. Xiang, L. Ran, P. Tavner, and S. Yang, "Control of a doubly fed induction generator in a wind turbine during grid fault ride through," IEEE Trans. Energy Convers., vol. 21, no. 3, pp. 652-662, Sep. 2006. (Pubitemid 46445154)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.3 , pp. 652-662
    • Xiang, D.1    Ran, L.2    Tavner, P.J.3    Yang, S.4
  • 16
    • 80053055155 scopus 로고    scopus 로고
    • Fault ride-through capability enhancement for doubly fed induction wind generators
    • Sep.
    • MMohseni, M. A. S. Masoum, and S. Islam, "Fault ride-through capability enhancement for doubly fed induction wind generators," IET Renew. Power Gener., vol. 5, no. 5, pp. 368-378, Sep. 2011.
    • (2011) IET Renew. Power Gener. , vol.5 , Issue.5 , pp. 368-378
    • Mohseni, M.1    Masoum, M.A.S.2    Islam, S.3
  • 17
    • 44449177025 scopus 로고    scopus 로고
    • A fault tolerant doubly fed induction generator wind turbine using a parallel grid side rectifier and series grid side converter
    • May
    • P. S. Flannery and G. Venkataramanan, "A fault tolerant doubly fed induction generator wind turbine using a parallel grid side rectifier and series grid side converter," IEEE Trans. Power Electron., vol. 23, no. 3, pp. 1126-1134, May 2008.
    • (2008) IEEE Trans. Power Electron. , vol.23 , Issue.3 , pp. 1126-1134
    • Flannery, P.S.1    Venkataramanan, G.2
  • 18
    • 34548019038 scopus 로고    scopus 로고
    • Modeling of wind turbines based on doubly-fed induction generators for power system stability studies
    • DOI 10.1109/TPWRS.2007.901607
    • I. Erlich, J. Kretschmann, J. Fortmann, S. M. Engelhardt, and H. Wrede, "Modeling of wind turbines based on doubly-fed induction generators for power system stability studies," IEEE Trans. Power Syst., vol. 22, no. 3, pp. 909-919, Aug. 2007. (Pubitemid 47278350)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.3 , pp. 909-919
    • Erlich, I.1    Kretschmann, J.2    Fortmann, J.3    Mueller-Engelhardt, S.4    Wrede, H.5
  • 19
    • 44449131797 scopus 로고    scopus 로고
    • An improved control strategy of limiting the DC-link voltage fluctuation for a doubly fed induction wind generator
    • DOI 10.1109/TPEL.2008.921177
    • J. Yao, H. Li, Y. Liao, and Z. Chen, "An improved control strategy of limiting the DC-link voltage fluctuation for a doubly fed induction wind generator," IEEE Trans. Power Electron., vol. 23, no. 3, pp. 1205-1213, May 2008. (Pubitemid 351756696)
    • (2008) IEEE Transactions on Power Electronics , vol.23 , Issue.3 , pp. 1205-1213
    • Yao, J.1    Li, H.2    Liao, Y.3    Chen, Z.4
  • 21
    • 79956080320 scopus 로고    scopus 로고
    • Low and high voltage ride-through of dfig wind turbines using hybrid current controlled converters
    • Jul.
    • M. Mohseni, M. A. S. Masoum, and S. M. Islam, "Low and high voltage ride-through of DFIG wind turbines using hybrid current controlled converters," Electr. Power Syst. Res., vol. 81, no. 7, pp. 1456-1465, Jul. 2011.
    • (2011) Electr. Power Syst. Res. , vol.81 , Issue.7 , pp. 1456-1465
    • Mohseni, M.1    Masoum, M.A.S.2    Islam, S.M.3
  • 22
    • 34249792921 scopus 로고    scopus 로고
    • Reactive power control strategies for DFIG-based plants
    • DOI 10.1109/TEC.2006.874215
    • M. Kayikci and J. Milanovic, "Reactive power control strategies for DFIG based plants," IEEE Trans. Energy Convers., vol. 22, no. 2, pp. 389-396, Jun. 2007. (Pubitemid 46845638)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.2 , pp. 389-396
    • Kayikci, M.1    Milanovic, J.V.2
  • 23
    • 79951955324 scopus 로고    scopus 로고
    • Reactive power capability of wind turbines based on doubly fed induction generators
    • Mar.
    • S. Engelhardt, I. Erlich, C. Feltes, J. Kretschmann, and F. Shewarega, "Reactive power capability of wind turbines based on doubly fed induction generators," IEEE Trans. Energy Convers., vol. 26, no. 1, pp. 364-372, Mar. 2011.
    • (2011) IEEE Trans. Energy Convers. , vol.26 , Issue.1 , pp. 364-372
    • Engelhardt, S.1    Erlich, I.2    Feltes, C.3    Kretschmann, J.4    Shewarega, F.5
  • 24
    • 68349150881 scopus 로고    scopus 로고
    • Extended reactive capability of dfig wind parks for enhanced system performance
    • Aug.
    • R. J. Konopinski, P. Vijayan, and V. Ajjarapu, "Extended reactive capability of DFIG wind parks for enhanced system performance," IEEE Trans. Power Syst., vol. 24, no. 3, pp. 1346-1355, Aug. 2009.
    • (2009) IEEE Trans. Power Syst. , vol.24 , Issue.3 , pp. 1346-1355
    • Konopinski, R.J.1    Vijayan, P.2    Ajjarapu, V.3
  • 25
    • 84859031597 scopus 로고    scopus 로고
    • AEMC National Electricity Rules Version 39 (Sep.). [Online]. Available at
    • AEMC, National Electricity Rules, Version 39 (Sep. 2010). [Online]. Available at http://www.aemc.gov.au/
    • (2010)
  • 26
    • 84859031596 scopus 로고    scopus 로고
    • Semikron, semistakwind/solar (mar.). [online]. Available at
    • Semikron, SEMISTAKWind/Solar (Mar. 2010). [Online].Available at http://www.semikron.com/
    • (2010)
  • 27
    • 8744298400 scopus 로고    scopus 로고
    • Comparison between statorflux and grid flux oriented rotor current control of doubly-fed induction generators," in
    • A. Peterson, L. Harnefors, and T. Thiringer, "Comparison between statorflux and grid flux oriented rotor current control of doubly-fed induction generators," in Proc. 35th IEEE Power Electron. Spec. Conf., 2004, pp. 482-486.
    • (2004) Proc. 35th IEEE Power Electron. Spec. Conf. , pp. 482-486
    • Peterson, A.1    Harnefors, L.2    Thiringer, T.3
  • 28
    • 76649127421 scopus 로고    scopus 로고
    • Rotor voltage dynamics in the doubly fed induction generator during grid faults
    • Jan.
    • F. K. A. Lima, A. Luna, P. Rodriguez, E. H. Watanabe, and F. Blaabjerg, "Rotor voltage dynamics in the doubly fed induction generator during grid faults," IEEE Trans. Power Electron., vol. 25, no. 1, pp. 118-130, Jan. 2010.
    • (2010) IEEE Trans. Power Electron. , vol.25 , Issue.1 , pp. 118-130
    • Lima, F.K.A.1    Luna, A.2    Rodriguez, P.3    Watanabe, E.H.4    Blaabjerg, F.5
  • 29
    • 0030643536 scopus 로고    scopus 로고
    • Operation of a phase locked loop system under distorted utility conditions
    • Jan./Feb.
    • V. Kaura and V. Blasko, "Operation of a phase locked loop system under distorted utility conditions," IEEE Trans. Ind. Appl., vol. 33, no. 1, pp. 58-63, Jan./Feb. 1997.
    • (1997) IEEE Trans. Ind. Appl. , vol.33 , Issue.1 , pp. 58-63
    • Kaura, V.1    Blasko, V.2
  • 30
    • 77956904293 scopus 로고    scopus 로고
    • A new vector-based hysteresis current control scheme for three-phase pwm voltage-source inverters
    • Sep.
    • M. Mohseni and S. M. Islam, "A new vector-based hysteresis current control scheme for three-phase PWM voltage-source inverters," IEEE Trans. Power Electron., vol. 25, no. 9, pp. 2299-2309, Sep. 2010.
    • (2010) IEEE Trans. Power Electron. , vol.25 , Issue.9 , pp. 2299-2309
    • Mohseni, M.1    Islam, S.M.2
  • 31
    • 0032188509 scopus 로고    scopus 로고
    • Current control techniques for three-phase voltage-source pwm converters: A survey
    • PII S0278004698070154
    • M. P. Kazmierkowski and L. Malesani, "Current control techniques for three-phase voltage-sourcePWMconverters: A survey," IEEE Trans. Ind. Electron., vol. 45, no. 5, pp. 691-703, Oct. 1998. (Pubitemid 128740289)
    • (1998) IEEE Transactions on Industrial Electronics , vol.45 , Issue.5 , pp. 691-703
    • Kazmierkowski, M.P.1    Malesani, L.2
  • 34
    • 84859079046 scopus 로고    scopus 로고
    • SKM, New generation technologies and GB grid codes, Dec., [Online]. Available at
    • SKM, New generation technologies and GB grid codes (Dec. 2004). [Online]. Available at http://www.ofgem.gov.uk/
    • (2004)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.