메뉴 건너뛰기




Volumn 25, Issue 3, 2010, Pages 836-843

Feed-forward transient current control for low-voltage ride-through enhancement of DFIG wind turbines

Author keywords

Doubly fed induction generator (DFIG); Low voltage ride through (LVRT); Transient current control; Wind turbines

Indexed keywords

AC-SIDE; ACTIVE AND REACTIVE POWER; COMPUTATIONAL EFFORT; CONTROL SCHEMES; CONVENTIONAL CURRENTS; DOUBLY FED INDUCTION GENERATORS; DOUBLY-FED INDUCTION GENERATOR; ELECTRICAL POWER GENERATION; FEED-FORWARD; INDUCED VOLTAGES; LOW-VOLTAGE RIDE-THROUGH; OUTPUT VOLTAGES; POWER GRIDS; ROTOR CURRENT; ROTOR-SIDE CONVERTER; SIMULATION RESULT; THREE PHASE FAULTS; TRANSIENT CURRENT; TRANSIENT CURRENT CONTROL; WIND ENERGY GENERATION;

EID: 77956032032     PISSN: 08858969     EISSN: None     Source Type: Journal    
DOI: 10.1109/TEC.2010.2048033     Document Type: Article
Times cited : (248)

References (20)
  • 1
    • 67649655884 scopus 로고    scopus 로고
    • Grid connection requirements and solutions for DFIG wind turbines
    • Atlanta, GA, Nov. 17-18
    • W. Qiao and R. G. Harley, "Grid connection requirements and solutions for DFIG wind turbines," in Proc. IEEE Energy 2030 Conf., Atlanta, GA, Nov. 17-18, 2008, pp. 1-8.
    • (2008) Proc. IEEE Energy 2030 Conf. , pp. 1-8
    • Qiao, W.1    Harley, R.G.2
  • 2
    • 77956019719 scopus 로고    scopus 로고
    • (2005, Jun. 2). Regulatory Order No. 661: Interconnection for Wind Energy [Online]. Available:
    • Federal Energy Regulatory Commission. (2005, Jun. 2). Regulatory Order No. 661: Interconnection for Wind Energy [Online]. Available: http://www.ferc.gov/industries/electric/indus-act/gi/wind.asp
  • 3
    • 77956044711 scopus 로고    scopus 로고
    • Dec. 12). Regulatory Order No. 661-A: Interconnection for Wind Energy [Online]. Available
    • Federal Energy Regulatory Commission. (2005, Dec. 12). Regulatory Order No. 661-A: Interconnection for Wind Energy [Online]. Available: http://www.ferc.gov/industries/electric/indus-act/gi/wind.asp
    • (2005)
  • 4
    • 34548274089 scopus 로고    scopus 로고
    • Dynamic behavior of the doubly fed induction generator during three-phase voltage dips
    • Sep.
    • J. Lopez, P. Sanchis, X. Roboam, and L. Marroyo, "Dynamic behavior of the doubly fed induction generator during three-phase voltage dips," IEEE Trans. Energy Convers., vol.22, no.3, pp. 709-717, Sep. 2007.
    • (2007) IEEE Trans. Energy Convers. , vol.22 , Issue.3 , pp. 709-717
    • Lopez, J.1    Sanchis, P.2    Roboam, X.3    Marroyo, L.4
  • 5
    • 20544451598 scopus 로고    scopus 로고
    • Ride through of wind turbines with doubly-fed induction generator during a voltage dip
    • Jun.
    • J. Morren and S. W. H. de Hann, "Ride through of wind turbines with doubly-fed induction generator during a voltage dip," IEEE Trans. Energy Convers., vol.20, no.2, pp. 435-441, Jun. 2005.
    • (2005) IEEE Trans. Energy Convers. , vol.20 , Issue.2 , pp. 435-441
    • Morren, J.1    De Hann, S.W.H.2
  • 6
    • 34748865378 scopus 로고    scopus 로고
    • Dynamic behavior of DFIG-based wind turbines during grid faults
    • Nagoya, Japan, Apr. 2-5
    • I. Erlich, H. Wrede, and C. Feltes, "Dynamic behavior of DFIG-based wind turbines during grid faults," in Proc. Power Convers. Conf. (PCC 2007), Nagoya, Japan, Apr. 2-5, pp. 1195-1200.
    • (2007) Proc. Power Convers. Conf. (PCC) , pp. 1195-1200
    • Erlich, I.1    Wrede, H.2    Feltes, C.3
  • 7
    • 59649114419 scopus 로고    scopus 로고
    • Real-time implementation of a STATCOM on a wind farm equipped with doubly fed induction generators
    • Jan./Feb.
    • W. Qiao, G. K. Venayagamoorthy, and R. G. Harley, "Real-time implementation of a STATCOM on a wind farm equipped with doubly fed induction generators," IEEE Trans. Ind. Appl., vol.45, no.1, pp. 98-107, Jan./Feb. 2009.
    • (2009) IEEE Trans. Ind. Appl. , vol.45 , Issue.1 , pp. 98-107
    • Qiao, W.1    Venayagamoorthy, G.K.2    Harley, R.G.3
  • 8
    • 67349139918 scopus 로고    scopus 로고
    • Coordinated reactive power control of a large wind farm and a STATCOM using heuristic dynamic programming
    • Jun.
    • W.Qiao,R.G.Harley, andG.K.Vanayagamoorthy, "Coordinated reactive power control of a large wind farm and a STATCOM using heuristic dynamic programming," IEEE Trans. Energy Convers., vol.24, no.2, pp. 493-503, Jun. 2009.
    • (2009) IEEE Trans. Energy Convers. , vol.24 , Issue.2 , pp. 493-503
    • Qiao, W.1    Harley, R.G.2    Vanayagamoorthy, G.K.3
  • 9
    • 34249879255 scopus 로고    scopus 로고
    • Supercapacitor energy storage for wind energy applications
    • May/Jun.
    • C. Abbey and G. Joos, "Supercapacitor energy storage for wind energy applications," IEEE Trans. Ind. Appl., vol.43, no.3, pp. 769-776, May/Jun. 2007.
    • (2007) IEEE Trans. Ind. Appl. , vol.43 , Issue.3 , pp. 769-776
    • Abbey, C.1    Joos, G.2
  • 10
    • 44449177025 scopus 로고    scopus 로고
    • Afault tolerant doubly fed induction generator wind turbine using a parallel grid side rectifier and series grid side converter
    • May
    • P. Flannery andG.Venkataramanan, "Afault tolerant doubly fed induction generator wind turbine using a parallel grid side rectifier and series grid side converter," IEEE Trans. Power Electron., vol.23, no.3, pp. 1126- 1135, May 2008.
    • (2008) IEEE Trans. Power Electron. , vol.23 , Issue.3 , pp. 1126-1135
    • Flannery, P.1    Venkataramanan, G.2
  • 11
    • 77951998912 scopus 로고    scopus 로고
    • A dynamic LVRT solution for doublyfed induction generators
    • Jan.
    • O. Abdel-Baqi and A. Nasiri, "A dynamic LVRT solution for doublyfed induction generators," IEEE Trans. Power Electron., vol.25, no.1, pp. 193-196, Jan. 2010.
    • (2010) IEEE Trans. Power Electron. , vol.25 , Issue.1 , pp. 193-196
    • Abdel-Baqi, O.1    Nasiri, A.2
  • 12
    • 33947430524 scopus 로고    scopus 로고
    • Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    • Sep.
    • D. Xiang, L. Ran, P. J. Tavner, and S. Yang, "Control of a doubly fed induction generator in a wind turbine during grid fault ride-through," IEEE Trans. Energy Convers., vol.21, no.3, pp. 652-662, Sep. 2006.
    • (2006) IEEE Trans. Energy Convers. , vol.21 , Issue.3 , pp. 652-662
    • Xiang, D.1    Ran, L.2    Tavner, P.J.3    Yang, S.4
  • 14
    • 0003561046 scopus 로고    scopus 로고
    • London U.K.: Oxford University Press 2000, ISBN-10: 0198564392/ISBN-13: 978-0198564393
    • D. W. Novotny and T. A. Lipo, Vector Control and Dynamics of AC Drives. London, U.K.: Oxford University Press, 2000, ISBN-10: 0198564392/ISBN-13: 978-0198564393.
    • Vector Control and Dynamics of AC Drives
    • Novotny, D.W.1    Lipo, T.A.2
  • 15
    • 44449152969 scopus 로고    scopus 로고
    • Wind speed estimation based sensorless output maximization control for a wind turbine driving a DFIG
    • May
    • W. Qiao,W. Zhou, J. M. Aller, and R. G. Harley, "Wind speed estimation based sensorless output maximization control for a wind turbine driving a DFIG," IEEE Trans. Power Electron., vol.23, no.3, pp. 1156-1169, May 2008.
    • (2008) IEEE Trans. Power Electron. , vol.23 , Issue.3 , pp. 1156-1169
    • Qiaow. Zhou, W.1    Aller, J.M.2    Harley, R.G.3
  • 16
    • 0023255132 scopus 로고
    • Performance of feedforward current regulators for field-oriented induction machine controllers
    • Jul./Aug.
    • R. Lorenz andD. Lawson, "Performance of feedforward current regulators for field-oriented induction machine controllers," IEEE Trans. Ind. Appl., vol.IA-23, no.4, pp. 597-602, Jul./Aug. 1987.
    • (1987) IEEE Trans. Ind. Appl. , vol.IA-23 , Issue.4 , pp. 597-602
    • Lorenz, R.1    Lawson, D.2
  • 17
    • 1542359447 scopus 로고    scopus 로고
    • Dynamic modeling of GE 1.5 and 3.6 MW wind turbine-generators for stability simulations
    • Toronto, ON, Canada, Jul. 13-17
    • N. Miller, J. Sanchez-Gasca,W. Price, and R. Delmerico, "Dynamic modeling of GE 1.5 and 3.6 MW wind turbine-generators for stability simulations," in Proc. IEEE PES Gen. Meeting, Toronto, ON, Canada, Jul. 13-17, 2003, pp. 1977-1983.
    • (2003) Proc. IEEE PES Gen. Meeting , pp. 1977-1983
    • Miller, N.1    Sanchez-Gasca, W.2    Price, J.3    Delmerico, R.4
  • 18
    • 33847646777 scopus 로고    scopus 로고
    • Ride-through analysis of doubly fed induction wind-power generator under unsymmetrical network disturbance
    • Nov.
    • S. Seman, J. Niiranen, and A. Arkkio, "Ride-through analysis of doubly fed induction wind-power generator under unsymmetrical network disturbance," IEEE Trans. Power Syst., vol.21, no.4, pp. 1782-1789, Nov. 2006.
    • (2006) IEEE Trans. Power Syst. , vol.21 , Issue.4 , pp. 1782-1789
    • Seman, S.1    Niiranen, J.2    Arkkio, A.3
  • 19
    • 33847726725 scopus 로고    scopus 로고
    • Simulation of doubly fed induction generator wind turbine with an active crowbar
    • presented at Riga, Latvia, Sep.
    • J. Niiranen, "Simulation of doubly fed induction generator wind turbine with an active crowbar," presented at the 11th Int. Conf. Power Electronics and Motion Control (EPE-PEMC 2004), Riga, Latvia, Sep. 2-4.
    • (2004) The 11th Int. Conf. Power Electronics and Motion Control (EPE-PEMC) , pp. 2-4
    • Niiranen, J.1
  • 20
    • 33847371286 scopus 로고    scopus 로고
    • Fault ride-through capability of DFIG wind turbines
    • Jul.
    • A. Hansen and G.Michalke, "Fault ride-through capability of DFIG wind turbines," Renewable Energy, vol.32, no.9, pp. 1594-1610, Jul. 2007.
    • (2007) Renewable Energy , vol.32 , Issue.9 , pp. 1594-1610
    • Hansen, A.1    Michalke, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.