메뉴 건너뛰기




Volumn 26, Issue 4, 2011, Pages 1161-1171

Modeling and ride-through control of doubly fed induction generators during symmetrical voltage sags

Author keywords

Doubly fed induction generator (DFIG); low voltage ride through capability (LVRT); voltage sags and wind conversion systems

Indexed keywords

DOUBLY FED INDUCTION GENERATORS; DOUBLY-FED INDUCTION GENERATOR; FREQUENCY DOMAINS; GRID CODES; GRID DISTURBANCE; LOW-VOLTAGE RIDE-THROUGH; MAGNETIZING CURRENT; NEW STRATEGY; RIDE-THROUGH CONTROL; SYSTEM RESPONSE; THEORETICAL BASIS; VOLTAGE SAGS; WIND ENERGY CONVERSION SYSTEM; WIND GENERATION;

EID: 82155162497     PISSN: 08858969     EISSN: None     Source Type: Journal    
DOI: 10.1109/TEC.2011.2163718     Document Type: Article
Times cited : (93)

References (26)
  • 1
    • 27144501549 scopus 로고    scopus 로고
    • Grid code requirements concerning connection and operation Of wind turbines in Germany
    • 2005 IEEE Power Engineering Society General Meeting
    • I. Erlich and U. Bachmann, "Grid code requirements concerning connection and operation of wind turbines in Germany," in Proc. IEEE Power Eng. Soc. General Meeting, Jun. 2005, vol. 2, pp. 1253-1257. (Pubitemid 41497113)
    • (2005) 2005 IEEE Power Engineering Society General Meeting , vol.2 , pp. 1253-1257
    • Erlich, I.1    Bachmann, U.2
  • 3
    • 20444427743 scopus 로고    scopus 로고
    • E.ON Netz GmbH, Bayreuth Germany Apr. [Online]
    • E.ON Netz GmbH, Bayreuth, Germany. (2006, Apr.). Grid Code High and Extra High Voltage, [Online]. Available: http://www.eon-netz.com
    • (2006) Grid Code High and Extra High Voltage
  • 4
    • 78650386152 scopus 로고    scopus 로고
    • Overview of FACTS devices for wind power plants directly connected to the transmission network
    • Jul.
    • A. Adamczyk, R. Teodorescu, R. N. Mukerjee, and P. Rodriguez, "Overview of FACTS devices for wind power plants directly connected to the transmission network," in Proc. IEEE Int. Symp. Ind. Electron., Jul. 2010, pp. 3742-3748.
    • (2010) Proc. IEEE Int. Symp. Ind. Electron. , pp. 3742-3748
    • Adamczyk, A.1    Teodorescu, R.2    Mukerjee, R.N.3    Rodriguez, P.4
  • 6
    • 34548274089 scopus 로고    scopus 로고
    • Dynamic behavior of the doubly fed induction generator during three-phase voltage dips
    • DOI 10.1109/TEC.2006.878241
    • J. Ĺopez, P. Sanchis, X. Roboam, and L. Marroyo, "Dynamic behavior of the doubly fed induction generator during three-phase voltage dips," IEEE Trans. Energy Convers., vol. 22, no. 3, pp. 709-717, Sep. 2007. (Pubitemid 47323587)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.3 , pp. 709-717
    • Lopez, J.1    Sanchis, P.2    Roboam, X.3    Marroyo, L.4
  • 7
    • 35048853522 scopus 로고    scopus 로고
    • Performance study of a doubly fed wind-power induction generator under network disturbances
    • DOI 10.1109/TEC.2005.853741
    • S. Seman, J. Niiranen, S. Karneva, A. Arkkion, and J. Saitz, "Performance study of a doubly fed wind power induction generator under network disturbances," IEEE Trans. Energy Convers., vol. 21, no. 4, pp. 883-890, Dec. 2006. (Pubitemid 44824173)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.4 , pp. 883-890
    • Seman, S.1    Niiranen, J.2    Kanerva, S.3    Arkkio, A.4    Saitz, J.5
  • 8
    • 84869982058 scopus 로고    scopus 로고
    • Dynamic responses of DFIG fault currents under constant AC exitation condition
    • L.-h. Zhang, X. Cai, and J.-h. Guo, "Dynamic responses of DFIG fault currents under constant AC exitation condition," in Proc. Power Energy Eng. Conf., 2009, pp. 1-4.
    • (2009) Proc. Power Energy Eng. Conf. , pp. 1-4
    • Zhang, L.-H.1    Cai, X.2    Guo, J.-H.3
  • 9
    • 20544451598 scopus 로고    scopus 로고
    • Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip
    • DOI 10.1109/TEC.2005.845526
    • J. Morren and S. W. H. de Haan, "Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip," IEEE Trans. Energy Convers., vol. 20, no. 2, pp. 435-441, Jun. 2005. (Pubitemid 40843745)
    • (2005) IEEE Transactions on Energy Conversion , vol.20 , Issue.2 , pp. 435-441
    • Morren, J.1    De Haan, S.W.H.2
  • 10
    • 77957014951 scopus 로고    scopus 로고
    • Decoupled-DFIG fault ridethrough strategy for enhanced stability performance during grid faults
    • Oct.
    • L. G. Meegahapola, T. Littler, and D. Flynn, "Decoupled-DFIG fault ridethrough strategy for enhanced stability performance during grid faults," IEEE Trans. Sustainable Energy, vol. 1 no. 3, pp. 152-132, Oct. 2010.
    • (2010) IEEE Trans. Sustainable Energy , vol.1 , Issue.3 , pp. 152-132
    • Meegahapola, L.G.1    Littler, T.2    Flynn, D.3
  • 11
    • 48449098817 scopus 로고    scopus 로고
    • An improved fault ride-through strategy for doubly fed induction generatorbased wind turbines
    • H. Kasem, E. F. El-Saadany, H. H. El-Tamaly, and M. A. A. Wahab, "An improved fault ride-through strategy for doubly fed induction generatorbased wind turbines," IET Renewable Power Generation, vol. 2, pp. 201-214, 2008.
    • (2008) IET Renewable Power Generation , vol.2 , pp. 201-214
    • Kasem, H.1    El-Saadany, E.F.2    El-Tamaly, H.H.3    Wahab, M.A.A.4
  • 12
    • 77952953407 scopus 로고    scopus 로고
    • A series-dynamic-resistor-based converter protection scheme for doubly-fed induction generator during various fault conditions
    • J. Yang, J. E. Fletcher, and J. O'Reilly, "A series-dynamic- resistor-based converter protection scheme for doubly-fed induction generator during various fault conditions," IEEE Trans. Energy Convers., vol. 25, pp. 422-432, 2010.
    • (2010) IEEE Trans. Energy Convers. , vol.25 , pp. 422-432
    • Yang, J.1    Fletcher, J.E.2    O'Reilly, J.3
  • 13
    • 77954555535 scopus 로고    scopus 로고
    • Efficient control scheme of wind turbines with doubly induction generators for low-voltage ride-through capability enhancement
    • M. Rahimi and M. Parniani, "Efficient control scheme of wind turbines with doubly induction generators for low-voltage ride-through capability enhancement," IET Renewable Power Generation, vol. 4, no. 3, pp. 242-252, 2010.
    • (2010) IET Renewable Power Generation , vol.4 , Issue.3 , pp. 242-252
    • Rahimi, M.1    Parniani, M.2
  • 15
    • 33947430524 scopus 로고    scopus 로고
    • Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    • DOI 10.1109/TEC.2006.875783
    • D. Xiang, L. Ran, P. J. Tavner, and S. Yang, "Control of doubly fed induction generator in a wind turbine during grid fault ride-through," IEEE Trans. Energy Convers., vol. 21, no. 3, pp. 652-662, Sep. 2006. (Pubitemid 46445154)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.3 , pp. 652-662
    • Xiang, D.1    Ran, L.2    Tavner, P.J.3    Yang, S.4
  • 16
    • 77956032032 scopus 로고    scopus 로고
    • Feed-forward transient current control for low-voltage ride-through enhancement of DFIG wind turbines
    • Sep.
    • J. Liang, W. Qiao, and R. G. Harley, "Feed-forward transient current control for low-voltage ride-through enhancement of DFIG wind turbines," IEEE Trans. Energy Convers., vol. 25, no. 3, pp. 836-843, Sep. 2010.
    • (2010) IEEE Trans. Energy Convers. , vol.25 , Issue.3 , pp. 836-843
    • Liang, J.1    Qiao, W.2    Harley, R.G.3
  • 17
    • 76649127421 scopus 로고    scopus 로고
    • Rotor voltage dynamics in the doubly fed induction generator during grid faults
    • Jan.
    • F. K. A. Lima, A. Luna, P. Rodriguez, E. H. Watanabe, and F. Blaabjerg, "Rotor voltage dynamics in the doubly fed induction generator during grid faults," IEEE Trans. Power Electron., vol. 25, no. 1, pp. 118-130, Jan. 2010.
    • (2010) IEEE Trans. Power Electron. , vol.25 , Issue.1 , pp. 118-130
    • Lima, F.K.A.1    Luna, A.2    Rodriguez, P.3    Watanabe, E.H.4    Blaabjerg, F.5
  • 18
    • 77952958302 scopus 로고    scopus 로고
    • Transient performance improvement of wind turbines with doubly fed induction generators using nonlinear control strategy
    • Jun.
    • M. Rahimi andM. Parniani, "Transient performance improvement of wind turbines with doubly fed induction generators using nonlinear control strategy," IEEE Trans. Energy Convers., vol. 25, no. 2, pp. 514-525, Jun. 2010.
    • (2010) IEEE Trans. Energy Convers. , vol.25 , Issue.2 , pp. 514-525
    • Rahimi, M.1    Parniani, M.2
  • 19
    • 33947613668 scopus 로고    scopus 로고
    • Control of a doubly fed induction wind generator under unbalanced grid voltage conditions
    • DOI 10.1109/TEC.2006.889550, Special Issue on Wind Power
    • T. K. A. Brekken and N. Mohan, "Control of a doubly-fed induction wind generator under unbalanced grid voltage conditions," IEEE Trans. Energy Convers., vol. 22, no. 1, pp. 129-135, Mar. 2007. (Pubitemid 46487485)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.1 , pp. 129-135
    • Brekken, T.K.A.1    Mohan, N.2
  • 20
    • 44449142859 scopus 로고    scopus 로고
    • Coordinated control of DFIG's rotor and grid side converters during network unbalance
    • DOI 10.1109/TPEL.2008.921157
    • L. Xu, "Coordinated control of DFIG's rotor and grid side converters during network unbalance," IEEE Trans. Power Electron., vol. 23, no. 3, pp. 1041-1049, May 2008. (Pubitemid 351756681)
    • (2008) IEEE Transactions on Power Electronics , vol.23 , Issue.3 , pp. 1041-1049
    • Xu, L.1
  • 21
    • 57749096905 scopus 로고    scopus 로고
    • Ride-through control of a doubly fed induction generator under unbalanced voltage sags
    • Dec.
    • O. Gomis-Bellmunt, A. Junyent-Ferre, A. Sumper, and J. BergasJane, "Ride-through control of a doubly fed induction generator under unbalanced voltage sags," IEEE Trans. Energy Convers., vol. 23, no. 4, pp. 1036-1045, Dec. 2008.
    • (2008) IEEE Trans. Energy Convers. , vol.23 , Issue.4 , pp. 1036-1045
    • Gomis-Bellmunt, O.1    Junyent-Ferre, A.2    Sumper, A.3    Bergas Jane, J.4
  • 22
    • 60449101280 scopus 로고    scopus 로고
    • Improved control of DFIG systems during network unbalance using PI-R current regulators
    • Feb.
    • J. Hu, Y. He, L. Xu, and B. W. Williams, "Improved control of DFIG systems during network unbalance using PI-R current regulators," IEEE Trans. Ind. Electron., vol. 56, no. 2, pp. 439-451, Feb. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.2 , pp. 439-451
    • Hu, J.1    He, Y.2    Xu, L.3    Williams, B.W.4
  • 23
    • 77957347759 scopus 로고    scopus 로고
    • DFIG wind generation systems operating with limited converter rating considered under unbalanced network conditions-Analysis and control design
    • J. Hu and Y. He, "DFIG wind generation systems operating with limited converter rating considered under unbalanced network conditions-Analysis and control design," Renewable Energy, vol. 36, no. 2, pp. 829-847, 2011.
    • (2011) Renewable Energy , vol.36 , Issue.2 , pp. 829-847
    • Hu, J.1    He, Y.2
  • 24
    • 70749090496 scopus 로고    scopus 로고
    • Reinforced control and operation of DFIG-based windpower-generation system under unbalanced grid voltage conditions
    • Dec.
    • J. Hu and Y. He, "Reinforced control and operation of DFIG-based windpower-generation system under unbalanced grid voltage conditions," IEEE Trans. Energy Convers., vol. 24, no. 4, pp. 905-915, Dec. 2009.
    • (2009) IEEE Trans. Energy Convers. , vol.24 , Issue.4 , pp. 905-915
    • Hu, J.1    He, Y.2
  • 26
    • 70349628410 scopus 로고    scopus 로고
    • Reactive power control design in doubly-fed induction generators for wind turbines
    • Oct.
    • B. C. Rabelo, Jr., W. Hofmann, R. G. de Oliveira, J. L. da Silva, and S. R. Silva, "Reactive power control design in doubly-fed induction generators for wind turbines," IEEE Trans. Ind. Electron., vol. 56, no. 10, pp. 4154-4162, Oct. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.10 , pp. 4154-4162
    • Rabelo Jr., B.C.1    Hofmann, W.2    De Oliveira, R.G.3    Da Silva, J.L.4    Silva, S.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.