메뉴 건너뛰기




Volumn 25, Issue 1, 2010, Pages 367-377

Coordinated control of DFIG and FSIG-based wind farms under unbalanced grid conditions

Author keywords

Doubly fed induction generator (DFIG); Fixed speed induction generator (FSIG); Stability; Unbalance; Wind power generation

Indexed keywords

CO-ORDINATED CONTROL; CONTROL STRATEGIES; DOUBLY-FED INDUCTION GENERATOR; FIXED SPEED INDUCTION GENERATOR; FIXED SPEED INDUCTION GENERATOR (FSIG); FIXED-SPEED INDUCTION GENERATORS; GRID CONDITIONS; GRID CONNECTIONS; MATLAB /SIMULINK; MECHANICAL STRESS; OUTPUT POWER FLUCTUATIONS; POWER ELECTRONIC INTERFACE; SIMULATION RESULT; STATOR WINDING; SYSTEM MODELS; TRANSMISSION NETWORKS; UNBALANCED VOLTAGES; WIND ENERGY SYSTEMS; WIND FARM;

EID: 73849090195     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2009.2033966     Document Type: Article
Times cited : (99)

References (25)
  • 1
    • 4544388007 scopus 로고    scopus 로고
    • Co-ordinated voltage control strategy for a doublyfed induction generator (DFIG)-based wind farm
    • Jul.
    • P. Cartwright, L. Holdsworth, J. B. Ekanayake, and N. Jenkins, "Co-ordinated voltage control strategy for a doublyfed induction generator (DFIG)-based wind farm," Proc. Inst. Elect. Eng., Gen. Transm. Distrib., vol. 151, no. 4, pp. 495-502, Jul. 2004.
    • (2004) Proc. Inst. Elect. Eng., Gen. Transm. Distrib. , vol.151 , Issue.4 , pp. 495-502
    • Cartwright, P.1    Holdsworth, L.2    Ekanayake, J.B.3    Jenkins, N.4
  • 2
    • 33846707953 scopus 로고    scopus 로고
    • Co-ordinated voltage control of DFIG wind turbines in uninterrupted operation during grid faults
    • Aug.
    • A. D. Hansen, G. Michalke, P. Sørensen, T. Lund, and F. Iov, "Co-ordinated voltage control of DFIG wind turbines in uninterrupted operation during grid faults," Wind Energy, vol. 10, pp. 51-68, Aug. 2006.
    • (2006) Wind Energy , vol.10 , pp. 51-68
    • Hansen, A.D.1    Michalke, G.2    Sørensen, P.3    Lund, T.4    Iov, F.5
  • 3
    • 28244480269 scopus 로고    scopus 로고
    • Control of DFIG-based wind generation for power network support
    • Nov.
    • F. M. Hughes, O. Anaya-Lara, N. Jenkins, and G. Strbac, "Control of DFIG-based wind generation for power network support," IEEE Trans. Power Syst., vol. 20, no. 4, pp. 1958-1966, Nov. 2005.
    • (2005) IEEE Trans. Power Syst. , vol.20 , Issue.4 , pp. 1958-1966
    • Hughes, F.M.1    Anaya-Lara, O.2    Jenkins, N.3    Strbac, G.4
  • 5
    • 0034224521 scopus 로고    scopus 로고
    • Control method comparison of doubly fed wind generators connected to the grid by asymmetric transmission lines
    • Jul./Aug.
    • S. D. Rubira and M. D. McCulloch, "Control method comparison of doubly fed wind generators connected to the grid by asymmetric transmission lines," IEEE Trans. Ind. Appl., vol. 36, no. 4, pp. 986-991, Jul./Aug. 2000.
    • (2000) IEEE Trans. Ind. Appl. , vol.36 , Issue.4 , pp. 986-991
    • Rubira, S.D.1    McCulloch, M.D.2
  • 6
    • 44349185745 scopus 로고    scopus 로고
    • Electrical equipment reliability evaluation at the voltage distortion and unbalance
    • Presented at the, Cracow, Poland, Sep. 21-23
    • I. V. Zhelezhenko, Y. L. Sayenko, and A. V. Gorpinich, "Electrical equipment reliability evaluation at the voltage distortion and unbalance," presented at the 8th Int. Conf. Electrical Power Quality Utilisation, Cracow, Poland, Sep. 21-23, 2005.
    • (2005) 8th Int. Conf. Electrical Power Quality Utilisation
    • Zhelezhenko, I.V.1    Sayenko, Y.L.2    Gorpinich, A.V.3
  • 7
    • 0035481879 scopus 로고    scopus 로고
    • Assessment of voltage unbalance
    • Oct.
    • A. von Jouanne and B. Banerjee, "Assessment of voltage unbalance," IEEE Trans. Power Del., vol. 16, no. 4, pp. 782-790, Oct. 2001.
    • (2001) IEEE Trans. Power Del. , vol.16 , Issue.4 , pp. 782-790
    • Von Jouanne, A.1    Banerjee, B.2
  • 8
    • 44349171306 scopus 로고    scopus 로고
    • Windings temperature and loss of life of an induction machine under voltage unbalance combined with over- or undervoltages
    • DOI 10.1109/TEC.2008.918596
    • P. Gnacinski, "Windings temperature and loss of life of an induction machine under voltage unbalance combined with over- or undervoltages," IEEE Trans. Energy Convers., vol. 23, no. 2, pp. 363-371, Jun. 2008. (Pubitemid 351728777)
    • (2008) IEEE Transactions on Energy Conversion , vol.23 , Issue.2 , pp. 363-371
    • Gnacinski, P.1
  • 9
    • 0000822733 scopus 로고    scopus 로고
    • STATCOM controls for operation with unbalanced voltage
    • Apr.
    • C. Hochgraf and R. H. Lasseter, "STATCOM controls for operation with unbalanced voltage," IEEE Trans. Power Del., vol. 13, no. 2, pp. 538-544, Apr. 1998.
    • (1998) IEEE Trans. Power Del. , vol.13 , Issue.2 , pp. 538-544
    • Hochgraf, C.1    Lasseter, R.H.2
  • 11
    • 0035674621 scopus 로고    scopus 로고
    • Mechanical stresses in fixed-speed wind turbines due to network disturbances
    • Dec.
    • S. A. Papathanassiou and M. P. Papadopoulos, "Mechanical stresses in fixed-speed wind turbines due to network disturbances," IEEE Trans. Energy Convers., vol. 16, no. 4, pp. 361-367, Dec. 2001.
    • (2001) IEEE Trans. Energy Convers. , vol.16 , Issue.4 , pp. 361-367
    • Papathanassiou, S.A.1    Papadopoulos, M.P.2
  • 13
    • 33947613668 scopus 로고    scopus 로고
    • Control of a doubly-fed induction wind generator under unbalanced grid voltage conditions
    • Mar.
    • T. K. A. Brekken and N. Mohan, "Control of a doubly-fed induction wind generator under unbalanced grid voltage conditions," IEEE Trans. Energy Convers., vol. 22, no. 1, pp. 129-135, Mar. 2007.
    • (2007) IEEE Trans. Energy Convers. , vol.22 , Issue.1 , pp. 129-135
    • Brekken, T.K.A.1    Mohan, N.2
  • 14
    • 0042658183 scopus 로고    scopus 로고
    • A novel doubly-fed induction wind generator control scheme for reactive power control and torque pulsation compensation under unbalanced grid voltage conditions
    • T. Brekken and N. Mohan, "A novel doubly-fed induction wind generator control scheme for reactive power control and torque pulsation compensation under unbalanced grid voltage conditions," in Proc. IEEE Power Eng. Soc. Conf., 2003, vol. 2, pp. 760-764.
    • (2003) Proc. IEEE Power Eng. Soc. Conf. , vol.2 , pp. 760-764
    • Brekken, T.1    Mohan, N.2
  • 15
    • 33947313847 scopus 로고    scopus 로고
    • Dynamic modeling and control of DFIG-based wind turbines under unbalanced network conditions
    • DOI 10.1109/TPWRS.2006.889113
    • L. Xu and Y. Wang, "Dynamic modeling and control of DFIG-based wind turbines under unbalanced network conditions," IEEE Trans. Power Syst., vol. 22, no. 1, pp. 314-323, Feb. 2007. (Pubitemid 46437741)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.1 , pp. 314-323
    • Xu, L.1    Wang, Y.2
  • 16
    • 35048877102 scopus 로고    scopus 로고
    • Control of DFIG-based wind generation systems under unbalanced network supply
    • DOI 10.1109/IEMDC.2007.382706, 4270679, Proceedings of 2007 IEEE International Electric Machines and Drives Conference, IEMDC 2007
    • Y. Wang and L. Xu, "Control of DFIG-based wind generation systems under unbalanced network supply," in Proc. Int. Electric Machines Drives Conf., May 2007, vol. 1, pp. 430-435. (Pubitemid 47553910)
    • (2007) Proceedings of IEEE International Electric Machines and Drives Conference, IEMDC 2007 , vol.1 , pp. 430-435
    • Wang, Y.1    Xu, L.2
  • 17
    • 33947320085 scopus 로고    scopus 로고
    • Methods for reduction of voltage unbalance in weak grids connected to wind plants
    • Presented at the, Oslo, Norway, Jun.
    • B. I. Nass, T. M. Undeland, and T. Gjengedal, "Methods for reduction of voltage unbalance in weak grids connected to wind plants," presented at the IEEE Workshop Wind Power Impacts Power Systems, Oslo, Norway, Jun. 2002.
    • (2002) IEEE Workshop Wind Power Impacts Power Systems
    • Nass, B.I.1    Undeland, T.M.2    Gjengedal, T.3
  • 18
    • 0004281784 scopus 로고    scopus 로고
    • 28th ed. New York: Industrial Press
    • E. Oberg et al., Machinery's Handbook, 28th ed. New York: Industrial Press, 2008.
    • (2008) Machinery's Handbook
    • Oberg, E.1
  • 19
    • 44449178272 scopus 로고    scopus 로고
    • A secondary voltage control strategy for transmission level interconnection of wind generation
    • May
    • M. E. Moursi, G. Joos, and C. Abbey, "A secondary voltage control strategy for transmission level interconnection of wind generation," IEEE Trans. Power Electron., vol. 23, no. 3, pp. 1178-1190, May 2008.
    • (2008) IEEE Trans. Power Electron. , vol.23 , Issue.3 , pp. 1178-1190
    • Moursi, M.E.1    Joos, G.2    Abbey, C.3
  • 20
    • 34249798182 scopus 로고    scopus 로고
    • Proportional-integral regulator- based approach to wind farm reactive power management for secondary voltage control
    • Jun.
    • G. Tapia, A. Tapia, and J. X. Ostolaza, "Proportional-integral regulator- based approach to wind farm reactive power management for secondary voltage control," IEEE Trans. Energy Convers., vol. 22, no. 2, pp. 488-498, Jun. 2007.
    • (2007) IEEE Trans. Energy Convers. , vol.22 , Issue.2 , pp. 488-498
    • Tapia, G.1    Tapia, A.2    Ostolaza, J.X.3
  • 21
    • 12544259253 scopus 로고    scopus 로고
    • VSC transmission operating under unbalanced AC conditions - Analysis and control design
    • DOI 10.1109/TPWRD.2004.835032
    • L. Xu, B. R. Andersen, and P. Cartwright, "VSC transmission operating under unbalanced ac conditions - Analysis and control design," IEEE Trans. Power Del., vol. 20, no. 1, pp. 427-434, Jan. 2005. (Pubitemid 40152079)
    • (2005) IEEE Transactions on Power Delivery , vol.20 , Issue.1 , pp. 427-434
    • Xu, L.1    Andersen, B.R.2    Cartwright, P.3
  • 22
    • 44449142859 scopus 로고    scopus 로고
    • Coordinated control of DFIG's rotor and grid side converters during network unbalance
    • May
    • L. Xu, "Coordinated control of DFIG's rotor and grid side converters during network unbalance," IEEE Trans. Power Electron., vol. 23, no. 3, pp. 1041-1049, May 2008.
    • (2008) IEEE Trans. Power Electron. , vol.23 , Issue.3 , pp. 1041-1049
    • Xu, L.1
  • 23
    • 42549152967 scopus 로고    scopus 로고
    • Control strategy for variablespeed, stall-regulated wind turbines
    • Philadelphia, PA, Jun.
    • E. Muljadi, K. Pierce, and P. Migliore, "Control strategy for variablespeed, stall-regulated wind turbines," in Proc. Amer. Controls Conf., Philadelphia, PA, Jun. 1998, vol. 3, pp. 1710-1714.
    • (1998) Proc. Amer. Controls Conf. , vol.3 , pp. 1710-1714
    • Muljadi, E.1    Pierce, K.2    Migliore, P.3
  • 25
    • 33744547370 scopus 로고    scopus 로고
    • Control scheme in hybrid synchronous stationary frame for PWM AC/DC converter under generalized unbalanced operating conditions
    • May/Jun.
    • Y. Suh and T. A. Lipo, "Control scheme in hybrid synchronous stationary frame for PWM AC/DC converter under generalized unbalanced operating conditions," IEEE Trans. Ind. Appl., vol. 42, no. 3, pp. 825-835, May/Jun. 2006.
    • (2006) IEEE Trans. Ind. Appl. , vol.42 , Issue.3 , pp. 825-835
    • Suh, Y.1    Lipo, T.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.