Volumn , Issue , 2012, Pages 290-295

Comparison of power fluctuation between Optislip and DFIG controlled wind turbines

Author keywords

Doubly Fed Induction Generator (DFIG); Optislip control method; power quality; standard deviation; wind turbines

Indexed keywords

CONTROL METHODS; DOUBLY FED INDUCTION GENERATORS; OPERATION AND CONTROL; OPTISLIP; OUTPUT POWER; POWER FLUCTUATIONS; STANDARD DEVIATION; VARIABLE SPEED WIND TURBINES; WIND SPEED; WIND SPEED PROFILES;

EID: 84860894267     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PEDSTC.2012.6183343     Document Type: Conference Paper
Times cited : (4)

References (14)
  • 1
    • 69449085926 scopus 로고    scopus 로고
    • A review of the state of the art of power electronics for wind turbines
    • Z. Chen, J.M. Guerrero, and F. Blaabjerg, "A review of the state of the art of power electronics for wind turbines," IEEE Transactions on Power Electronics, vol. 24, 2009, pp. 1859-1875.
    • (2009) IEEE Transactions on Power Electronics , vol.24 , pp. 1859-1875
    • Chen, Z.1    Guerrero, J.M.2    Blaabjerg, F.3
  • 2
    • 4544257662 scopus 로고    scopus 로고
    • Power Electronics as Efficient Interface in Dispersed Power Generation Systems
    • Sep.
    • F. Blaabjerg, Z. Chen, and S.B. Kjaer, "Power Electronics as Efficient Interface in Dispersed Power Generation Systems," IEEE Transactions on Power Electronics, vol. 19, Sep. 2004, pp. 1184-1194.
    • (2004) IEEE Transactions on Power Electronics , vol.19 , pp. 1184-1194
    • Blaabjerg, F.1    Chen, Z.2    Kjaer, S.B.3
  • 4
    • 84869985726 scopus 로고    scopus 로고
    • Effect of wind farm based-on wound rotor induction generator on transient characteristics of transmission grid
    • L. Lin, F. Sun, and Y. Yang, "Effect of wind farm based-on wound rotor induction generator on transient characteristics of transmission grid,"IEEE Power and Energy Engineering Conference, 2009, pp. 1-5.
    • IEEE Power and Energy Engineering Conference, 2009 , pp. 1-5
    • Lin, L.1    Sun, F.2    Yang, Y.3
  • 5
    • 77951465407 scopus 로고    scopus 로고
    • Comparison of reactive power compensation strategy of wind farm based on Optislip wind turbines
    • L. Lin, F. Sun, Y. Yang, and Q. Li, "Comparison of reactive power compensation strategy of wind farm based on Optislip wind turbines,"IEEE Sustainable Power Generation and Supply, 2009, pp. 1-6.
    • (2009) IEEE Sustainable Power Generation and Supply , pp. 1-6
    • Lin, L.1    Sun, F.2    Yang, Y.3    Li, Q.4
  • 9
    • 0036494483 scopus 로고    scopus 로고
    • Flicker emission of wind turbines during continuous operation
    • A. Larsson, "Flicker emission of wind turbines during continuous operation," IEEE Transactions on Energy Conversion, vol. 17, 2002, pp. 114-118.
    • (2002) IEEE Transactions on Energy Conversion , vol.17 , pp. 114-118
    • Larsson, A.1
  • 13
    • 0033343269 scopus 로고    scopus 로고
    • Decoupled control of active and reactive power for a grid-connected doubly-fed wound rotor induction machine without position sensors
    • R. Datta and V.T. Ranganathan, "Decoupled control of active and reactive power for a grid-connected doubly-fed wound rotor induction machine without position sensors," IEEE Industry Applications conference, vol. 4, 1999, pp. 2623-2630.
    • (1999) IEEE Industry Applications Conference , vol.4 , pp. 2623-2630
    • Datta, R.1    Ranganathan, V.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.