메뉴 건너뛰기




Volumn 83, Issue 1, 2013, Pages 1-13

The role of 'no-touch' automated room disinfection systems in infection prevention and control

Author keywords

'No touch' automated room disinfection (NTD); AHP; Disinfection; H2O2; Healthcare associated infections; Hospital; HPV; Hydrogen peroxide vapour aerosol; Surface contamination; Ultraviolet radiation; UVC

Indexed keywords

CHLORINE DIOXIDE; HYDROGEN PEROXIDE; OZONE; XENON;

EID: 84871003763     PISSN: 01956701     EISSN: 15322939     Source Type: Journal    
DOI: 10.1016/j.jhin.2012.10.002     Document Type: Review
Times cited : (117)

References (142)
  • 1
    • 79958739691 scopus 로고    scopus 로고
    • The role played by contaminated surfaces in the transmission of nosocomial pathogens
    • Otter J.A., Yezli S., French G.L. The role played by contaminated surfaces in the transmission of nosocomial pathogens. Infect Control Hosp Epidemiol 2011, 32:687-699.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 687-699
    • Otter, J.A.1    Yezli, S.2    French, G.L.3
  • 2
    • 0020420063 scopus 로고
    • Relation of the inanimate hospital environment to endemic nosocomial infection
    • Maki D.G., Alvarado C.J., Hassemer C.A., Zilz M.A. Relation of the inanimate hospital environment to endemic nosocomial infection. N Engl J Med 1982, 307:1562-1566.
    • (1982) N Engl J Med , vol.307 , pp. 1562-1566
    • Maki, D.G.1    Alvarado, C.J.2    Hassemer, C.A.3    Zilz, M.A.4
  • 3
    • 77952994819 scopus 로고    scopus 로고
    • Role of hospital surfaces in the transmission of emerging health care-associated pathogens: norovirus, Clostridium difficile, and Acinetobacter species
    • Weber D.J., Rutala W.A., Miller M.B., Huslage K., Sickbert-Bennett E. Role of hospital surfaces in the transmission of emerging health care-associated pathogens: norovirus, Clostridium difficile, and Acinetobacter species. Am J Infect Control 2010, 38:S25-S33.
    • (2010) Am J Infect Control , vol.38
    • Weber, D.J.1    Rutala, W.A.2    Miller, M.B.3    Huslage, K.4    Sickbert-Bennett, E.5
  • 4
    • 79952411060 scopus 로고    scopus 로고
    • Evaluation of hospital room assignment and acquisition of Clostridium difficile infection
    • Shaughnessy M.K., Micielli R.L., DePestel D.D., et al. Evaluation of hospital room assignment and acquisition of Clostridium difficile infection. Infect Control Hosp Epidemiol 2011, 32:201-206.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 201-206
    • Shaughnessy, M.K.1    Micielli, R.L.2    DePestel, D.D.3
  • 5
    • 79955130786 scopus 로고    scopus 로고
    • Environmental cleaning intervention and risk of acquiring multidrug-resistant organisms from prior room occupants
    • Datta R., Platt R., Yokoe D.S., Huang S.S. Environmental cleaning intervention and risk of acquiring multidrug-resistant organisms from prior room occupants. Arch Intern Med 2011, 171:491-494.
    • (2011) Arch Intern Med , vol.171 , pp. 491-494
    • Datta, R.1    Platt, R.2    Yokoe, D.S.3    Huang, S.S.4
  • 6
    • 33749574575 scopus 로고    scopus 로고
    • Risk of acquiring antibiotic-resistant bacteria from prior room occupants
    • Huang S.S., Datta R., Platt R. Risk of acquiring antibiotic-resistant bacteria from prior room occupants. Arch Intern Med 2006, 166:1945-1951.
    • (2006) Arch Intern Med , vol.166 , pp. 1945-1951
    • Huang, S.S.1    Datta, R.2    Platt, R.3
  • 7
    • 39749120490 scopus 로고    scopus 로고
    • Prior environmental contamination increases the risk of acquisition of vancomycin-resistant enterococci
    • Drees M., Snydman D., Schmid C., et al. Prior environmental contamination increases the risk of acquisition of vancomycin-resistant enterococci. Clin Infect Dis 2008, 46:678-685.
    • (2008) Clin Infect Dis , vol.46 , pp. 678-685
    • Drees, M.1    Snydman, D.2    Schmid, C.3
  • 8
    • 79958707969 scopus 로고    scopus 로고
    • Risk of acquiring multidrug-resistant Gram-negative bacilli from prior room occupants in the ICU
    • Nseir S., Blazejewski C., Lubret R., Wallet F., Courcol R., Durocher A. Risk of acquiring multidrug-resistant Gram-negative bacilli from prior room occupants in the ICU. Clin Microbiol Infect 2011, 17:1201-1208.
    • (2011) Clin Microbiol Infect , vol.17 , pp. 1201-1208
    • Nseir, S.1    Blazejewski, C.2    Lubret, R.3    Wallet, F.4    Courcol, R.5    Durocher, A.6
  • 9
    • 77952298917 scopus 로고    scopus 로고
    • Hospital-acquired infections due to gram-negative bacteria
    • Peleg A.Y., Hooper D.C. Hospital-acquired infections due to gram-negative bacteria. N Engl J Med 2010, 362:1804-1813.
    • (2010) N Engl J Med , vol.362 , pp. 1804-1813
    • Peleg, A.Y.1    Hooper, D.C.2
  • 10
    • 34250195733 scopus 로고    scopus 로고
    • Prevalence of Clostridium difficile environmental contamination and strain variability in multiple health care facilities
    • Dubberke E.R., Reske K.A., Noble-Wang J., et al. Prevalence of Clostridium difficile environmental contamination and strain variability in multiple health care facilities. Am J Infect Control 2007, 35:315-318.
    • (2007) Am J Infect Control , vol.35 , pp. 315-318
    • Dubberke, E.R.1    Reske, K.A.2    Noble-Wang, J.3
  • 11
    • 79960716757 scopus 로고    scopus 로고
    • Are room decontamination units needed to prevent transmission of environmental pathogens?
    • Rutala W.A., Weber D.J. Are room decontamination units needed to prevent transmission of environmental pathogens?. Infect Control Hosp Epidemiol 2011, 32:743-747.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 743-747
    • Rutala, W.A.1    Weber, D.J.2
  • 12
    • 79951854245 scopus 로고    scopus 로고
    • Gaseous and air decontamination technologies for Clostridium difficile in the healthcare environment
    • Davies A., Pottage T., Bennett A., Walker J. Gaseous and air decontamination technologies for Clostridium difficile in the healthcare environment. J Hosp Infect 2011, 77:199-203.
    • (2011) J Hosp Infect , vol.77 , pp. 199-203
    • Davies, A.1    Pottage, T.2    Bennett, A.3    Walker, J.4
  • 13
    • 79958738877 scopus 로고    scopus 로고
    • Airborne hydrogen peroxide for disinfection of the hospital environment and infection control: a systematic review
    • Falagas M.E., Thomaidis P.C., Kotsantis I.K., Sgouros K., Samonis G., Karageorgopoulos D.E. Airborne hydrogen peroxide for disinfection of the hospital environment and infection control: a systematic review. J Hosp Infect 2011, 78:171-177.
    • (2011) J Hosp Infect , vol.78 , pp. 171-177
    • Falagas, M.E.1    Thomaidis, P.C.2    Kotsantis, I.K.3    Sgouros, K.4    Samonis, G.5    Karageorgopoulos, D.E.6
  • 14
    • 79955670851 scopus 로고    scopus 로고
    • The risks and benefits of chemical fumigation in the health care environment
    • Byrns G., Fuller T.P. The risks and benefits of chemical fumigation in the health care environment. J Occup Environ Hyg 2011, 8:104-112.
    • (2011) J Occup Environ Hyg , vol.8 , pp. 104-112
    • Byrns, G.1    Fuller, T.P.2
  • 15
    • 0031812744 scopus 로고    scopus 로고
    • Nosocomial infection update
    • Weinstein R.A. Nosocomial infection update. Emerg Infect Dis 1998, 4:416-420.
    • (1998) Emerg Infect Dis , vol.4 , pp. 416-420
    • Weinstein, R.A.1
  • 16
    • 84871026280 scopus 로고
    • The disinfection of sick-rooms and their contents
    • Riddle M.M. The disinfection of sick-rooms and their contents. Am J Nursing 1901, 1:568-573.
    • (1901) Am J Nursing , vol.1 , pp. 568-573
    • Riddle, M.M.1
  • 17
    • 0014250108 scopus 로고
    • Terminal disinfection in hospitals with quaternary ammonium compounds by use of a spray-fog technique
    • Friedman H., Volin E., Laumann D. Terminal disinfection in hospitals with quaternary ammonium compounds by use of a spray-fog technique. Appl Microbiol 1968, 16:223-227.
    • (1968) Appl Microbiol , vol.16 , pp. 223-227
    • Friedman, H.1    Volin, E.2    Laumann, D.3
  • 18
    • 33847176383 scopus 로고
    • Evaluation of disinfectants for hospital housekeeping use
    • Ostrander W.E., Griffith L.J. Evaluation of disinfectants for hospital housekeeping use. Appl Microbiol 1964, 12:460-463.
    • (1964) Appl Microbiol , vol.12 , pp. 460-463
    • Ostrander, W.E.1    Griffith, L.J.2
  • 19
    • 0016336799 scopus 로고
    • Terminal disinfection of contaminated patient care areas: to fog or not to fog?
    • Munster A.M., Ostrander W.E. Terminal disinfection of contaminated patient care areas: to fog or not to fog?. Am Surg 1974, 40:713-715.
    • (1974) Am Surg , vol.40 , pp. 713-715
    • Munster, A.M.1    Ostrander, W.E.2
  • 20
    • 84871000826 scopus 로고    scopus 로고
    • Healthcare Infection Control Practices Advisory Committee (HICPAC). Guideline for disinfection and sterilization in healthcare facilities
    • Rutala WA, Weber DJ, Healthcare Infection Control Practices Advisory Committee (HICPAC). Guideline for disinfection and sterilization in healthcare facilities. 2008.
    • (2008)
    • Rutala, W.A.1    Weber, D.J.2
  • 21
    • 39549090391 scopus 로고    scopus 로고
    • Risk of hand or glove contamination after contact with patients colonized with vancomycin-resistant Enterococcus or the colonized patients' environment
    • Hayden M.K., Blom D.W., Lyle E.A., Moore C.G., Weinstein R.A. Risk of hand or glove contamination after contact with patients colonized with vancomycin-resistant Enterococcus or the colonized patients' environment. Infect Control Hosp Epidemiol 2008, 29:149-154.
    • (2008) Infect Control Hosp Epidemiol , vol.29 , pp. 149-154
    • Hayden, M.K.1    Blom, D.W.2    Lyle, E.A.3    Moore, C.G.4    Weinstein, R.A.5
  • 22
    • 78751670846 scopus 로고    scopus 로고
    • Contamination of hands with methicillin-resistant Staphylococcus aureus after contact with environmental surfaces and after contact with the skin of colonized patients
    • Stiefel U., Cadnum J.L., Eckstein B.C., Guerrero D.M., Tima M.A., Donskey C.J. Contamination of hands with methicillin-resistant Staphylococcus aureus after contact with environmental surfaces and after contact with the skin of colonized patients. Infect Control Hosp Epidemiol 2011, 32:185-187.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 185-187
    • Stiefel, U.1    Cadnum, J.L.2    Eckstein, B.C.3    Guerrero, D.M.4    Tima, M.A.5    Donskey, C.J.6
  • 23
    • 33748681343 scopus 로고    scopus 로고
    • How long do nosocomial pathogens persist on inanimate surfaces? A systematic review
    • Kramer A., Schwebke I., Kampf G. How long do nosocomial pathogens persist on inanimate surfaces? A systematic review. BMC Infect Dis 2006, 6:130.
    • (2006) BMC Infect Dis , vol.6 , pp. 130
    • Kramer, A.1    Schwebke, I.2    Kampf, G.3
  • 24
    • 77958554415 scopus 로고    scopus 로고
    • Use of purified Clostridium difficile spores to facilitate evaluation of health care disinfection regimens
    • Lawley T.D., Clare S., Deakin L.J., et al. Use of purified Clostridium difficile spores to facilitate evaluation of health care disinfection regimens. Appl Environ Microbiol 2010, 76:6895-6900.
    • (2010) Appl Environ Microbiol , vol.76 , pp. 6895-6900
    • Lawley, T.D.1    Clare, S.2    Deakin, L.J.3
  • 25
    • 0025310084 scopus 로고
    • Quantitative study of antibiotic-induced susceptibility to Clostridium difficile enterocecitis in hamsters
    • Larson H.E., Borriello S.P. Quantitative study of antibiotic-induced susceptibility to Clostridium difficile enterocecitis in hamsters. Antimicrob Agents Chemother 1990, 34:1348-1353.
    • (1990) Antimicrob Agents Chemother , vol.34 , pp. 1348-1353
    • Larson, H.E.1    Borriello, S.P.2
  • 26
    • 79952835307 scopus 로고    scopus 로고
    • Minimum infective dose of the major human respiratory and enteric viruses transmitted through food and the environment
    • Yezli S., Otter J.A. Minimum infective dose of the major human respiratory and enteric viruses transmitted through food and the environment. Food Environ Microbiol 2011, 3:1-30.
    • (2011) Food Environ Microbiol , vol.3 , pp. 1-30
    • Yezli, S.1    Otter, J.A.2
  • 27
    • 78951489303 scopus 로고    scopus 로고
    • Norovirus in the hospital setting: virus introduction and spread within the hospital environment
    • Morter S., Bennet G., Fish J., et al. Norovirus in the hospital setting: virus introduction and spread within the hospital environment. J Hosp Infect 2011, 77:106-112.
    • (2011) J Hosp Infect , vol.77 , pp. 106-112
    • Morter, S.1    Bennet, G.2    Fish, J.3
  • 28
    • 0346338099 scopus 로고    scopus 로고
    • How do we assess hospital cleaning? A proposal for microbiological standards for surface hygiene in hospitals
    • Dancer S.J. How do we assess hospital cleaning? A proposal for microbiological standards for surface hygiene in hospitals. J Hosp Infect 2004, 56:10-15.
    • (2004) J Hosp Infect , vol.56 , pp. 10-15
    • Dancer, S.J.1
  • 30
    • 84857026054 scopus 로고    scopus 로고
    • Hydrogen peroxide vapor and aerosol room decontamination systems
    • Roberts C.G. Hydrogen peroxide vapor and aerosol room decontamination systems. Infect Control Hosp Epidemiol 2012, 33:312.
    • (2012) Infect Control Hosp Epidemiol , vol.33 , pp. 312
    • Roberts, C.G.1
  • 31
    • 2342485984 scopus 로고    scopus 로고
    • Tackling contamination of the hospital environment by methicillin-resistant Staphylococcus aureus (MRSA): a comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination
    • French G.L., Otter J.A., Shannon K.P., Adams N.M., Watling D., Parks M.J. Tackling contamination of the hospital environment by methicillin-resistant Staphylococcus aureus (MRSA): a comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination. J Hosp Infect 2004, 57:31-37.
    • (2004) J Hosp Infect , vol.57 , pp. 31-37
    • French, G.L.1    Otter, J.A.2    Shannon, K.P.3    Adams, N.M.4    Watling, D.5    Parks, M.J.6
  • 33
    • 79958705712 scopus 로고    scopus 로고
    • Isolation of Acinetobacter baumannii complex and methicillin-resistant Staphylococcus aureus from hospital rooms following terminal cleaning and disinfection: can we do better?
    • Manian F.A., Griesenauer S., Senkel D., et al. Isolation of Acinetobacter baumannii complex and methicillin-resistant Staphylococcus aureus from hospital rooms following terminal cleaning and disinfection: can we do better?. Infect Control Hosp Epidemiol 2011, 32:667-672.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 667-672
    • Manian, F.A.1    Griesenauer, S.2    Senkel, D.3
  • 34
    • 0041519141 scopus 로고    scopus 로고
    • Comparison of the effect of detergent versus hypochlorite cleaning on environmental contamination and incidence of Clostridium difficile infection
    • Wilcox M.H., Fawley W.N., Wigglesworth N., Parnell P., Verity P., Freeman J. Comparison of the effect of detergent versus hypochlorite cleaning on environmental contamination and incidence of Clostridium difficile infection. J Hosp Infect 2003, 54:109-114.
    • (2003) J Hosp Infect , vol.54 , pp. 109-114
    • Wilcox, M.H.1    Fawley, W.N.2    Wigglesworth, N.3    Parnell, P.4    Verity, P.5    Freeman, J.6
  • 36
    • 78650514084 scopus 로고    scopus 로고
    • Finding a benchmark for monitoring hospital cleanliness
    • Mulvey D., Redding P., Robertson C., et al. Finding a benchmark for monitoring hospital cleanliness. J Hosp Infect 2011, 77:25-30.
    • (2011) J Hosp Infect , vol.77 , pp. 25-30
    • Mulvey, D.1    Redding, P.2    Robertson, C.3
  • 37
    • 67651098977 scopus 로고    scopus 로고
    • Monitoring the effectiveness of hospital cleaning practices by use of an adenosine triphosphate bioluminescence assay
    • Boyce J.M., Havill N.L., Dumigan D.G., Golebiewski M., Balogun O., Rizvani R. Monitoring the effectiveness of hospital cleaning practices by use of an adenosine triphosphate bioluminescence assay. Infect Control Hosp Epidemiol 2009, 30:678-684.
    • (2009) Infect Control Hosp Epidemiol , vol.30 , pp. 678-684
    • Boyce, J.M.1    Havill, N.L.2    Dumigan, D.G.3    Golebiewski, M.4    Balogun, O.5    Rizvani, R.6
  • 38
  • 39
    • 47549098621 scopus 로고    scopus 로고
    • Impact of an environmental cleaning intervention on the presence of methicillin-resistant Staphylococcus aureus and vancomycin-resistant enterococci on surfaces in intensive care unit rooms
    • Goodman E.R., Platt R., Bass R., Onderdonk A.B., Yokoe D.S., Huang S.S. Impact of an environmental cleaning intervention on the presence of methicillin-resistant Staphylococcus aureus and vancomycin-resistant enterococci on surfaces in intensive care unit rooms. Infect Control Hosp Epidemiol 2008, 29:593-599.
    • (2008) Infect Control Hosp Epidemiol , vol.29 , pp. 593-599
    • Goodman, E.R.1    Platt, R.2    Bass, R.3    Onderdonk, A.B.4    Yokoe, D.S.5    Huang, S.S.6
  • 40
    • 34447296689 scopus 로고    scopus 로고
    • Reduction of Clostridium difficile and vancomycin-resistant Enterococcus contamination of environmental surfaces after an intervention to improve cleaning methods
    • Eckstein B.C., Adams D.A., Eckstein E.C., et al. Reduction of Clostridium difficile and vancomycin-resistant Enterococcus contamination of environmental surfaces after an intervention to improve cleaning methods. BMC Infect Dis 2007, 7:61.
    • (2007) BMC Infect Dis , vol.7 , pp. 61
    • Eckstein, B.C.1    Adams, D.A.2    Eckstein, E.C.3
  • 41
    • 67649846501 scopus 로고    scopus 로고
    • Measuring the effect of enhanced cleaning in a UK hospital: a prospective cross-over study
    • Dancer S.J., White L.F., Lamb J., Girvan E.K., Robertson C. Measuring the effect of enhanced cleaning in a UK hospital: a prospective cross-over study. BMC Med 2009, 7:28.
    • (2009) BMC Med , vol.7 , pp. 28
    • Dancer, S.J.1    White, L.F.2    Lamb, J.3    Girvan, E.K.4    Robertson, C.5
  • 42
    • 33646751714 scopus 로고    scopus 로고
    • Reduction in acquisition of vancomycin-resistant enterococcus after enforcement of routine environmental cleaning measures
    • Hayden M.K., Bonten M.J., Blom D.W., Lyle E.A., van de Vijver D.A., Weinstein R.A. Reduction in acquisition of vancomycin-resistant enterococcus after enforcement of routine environmental cleaning measures. Clin Infect Dis 2006, 42:1552-1560.
    • (2006) Clin Infect Dis , vol.42 , pp. 1552-1560
    • Hayden, M.K.1    Bonten, M.J.2    Blom, D.W.3    Lyle, E.A.4    van de Vijver, D.A.5    Weinstein, R.A.6
  • 43
    • 23044479434 scopus 로고    scopus 로고
    • Eradication of persistent environmental MRSA
    • Jeanes A., Rao G., Osman M., Merrick P. Eradication of persistent environmental MRSA. J Hosp Infect 2005, 61:85-86.
    • (2005) J Hosp Infect , vol.61 , pp. 85-86
    • Jeanes, A.1    Rao, G.2    Osman, M.3    Merrick, P.4
  • 44
    • 22544467289 scopus 로고    scopus 로고
    • Hospital disinfection: efficacy and safety issues
    • Dettenkofer M., Block C. Hospital disinfection: efficacy and safety issues. Curr Opin Infect Dis 2005, 18:320-325.
    • (2005) Curr Opin Infect Dis , vol.18 , pp. 320-325
    • Dettenkofer, M.1    Block, C.2
  • 45
    • 0024058657 scopus 로고
    • Effects of sodium hypochlorite on denture base metals during immersion for short-term sterilization
    • McGowan M.J., Shimoda L.M., Woolsey G.D. Effects of sodium hypochlorite on denture base metals during immersion for short-term sterilization. J Prosthet Dent 1988, 60:212-218.
    • (1988) J Prosthet Dent , vol.60 , pp. 212-218
    • McGowan, M.J.1    Shimoda, L.M.2    Woolsey, G.D.3
  • 46
    • 34347391513 scopus 로고    scopus 로고
    • Occupational risk factors for asthma among nurses and related healthcare professionals in an international study
    • Mirabelli M.C., Zock J.P., Plana E., et al. Occupational risk factors for asthma among nurses and related healthcare professionals in an international study. Occup Environ Med 2007, 64:474-479.
    • (2007) Occup Environ Med , vol.64 , pp. 474-479
    • Mirabelli, M.C.1    Zock, J.P.2    Plana, E.3
  • 47
    • 50949120269 scopus 로고    scopus 로고
    • Impact of hydrogen peroxide vapor room decontamination on Clostridium difficile environmental contamination and transmission in a healthcare setting
    • Boyce J.M., Havill N.L., Otter J.A., et al. Impact of hydrogen peroxide vapor room decontamination on Clostridium difficile environmental contamination and transmission in a healthcare setting. Infect Control Hosp Epidemiol 2008, 29:723-729.
    • (2008) Infect Control Hosp Epidemiol , vol.29 , pp. 723-729
    • Boyce, J.M.1    Havill, N.L.2    Otter, J.A.3
  • 48
    • 79958694492 scopus 로고    scopus 로고
    • Impact of environmental decontamination using hydrogen peroxide vapour on the incidence of Clostridium difficile infection in one hospital Trust
    • Cooper T., O'Leary M., Yezli S., Otter J.A. Impact of environmental decontamination using hydrogen peroxide vapour on the incidence of Clostridium difficile infection in one hospital Trust. J Hosp Infect 2011, 78:238-240.
    • (2011) J Hosp Infect , vol.78 , pp. 238-240
    • Cooper, T.1    O'Leary, M.2    Yezli, S.3    Otter, J.A.4
  • 49
    • 39049122532 scopus 로고    scopus 로고
    • Hydrogen peroxide vapour decontamination in the control of a polyclonal meticillin-resistant Staphylococcus aureus outbreak on a surgical ward
    • Dryden M., Parnaby R., Dailly S., et al. Hydrogen peroxide vapour decontamination in the control of a polyclonal meticillin-resistant Staphylococcus aureus outbreak on a surgical ward. J Hosp Infect 2008, 68:190-192.
    • (2008) J Hosp Infect , vol.68 , pp. 190-192
    • Dryden, M.1    Parnaby, R.2    Dailly, S.3
  • 50
    • 84870978820 scopus 로고    scopus 로고
    • Management of a multi-year MDR Acinetobacter baumannii outbreak in the ICU setting
    • Infectious Diseases Society of America (IDSA) Annual Meeting. Abstract 394.
    • Kaiser M, Elemendorf S, Kent D, Evans A, Harrington SM, McKenna D. Management of a multi-year MDR Acinetobacter baumannii outbreak in the ICU setting. Infectious Diseases Society of America (IDSA) Annual Meeting. Abstract 394. 2011.
    • (2011)
    • Kaiser, M.1    Elemendorf, S.2    Kent, D.3    Evans, A.4    Harrington, S.M.5    McKenna, D.6
  • 51
    • 78049370096 scopus 로고    scopus 로고
    • Hydrogen peroxide vapor decontamination of an intensive care unit to remove environmental reservoirs of multidrug-resistant gram-negative rods during an outbreak
    • Otter J.A., Yezli S., Schouten M.A., van Zanten A.R., Houmes-Zielman G., Nohlmans-Paulssen M.K. Hydrogen peroxide vapor decontamination of an intensive care unit to remove environmental reservoirs of multidrug-resistant gram-negative rods during an outbreak. Am J Infect Control 2010, 38:754-756.
    • (2010) Am J Infect Control , vol.38 , pp. 754-756
    • Otter, J.A.1    Yezli, S.2    Schouten, M.A.3    van Zanten, A.R.4    Houmes-Zielman, G.5    Nohlmans-Paulssen, M.K.6
  • 52
    • 78649950309 scopus 로고    scopus 로고
    • Use of vaporized hydrogen peroxide decontamination during an outbreak of multidrug-resistant Acinetobacter baumannii infection at a long-term acute care hospital
    • Ray A., Perez F., Beltramini A.M., et al. Use of vaporized hydrogen peroxide decontamination during an outbreak of multidrug-resistant Acinetobacter baumannii infection at a long-term acute care hospital. Infect Control Hosp Epidemiol 2010, 31:1236-1241.
    • (2010) Infect Control Hosp Epidemiol , vol.31 , pp. 1236-1241
    • Ray, A.1    Perez, F.2    Beltramini, A.M.3
  • 53
    • 13844319541 scopus 로고    scopus 로고
    • Use of hydrogen peroxide vapour for environmental control during a Serratia outbreak in a neonatal intensive care unit
    • Bates C.J., Pearse R. Use of hydrogen peroxide vapour for environmental control during a Serratia outbreak in a neonatal intensive care unit. J Hosp Infect 2005, 61:364-366.
    • (2005) J Hosp Infect , vol.61 , pp. 364-366
    • Bates, C.J.1    Pearse, R.2
  • 54
    • 34547668867 scopus 로고    scopus 로고
    • Rapid recontamination with MRSA of the environment of an intensive care unit after decontamination with hydrogen peroxide vapour
    • Hardy K.J., Gossain S., Henderson N., et al. Rapid recontamination with MRSA of the environment of an intensive care unit after decontamination with hydrogen peroxide vapour. J Hosp Infect 2007, 66:360-368.
    • (2007) J Hosp Infect , vol.66 , pp. 360-368
    • Hardy, K.J.1    Gossain, S.2    Henderson, N.3
  • 55
    • 35148817124 scopus 로고    scopus 로고
    • Assessing the biological efficacy and rate of recontamination following hydrogen peroxide vapour decontamination
    • Otter J.A., Cummins M., Ahmad F., van Tonder C., Drabu Y.J. Assessing the biological efficacy and rate of recontamination following hydrogen peroxide vapour decontamination. J Hosp Infect 2007, 67:182-188.
    • (2007) J Hosp Infect , vol.67 , pp. 182-188
    • Otter, J.A.1    Cummins, M.2    Ahmad, F.3    van Tonder, C.4    Drabu, Y.J.5
  • 56
    • 34848846245 scopus 로고    scopus 로고
    • Asymptomatic carriers are a potential source for transmission of epidemic and nonepidemic Clostridium difficile strains among long-term care facility residents
    • Riggs M.M., Sethi A.K., Zabarsky T.F., Eckstein E.C., Jump R.L., Donskey C.J. Asymptomatic carriers are a potential source for transmission of epidemic and nonepidemic Clostridium difficile strains among long-term care facility residents. Clin Infect Dis 2007, 45:992-998.
    • (2007) Clin Infect Dis , vol.45 , pp. 992-998
    • Riggs, M.M.1    Sethi, A.K.2    Zabarsky, T.F.3    Eckstein, E.C.4    Jump, R.L.5    Donskey, C.J.6
  • 57
    • 33744519313 scopus 로고    scopus 로고
    • Nosocomial aspergillosis in outbreak settings
    • Vonberg R.P., Gastmeier P. Nosocomial aspergillosis in outbreak settings. J Hosp Infect 2006, 63:246-254.
    • (2006) J Hosp Infect , vol.63 , pp. 246-254
    • Vonberg, R.P.1    Gastmeier, P.2
  • 58
    • 77954536801 scopus 로고    scopus 로고
    • Hydrogen peroxide vapour decontamination of a critical care unit room used to treat a patient with Lassa fever
    • Otter J.A., Barnicoat M., Down J., Smyth D., Yezli S., Jeanes A. Hydrogen peroxide vapour decontamination of a critical care unit room used to treat a patient with Lassa fever. J Hosp Infect 2010, 75:335-337.
    • (2010) J Hosp Infect , vol.75 , pp. 335-337
    • Otter, J.A.1    Barnicoat, M.2    Down, J.3    Smyth, D.4    Yezli, S.5    Jeanes, A.6
  • 59
    • 26944433798 scopus 로고    scopus 로고
    • Outbreak of infection with a multiresistant Klebsiella pneumoniae strain associated with contaminated roll boards in operating rooms
    • van't Veen A., van der Zee A., Nelson J., Speelberg B., Kluytmans J.A., Buiting A.G. Outbreak of infection with a multiresistant Klebsiella pneumoniae strain associated with contaminated roll boards in operating rooms. J Clin Microbiol 2005, 43:4961-4967.
    • (2005) J Clin Microbiol , vol.43 , pp. 4961-4967
    • van't Veen, A.1    van der Zee, A.2    Nelson, J.3    Speelberg, B.4    Kluytmans, J.A.5    Buiting, A.G.6
  • 60
    • 0031229649 scopus 로고    scopus 로고
    • Environmental contamination due to methicillin-resistant Staphylococcus aureus: possible infection control implications
    • Boyce J.M., Potter-Bynoe G., Chenevert C., King T. Environmental contamination due to methicillin-resistant Staphylococcus aureus: possible infection control implications. Infect Control Hosp Epidemiol 1997, 18:622-627.
    • (1997) Infect Control Hosp Epidemiol , vol.18 , pp. 622-627
    • Boyce, J.M.1    Potter-Bynoe, G.2    Chenevert, C.3    King, T.4
  • 61
    • 58549096354 scopus 로고    scopus 로고
    • What is on that keyboard? Detecting hidden environmental reservoirs of Clostridium difficile during an outbreak associated with North American pulsed-field gel electrophoresis type 1 strains
    • Dumford D.M., Nerandzic M.M., Eckstein B.C., Donskey C.J. What is on that keyboard? Detecting hidden environmental reservoirs of Clostridium difficile during an outbreak associated with North American pulsed-field gel electrophoresis type 1 strains. Am J Infect Control 2009, 37:15-19.
    • (2009) Am J Infect Control , vol.37 , pp. 15-19
    • Dumford, D.M.1    Nerandzic, M.M.2    Eckstein, B.C.3    Donskey, C.J.4
  • 62
    • 67651098975 scopus 로고    scopus 로고
    • New approaches to decontamination of rooms after patients are discharged
    • Boyce J.M. New approaches to decontamination of rooms after patients are discharged. Infect Control Hosp Epidemiol 2009, 30:515-517.
    • (2009) Infect Control Hosp Epidemiol , vol.30 , pp. 515-517
    • Boyce, J.M.1
  • 63
    • 58449086206 scopus 로고    scopus 로고
    • Surface disinfection: evaluation of the efficacy of a nebulization system spraying hydrogen peroxide
    • Orlando P., Cristina M.L., Dallera M., Ottria G., Vitale A., Badolati G. Surface disinfection: evaluation of the efficacy of a nebulization system spraying hydrogen peroxide. J Prev Med Hyg 2008, 49:116-119.
    • (2008) J Prev Med Hyg , vol.49 , pp. 116-119
    • Orlando, P.1    Cristina, M.L.2    Dallera, M.3    Ottria, G.4    Vitale, A.5    Badolati, G.6
  • 64
    • 79952383241 scopus 로고    scopus 로고
    • Evaluation of a pulsed-xenon ultraviolet room disinfection device for impact on hospital operations and microbial reduction
    • Stibich M., Stachowiak J., Tanner B., et al. Evaluation of a pulsed-xenon ultraviolet room disinfection device for impact on hospital operations and microbial reduction. Infect Control Hosp Epidemiol 2011, 32:286-288.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 286-288
    • Stibich, M.1    Stachowiak, J.2    Tanner, B.3
  • 65
    • 77957869791 scopus 로고    scopus 로고
    • Hydrogen peroxide vapor is not the same as aerosolized hydrogen peroxide
    • Otter J.A., Havill N.L., Boyce J.M. Hydrogen peroxide vapor is not the same as aerosolized hydrogen peroxide. Infect Control Hosp Epidemiol 2010, 31:1201-1202.
    • (2010) Infect Control Hosp Epidemiol , vol.31 , pp. 1201-1202
    • Otter, J.A.1    Havill, N.L.2    Boyce, J.M.3
  • 66
    • 78650512722 scopus 로고    scopus 로고
    • A call for clarity when discussing hydrogen peroxide vapour and aerosol systems
    • Otter J.A., Yezli S. A call for clarity when discussing hydrogen peroxide vapour and aerosol systems. J Hosp Infect 2011, 77:83-84.
    • (2011) J Hosp Infect , vol.77 , pp. 83-84
    • Otter, J.A.1    Yezli, S.2
  • 67
    • 50849110800 scopus 로고    scopus 로고
    • Activity of a dry mist hydrogen peroxide system against environmental Clostridium difficile contamination in elderly care wards
    • Shapey S., Machin K., Levi K., Boswell T.C. Activity of a dry mist hydrogen peroxide system against environmental Clostridium difficile contamination in elderly care wards. J Hosp Infect 2008, 70:136-141.
    • (2008) J Hosp Infect , vol.70 , pp. 136-141
    • Shapey, S.1    Machin, K.2    Levi, K.3    Boswell, T.C.4
  • 68
    • 80052268461 scopus 로고    scopus 로고
    • Evaluation of the biological efficacy of hydrogen peroxide vapour decontamination in wards of an Australian hospital
    • Chan H.T., White P., Sheorey H., Cocks J., Waters M.J. Evaluation of the biological efficacy of hydrogen peroxide vapour decontamination in wards of an Australian hospital. J Hosp Infect 2011, 79:125-128.
    • (2011) J Hosp Infect , vol.79 , pp. 125-128
    • Chan, H.T.1    White, P.2    Sheorey, H.3    Cocks, J.4    Waters, M.J.5
  • 69
    • 80051707002 scopus 로고    scopus 로고
    • A head-to-head comparison of hydrogen peroxide vapor and aerosol room decontamination systems
    • Holmdahl T., Lanbeck P., Wullt M., Walder M.H. A head-to-head comparison of hydrogen peroxide vapor and aerosol room decontamination systems. Infect Control Hosp Epidemiol 2011, 32:831-836.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 831-836
    • Holmdahl, T.1    Lanbeck, P.2    Wullt, M.3    Walder, M.H.4
  • 70
    • 84857140561 scopus 로고    scopus 로고
    • Efficacy, efficiency and safety aspects of hydrogen peroxide vapour and aerosolized hydrogen peroxide room disinfection systems
    • Fu T.Y., Gent P., Kumar V. Efficacy, efficiency and safety aspects of hydrogen peroxide vapour and aerosolized hydrogen peroxide room disinfection systems. J Hosp Infect 2012, 80:199-205.
    • (2012) J Hosp Infect , vol.80 , pp. 199-205
    • Fu, T.Y.1    Gent, P.2    Kumar, V.3
  • 71
    • 30344456669 scopus 로고    scopus 로고
    • Decontamination of rooms, medical equipment and ambulances using an aerosol of hydrogen peroxide disinfectant
    • Andersen B.M., Rasch M., Hochlin K., Jensen F.H., Wismar P., Fredriksen J.E. Decontamination of rooms, medical equipment and ambulances using an aerosol of hydrogen peroxide disinfectant. J Hosp Infect 2006, 62:149-155.
    • (2006) J Hosp Infect , vol.62 , pp. 149-155
    • Andersen, B.M.1    Rasch, M.2    Hochlin, K.3    Jensen, F.H.4    Wismar, P.5    Fredriksen, J.E.6
  • 72
    • 48749123087 scopus 로고    scopus 로고
    • Environmental meticillin-resistant Staphylococcus aureus (MRSA) disinfection using dry-mist-generated hydrogen peroxide
    • Bartels M.D., Kristoffersen K., Slotsbjerg T., Rohde S.M., Lundgren B., Westh H. Environmental meticillin-resistant Staphylococcus aureus (MRSA) disinfection using dry-mist-generated hydrogen peroxide. J Hosp Infect 2008, 70:35-41.
    • (2008) J Hosp Infect , vol.70 , pp. 35-41
    • Bartels, M.D.1    Kristoffersen, K.2    Slotsbjerg, T.3    Rohde, S.M.4    Lundgren, B.5    Westh, H.6
  • 73
    • 67651089832 scopus 로고    scopus 로고
    • Comparison of the efficacy of a hydrogen peroxide dry-mist disinfection system and sodium hypochlorite solution for eradication of Clostridium difficile spores
    • Barbut F., Menuet D., Verachten M., Girou E. Comparison of the efficacy of a hydrogen peroxide dry-mist disinfection system and sodium hypochlorite solution for eradication of Clostridium difficile spores. Infect Control Hosp Epidemiol 2009, 30:515-517.
    • (2009) Infect Control Hosp Epidemiol , vol.30 , pp. 515-517
    • Barbut, F.1    Menuet, D.2    Verachten, M.3    Girou, E.4
  • 74
    • 80055099862 scopus 로고    scopus 로고
    • Activity of a dry mist-generated hydrogen peroxide disinfection system against methicillin-resistant Staphylococcus aureus and Acinetobacter baumannii
    • Piskin N., Celebi G., Kulah C., Mengeloglu Z., Yumusak M. Activity of a dry mist-generated hydrogen peroxide disinfection system against methicillin-resistant Staphylococcus aureus and Acinetobacter baumannii. Am J Infect Control 2011, 39:757-762.
    • (2011) Am J Infect Control , vol.39 , pp. 757-762
    • Piskin, N.1    Celebi, G.2    Kulah, C.3    Mengeloglu, Z.4    Yumusak, M.5
  • 75
    • 84868531784 scopus 로고    scopus 로고
    • Comparison of multiple systems for laboratory whole room fumigation
    • Beswick A.J., Farrant J., Makison C., et al. Comparison of multiple systems for laboratory whole room fumigation. Applied Biosafety 2011, 16:139-157.
    • (2011) Applied Biosafety , vol.16 , pp. 139-157
    • Beswick, A.J.1    Farrant, J.2    Makison, C.3
  • 76
    • 77955509767 scopus 로고    scopus 로고
    • Failure of dry mist of hydrogen peroxide 5% to kill Mycobacterium tuberculosis
    • Andersen B.M., Syversen G., Thoresen H., et al. Failure of dry mist of hydrogen peroxide 5% to kill Mycobacterium tuberculosis. J Hosp Infect 2010, 76:80-83.
    • (2010) J Hosp Infect , vol.76 , pp. 80-83
    • Andersen, B.M.1    Syversen, G.2    Thoresen, H.3
  • 77
    • 78650513354 scopus 로고    scopus 로고
    • Does 'airborne' hydrogen peroxide kill Mycobacterium tuberculosis?
    • Andersen B.M. Does 'airborne' hydrogen peroxide kill Mycobacterium tuberculosis?. J Hosp Infect 2010, 77:81-83.
    • (2010) J Hosp Infect , vol.77 , pp. 81-83
    • Andersen, B.M.1
  • 78
    • 53649103230 scopus 로고    scopus 로고
    • Efficacy of dry mist of hydrogen peroxide (DMHP) against Mycobacterium tuberculosis and use of DMHP for routine decontamination of biosafety level 3 laboratories
    • Grare M., Dailloux M., Simon L., Dimajo P., Laurain C. Efficacy of dry mist of hydrogen peroxide (DMHP) against Mycobacterium tuberculosis and use of DMHP for routine decontamination of biosafety level 3 laboratories. J Clin Microbiol 2008, 46:2955-2958.
    • (2008) J Clin Microbiol , vol.46 , pp. 2955-2958
    • Grare, M.1    Dailloux, M.2    Simon, L.3    Dimajo, P.4    Laurain, C.5
  • 79
    • 84455202330 scopus 로고    scopus 로고
    • Meticillin-resistant Staphylococcus aureus is more resistant to vaporized hydrogen peroxide than commercial Geobacillus stearothermophilus biological indicators
    • Pottage T., Macken S., Walker J.T., Bennett A.M. Meticillin-resistant Staphylococcus aureus is more resistant to vaporized hydrogen peroxide than commercial Geobacillus stearothermophilus biological indicators. J Hosp Infect 2012, 80:41-45.
    • (2012) J Hosp Infect , vol.80 , pp. 41-45
    • Pottage, T.1    Macken, S.2    Walker, J.T.3    Bennett, A.M.4
  • 80
    • 58849105967 scopus 로고    scopus 로고
    • Survival of nosocomial bacteria and spores on surfaces and inactivation by hydrogen peroxide vapor
    • Otter J.A., French G.L. Survival of nosocomial bacteria and spores on surfaces and inactivation by hydrogen peroxide vapor. J Clin Microbiol 2009, 47:205-207.
    • (2009) J Clin Microbiol , vol.47 , pp. 205-207
    • Otter, J.A.1    French, G.L.2
  • 81
    • 0032926818 scopus 로고    scopus 로고
    • Antiseptics and disinfectants: activity, action, and resistance
    • McDonnell G., Russell A.D. Antiseptics and disinfectants: activity, action, and resistance. Clin Microbiol Rev 1999, 12:147-179.
    • (1999) Clin Microbiol Rev , vol.12 , pp. 147-179
    • McDonnell, G.1    Russell, A.D.2
  • 82
    • 77957665980 scopus 로고    scopus 로고
    • Does microbial resistance or adaptation to biocides create a hazard in infection prevention and control?
    • Meyer B., Cookson B. Does microbial resistance or adaptation to biocides create a hazard in infection prevention and control?. J Hosp Infect 2010, 76:200-205.
    • (2010) J Hosp Infect , vol.76 , pp. 200-205
    • Meyer, B.1    Cookson, B.2
  • 83
    • 34250015067 scopus 로고    scopus 로고
    • The increasing use of silver-based products as antimicrobial agents: a useful development or a cause for concern?
    • Chopra I. The increasing use of silver-based products as antimicrobial agents: a useful development or a cause for concern?. J Antimicrob Chemother 2007, 59:587-590.
    • (2007) J Antimicrob Chemother , vol.59 , pp. 587-590
    • Chopra, I.1
  • 84
    • 33947260670 scopus 로고    scopus 로고
    • Use of hydrogen peroxide vapor for deactivation of Mycobacterium tuberculosis in a biological safety cabinet and a room
    • Hall L., Otter J.A., Chewins J., Wengenack N.L. Use of hydrogen peroxide vapor for deactivation of Mycobacterium tuberculosis in a biological safety cabinet and a room. J Clin Microbiol 2007, 45:810-815.
    • (2007) J Clin Microbiol , vol.45 , pp. 810-815
    • Hall, L.1    Otter, J.A.2    Chewins, J.3    Wengenack, N.L.4
  • 85
    • 79951850077 scopus 로고    scopus 로고
    • Testing standards for sporicides
    • Humphreys P.N. Testing standards for sporicides. J Hosp Infect 2011, 77:193-198.
    • (2011) J Hosp Infect , vol.77 , pp. 193-198
    • Humphreys, P.N.1
  • 86
    • 84870990223 scopus 로고    scopus 로고
    • Identification and control of an outbreak of gentamicin-resistant
    • methicillin-susceptible Staphylococcus aureus on a neonatal unit. 13th International Symposium on Staphylococci and Staphylococcal Infection (ISSSI), Cairns, Australia
    • Otter JA, Davies B, Klein J, Watts TL, Kearns AM, French GL. Identification and control of an outbreak of gentamicin-resistant, methicillin-susceptible Staphylococcus aureus on a neonatal unit. 13th International Symposium on Staphylococci and Staphylococcal Infection (ISSSI), Cairns, Australia, 2008.
    • (2008)
    • Otter, J.A.1    Davies, B.2    Klein, J.3    Watts, T.L.4    Kearns, A.M.5    French, G.L.6
  • 87
    • 79953747551 scopus 로고    scopus 로고
    • Hydrogen peroxide vapour (HPV) inactivation of adenovirus
    • Berrie E., Andrews L., Yezli S., Otter J.A. Hydrogen peroxide vapour (HPV) inactivation of adenovirus. Lett Appl Microbiol 2011, 52:555-558.
    • (2011) Lett Appl Microbiol , vol.52 , pp. 555-558
    • Berrie, E.1    Andrews, L.2    Yezli, S.3    Otter, J.A.4
  • 88
    • 84870981298 scopus 로고    scopus 로고
    • Hydrogen peroxide vapor (HPV) inactivation of feline calicivirus, a surrogate for norovirus - an update. Infection Prevention Society Annual Meeting
    • Goyal SM, Chander Y, Yezli S, Otter JA. Hydrogen peroxide vapor (HPV) inactivation of feline calicivirus, a surrogate for norovirus - an update. Infection Prevention Society Annual Meeting. 2011.
    • (2011)
    • Goyal, S.M.1    Chander, Y.2    Yezli, S.3    Otter, J.A.4
  • 89
    • 71749085453 scopus 로고    scopus 로고
    • Evaluation of hydrogen peroxide gaseous disinfection systems to decontaminate viruses
    • Pottage T., Richardson C., Parks S., Walker J.T., Bennett A.M. Evaluation of hydrogen peroxide gaseous disinfection systems to decontaminate viruses. J Hosp Infect 2010, 74:55-61.
    • (2010) J Hosp Infect , vol.74 , pp. 55-61
    • Pottage, T.1    Richardson, C.2    Parks, S.3    Walker, J.T.4    Bennett, A.M.5
  • 90
    • 84455205575 scopus 로고    scopus 로고
    • Activity in vitro of hydrogen peroxide vapour against Clostridium difficile spores
    • Barbut F., Yezli S., Otter J.A. Activity in vitro of hydrogen peroxide vapour against Clostridium difficile spores. J Hosp Infect 2012, 80:85-87.
    • (2012) J Hosp Infect , vol.80 , pp. 85-87
    • Barbut, F.1    Yezli, S.2    Otter, J.A.3
  • 91
    • 84856009454 scopus 로고    scopus 로고
    • Hydrogen peroxide vapour decontamination of surfaces artificially contaminated with norovirus surrogate feline calicivirus
    • Bentley K., Dove B.K., Parks S.R., Walker J.T., Bennett A.M. Hydrogen peroxide vapour decontamination of surfaces artificially contaminated with norovirus surrogate feline calicivirus. J Hosp Infect 2012, 80:116-121.
    • (2012) J Hosp Infect , vol.80 , pp. 116-121
    • Bentley, K.1    Dove, B.K.2    Parks, S.R.3    Walker, J.T.4    Bennett, A.M.5
  • 92
    • 84867734049 scopus 로고    scopus 로고
    • Impact of the suspending medium on susceptibility of meticillin-resistant Staphylococcus aureus to hydrogen peroxide vapour decontamination
    • [Epub ahead of print]
    • Otter J.A., Yezli S., French G.L. Impact of the suspending medium on susceptibility of meticillin-resistant Staphylococcus aureus to hydrogen peroxide vapour decontamination. J Hosp Infect 2012 Sep 24, [Epub ahead of print]. http://dx.doi.org/10.1016/j.jhin.2012.08.006.
    • (2012) J Hosp Infect
    • Otter, J.A.1    Yezli, S.2    French, G.L.3
  • 93
    • 84863875062 scopus 로고    scopus 로고
    • Control of an outbreak of Acinetobacter baumannii infections using vaporized hydrogen peroxide
    • Chmielarczyk A., Higgins P.G., Wojkowska-Mach J., et al. Control of an outbreak of Acinetobacter baumannii infections using vaporized hydrogen peroxide. J Hosp Infect 2012, 81:239-245.
    • (2012) J Hosp Infect , vol.81 , pp. 239-245
    • Chmielarczyk, A.1    Higgins, P.G.2    Wojkowska-Mach, J.3
  • 94
    • 84871011108 scopus 로고    scopus 로고
    • Impact of an intensive terminal cleaning and disinfection (C/D) protocol involving selected hospital rooms on endemic nosocomial infection (NI) rates of common pathogens at a tertiary care medical center. 5th Decennial Meeting of the Society for Healthcare Epidemiology of America (SHEA), Atlanta, GA, USA. Abstract LB6.
    • Manian FA, Griesenauer S, Senkel D. Impact of an intensive terminal cleaning and disinfection (C/D) protocol involving selected hospital rooms on endemic nosocomial infection (NI) rates of common pathogens at a tertiary care medical center. 5th Decennial Meeting of the Society for Healthcare Epidemiology of America (SHEA), Atlanta, GA, USA. Abstract LB6. 2010.
    • (2010)
    • Manian, F.A.1    Griesenauer, S.2    Senkel, D.3
  • 95
    • 84871190132 scopus 로고    scopus 로고
    • An evaluation of environmental decontamination with hydrogen peroxide vapor for reducing the risk of patient acquisition of multidrug-resistant organisms
    • [Epub ahead of print]
    • Passaretti C.L., Otter J.A., Reich N.G., et al. An evaluation of environmental decontamination with hydrogen peroxide vapor for reducing the risk of patient acquisition of multidrug-resistant organisms. Clin Infect Dis 2012 Oct 5, [Epub ahead of print].
    • (2012) Clin Infect Dis
    • Passaretti, C.L.1    Otter, J.A.2    Reich, N.G.3
  • 96
    • 84871027809 scopus 로고    scopus 로고
    • Department of Health, NHS Purchasing and Supply Agency (UK). HCAI Technology Innovation Programme. Showcase Hospitals Report Number 3. The Bioquell Hydrogen Peroxide Vapour (HPV) Disinfection System
    • Department of Health, NHS Purchasing and Supply Agency (UK). HCAI Technology Innovation Programme. Showcase Hospitals Report Number 3. The Bioquell Hydrogen Peroxide Vapour (HPV) Disinfection System. 2009.
    • (2009)
  • 97
    • 77951656508 scopus 로고    scopus 로고
    • Cycle times for hydrogen peroxide vapour decontamination
    • Otter J.A., Yezli S. Cycle times for hydrogen peroxide vapour decontamination. Can J Microbiol 2010, 56:356-357.
    • (2010) Can J Microbiol , vol.56 , pp. 356-357
    • Otter, J.A.1    Yezli, S.2
  • 98
    • 84871022328 scopus 로고    scopus 로고
    • Environmental Protection Agency (USA). Compatibility of material and electronic equipment with hydrogen peroxide and chlorine dioxide fumigation. Assessment and evaluation report.
    • Environmental Protection Agency (USA). Compatibility of material and electronic equipment with hydrogen peroxide and chlorine dioxide fumigation. Assessment and evaluation report. 2010.
    • (2010)
  • 99
    • 79960701617 scopus 로고    scopus 로고
    • Terminal decontamination of patient rooms using an automated mobile UV light unit
    • Boyce J.M., Havill N.L., Moore B.A. Terminal decontamination of patient rooms using an automated mobile UV light unit. Infect Control Hosp Epidemiol 2011, 32:737-742.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 737-742
    • Boyce, J.M.1    Havill, N.L.2    Moore, B.A.3
  • 100
    • 77955103443 scopus 로고    scopus 로고
    • Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms
    • Nerandzic M.M., Cadnum J.L., Pultz M.J., Donskey C.J. Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms. BMC Infect Dis 2010, 10:197.
    • (2010) BMC Infect Dis , vol.10 , pp. 197
    • Nerandzic, M.M.1    Cadnum, J.L.2    Pultz, M.J.3    Donskey, C.J.4
  • 102
    • 84870983429 scopus 로고    scopus 로고
    • Elimination of Clostridium difficile infections (CDI) by illumination? Surface disinfection by ultraviolet light treatment
    • Pettis A.M. Elimination of Clostridium difficile infections (CDI) by illumination? Surface disinfection by ultraviolet light treatment. Am J Infect Control 2010, 38:e16-e17.
    • (2010) Am J Infect Control , vol.38
    • Pettis, A.M.1
  • 103
    • 74949087876 scopus 로고    scopus 로고
    • The history of ultraviolet germicidal irradiation for air disinfection
    • Reeda N.G. The history of ultraviolet germicidal irradiation for air disinfection. Public Health Rep 2010, 125:15-27.
    • (2010) Public Health Rep , vol.125 , pp. 15-27
    • Reeda, N.G.1
  • 104
    • 77953010366 scopus 로고    scopus 로고
    • Applications of ultraviolet germicidal irradiation disinfection in healthcare facilities: effective adjunct, but not stand-alone technology
    • Memarzadeh F., Olmsted R.N., Bartley J.M. Applications of ultraviolet germicidal irradiation disinfection in healthcare facilities: effective adjunct, but not stand-alone technology. Am J Infect Control 2010, 38:S13-S24.
    • (2010) Am J Infect Control , vol.38
    • Memarzadeh, F.1    Olmsted, R.N.2    Bartley, J.M.3
  • 105
    • 84870976542 scopus 로고    scopus 로고
    • Enhanced environmental disinfection systems
    • ECRI (Emergency Care Research Institute)
    • Enhanced environmental disinfection systems. Health Devices 2011, 40:150-162. ECRI (Emergency Care Research Institute).
    • (2011) Health Devices , vol.40 , pp. 150-162
  • 106
    • 58149469077 scopus 로고    scopus 로고
    • Monitoring ultraviolet lamps in biological safety cabinets with cultures of standard bacterial strains on TSA blood agar
    • Harrington B.J., Valigosky M. Monitoring ultraviolet lamps in biological safety cabinets with cultures of standard bacterial strains on TSA blood agar. Labmedicine 2007, 38:165-168.
    • (2007) Labmedicine , vol.38 , pp. 165-168
    • Harrington, B.J.1    Valigosky, M.2
  • 107
    • 0036131486 scopus 로고    scopus 로고
    • Assessment and characterization of degradation effect for the varied degrees of ultra-violet radiation onto the collagen-bonded polypropylene non-woven fabric surfaces
    • Tyan Y.C., Liao J.D., Klauser R., IeD Wu, Weng C.C. Assessment and characterization of degradation effect for the varied degrees of ultra-violet radiation onto the collagen-bonded polypropylene non-woven fabric surfaces. Biomaterials 2002, 23:65-76.
    • (2002) Biomaterials , vol.23 , pp. 65-76
    • Tyan, Y.C.1    Liao, J.D.2    Klauser, R.3    IeD, W.4    Weng, C.C.5
  • 109
    • 84871000391 scopus 로고    scopus 로고
    • The use of portable pulsed xenon ultraviolet light (PPX-UV) after terminal cleaning was associated with a dramatic decrease in the hospital-associated Clostridium difficile infection (HA-CDI) rate in a community hospital. Infectious Diseases Society of America (IDSA) Annual Meeting. Abstract 342.
    • Levin J, Parrish C, Riley L, English D. The use of portable pulsed xenon ultraviolet light (PPX-UV) after terminal cleaning was associated with a dramatic decrease in the hospital-associated Clostridium difficile infection (HA-CDI) rate in a community hospital. Infectious Diseases Society of America (IDSA) Annual Meeting. Abstract 342. 2011.
    • (2011)
    • Levin, J.1    Parrish, C.2    Riley, L.3    English, D.4
  • 110
    • 52149095461 scopus 로고    scopus 로고
    • Ozone gas is an effective and practical antibacterial agent
    • Sharma M., Hudson J.B. Ozone gas is an effective and practical antibacterial agent. Am J Infect Control 2008, 36:559-563.
    • (2008) Am J Infect Control , vol.36 , pp. 559-563
    • Sharma, M.1    Hudson, J.B.2
  • 111
    • 69249122820 scopus 로고    scopus 로고
    • Application of a novel decontamination process using gaseous ozone
    • Moat J., Cargill J., Shone J., Upton M. Application of a novel decontamination process using gaseous ozone. Can J Microbiol 2009, 55:928-933.
    • (2009) Can J Microbiol , vol.55 , pp. 928-933
    • Moat, J.1    Cargill, J.2    Shone, J.3    Upton, M.4
  • 112
    • 0041464723 scopus 로고    scopus 로고
    • Surface germicidal effects of ozone for microorganisms
    • Li C.S., Wang Y.C. Surface germicidal effects of ozone for microorganisms. AIHA J (Fairfax, Va) 2003, 64:533-537.
    • (2003) AIHA J (Fairfax, Va) , vol.64 , pp. 533-537
    • Li, C.S.1    Wang, Y.C.2
  • 113
    • 84870981588 scopus 로고    scopus 로고
    • Occupational Safety and Health Administration (OSHA). Occupational safety and health guideline for hydrogen peroxide. Washington, DC: US Department of Labor; not dated.
    • Occupational Safety and Health Administration (OSHA). Occupational safety and health guideline for hydrogen peroxide. Washington, DC: US Department of Labor; not dated.
  • 114
    • 84870990283 scopus 로고    scopus 로고
    • Executive and Safety Executive. EH40/2005 Workplace exposure limits. Bootle, UK: HSE; 2005.
    • Executive and Safety Executive. EH40/2005 Workplace exposure limits. Bootle, UK: HSE; 2005.
  • 115
    • 84455202344 scopus 로고    scopus 로고
    • Evaluation of vaporized hydrogen peroxide, Citrox and pH neutral Ecasol for decontamination of an enclosed area: a pilot study
    • Galvin S., Boyle M., Russell R.J., et al. Evaluation of vaporized hydrogen peroxide, Citrox and pH neutral Ecasol for decontamination of an enclosed area: a pilot study. J Hosp Infect 2012, 80:67-70.
    • (2012) J Hosp Infect , vol.80 , pp. 67-70
    • Galvin, S.1    Boyle, M.2    Russell, R.J.3
  • 116
    • 33750527152 scopus 로고    scopus 로고
    • Efficacy of super-oxidized water fogging in environmental decontamination
    • Clark J., Barrett S.P., Rogers M., Stapleton R. Efficacy of super-oxidized water fogging in environmental decontamination. J Hosp Infect 2006, 64:386-390.
    • (2006) J Hosp Infect , vol.64 , pp. 386-390
    • Clark, J.1    Barrett, S.P.2    Rogers, M.3    Stapleton, R.4
  • 117
    • 84856000222 scopus 로고    scopus 로고
    • Virucidal efficacy of hydrogen peroxide vapour disinfection
    • Tuladhar E., Terpstra P., Koopmans M., Duizer E. Virucidal efficacy of hydrogen peroxide vapour disinfection. J Hosp Infect 2012, 80:110-115.
    • (2012) J Hosp Infect , vol.80 , pp. 110-115
    • Tuladhar, E.1    Terpstra, P.2    Koopmans, M.3    Duizer, E.4
  • 118
    • 79958732607 scopus 로고    scopus 로고
    • Hydrogen peroxide vapour for decontaminating air-conditioning ducts and rooms of an emergency complex in northern India: time to move on
    • Taneja N., Biswal M., Kumar A., et al. Hydrogen peroxide vapour for decontaminating air-conditioning ducts and rooms of an emergency complex in northern India: time to move on. J Hosp Infect 2011, 78:200-203.
    • (2011) J Hosp Infect , vol.78 , pp. 200-203
    • Taneja, N.1    Biswal, M.2    Kumar, A.3
  • 119
    • 79958760239 scopus 로고    scopus 로고
    • Reducing microbial contamination of surfaces using RelyOn Virkosept aerosol spray
    • De Lorenzi S., Romanini L., Finzi G., Barrai I., Salvatorelli G. Reducing microbial contamination of surfaces using RelyOn Virkosept aerosol spray. J Hosp Infect 2011, 78:240-241.
    • (2011) J Hosp Infect , vol.78 , pp. 240-241
    • De Lorenzi, S.1    Romanini, L.2    Finzi, G.3    Barrai, I.4    Salvatorelli, G.5
  • 120
    • 77957895054 scopus 로고    scopus 로고
    • Inactivation of methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant Enterococcus faecium (VRE) on various environmental surfaces by mist application of a stabilized chlorine dioxide and quaternary ammonium compound-based disinfectant
    • Callahan K.L., Beck N.K., Duffield E.A., Shin G., Meschke J.S. Inactivation of methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant Enterococcus faecium (VRE) on various environmental surfaces by mist application of a stabilized chlorine dioxide and quaternary ammonium compound-based disinfectant. J Occup Environ Hyg 2010, 7:529-534.
    • (2010) J Occup Environ Hyg , vol.7 , pp. 529-534
    • Callahan, K.L.1    Beck, N.K.2    Duffield, E.A.3    Shin, G.4    Meschke, J.S.5
  • 121
    • 63249125724 scopus 로고    scopus 로고
    • Can hospital computers be disinfected using a hand-held UV light source?
    • Sweeney C.P., Dancer S.J. Can hospital computers be disinfected using a hand-held UV light source?. J Hosp Infect 2009, 72:92-94.
    • (2009) J Hosp Infect , vol.72 , pp. 92-94
    • Sweeney, C.P.1    Dancer, S.J.2
  • 122
    • 75949113756 scopus 로고    scopus 로고
    • Evaluation of ultraviolet C for disinfection of endocavitary ultrasound transducers persistently contaminated despite probe covers
    • Kac G., Podglajen I., Si-Mohamed A., Rodi A., Grataloup C., Meyer G. Evaluation of ultraviolet C for disinfection of endocavitary ultrasound transducers persistently contaminated despite probe covers. Infect Control Hosp Epidemiol 2010, 31:165-170.
    • (2010) Infect Control Hosp Epidemiol , vol.31 , pp. 165-170
    • Kac, G.1    Podglajen, I.2    Si-Mohamed, A.3    Rodi, A.4    Grataloup, C.5    Meyer, G.6
  • 123
    • 67651092224 scopus 로고    scopus 로고
    • Feasibility of routinely using hydrogen peroxide vapor to decontaminate rooms in a busy United States hospital
    • Otter J.A., Puchowicz M., Ryan D., et al. Feasibility of routinely using hydrogen peroxide vapor to decontaminate rooms in a busy United States hospital. Infect Control Hosp Epidemiol 2009, 30:574-577.
    • (2009) Infect Control Hosp Epidemiol , vol.30 , pp. 574-577
    • Otter, J.A.1    Puchowicz, M.2    Ryan, D.3
  • 124
    • 84859357879 scopus 로고    scopus 로고
    • Comparison of the microbiological efficacy of hydrogen peroxide vapor and ultraviolet light processes for room decontamination
    • Havill N.L., Moore B.A., Boyce J.M. Comparison of the microbiological efficacy of hydrogen peroxide vapor and ultraviolet light processes for room decontamination. Infect Control Hosp Epidemiol 2012, 33:507-512.
    • (2012) Infect Control Hosp Epidemiol , vol.33 , pp. 507-512
    • Havill, N.L.1    Moore, B.A.2    Boyce, J.M.3
  • 125
    • 84857137929 scopus 로고    scopus 로고
    • Are commercially available Geobacillus stearothermophilus biological indicators an appropriate standard for hydrogen peroxide vapour systems in hospitals?
    • Otter J.A., Yezli S. Are commercially available Geobacillus stearothermophilus biological indicators an appropriate standard for hydrogen peroxide vapour systems in hospitals?. J Hosp Infect 2012, 80:272-273.
    • (2012) J Hosp Infect , vol.80 , pp. 272-273
    • Otter, J.A.1    Yezli, S.2
  • 126
    • 84455199734 scopus 로고    scopus 로고
    • Presence of biofilm containing viable multiresistant organisms despite terminal cleaning on clinical surfaces in an intensive care unit
    • Vickery K., Deva A., Jacombs A., Allan J., Valente P., Gosbell I.B. Presence of biofilm containing viable multiresistant organisms despite terminal cleaning on clinical surfaces in an intensive care unit. J Hosp Infect 2012, 80:52-55.
    • (2012) J Hosp Infect , vol.80 , pp. 52-55
    • Vickery, K.1    Deva, A.2    Jacombs, A.3    Allan, J.4    Valente, P.5    Gosbell, I.B.6
  • 127
    • 50249133232 scopus 로고    scopus 로고
    • Efficacy of common hospital biocides with biofilms of multi-drug resistant clinical isolates
    • Smith K., Hunter I.S. Efficacy of common hospital biocides with biofilms of multi-drug resistant clinical isolates. J Med Microbiol 2008, 57:966-973.
    • (2008) J Med Microbiol , vol.57 , pp. 966-973
    • Smith, K.1    Hunter, I.S.2
  • 128
    • 84871011513 scopus 로고    scopus 로고
    • Environmental Protection Agency (USA). Standard operating procedure for AOAC use dilution method for testing disinfectants. Fort Meade, MD: EPA; 2010.
    • Environmental Protection Agency (USA). Standard operating procedure for AOAC use dilution method for testing disinfectants. Fort Meade, MD: EPA; 2010.
  • 129
    • 84871014414 scopus 로고    scopus 로고
    • Association for Professionals in Infection Control and Epidemiology (APIC), Association for the Healthcare Environment (AHE). SHEA, APIC and AHE respond to EPA regarding fogging applications. Arlington, VA: SHEA
    • Society for Healthcare Epidemiology of America (SHEA), Association for Professionals in Infection Control and Epidemiology (APIC), Association for the Healthcare Environment (AHE). SHEA, APIC and AHE respond to EPA regarding fogging applications. Arlington, VA: SHEA; 2011.
    • (2011) Society for Healthcare Epidemiology of America (SHEA)
  • 130
    • 84870995846 scopus 로고    scopus 로고
    • Environmental Protection Agency (USA). EPA issues order to NJ hospital group. Washington, DC: EPA
    • Environmental Protection Agency (USA). EPA issues order to NJ hospital group. Washington, DC: EPA; 2011.
    • (2011)
  • 131
    • 84871027091 scopus 로고    scopus 로고
    • Agence Française de Sécurité Sanitaire des Produits de Santé (AFSSAPS). Appareils de désinfection des surfaces par voie aerienne. Paris: AFSSAPS
    • Agence Française de Sécurité Sanitaire des Produits de Santé (AFSSAPS). Appareils de désinfection des surfaces par voie aerienne. Paris: AFSSAPS; 2011.
    • (2011)
  • 132
    • 79951851123 scopus 로고    scopus 로고
    • Regulation of sporicides under the European Biocidal Products Directive
    • Low A. Regulation of sporicides under the European Biocidal Products Directive. J Hosp Infect 2011, 77:189-192.
    • (2011) J Hosp Infect , vol.77 , pp. 189-192
    • Low, A.1
  • 133
    • 84870995498 scopus 로고    scopus 로고
    • Department of Health, Health Protection Agency (UK). Clostridium difficile: how to deal with the problem. London: HPA
    • Department of Health, Health Protection Agency (UK). Clostridium difficile: how to deal with the problem. London: HPA; 2009.
    • (2009)
  • 134
    • 79951856425 scopus 로고    scopus 로고
    • Currently available sporicides for use in healthcare, and their limitations
    • Fraise A. Currently available sporicides for use in healthcare, and their limitations. J Hosp Infect 2011, 77:210-212.
    • (2011) J Hosp Infect , vol.77 , pp. 210-212
    • Fraise, A.1
  • 136
    • 0032879855 scopus 로고    scopus 로고
    • Mopping up hospital infection
    • Dancer S.J. Mopping up hospital infection. J Hosp Infect 1999, 43:85-100.
    • (1999) J Hosp Infect , vol.43 , pp. 85-100
    • Dancer, S.J.1
  • 138
    • 0023922339 scopus 로고
    • Contamination of detergent cleaning solutions during hospital cleaning
    • Werry C., Lawrence J.M., Sanderson P.J. Contamination of detergent cleaning solutions during hospital cleaning. J Hosp Infect 1988, 11:44-49.
    • (1988) J Hosp Infect , vol.11 , pp. 44-49
    • Werry, C.1    Lawrence, J.M.2    Sanderson, P.J.3
  • 139
    • 34250842651 scopus 로고    scopus 로고
    • Impact of infection control interventions and antibiotic use on hospital MRSA: a multivariate interrupted time-series analysis
    • Mahamat A., MacKenzie F.M., Brooker K., Monnet D.L., Daures J.P., Gould I.M. Impact of infection control interventions and antibiotic use on hospital MRSA: a multivariate interrupted time-series analysis. Int J Antimicrob Agents 2007, 30:169-176.
    • (2007) Int J Antimicrob Agents , vol.30 , pp. 169-176
    • Mahamat, A.1    MacKenzie, F.M.2    Brooker, K.3    Monnet, D.L.4    Daures, J.P.5    Gould, I.M.6
  • 140
    • 0035174416 scopus 로고    scopus 로고
    • Prospective evaluation of environmental contamination by Clostridium difficile in isolation side rooms
    • Verity P., Wilcox M.H., Fawley W., Parnell P. Prospective evaluation of environmental contamination by Clostridium difficile in isolation side rooms. J Hosp Infect 2001, 49:204-209.
    • (2001) J Hosp Infect , vol.49 , pp. 204-209
    • Verity, P.1    Wilcox, M.H.2    Fawley, W.3    Parnell, P.4
  • 141
    • 0034452451 scopus 로고    scopus 로고
    • Environmental control to reduce transmission of Clostridium difficile
    • Mayfield J.L., Leet T., Miller J., Mundy L.M. Environmental control to reduce transmission of Clostridium difficile. Clin Infect Dis 2000, 31:995-1000.
    • (2000) Clin Infect Dis , vol.31 , pp. 995-1000
    • Mayfield, J.L.1    Leet, T.2    Miller, J.3    Mundy, L.M.4
  • 142
    • 20044390054 scopus 로고    scopus 로고
    • Decontamination with vaporized hydrogen peroxide is effective against Mycobacterium tuberculosis
    • Kahnert A., Seiler P., Stein M., Aze B., McDonnell G., Kaufmann S.H. Decontamination with vaporized hydrogen peroxide is effective against Mycobacterium tuberculosis. Lett Appl Microbiol 2005, 40:448-452.
    • (2005) Lett Appl Microbiol , vol.40 , pp. 448-452
    • Kahnert, A.1    Seiler, P.2    Stein, M.3    Aze, B.4    McDonnell, G.5    Kaufmann, S.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.