메뉴 건너뛰기




Volumn 62, Issue 2, 2006, Pages 149-155

Decontamination of rooms, medical equipment and ambulances using an aerosol of hydrogen peroxide disinfectant

Author keywords

Ambulance decontamination; Hydrogen peroxide fume decontamination; Medical equipment decontamination; Room decontamination; Spore test

Indexed keywords

DISINFECTANT AGENT; HYDROGEN PEROXIDE;

EID: 30344456669     PISSN: 01956701     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhin.2005.07.020     Document Type: Article
Times cited : (142)

References (11)
  • 1
    • 30344466122 scopus 로고    scopus 로고
    • Chemical disinfection liquids for technical use in medicine
    • Oslo: Norwegian Medicines Agency. Norwegian Medicines Agency
    • Norwegian Medicines Agency Chemical disinfection liquids for technical use in medicine 2002 Norwegian Medicines Agency Oslo
    • (2002)
  • 2
    • 30344465480 scopus 로고    scopus 로고
    • Technical disinfection of medical instruments and devices
    • B.M. Andersen editor Ullevaal University Hospital Oslo
    • B.M. Andersen K. Hochlin N. Solheim et al. Technical disinfection of medical instruments and devices In: B.M. Andersen editor Handbook in hygiene and infection control 2003 Ullevaal University Hospital Oslo 347-355
    • (2003) Handbook in Hygiene and Infection Control , pp. 347-355
    • Andersen, B.M.1    Hochlin, K.2    Solheim, N.3
  • 3
    • 0032965865 scopus 로고    scopus 로고
    • A Norwegian nosocomial outbreak of methicillin-resistant Staphylococcus aureus resistant to fusidic acid and susceptible to other antistaphylococcal agents
    • B.M. Andersen K. Bergh M. Steinbakk et al. A Norwegian nosocomial outbreak of methicillin-resistant Staphylococcus aureus resistant to fusidic acid and susceptible to other antistaphylococcal agents J Hosp Infect 41 1999 123-132
    • (1999) J Hosp Infect , vol.41 , pp. 123-132
    • Andersen, B.M.1    Bergh, K.2    Steinbakk, M.3
  • 4
    • 0036369468 scopus 로고    scopus 로고
    • Spread of methicillin-resistant Staphylococcus aureus in a neonatal intensive unit associated with understaffing, overcrowding and mixing of patients
    • B.M. Andersen R. Lindemann K. Bergh et al. Spread of methicillin-resistant Staphylococcus aureus in a neonatal intensive unit associated with understaffing, overcrowding and mixing of patients J Hosp Infect 1 2002 1-7
    • (2002) J Hosp Infect , vol.1 , pp. 1-7
    • Andersen, B.M.1    Lindemann, R.2    Bergh, K.3
  • 6
    • 0009519451 scopus 로고    scopus 로고
    • Selection and use of disinfectants in healthcare
    • C.G. Mayhall editor 2nd ed William and Wilkins London
    • W.A. Rutala Selection and use of disinfectants in healthcare In: C.G. Mayhall editor Hospital epidemiology and infection control 2nd ed 1999 William and Wilkins London 1161-1187
    • (1999) Hospital Epidemiology and Infection Control , pp. 1161-1187
    • Rutala, W.A.1
  • 7
    • 0034976089 scopus 로고    scopus 로고
    • The emerging nosocomial pathogens Cryptosporidium, Escherichia coli O 157:H7, Helicobacter pylori, and hepatitis C: Epidemiology, environmental survival, efficacy of disinfection, and control measures
    • D.J. Weber W.A. Rutala The emerging nosocomial pathogens Cryptosporidium, Escherichia coli O 157:H7, Helicobacter pylori, and hepatitis C: Epidemiology, environmental survival, efficacy of disinfection, and control measures Infect Control Hosp Epidemiol 22 2001 306-315
    • (2001) Infect Control Hosp Epidemiol , vol.22 , pp. 306-315
    • Weber, D.J.1    Rutala, W.A.2
  • 8
    • 0020583515 scopus 로고
    • The bactericidal, fungicidal, and sporicidal properties of hydrogen peroxide and peracetic acid
    • M. Baldry The bactericidal, fungicidal, and sporicidal properties of hydrogen peroxide and peracetic acid J Appl Bacteriol 54 1983 417-423
    • (1983) J Appl Bacteriol , vol.54 , pp. 417-423
    • Baldry, M.1
  • 10
    • 0000571719 scopus 로고    scopus 로고
    • Microbial susceptibility and resistance to biocides
    • A.D. Russel J.R. Furr J.-Y. Maillard Microbial susceptibility and resistance to biocides AMS News 63 1997 481-487
    • (1997) AMS News , vol.63 , pp. 481-487
    • Russel, A.D.1    Furr, J.R.2    Maillard, J.-Y.3
  • 11
    • 2342485984 scopus 로고    scopus 로고
    • Tackling contamination of the hospital environment by methicillin-resistant Staphylococcus aureus (MRSA): A comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination
    • G.L. French J.A. Otter K.P. Shannon et al. Tackling contamination of the hospital environment by methicillin-resistant Staphylococcus aureus (MRSA): A comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination J Hosp Infect 57 2004 31-37
    • (2004) J Hosp Infect , vol.57 , pp. 31-37
    • French, G.L.1    Otter, J.A.2    Shannon, K.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.