메뉴 건너뛰기




Volumn 101, Issue 14, 2012, Pages

Minimum domain size and stability in carbon nanotube-ferroelectric devices

Author keywords

[No Author keywords available]

Indexed keywords

DEFECT PINNING; DOMAIN SIZE; FERROELECTRIC DOMAINS; FIELD GEOMETRY; NANO DOMAIN; THEORETICAL PREDICTION;

EID: 84867529307     PISSN: 00036951     EISSN: None     Source Type: Journal    
DOI: 10.1063/1.4757880     Document Type: Article
Times cited : (15)

References (29)
  • 1
    • 35348846979 scopus 로고
    • 10.1126/science.246.4936.1400
    • J. F. Scott and C. A. P. de Araujo, Science 246, 1400 (1989). 10.1126/science.246.4936.1400
    • (1989) Science , vol.246 , pp. 1400
    • Scott, J.F.1    De Araujo, C.A.P.2
  • 14
    • 84867533617 scopus 로고    scopus 로고
    • CNTs from SES Research were suspended in deionized H 2O with sodium dodecylbenzenesulfonate surfactant, then dispersed by spin-coating (one 20 μl drop, 3 min wait, 4000 rps for 30 s, 3 repeats)
    • CNTs from SES Research were suspended in deionized H 2O with sodium dodecylbenzenesulfonate surfactant, then dispersed by spin-coating (one 20 μl drop, 3 min wait, 4000 rps for 30 s, 3 repeats).
  • 15
    • 84867537481 scopus 로고    scopus 로고
    • Switching pulses to the electrodes/CNT were applied via ZN50R-10-BeCu needle probes (Lake Shore CPX probe station, Agilent 81110A pulse generator). Switching pulses to the Bruker MESP tips were applied directly on the Veeco Dimension V AFM. For PFM imaging, typical parameters were 20 kHz drive frequency, 3000 mV drive amplitude, and 3 μm/s tivelocity
    • Switching pulses to the electrodes/CNT were applied via ZN50R-10-BeCu needle probes (Lake Shore CPX probe station, Agilent 81110A pulse generator). Switching pulses to the Bruker MESP tips were applied directly on the Veeco Dimension V AFM. For PFM imaging, typical parameters were 20 kHz drive frequency, 3000 mV drive amplitude, and 3 μm/s tip velocity.
  • 18
    • 84867530924 scopus 로고    scopus 로고
    • For the AFM-written domains, the radius was extracted from the total domain area obtained from the binarized PFM phase image. For the CNT and electrode-edge-written domains, the average half-width/width was extracted from a linear portion of the domain
    • For the AFM-written domains, the radius was extracted from the total domain area obtained from the binarized PFM phase image. For the CNT and electrode-edge-written domains, the average half-width/width was extracted from a linear portion of the domain.
  • 19
    • 0037085895 scopus 로고    scopus 로고
    • 10.1103/PhysRevB.65.125408
    • S. V. Kalinin and D. A. Bonnell, Phys. Rev. B 65, 125408 (2002). 10.1103/PhysRevB.65.125408
    • (2002) Phys. Rev. B , vol.65 , pp. 125408
    • Kalinin, S.V.1    Bonnell, D.A.2
  • 20
    • 36849130596 scopus 로고
    • 10.1063/1.1722712
    • R. Landauer, J. Appl. Phys. 28, 227 (1957). 10.1063/1.1722712
    • (1957) J. Appl. Phys. , vol.28 , pp. 227
    • Landauer, R.1
  • 21
    • 0042842544 scopus 로고    scopus 로고
    • 10.1063/1.1578529
    • B. Wang and C. H. Woo, J. Appl. Phys. 94, 610 (2003). 10.1063/1.1578529
    • (2003) J. Appl. Phys. , vol.94 , pp. 610
    • Wang, B.1    Woo, C.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.