메뉴 건너뛰기




Volumn 469, Issue 6, 2011, Pages 1621-1626

Avoiding short-term femoral neck fracture with imageless computer navigation for hip resurfacing

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; BONE EROSION; COMPUTER ASSISTED SURGERY; CONFERENCE PAPER; FEMALE; FEMORAL COMPONENT FAILURE; FEMORAL NECK THINNING; FEMORAL STEM RADIOLUCENCY; FEMOROACETABULAR IMPINGEMENT; FEMUR NECK FRACTURE; FOLLOW UP; HIP RADIOGRAPHY; HIP RESURFACING; HIP SURGERY; HUMAN; IMAGELESS COMPUTER NAVIGATION; INCIDENCE; INTESTINE OBSTRUCTION; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; PROSTHESIS FAILURE; SEPSIS; SQUEAKING HIP; STEM MIGRATION; SURGICAL ERROR; SURGICAL INFECTION;

EID: 79959555478     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1007/s11999-010-1607-y     Document Type: Conference Paper
Times cited : (7)

References (37)
  • 3
    • 49549093602 scopus 로고    scopus 로고
    • Eleven years of experience with metal-on-metal hybrid hip resurfacing: A review of 1000 conserve plus
    • Amstutz HC, Le Duff MJ. Eleven years of experience with metal-on-metal hybrid hip resurfacing: a review of 1000 conserve plus. J Arthroplasty 2008;23(6 Suppl 1):36-43.
    • (2008) J Arthroplasty , vol.23 , Issue.6 SUPPL. 1 , pp. 36-43
    • Amstutz, H.C.1    Le Duff, M.J.2
  • 4
    • 34249946018 scopus 로고    scopus 로고
    • The Effects of Technique Changes on Aseptic Loosening of the Femoral Component in Hip Resurfacing. Results of 600 Conserve Plus With a 3 to 9 Year Follow-up
    • DOI 10.1016/j.arth.2006.08.001, PII S0883540306005705
    • Amstutz HC, Le Duff MJ, Campbell PA, Dorey FJ. The effects of technique changes on aseptic loosening of the femoral component in hip resurfacing. Results of 600 Conserve Plus with a 3 to 9 year follow-up. J Arthroplasty. 2007;22:481-489. (Pubitemid 46880181)
    • (2007) Journal of Arthroplasty , vol.22 , Issue.4 , pp. 481-489
    • Amstutz, H.C.1    Le, D.M.J.2    Campbell, P.A.3    Dorey, F.J.4
  • 5
    • 77955740739 scopus 로고    scopus 로고
    • Australian Orthopaedic Association National Joint Replacement Registry. Adelaide, Australia: AOA
    • Australian Orthopaedic Association National Joint Replacement Registry. Annual Report. Adelaide, Australia: AOA; 2009.
    • (2009) Annual Report
  • 6
    • 15044348747 scopus 로고    scopus 로고
    • Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips
    • Back DL, Dalziel R, Young D, Shimmin A. Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips. J Bone Joint Surg Br. 2005;87: 324-329.
    • (2005) J Bone Joint Surg Br , vol.87 , pp. 324-329
    • Back, D.L.1    Dalziel, R.2    Young, D.3    Shimmin, A.4
  • 9
    • 16244401409 scopus 로고    scopus 로고
    • The nonoperative management of periprosthetic fractures associated with the birmingham hip resurfacing procedure
    • DOI 10.1016/j.arth.2004.08.007
    • Cossey AJ, Back DL, Shimmin A, Young D, Spriggins AJ. The nonoperative management of periprosthetic fractures associated with the Birmingham hip resurfacing procedure. J Arthroplasty. 2005;20:358-361. (Pubitemid 40460804)
    • (2005) Journal of Arthroplasty , vol.20 , Issue.3 , pp. 358-361
    • Cossey, A.J.1    Back, D.L.2    Shimmin, A.3    Young, D.4    Spriggins, A.J.5
  • 11
  • 14
    • 41149149865 scopus 로고    scopus 로고
    • Intraoperative navigation in hip surface arthroplasty: A radiographic comparative analysis study
    • Hart R, Svab P, Filan P. Intraoperative navigation in hip surface arthroplasty: a radiographic comparative analysis study. Arch Orthop Trauma Surg. 2008;128:429-434.
    • (2008) Arch Orthop Trauma Surg , vol.128 , pp. 429-434
    • Hart, R.1    Svab, P.2    Filan, P.3
  • 17
    • 70349234507 scopus 로고    scopus 로고
    • Birmingham hip arthroplasty: Five to eight years of prospective multicenter results
    • Khan M, Kuiper JH, Edwards D, Robinson E, Richardson JB. Birmingham hip arthroplasty: five to eight years of prospective multicenter results. J Arthroplasty. 2009;24:1044-1050.
    • (2009) J Arthroplasty , vol.24 , pp. 1044-1050
    • Khan, M.1    Kuiper, J.H.2    Edwards, D.3    Robinson, E.4    Richardson, J.B.5
  • 18
    • 9644290786 scopus 로고    scopus 로고
    • Metal-on-metal total hip arthroplasty: The concerns
    • Macdonald SJ. Metal-on-metal total hip arthroplasty: the concerns. Clin Orthop Relat Res. 2004;429:86-93.
    • (2004) Clin Orthop Relat Res , vol.429 , pp. 86-93
    • Macdonald, S.J.1
  • 19
    • 79751492464 scopus 로고    scopus 로고
    • The Birmingham Hip Resurfacing prosthesis: an independent single surgeon's experience at 7-year follow-up
    • Jan 5 [Epub ahead of print]
    • Madhu TS, Akula MR, Raman RN, Sharma HK, Johnson VG. The Birmingham Hip Resurfacing prosthesis: an independent single surgeon's experience at 7-year follow-up. J Arthroplasty. 2010 Jan 5 [Epub ahead of print].
    • (2010) J Arthroplasty
    • Madhu, T.S.1    Akula, M.R.2    Raman, R.N.3    Sharma, H.K.4    Johnson, V.G.5
  • 20
    • 34848877212 scopus 로고    scopus 로고
    • Femoral Neck Fractures After Metal-on-Metal Total Hip Resurfacing. A Prospective Cohort Study
    • DOI 10.1016/j.arth.2007.05.017, PII S0883540307002781
    • Marker DR, Seyler TM, Jinnah RH, Delanois RE, Ulrich SD, Mont MA. Femoral neck fractures after metal-on-metal total hip resurfacing: a prospective cohort study. J Arthroplasty. 2007; 22(7 Suppl 3):66-71. (Pubitemid 47494612)
    • (2007) Journal of Arthroplasty , vol.22 , Issue.7 SUPPL. , pp. 66-71
    • Marker, D.R.1    Seyler, T.M.2    Jinnah, R.H.3    Delanois, R.E.4    Ulrich, S.D.5    Mont, M.A.6
  • 22
    • 68249098196 scopus 로고    scopus 로고
    • Early clinical failure of the Birmingham metal-on-metal hip resurfacing is associated with metallosis and soft-tissue necrosis
    • Ollivere B, Darrah C, Barker T, Nolan J, Porteous MJ. Early clinical failure of the Birmingham metal-on-metal hip resurfacing is associated with metallosis and soft-tissue necrosis. J Bone Joint Surg Br. 2009;91:1025-1030.
    • (2009) J Bone Joint Surg Br , vol.91 , pp. 1025-1030
    • Ollivere, B.1    Darrah, C.2    Barker, T.3    Nolan, J.4    Porteous, M.J.5
  • 23
    • 77956641114 scopus 로고    scopus 로고
    • A comparison of conventional guidewire alignment jigs with imageless computer navigation in hip resurfacing arthroplasty
    • Olsen M, Chiu M, Gamble P, Boyle RA, Tumia N, Schemitsch EH. A comparison of conventional guidewire alignment jigs with imageless computer navigation in hip resurfacing arthroplasty. J Bone Joint Surg Am.92:1834-1841.
    • J Bone Joint Surg Am , vol.92 , pp. 1834-1841
    • Olsen, M.1    Chiu, M.2    Gamble, P.3    Boyle, R.A.4    Tumia, N.5    Schemitsch, E.H.6
  • 24
    • 62349087812 scopus 로고    scopus 로고
    • The reliability of radiographic assessment of femoral neck-shaft and implant angulation in hip resurfacing arthroplasty
    • Olsen M, Davis ET, Gallie PA, Waddell JP, Schemitsch EH. The reliability of radiographic assessment of femoral neck-shaft and implant angulation in hip resurfacing arthroplasty. J Arthroplasty. 2009;24:333-340.
    • (2009) J Arthroplasty , vol.24 , pp. 333-340
    • Olsen, M.1    Davis, E.T.2    Gallie, P.A.3    Waddell, J.P.4    Schemitsch, E.H.5
  • 25
    • 63049121864 scopus 로고    scopus 로고
    • Imageless computer navigation for placement of the femoral component in resurfacing arthroplasty of the hip
    • Olsen M, Davis ET, Waddell JP, Schemitsch EH. Imageless computer navigation for placement of the femoral component in resurfacing arthroplasty of the hip. J Bone Joint Surg Br. 2009; 91:310-315.
    • (2009) J Bone Joint Surg Br , vol.91 , pp. 310-315
    • Olsen, M.1    Davis, E.T.2    Waddell, J.P.3    Schemitsch, E.H.4
  • 26
    • 67649515091 scopus 로고    scopus 로고
    • Computer navigated hip resurfacing for patients with abnormal femoral anatomy
    • Olsen M, Schemitsch EH. Computer navigated hip resurfacing for patients with abnormal femoral anatomy. Bull NYU Hosp Jt Dis. 2009;67:159-163.
    • (2009) Bull NYU Hosp Jt Dis , vol.67 , pp. 159-163
    • Olsen, M.1    Schemitsch, E.H.2
  • 28
    • 33646825663 scopus 로고    scopus 로고
    • Treatment of the young active patient with osteoarthritis of the hip. A five- To seven-year comparison of hybrid total hip arthroplasty and metal-on-metal resurfacing
    • Pollard TC, Baker RP, Eastaugh-Waring SJ, Bannister GC. Treatment of the young active patient with osteoarthritis of the hip. A five- to seven-year comparison of hybrid total hip arthroplasty and metal-on-metal resurfacing. J Bone Joint Surg Br. 2006;88:592-600.
    • (2006) J Bone Joint Surg Br , vol.88 , pp. 592-600
    • Pollard, T.C.1    Baker, R.P.2    Eastaugh-Waring, S.J.3    Bannister, G.C.4
  • 29
    • 78649326612 scopus 로고    scopus 로고
    • What is the midterm survivorship and function after hip resurfacing?
    • Jan 24 [Epub ahead of print]
    • Rahman L, Muirhead-Allwood SK, Alkinj M. What is the midterm survivorship and function after hip resurfacing? Clin Orthop Relat Res. 2010 Jan 24 [Epub ahead of print].
    • (2010) Clin Orthop Relat Res
    • Rahman, L.1    Muirhead-Allwood, S.K.2    Alkinj, M.3
  • 30
    • 62349118219 scopus 로고    scopus 로고
    • Computer-assisted vs conventional mechanical jig technique in hip resurfacing arthroplasty
    • Resubal JR, Morgan DA. Computer-assisted vs conventional mechanical jig technique in hip resurfacing arthroplasty. J Arthroplasty. 2009;24:341-350.
    • (2009) J Arthroplasty , vol.24 , pp. 341-350
    • Resubal, J.R.1    Morgan, D.A.2
  • 31
    • 49849101720 scopus 로고    scopus 로고
    • Imageless navigation in hip resurfacing: Avoiding component malposition during the surgeon learning curve
    • Romanowski JR, Swank ML. Imageless navigation in hip resurfacing: avoiding component malposition during the surgeon learning curve. J Bone Joint Surg Am. 2008;90 (Suppl 3):65-70.
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.SUPPL. 3 , pp. 65-70
    • Romanowski, J.R.1    Swank, M.L.2
  • 32
    • 64249161668 scopus 로고    scopus 로고
    • Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy
    • Schnurr C, Michael JW, Eysel P, Konig DP. Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy. Int Orthop. 2009;33:365-372.
    • (2009) Int Orthop , vol.33 , pp. 365-372
    • Schnurr, C.1    Michael, J.W.2    Eysel, P.3    Konig, D.P.4
  • 33
    • 49849089116 scopus 로고    scopus 로고
    • Does computer-assisted surgery improve accuracy and decrease the learning curve in hip resurfacing? A radiographic analysis
    • Seyler TM, Lai LP, Sprinkle DI, Ward WG, Jinnah RH. Does computer-assisted surgery improve accuracy and decrease the learning curve in hip resurfacing? A radiographic analysis. J Bone Joint Surg Am. 2008;90(Suppl 3):71-80.
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.SUPPL. 3 , pp. 71-80
    • Seyler, T.M.1    Lai, L.P.2    Sprinkle, D.I.3    Ward, W.G.4    Jinnah, R.H.5
  • 34
    • 17744365971 scopus 로고    scopus 로고
    • Femoral neck fractures following Birmingham hip resurfacing
    • DOI 10.1302/0301-620X.87B4.15498
    • Shimmin AJ, Back D. Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases. J Bone Joint Surg Br. 2005;87:463-464. (Pubitemid 40575766)
    • (2005) Journal of Bone and Joint Surgery - Series B , vol.87 , Issue.4 , pp. 463-464
    • Shimmin, A.J.1    Back, D.2
  • 35
    • 55549108065 scopus 로고    scopus 로고
    • Femoral neck narrowing after metal-on-metal hip resurfacing
    • Spencer S, Carter R, Murray H, Meek RM. Femoral neck narrowing after metal-on-metal hip resurfacing. J Arthroplasty. 2008;23:1105-1109.
    • (2008) J Arthroplasty , vol.23 , pp. 1105-1109
    • Spencer, S.1    Carter, R.2    Murray, H.3    Meek, R.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.