메뉴 건너뛰기




Volumn 20, Issue 1, 2011, Pages 231-238

A multidrug delivery system using a piezoelectrically actuated silicon valve manifold with embedded sensors

Author keywords

Drug delivery; liquid flow; manifold; microvalve; piezoelectric

Indexed keywords

CHRONIC PAIN; CLOSED-LOOP CONTROL; CONTINUOUS FLOWS; DELIVERY SYSTEMS; DRUG DELIVERY SYSTEM; EMBEDDED SENSORS; GLASS SUBSTRATES; LIQUID FLOW; MANIFOLD; MICRO VALVES; MICROMACHINED; PIEZOELECTRIC; PIEZORESISTIVE PRESSURE SENSORS; PRESSURE PROFILES; RESERVOIR VOLUME; SPINAL FLUID PRESSURE; STAINLESS STEEL HOUSING; VALVE SEATS;

EID: 79551597266     PISSN: 10577157     EISSN: None     Source Type: Journal    
DOI: 10.1109/JMEMS.2010.2093566     Document Type: Article
Times cited : (22)

References (31)
  • 2
    • 0142147051 scopus 로고    scopus 로고
    • Pain management: Health economics and quality of life considerations
    • C. J. Phillips, "Pain management: Health economics and quality of life considerations," Drugs, vol. 63, no. 2, pp. 47-50, 2003.
    • (2003) Drugs , vol.63 , Issue.2 , pp. 47-50
    • Phillips, C.J.1
  • 3
    • 0029822588 scopus 로고    scopus 로고
    • Long-term effects of continuous intrathecal opioid treatment in chronic pain of nonmalignant etiology
    • Sep.
    • M.Winkelmuller andW.Winkelmuller, "Long-term effects of continuous intrathecal opioid treatment in chronic pain of nonmalignant etiology," J. Neurosurg., vol. 85, no. 3, pp. 458-467, Sep. 1996.
    • (1996) J. Neurosurg. , vol.85 , Issue.3 , pp. 458-467
    • Winkelmuller, M.1    Winkelmuller, W.2
  • 4
    • 23244431760 scopus 로고    scopus 로고
    • Ziconotide, an intrathecally administered N-type calcium channel antagonist for the treatment of chronic pain
    • Aug.
    • D. P. Wermeling, "Ziconotide, an intrathecally administered N-type calcium channel antagonist for the treatment of chronic pain," Pharmacotherapy, vol. 25, no. 8, pp. 1084-1094, Aug. 2005.
    • (2005) Pharmacotherapy , vol.25 , Issue.8 , pp. 1084-1094
    • Wermeling, D.P.1
  • 5
    • 33750248740 scopus 로고    scopus 로고
    • Neuraxial drug administration: A review of treatment options for anesthesia and analgesia
    • S. A. Schug, D. Saunders, I. Kurowski, and M. J. Paech, "Neuraxial drug administration: A review of treatment options for anesthesia and analgesia," CNS Drugs, vol. 20, no. 11, pp. 917-933, 2006.
    • (2006) CNS Drugs , vol.20 , Issue.11 , pp. 917-933
    • Schug, S.A.1    Saunders, D.2    Kurowski, I.3    Paech, M.J.4
  • 6
    • 0142179214 scopus 로고    scopus 로고
    • Long-term intrathecal opioid therapy with a patient-activated, implanted delivery system for the treatment of refractory cancer pain
    • Oct.
    • R. L. Rauck, D. Cherry, M. F. Boyer, P. Kosek, J. Dunn, and K. Alo, "Long-term intrathecal opioid therapy with a patient-activated, implanted delivery system for the treatment of refractory cancer pain," J. Pain, vol. 4, no. 8, pp. 441-447, Oct. 2003.
    • (2003) J. Pain , vol.4 , Issue.8 , pp. 441-447
    • Rauck, R.L.1    Cherry, D.2    Boyer, M.F.3    Kosek, P.4    Dunn, J.5    Alo, K.6
  • 7
    • 1642566729 scopus 로고    scopus 로고
    • Intrathecal drug delivery for treatment of chronic low back pain: Report from the national outcomes registry for low back pain
    • Mar.
    • T. Deer, I. Chapple, A. Classen, K. Javery, V. Stoker, L. Tonder, and K. Burchiel, "Intrathecal drug delivery for treatment of chronic low back pain: Report from the national outcomes registry for low back pain," Pain Med., vol. 5, no. 1, pp. 6-13, Mar. 2004.
    • (2004) Pain Med. , vol.5 , Issue.1 , pp. 6-13
    • Deer, T.1    Chapple, I.2    Classen, A.3    Javery, K.4    Stoker, V.5    Tonder, L.6    Burchiel, K.7
  • 8
    • 77950867687 scopus 로고    scopus 로고
    • A low power, microvalve regulated architecture for drug delivery systems
    • Feb
    • A. T. Evans, S. Chiravuri, and Y. B. Gianchandani, "A low power, microvalve regulated architecture for drug delivery systems," Biomed. Microdevices, vol. 12, no. 1, pp. 159-168, Feb. 2010.
    • (2010) Biomed. Microdevices , vol.12 , Issue.1 , pp. 159-168
    • Evans, A.T.1    Chiravuri, S.2    Gianchandani, Y.B.3
  • 10
    • 0033012942 scopus 로고    scopus 로고
    • Practical issues when using neuraxial infusion
    • May
    • E. S. Krames, "Practical issues when using neuraxial infusion," Oncology (Williston Park), vol. 13, no. 5 Supplement 2, pp. 37-44, May 1999.
    • (1999) Oncology (Williston Park) , vol.13 , Issue.5 SUPPL. 2 , pp. 37-44
    • Krames, E.S.1
  • 11
    • 85052610323 scopus 로고    scopus 로고
    • Management of chronic back and leg pain by intrathecal drug delivery
    • N. G. Rainov and V. Heidecke, "Management of chronic back and leg pain by intrathecal drug delivery," Acta Neurochir. Suppl., vol. 97, pt. 1, pp. 49-56, 2007.
    • (2007) Acta Neurochir. Suppl. , vol.97 , Issue.PART 1 , pp. 49-56
    • Rainov, N.G.1    Heidecke, V.2
  • 13
    • 0032927561 scopus 로고    scopus 로고
    • A prospective study of long-term intrathecal morphine in the management of chronic nonmalignant pain
    • V. C. Anderson and K. J. Burchiel A prospective study of long-term intrathecal morphine in the management of chronic nonmalignant pain," Neurosurgery, vol. 44, 2, 289-301, 1999.
    • (1999) Neurosurgery , vol.44 , Issue.2 , pp. 289-301
    • Anderson, V.C.1    Burchiel, K.J.2
  • 14
    • 77952787991 scopus 로고    scopus 로고
    • A piezoelectric valve manifold with embedded sensors for multi-drug delivery protocols
    • A. T. Evans, S. Chiravuri, and Y. B. Gianchandani, "A piezoelectric valve manifold with embedded sensors for multi-drug delivery protocols," in Proc. Conf. MEMS, 2010, pp. 1027-1030.
    • (2010) Proc. Conf. MEMS , pp. 1027-1030
    • Evans, A.T.1    Chiravuri, S.2    Gianchandani, Y.B.3
  • 16
    • 0037765106 scopus 로고    scopus 로고
    • Magnetically driven micro ball valves fabricated by multilayer adhesive film bonding
    • Jul.
    • C. Fu, Z. Rummler, and W. Schomburg, "Magnetically driven micro ball valves fabricated by multilayer adhesive film bonding," J. Micromech. Microeng., vol. 13, no. 4, pp. S96-S102, Jul. 2003.
    • (2003) J. Micromech. Microeng. , vol.13 , Issue.4
    • Fu, C.1    Rummler, Z.2    Schomburg, W.3
  • 18
    • 0037390890 scopus 로고    scopus 로고
    • A high-flow thermopneumatic microvalve with improved efficiency and integrated state sensing
    • Apr.
    • C. A. Rich and K. D. Wise, "A high-flow thermopneumatic microvalve with improved efficiency and integrated state sensing," J. Microelectromech. Syst., vol. 12, no. 2, pp. 201-208, Apr. 2003.
    • (2003) J. Microelectromech. Syst. , vol.12 , Issue.2 , pp. 201-208
    • Rich, C.A.1    Wise, K.D.2
  • 20
    • 0033741544 scopus 로고    scopus 로고
    • Thin film shape memory microvalves with adjustable operation temperature
    • May
    • M. Kohl, D. Dittmann, E. Quandt, and B.Winzek, "Thin film shape memory microvalves with adjustable operation temperature," Sens. Actuators A, Phys., vol. 83, no. 1-3, pp. 214-219, May 2000.
    • (2000) Sens. Actuators A, Phys. , vol.83 , Issue.1-3 , pp. 214-219
    • Kohl, M.1    Dittmann, D.2    Quandt, E.3    Winzek, B.4
  • 21
    • 0024764864 scopus 로고
    • Normally closed microvalve and micropump fabricated on a silicon wafer
    • Nov.
    • M. Esashi, S. Shoji, and A. Nakano, "Normally closed microvalve and micropump fabricated on a silicon wafer," Sens. Actuators, vol. 20, no. 1/2, pp. 163-169, Nov. 1989.
    • (1989) Sens. Actuators , vol.20 , Issue.1-2 , pp. 163-169
    • Esashi, M.1    Shoji, S.2    Nakano, A.3
  • 22
    • 4344662676 scopus 로고    scopus 로고
    • An electrostatic, on/off microvalve designed for gas fuel delivery for the MIT microengine
    • Aug.
    • X. Yang, A. Holke, S. A. Jacobson, J. H. Lang, M. A. Schmidt, and S. D. Umans, "An electrostatic, on/off microvalve designed for gas fuel delivery for the MIT microengine," J. Microelectromech. Syst., vol. 13, no. 4, pp. 660-668, Aug. 2004.
    • (2004) J. Microelectromech. Syst. , vol.13 , Issue.4 , pp. 660-668
    • Yang, X.1    Holke, A.2    Jacobson, S.A.3    Lang, J.H.4    Schmidt, M.A.5    Umans, S.D.6
  • 24
    • 0037301524 scopus 로고    scopus 로고
    • A piezoelectric microvalve for compact high-frequency, high-differential pressure hydraulic micropumping systems
    • Feb.
    • D. C. Roberts, H. Li, J. L. Steyn, O. Yaglioglu, S. M. Spearing, M. A. Schmidt, and N. W. Hagood, "A piezoelectric microvalve for compact high-frequency, high-differential pressure hydraulic micropumping systems," J. Microelectromech. Syst., vol. 12, no. 1, pp. 81-92, Feb. 2003.
    • (2003) J. Microelectromech. Syst. , vol.12 , Issue.1 , pp. 81-92
    • Roberts, D.C.1    Li, H.2    Steyn, J.L.3    Yaglioglu, O.4    Spearing, S.M.5    Schmidt, M.A.6    Hagood, N.W.7
  • 25
    • 34948827453 scopus 로고    scopus 로고
    • A numerical flow model and experimental results of a cryogenic micro-valve for distributed cooling applications
    • Sep./Oct.
    • T. R. Brosten, J. M. Park, A. T. Evans, K. Rasmussen, G. F. Nellis, S. A. Klein, J. R. Feller, L. Salerno, and Y. B. Gianchandani, "A numerical flow model and experimental results of a cryogenic micro-valve for distributed cooling applications," Cryogenics, vol. 47, no. 9/10, pp. 501-509, Sep./Oct. 2007.
    • (2007) Cryogenics , vol.47 , Issue.9-10 , pp. 501-509
    • Brosten, T.R.1    Park, J.M.2    Evans, A.T.3    Rasmussen, K.4    Nellis, G.F.5    Klein, S.A.6    Feller, J.R.7    Salerno, L.8    Gianchandani, Y.B.9
  • 28
    • 0017160392 scopus 로고
    • Body position and cerebrospinal fluid pressure. Part I: Clinical studies on the effect of rapid postural changes
    • Jun.
    • B. Magnes, "Body position and cerebrospinal fluid pressure. Part I: Clinical studies on the effect of rapid postural changes," J. Neurosurg., vol. 44, no. 6, pp. 687-697, Jun. 1976.
    • (1976) J. Neurosurg. , vol.44 , Issue.6 , pp. 687-697
    • Magnes, B.1
  • 30
    • 3042622134 scopus 로고    scopus 로고
    • Bladder stones-Red herring for resurgence of spasticity in a spinal cord injury patient with implantation of Medtronic Synchromed pump for intrathecal delivery of baclofen-A case report
    • S. Vaidyanathan, B.M. Soni, T. Oo, P. L. Hughes, G. Singh, J.W. H.Watt, and P. Sett, "Bladder stones-Red herring for resurgence of spasticity in a spinal cord injury patient with implantation of Medtronic Synchromed pump for intrathecal delivery of baclofen-A case report," BMC Urology, vol. 3, no. 3, 2003.
    • (2003) BMC Urology , vol.3 , Issue.3
    • Vaidyanathan, S.1    Soni, B.M.2    Oo, T.3    Hughes, P.L.4    Singh, G.5    Watt, J.W.H.6    Sett, P.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.