A piezoelectric valve manifold with embedded sensors for multi-drug delivery protocols

Author keywords

Drug delivery; Liquid flow; Manifold; Microvalve; Piezoelectric

Indexed keywords

CLOSED-LOOP CONTROL; DRUG DELIVERY DEVICES; DYNAMIC RANGE; EMBEDDED SENSORS; GLASS SUBSTRATES; INTRATHECAL; ISOPROPYL ALCOHOLS; LABORATORY TEST; LIQUID FLOW; MANIFOLD; MICRO VALVES; PIEZOELECTRIC STACK; PIEZOELECTRIC VALVE; PIEZORESISTIVE PRESSURE SENSORS; VALVE SEATS;

EID: 77952787991     PISSN: 10846999     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MEMSYS.2010.5442384     Document Type: Conference Paper
Times cited : (1)

References (17)
  • 1
    • 0034777540 scopus 로고    scopus 로고
    • Epidural Anaesthesia
    • Article 11
    • L. Visser, "Epidural Anaesthesia," Update in Anesthesia, Issue 13, Article 11, 2001, pp. 1-4
    • (2001) Update in Anesthesia , Issue.13 , pp. 1-4
    • Visser, L.1
  • 3
    • 0032927561 scopus 로고    scopus 로고
    • A prospective study of long-term intrathecal morphine in the management of chronic nonmalignant pain
    • V.C. Anderson, K.J. Burchiel, "A prospective study of long-term intrathecal morphine in the management of chronic nonmalignant pain," Neurosurgery, 44, 2 (1999)
    • (1999) Neurosurgery , vol.44 , pp. 2
    • Anderson, V.C.1    Burchiel, K.J.2
  • 4
    • 77952776029 scopus 로고    scopus 로고
    • American Society of Health System Pharmacists
    • ASHP guidelines on quality assurance for pharmacy-prepared sterile products
    • ASHP guidelines on quality assurance for pharmacy-prepared sterile products. American Society of Health System Pharmacists, Am J Health Syst Pharm, 57, 12 (2000)
    • (2000) Am J Health Syst Pharm , vol.57 , pp. 12
  • 5
    • 0025912462 scopus 로고
    • Spinal anesthesia using subcutaneously implanted pumps for intrathecal drug infusion
    • D.W. Coombs, N. Fine, "Spinal anesthesia using subcutaneously implanted pumps for intrathecal drug infusion," Anesth Analg, 73, 2 (1991)
    • (1991) Anesth Analg , vol.73 , pp. 2
    • Coombs, D.W.1    Fine, N.2
  • 6
    • 0018831974 scopus 로고
    • Site of action of intrathecal morphine
    • J.S. Crawford, "Site of action of intrathecal morphine," Br Med J, 281, 6248 (1980)
    • (1980) Br Med J , vol.281 , pp. 6248
    • Crawford, J.S.1
  • 8
    • 0033832188 scopus 로고    scopus 로고
    • Current practices in intraspinal therapy - A survey of clinical trends and decision making
    • S.J. Hassenbusch, R.K. Portenoy, "Current practices in intraspinal therapy - a survey of clinical trends and decision making," J Pain Symptom Manage, 20, 2 (2000)
    • (2000) J Pain Symptom Manage , vol.20 , pp. 2
    • Hassenbusch, S.J.1    Portenoy, R.K.2
  • 9
    • 49749100800 scopus 로고    scopus 로고
    • New standards to assess and manage pain
    • Joint Committee on Accrediation of Healthcare Organizations
    • Joint Committee on Accrediation of Healthcare Organizations, "New standards to assess and manage pain," Jt Comm Perspect, 19, 5 (1999)
    • (1999) Jt Comm Perspect , vol.19 , pp. 5
  • 10
    • 85052610323 scopus 로고    scopus 로고
    • Management of chronic back and leg pain by intrathecal drug delivery
    • N.G. Rainov, V. Heidecke, "Management of chronic back and leg pain by intrathecal drug delivery," Acta Neurochir Suppl, 97, 1 (2007)
    • (2007) Acta Neurochir Suppl , vol.97 , pp. 1
    • Rainov, N.G.1    Heidecke, V.2
  • 11
    • 0142179214 scopus 로고    scopus 로고
    • Long-term intrathecal opioid therapy with a patient-activated, implanted delivery system for the treatment of refractory cancer pain
    • R.L. Rauck, D. Cherry, M.F. Boyer, P. Kosek, J. Dunn, K. Alo, "Long-term intrathecal opioid therapy with a patient-activated, implanted delivery system for the treatment of refractory cancer pain," J Pain, 4, 8 (2003)
    • (2003) J Pain , vol.4 , pp. 8
    • Rauck, R.L.1    Cherry, D.2    Boyer, M.F.3    Kosek, P.4    Dunn, J.5    Alo, K.6
  • 12
    • 2542422772 scopus 로고    scopus 로고
    • Polyanalgesic Consensus Conference 2003: An update on the management of pain by intraspinal drug delivery - Report of an expert panel
    • S.J. Hassenbusch, et al., "Polyanalgesic Consensus Conference 2003: an update on the management of pain by intraspinal drug delivery - report of an expert panel," J Pain Symptom Manage, 27, 6 (2004)
    • (2004) J Pain Symptom Manage , vol.27 , pp. 6
    • Hassenbusch, S.J.1
  • 13
    • 50049116629 scopus 로고    scopus 로고
    • A Low Power, Microvalve-Regulated Drug Delivery System using a Si Micro-Spring Pressurized Balloon Reservoir
    • Lyon, France
    • A.T. Evans, J. M. Park, et al., "A Low Power, Microvalve-Regulated Drug Delivery System using a Si Micro-Spring Pressurized Balloon Reservoir." Transducers '07, Lyon, France.
    • Transducers '07
    • Evans, A.T.1    Park, J.M.2
  • 16
    • 0347134477 scopus 로고    scopus 로고
    • Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies
    • DOI 10.1002/elps.200305584
    • S.K. Sia, G.M. Whitesides, "Microfluidic Devices Fabricated in Poly(dimethylsiloxane) for biological studies," Electrophoresis, vol. 24, 2003, 3563-3576 (Pubitemid 38089159)
    • (2003) Electrophoresis , vol.24 , Issue.21 , pp. 3563-3576
    • Sia, S.K.1    Whitesides, G.M.2
  • 17
    • 0024764864 scopus 로고
    • Normally Closed Microvalve and Micropump Fabricated on a Silicon Wafer
    • M. Esashi, S. Shoji, A. Nakano, "Normally Closed Microvalve and Micropump Fabricated on a Silicon Wafer," Sensors and Actuators, 20, 1-2 (1989)
    • (1989) Sensors and Actuators , vol.20 , pp. 1-2
    • Esashi, M.1    Shoji, S.2    Nakano, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.