메뉴 건너뛰기




Volumn 88, Issue 1, 2011, Pages

A history of intraocular pressure and its measurement

Author keywords

history of tonometry; Intraocular pressure; intraocular pressure measurement; tonometers; tonometry

Indexed keywords

19TH CENTURY; 20TH CENTURY; BIOMECHANICAL PROPERTIES; DYNAMIC CONTOUR; EASTERN EUROPE; INTRA OCULAR PRESSURE; OPTIC NEUROPATHIES; POTENTIAL ERRORS; TONOMETERS; TONOMETRY; VISION LOSS;

EID: 78651472330     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/OPX.0b013e318205a4e7     Document Type: Review
Times cited : (84)

References (81)
  • 1
    • 0000224192 scopus 로고
    • Diseases of the lens and vitreous; Glaucoma and hypotony
    • Duke-Elder S, ed. St. Louis, MO: Mosby
    • Duke-Elder S, Jay B. Diseases of the lens and vitreous; glaucoma and hypotony. In: Duke-Elder S, ed. System of Ophthalmology, vol. 11. St. Louis, MO: Mosby; 1969.
    • (1969) System of Ophthalmology , vol.11
    • Duke-Elder, S.1    Jay, B.2
  • 2
    • 78651494162 scopus 로고
    • Bowman W. BMJ 1852;377-82.
    • (1852) BMJ , pp. 377-382
    • Bowman, W.1
  • 3
    • 78651480403 scopus 로고    scopus 로고
    • The Measurement of Intraocular Pressure: The Museum of the Royal Australian and New Zealand College of Ophthalmologists and the Royal Victoria Ear and Ear Hospital, Melbourne, Australia
    • The Measurement of Intraocular Pressure: The Museum of the Royal Australian and New Zealand College of Ophthalmologists and the Royal Victoria Ear and Ear Hospital, Melbourne, Australia.
  • 4
    • 0000893547 scopus 로고
    • Theories ophthalmotonometres
    • Imbert A. Theories ophthalmotonometres. Arch Ophthalmol 1885; 5:358-63.
    • (1885) Arch Ophthalmol , vol.5 , pp. 358-363
    • Imbert, A.1
  • 6
    • 0038312943 scopus 로고    scopus 로고
    • Reproducibility and agreement between three methods of intraocular pressure measurement
    • Atanassov MA, Konareva MI. Reproducibility and agreement between three methods of intraocular pressure measurement. Folia Med (Plovdiv) 2002;44:19-22.
    • (2002) Folia Med (Plovdiv) , vol.44 , pp. 19-22
    • Atanassov, M.A.1    Konareva, M.I.2
  • 7
    • 77049220240 scopus 로고
    • Un nouveau tonometre d'applanation
    • Goldmann H. Un nouveau tonometre d'applanation. Bull Soc Ophtalmol Fr 1955;67:474-8.
    • (1955) Bull Soc Ophtalmol Fr , vol.67 , pp. 474-478
    • Goldmann, H.1
  • 9
    • 0027269723 scopus 로고
    • The effect of corneal thickness on applanation tonometry
    • Whitacre MM, Stein RA, Hassanein K. The effect of corneal thickness on applanation tonometry. Am J Ophthalmol 1993;115:592-6.
    • (1993) Am J Ophthalmol , vol.115 , pp. 592-596
    • Whitacre, M.M.1    Stein, R.A.2    Hassanein, K.3
  • 11
    • 0030963090 scopus 로고    scopus 로고
    • Distribution of central corneal thickness and its association with intraocular pressure: The rotterdam study
    • Wolfs RC, Klaver CC, Vingerling JR, Grobbee DE, Hofman A, de Jong PT. Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study. Am J Ophthalmol 1997;123:767-72.
    • (1997) Am J Ophthalmol , vol.123 , pp. 767-772
    • Wolfs, R.C.1    Klaver, C.C.2    Vingerling, J.R.3    Grobbee, D.E.4    Hofman, A.5    De Jong, P.T.6
  • 12
    • 0034803965 scopus 로고    scopus 로고
    • Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS)
    • Brandt JD, Beiser JA, Kass MA, Gordon MO. Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS). Ophthalmology 2001;108:1779-88.
    • (2001) Ophthalmology , vol.108 , pp. 1779-1788
    • Brandt, J.D.1    Beiser, J.A.2    Kass, M.A.3    Gordon, M.O.4
  • 14
    • 0016422386 scopus 로고
    • The non-contact ("air puff) tonometer: Variability and corneal staining
    • Myers KJ, Scott CA. The non-contact ("air puff) tonometer: variability and corneal staining. Am J Optom Physiol Opt 1975;52:36-46.
    • (1975) Am J Optom Physiol Opt , vol.52 , pp. 36-46
    • Myers, K.J.1    Scott, C.A.2
  • 15
    • 0017598952 scopus 로고
    • A clinical evaluation of the non-contact tonometer
    • Wittenberg S. A clinical evaluation of the non-contact tonometer. J Am Optom Assoc 1977;48:196-207.
    • (1977) J Am Optom Assoc , vol.48 , pp. 196-207
    • Wittenberg, S.1
  • 16
    • 0024792325 scopus 로고
    • Comparison of a new noncontact tonometer with Goldmann applanation
    • Moseley MJ, Evans NM, Fielder AR. Comparison of a new noncontact tonometer with Goldmann applanation. Eye (Lond) 1989;3(Pt. 3):332-7.
    • (1989) Eye (Lond) , vol.3 , Issue.PART 3 , pp. 332-337
    • Moseley, M.J.1    Evans, N.M.2    Fielder, A.R.3
  • 18
    • 21344460937 scopus 로고    scopus 로고
    • The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry
    • Tonnu PA, Ho T, Newson T, El Sheikh A, Sharma K, White E, Bunce C, Garway-Heath D. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol 2005;89:851-4.
    • (2005) Br J Ophthalmol , vol.89 , pp. 851-854
    • Tonnu, P.A.1    Ho, T.2    Newson, T.3    El Sheikh, A.4    Sharma, K.5    White, E.6    Bunce, C.7    Garway-Heath, D.8
  • 21
    • 49049107379 scopus 로고    scopus 로고
    • Corneal hysteresis but not corneal thickness correlates with optic nerve surface compliance in glaucoma patients
    • Wells AP, Garway-Heath DF, Poostchi A, Wong T, Chan KC, Sachdev N. Corneal hysteresis but not corneal thickness correlates with optic nerve surface compliance in glaucoma patients. Invest Ophthalmol Vis Sci 2008;49:3262-8.
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 3262-3268
    • Wells, A.P.1    Garway-Heath, D.F.2    Poostchi, A.3    Wong, T.4    Chan, K.C.5    Sachdev, N.6
  • 22
    • 41949128428 scopus 로고    scopus 로고
    • Reproducibility and clinical relevance of the ocular response analyzer in nonoperated eyes: Corneal biomechanical and tonometric implications
    • Moreno-Montanes J, Maldonado MJ, Garcia N, Mendiluce L, Garcia-Gomez PJ, Segui-Gomez M. Reproducibility and clinical relevance of the ocular response analyzer in nonoperated eyes: corneal biomechanical and tonometric implications. Invest Ophthalmol Vis Sci 2008;49:968-74.
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 968-974
    • Moreno-Montanes, J.1    Maldonado, M.J.2    Garcia, N.3    Mendiluce, L.4    Garcia-Gomez, P.J.5    Segui-Gomez, M.6
  • 23
    • 0014274198 scopus 로고
    • A rapid pneumatic applanation tonometer. Comparative findings and evaluation
    • Langham ME, McCarthy E. A rapid pneumatic applanation tonometer. Comparative findings and evaluation. Arch Ophthalmol 1968;79:389-99.
    • (1968) Arch Ophthalmol , vol.79 , pp. 389-399
    • Langham, M.E.1    McCarthy, E.2
  • 24
    • 0018411106 scopus 로고
    • The pneumatonograph. A laboratory study
    • Moses RA, Grodzki WJ Jr. The pneumatonograph. A laboratory study. Arch Ophthalmol 1979;97:547-52.
    • (1979) Arch Ophthalmol , vol.97 , pp. 547-552
    • Moses, R.A.1    Grodzki Jr., W.J.2
  • 27
    • 0015402313 scopus 로고
    • Measurement of intraocular pressure with a pneumatic applanation tonometer
    • West CE, Capella JA, Kaufman HE. Measurement of intraocular pressure with a pneumatic applanation tonometer. Am J Ophthalmol 1972;74:505-9.
    • (1972) Am J Ophthalmol , vol.74 , pp. 505-509
    • West, C.E.1    Capella, J.A.2    Kaufman, H.E.3
  • 28
    • 0031703801 scopus 로고    scopus 로고
    • Tonometry in adults and children. A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo
    • Eisenberg DL, Sherman BG, McKeown CA, Schuman JS. Tonometry in adults and children. A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo. Ophthalmology 1998;105:1173-81.
    • (1998) Ophthalmology , vol.105 , pp. 1173-1181
    • Eisenberg, D.L.1    Sherman, B.G.2    McKeown, C.A.3    Schuman, J.S.4
  • 29
    • 4444321895 scopus 로고    scopus 로고
    • Dynamic contour tonometry: A comparative study on human cadaver eyes
    • Kniestedt C, Nee M, Stamper RL. Dynamic contour tonometry: a comparative study on human cadaver eyes. Arch Ophthalmol 2004; 122:1287-93.
    • (2004) Arch Ophthalmol , vol.122 , pp. 1287-1293
    • Kniestedt, C.1    Nee, M.2    Stamper, R.L.3
  • 30
    • 33747346135 scopus 로고    scopus 로고
    • Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow pneumatonometer
    • Saleh TA, Adams M, McDermott B, Claridge KG, Ewings P. Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow pneumatonometer. Clin Experiment Ophthalmol 2006;34:516-20.
    • (2006) Clin Experiment Ophthalmol , vol.34 , pp. 516-520
    • Saleh, T.A.1    Adams, M.2    McDermott, B.3    Claridge, K.G.4    Ewings, P.5
  • 32
    • 78651485394 scopus 로고
    • Clinical significance of ocular rigidity in relation to the tonometric measurement
    • Friedenwald JS. Clinical significance of ocular rigidity in relation to the tonometric measurement. Trans Am Acad Ophthalmol Otolaryngol 1949;53:262-4.
    • (1949) Trans Am Acad Ophthalmol Otolaryngol , vol.53 , pp. 262-264
    • Friedenwald, J.S.1
  • 33
    • 0017566928 scopus 로고
    • Non-contact and Mackay-Marg tonometry: Comparison in patients ages 7 to 85 years
    • Augsburger A, Terry JE. Non-contact and Mackay-Marg tonometry: comparison in patients ages 7 to 85 years. Am J Optom Physiol Opt 1977;54:31-4.
    • (1977) Am J Optom Physiol Opt , vol.54 , pp. 31-34
    • Augsburger, A.1    Terry, J.E.2
  • 34
    • 0015840690 scopus 로고
    • The Mackay-Marg-tonometer. VI. Corneal rigidity and intraocular pressure (author's transl)]
    • Stepanik J. [The Mackay-Marg-tonometer. VI. Corneal rigidity and intraocular pressure (author's transl)]. Albrecht Von Graefes Arch Klin Exp Ophthalmol 1973;188:211-6.
    • (1973) Albrecht von Graefes Arch Klin Exp Ophthalmol , vol.188 , pp. 211-216
    • Stepanik, J.1
  • 35
    • 0014800378 scopus 로고
    • Validity of Mackay-Marg electronic applanation tonometer in patients with scarred irregular corneas
    • Kaufman HE, Wind CA, Waltman SR. Validity of Mackay-Marg electronic applanation tonometer in patients with scarred irregular corneas. Am J Ophthalmol 1970;69:1003-7.
    • (1970) Am J Ophthalmol , vol.69 , pp. 1003-1007
    • Kaufman, H.E.1    Wind, C.A.2    Waltman, S.R.3
  • 36
    • 0016788858 scopus 로고
    • Comparison of MacKay-Marg, Goldmann, and Perkins tonometers in abnormal corneas
    • McMillan F, Forster RK. Comparison of MacKay-Marg, Goldmann, and Perkins tonometers in abnormal corneas. Arch Ophthalmol 1975;93:420-4.
    • (1975) Arch Ophthalmol , vol.93 , pp. 420-424
    • McMillan, F.1    Forster, R.K.2
  • 37
    • 0023893222 scopus 로고
    • Comparison of the Tono-Pen to the Goldmann applanation tonometer
    • Frenkel RE, Hong YJ, Shin DH. Comparison of the Tono-Pen to the Goldmann applanation tonometer. Arch Ophthalmol 1988;106:750-3.
    • (1988) Arch Ophthalmol , vol.106 , pp. 750-753
    • Frenkel, R.E.1    Hong, Y.J.2    Shin, D.H.3
  • 38
    • 0023470773 scopus 로고
    • Clinical comparison of the Oculab Tono-Pen to the Goldmann applanation tonometer
    • Kao SF, Lichter PR, Bergstrom TJ, Rowe S, Musch DC. Clinical comparison of the Oculab Tono-Pen to the Goldmann applanation tonometer. Ophthalmology 1987;94:1541-4.
    • (1987) Ophthalmology , vol.94 , pp. 1541-1544
    • Kao, S.F.1    Lichter, P.R.2    Bergstrom, T.J.3    Rowe, S.4    Musch, D.C.5
  • 39
    • 0023781691 scopus 로고
    • Tono-pen a new position-independent tonometer. Comparison with the Goldmann tonometer by applanation measurement
    • Hessemer V, Rossler R, Jacobi KW. [Tono-pen, a new position-independent tonometer. Comparison with the Goldmann tonometer by applanation measurement]. Klin Monbl Augenheilkd 1988;193:420-6.
    • (1988) Klin Monbl Augenheilkd , vol.193 , pp. 420-426
    • Hessemer, V.1    Rossler, R.2    Jacobi, K.W.3
  • 40
    • 0026718991 scopus 로고
    • Accuracy of intraocular pressure measurements with two different tonometers through bandage contact lenses
    • Mark LK, Asbell PA, Torres MA, Failla SJ. Accuracy of intraocular pressure measurements with two different tonometers through bandage contact lenses. Cornea 1992;11:277-81.
    • (1992) Cornea , vol.11 , pp. 277-281
    • Mark, L.K.1    Asbell, P.A.2    Torres, M.A.3    Failla, S.J.4
  • 41
  • 42
    • 0036946949 scopus 로고    scopus 로고
    • Noninvasive determination of intraocular pressure in the rat eye. Comparison of an electronic tonometer (TonoPen), and a rebound (impact probe) tonometer
    • Goldblum D, Kontiola AI, Mittag T, Chen B, Danias J. Noninvasive determination of intraocular pressure in the rat eye. Comparison of an electronic tonometer (TonoPen), and a rebound (impact probe) tonometer. Graefes Arch Clin Exp Ophthalmol 2002;240:942-6.
    • (2002) Graefes Arch Clin Exp Ophthalmol , vol.240 , pp. 942-946
    • Goldblum, D.1    Kontiola, A.I.2    Mittag, T.3    Chen, B.4    Danias, J.5
  • 44
    • 0030318702 scopus 로고    scopus 로고
    • A new electromechanical method for measuring intraocular pressure
    • Kontiola A. A new electromechanical method for measuring intraocular pressure. Doc Ophthalmol 1996;93:265-76.
    • (1996) Doc Ophthalmol , vol.93 , pp. 265-276
    • Kontiola, A.1
  • 47
    • 1142299596 scopus 로고    scopus 로고
    • Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic
    • Kontiola A, Puska P. Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic. Graefes Arch Clin Exp Ophthalmol 2004;242:3-7.
    • (2004) Graefes Arch Clin Exp Ophthalmol , vol.242 , pp. 3-7
    • Kontiola, A.1    Puska, P.2
  • 48
    • 28244471011 scopus 로고    scopus 로고
    • Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry*
    • van der Jagt LH, Jansonius NM. Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry*. Ophthalmic Physiol Opt 2005;25:429-35.
    • (2005) Ophthalmic Physiol Opt , vol.25 , pp. 429-435
    • Van Der Jagt, L.H.1    Jansonius, N.M.2
  • 50
    • 33745282996 scopus 로고    scopus 로고
    • Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients
    • Brusini P, Salvetat ML, Zeppieri M, Tosoni C, Parisi L. Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients. J Glaucoma 2006;15:213-7.
    • (2006) J Glaucoma , vol.15 , pp. 213-217
    • Brusini, P.1    Salvetat, M.L.2    Zeppieri, M.3    Tosoni, C.4    Parisi, L.5
  • 51
    • 33644629030 scopus 로고    scopus 로고
    • Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes
    • Garcia-Resua C, Gonzalez-Meijome JM, Gilino J, Yebra-Pimentel E. Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes. Optom Vis Sci 2006;83:102-7.
    • (2006) Optom Vis Sci , vol.83 , pp. 102-107
    • Garcia-Resua, C.1    Gonzalez-Meijome, J.M.2    Gilino, J.3    Yebra-Pimentel, E.4
  • 52
    • 33746277068 scopus 로고    scopus 로고
    • Agreement of rebound tonometer in measuring intraocular pressure with three types of applanation tonometers
    • Nakamura M, Darhad U, Tatsumi Y, Fujioka M, Kusuhara A, Maeda H, Negi A. Agreement of rebound tonometer in measuring intraocular pressure with three types of applanation tonometers. Am J Ophthalmol 2006;142:332-4.
    • (2006) Am J Ophthalmol , vol.142 , pp. 332-334
    • Nakamura, M.1    Darhad, U.2    Tatsumi, Y.3    Fujioka, M.4    Kusuhara, A.5    Maeda, H.6    Negi, A.7
  • 53
    • 25644460363 scopus 로고    scopus 로고
    • Dynamic contour tonometry: Presentation of a new tonometer
    • Kanngiesser HE, Kniestedt C, Robert YC. Dynamic contour tonometry: presentation of a new tonometer. J Glaucoma 2005;14:344-50.
    • (2005) J Glaucoma , vol.14 , pp. 344-350
    • Kanngiesser, H.E.1    Kniestedt, C.2    Robert, Y.C.3
  • 55
    • 22544486553 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry with goldman applanation tonometry over a wide range of central corneal thickness
    • Doyle A, Lachkar Y. Comparison of dynamic contour tonometry with goldman applanation tonometry over a wide range of central corneal thickness. J Glaucoma 2005;14:288-92.
    • (2005) J Glaucoma , vol.14 , pp. 288-292
    • Doyle, A.1    Lachkar, Y.2
  • 56
    • 23744463890 scopus 로고    scopus 로고
    • Dynamic contour tonometry for intraocular pressure measurement
    • Kamppeter BA, Jonas JB. Dynamic contour tonometry for intraocular pressure measurement. Am J Ophthalmol 2005;140:318-20.
    • (2005) Am J Ophthalmol , vol.140 , pp. 318-320
    • Kamppeter, B.A.1    Jonas, J.B.2
  • 57
    • 27744519845 scopus 로고    scopus 로고
    • Clinical comparison of contour and applanation tonometry and their relationship to pachymetry
    • Kniestedt C, Lin S, Choe J, Bostrom A, Nee M, Stamper RL. Clinical comparison of contour and applanation tonometry and their relationship to pachymetry. Arch Ophthalmol 2005;123:1532-7.
    • (2005) Arch Ophthalmol , vol.123 , pp. 1532-1537
    • Kniestedt, C.1    Lin, S.2    Choe, J.3    Bostrom, A.4    Nee, M.5    Stamper, R.L.6
  • 58
    • 33645823534 scopus 로고    scopus 로고
    • Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry
    • Ku JY, Danesh-Meyer HV, Craig JP, Gamble GD, McGhee CN. Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry. Eye (Lond) 2006;20:191-8.
    • (2006) Eye (Lond) , vol.20 , pp. 191-198
    • Ku, J.Y.1    Danesh-Meyer, H.V.2    Craig, J.P.3    Gamble, G.D.4    McGhee, C.N.5
  • 59
    • 30344436327 scopus 로고    scopus 로고
    • Intraocular pressure measurement-comparison of dynamic contour tonometry and goldmann applanation tonometry
    • Schneider E, Grehn F. Intraocular pressure measurement-comparison of dynamic contour tonometry and goldmann applanation tonometry. J Glaucoma 2006;15:2-6.
    • (2006) J Glaucoma , vol.15 , pp. 2-6
    • Schneider, E.1    Grehn, F.2
  • 60
    • 3042667876 scopus 로고    scopus 로고
    • Dynamic contour tonometry for post-LASIK intraocular pressure measurements
    • Duba I, Wirthlin AC. Dynamic contour tonometry for post-LASIK intraocular pressure measurements. Klin Monbl Augenheilkd 2004; 221:347-50.
    • (2004) Klin Monbl Augenheilkd , vol.221 , pp. 347-350
    • Duba, I.1    Wirthlin, A.C.2
  • 61
    • 0041360373 scopus 로고    scopus 로고
    • Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis
    • Kaufmann C, Bachmann LM, Thiel MA. Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis. Invest Ophthalmol Vis Sci 2003;44:3790-4.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 3790-3794
    • Kaufmann, C.1    Bachmann, L.M.2    Thiel, M.A.3
  • 62
    • 13844318981 scopus 로고    scopus 로고
    • Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK
    • Siganos DS, Papastergiou GI, Moedas C. Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK. J Cataract Refract Surg 2004;30:746-51.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 746-751
    • Siganos, D.S.1    Papastergiou, G.I.2    Moedas, C.3
  • 63
    • 0019795784 scopus 로고
    • The ocular pulse
    • Perkins ES. The ocular pulse. Curr Eye Res 1981;1:19-23.
    • (1981) Curr Eye Res , vol.1 , pp. 19-23
    • Perkins, E.S.1
  • 64
    • 0021141676 scopus 로고
    • Ocular pulse curve in glaucoma without hypertension
    • Perkins ES, Phelps CD. [Ocular pulse curve in glaucoma without hypertension]. Klin Monbl Augenheilkd 1984;184:303-4.
    • (1984) Klin Monbl Augenheilkd , vol.184 , pp. 303-304
    • Perkins, E.S.1    Phelps, C.D.2
  • 65
    • 1842370258 scopus 로고    scopus 로고
    • Reduced ocular pulse amplitude in low tension glaucoma is independent of vasospasm
    • Schmidt KG, Ruckmann AV, Mittag TW, Hessemer V, Pillunat LE. Reduced ocular pulse amplitude in low tension glaucoma is independent of vasospasm. Eye (Lond) 1997;11(Pt. 4):485-8.
    • (1997) Eye (Lond) , vol.11 , Issue.PART 4 , pp. 485-488
    • Schmidt, K.G.1    Ruckmann, A.V.2    Mittag, T.W.3    Hessemer, V.4    Pillunat, L.E.5
  • 66
    • 0036724807 scopus 로고    scopus 로고
    • Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertension
    • Schwenn O, Troost R, Vogel A, Grus F, Beck S, Pfeiffer N. Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertension. Br J Ophthalmol 2002;86: 981-4.
    • (2002) Br J Ophthalmol , vol.86 , pp. 981-984
    • Schwenn, O.1    Troost, R.2    Vogel, A.3    Grus, F.4    Beck, S.5    Pfeiffer, N.6
  • 68
    • 0036692047 scopus 로고    scopus 로고
    • Assessment of intraocular pressure in children by digital tension
    • Ficarra AP, Sorkin R, Morrison C. Assessment of intraocular pressure in children by digital tension. Optometry 2002;73:499-506.
    • (2002) Optometry , vol.73 , pp. 499-506
    • Ficarra, A.P.1    Sorkin, R.2    Morrison, C.3
  • 69
  • 71
    • 28244436695 scopus 로고    scopus 로고
    • Evaluation of the pressure phosphene tonometer as a self-tonometer
    • Naruse S, Mori K, Kinoshita S. Evaluation of the pressure phosphene tonometer as a self-tonometer. Ophthalmic Physiol Opt 2005;25: 421-8.
    • (2005) Ophthalmic Physiol Opt , vol.25 , pp. 421-428
    • Naruse, S.1    Mori, K.2    Kinoshita, S.3
  • 72
    • 28244464854 scopus 로고    scopus 로고
    • The Proview Eye Pressure Monitor: Influence of clinical factors on accuracy and agreement with the Goldmann tonometer
    • Herse P, Hans A, Hall J, Langejans J, Markoulli M. The Proview Eye Pressure Monitor: influence of clinical factors on accuracy and agreement with the Goldmann tonometer. Ophthalmic Physiol Opt 2005; 25:416-20.
    • (2005) Ophthalmic Physiol Opt , vol.25 , pp. 416-420
    • Herse, P.1    Hans, A.2    Hall, J.3    Langejans, J.4    Markoulli, M.5
  • 74
    • 3543128942 scopus 로고    scopus 로고
    • Clinical comparison of the Proview eye pressure monitor with the Goldmann applanation tonometer and the Tonopen
    • Li J, Herndon LW, Asrani SG, Stinnett S, Allingham RR. Clinical comparison of the Proview eye pressure monitor with the Goldmann applanation tonometer and the Tonopen. Arch Ophthalmol 2004; 122:1117-21.
    • (2004) Arch Ophthalmol , vol.122 , pp. 1117-1121
    • Li, J.1    Herndon, L.W.2    Asrani, S.G.3    Stinnett, S.4    Allingham, R.R.5
  • 75
  • 76
    • 6344221844 scopus 로고    scopus 로고
    • Prospective comparison of the new indentation tonometer TGdC-01 the noncontact tonometer PT100 and the conventional Goldmann applanation tonometer
    • Muller A, Godenschweger L, Lang GE, Kampmeier J. [Prospective comparison of the new indentation tonometer TGdC-01, the noncontact tonometer PT100 and the conventional Goldmann applanation tonometer]. Klin Monbl Augenheilkd 2004;221:762-8.
    • (2004) Klin Monbl Augenheilkd , vol.221 , pp. 762-768
    • Muller, A.1    Godenschweger, L.2    Lang, G.E.3    Kampmeier, J.4
  • 77
    • 15244345387 scopus 로고    scopus 로고
    • Evaluation of portable TGDc-01 tonometers and comparison with the Goldmann applanation tonometer
    • Rombold F, Thiel MJ, Neubauer AS, Hirneiss C, Kampik A. [Evaluation of portable TGDc-01 tonometers and comparison with the Goldmann applanation tonometer]. Ophthalmologe 2005;102:158-62.
    • (2005) Ophthalmologe , vol.102 , pp. 158-162
    • Rombold, F.1    Thiel, M.J.2    Neubauer, A.S.3    Hirneiss, C.4    Kampik, A.5
  • 78
    • 20444472031 scopus 로고    scopus 로고
    • Transpalpebral measurement of intraocular pressure using the TGDc-01 tonometer versus standard Goldmann applanation tonometry
    • Losch A, Scheuerle A, Rupp V, Auffarth G, Becker M. Transpalpebral measurement of intraocular pressure using the TGDc-01 tonometer versus standard Goldmann applanation tonometry. Graefes Arch Clin Exp Ophthalmol 2005;243:313-6.
    • (2005) Graefes Arch Clin Exp Ophthalmol , vol.243 , pp. 313-316
    • Losch, A.1    Scheuerle, A.2    Rupp, V.3    Auffarth, G.4    Becker, M.5
  • 79
    • 21244458331 scopus 로고    scopus 로고
    • The validity of a digital eyelid tonometer (TGDc-01) and its comparison with Goldmann applanation tonometry - A pilot study
    • Lam AK, Lam CH, Chan R. The validity of a digital eyelid tonometer (TGDc-01) and its comparison with Goldmann applanation tonometry - a pilot study. Ophthalmic Physiol Opt 2005;25:205-10.
    • (2005) Ophthalmic Physiol Opt , vol.25 , pp. 205-210
    • Lam, A.K.1    Lam, C.H.2    Chan, R.3
  • 80
    • 0013956016 scopus 로고
    • Intra-ocular pressure, glaucoma, and glaucoma suspects in a defined population
    • Hollows FC, Graham PA. Intra-ocular pressure, glaucoma, and glaucoma suspects in a defined population. Br J Ophthalmol 1966;50:570-86.
    • (1966) Br J Ophthalmol , vol.50 , pp. 570-586
    • Hollows, F.C.1    Graham, P.A.2
  • 81
    • 0008313812 scopus 로고
    • On the distribution of applanation pressure and Arcuate Scotoma
    • Patterson G, Miller SJ, Patterson GD, eds. Boston, MA: Little, Brown
    • Armaly MF. On the distribution of applanation pressure and arcuate scotoma. In: Patterson G, Miller SJ, Patterson GD, eds. Drug Mechanisms in Glaucoma. Boston, MA: Little, Brown; 1966.
    • (1966) Drug Mechanisms in Glaucoma
    • Armaly, M.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.