Volumn 103, Issue 8, 2006, Pages 713-723

Dynamic contour tonometry;Dynamische konturtonometrie

Author keywords

Contour match; Contour tonometry; Corneal rigidity; Intraocular pressure; Ocular pulse amplitude

Indexed keywords

BIOMECHANICS; CHOROID; CORNEA; DIASTOLE; DYNAMIC CONTOUR TONOMETRY; GLAUCOMA; INTRAOCULAR PRESSURE; OCULAR PULSE AMPLITUDE; PULSE WAVE; REVIEW; SYSTOLE; TONOMETRY;

EID: 33747040157     PISSN: 0941293X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00347-006-1387-7     Document Type: Review
Times cited : (23)

References (29)
  • 1
    • 0034803965 scopus 로고    scopus 로고
    • Central corneal thickness in the ocular hypertension treatment study (OHTS)
    • Brandt JD, Beisser JA, Kass MA et al. (2001) Central corneal thickness in the ocular hypertension treatment study (OHTS). Ophthalmology 108: 1779-1788
    • (2001) Ophthalmology , vol.108 , pp. 1779-1788
    • Brandt, J.D.1    Beisser, J.A.2    Kass, M.A.3
  • 2
    • 33646120836 scopus 로고    scopus 로고
    • Dynamic contour tonometry (DCT) versus non-contact tonometry (NCT): A comparative study
    • Burvenich H, Burvenich E, Vincent C (2005) Dynamic contour tonometry (DCT) versus non-contact tonometry (NCT): a comparative study. Bull Soc Belge Ophtalmol 298: 63-69
    • (2005) Bull Soc Belge Ophtalmol , vol.298 , pp. 63-69
    • Burvenich, H.1    Burvenich, E.2    Vincent, C.3
  • 3
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • Doughty MJ, Zaman ML (2000) Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 44: 367-408
    • (2000) Surv Ophthalmol , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 4
    • 22544486553 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry with goldman applanation tonometry over a wide range of central corneal thickness
    • Doyle A, Lachkar Y (2005) Comparison of dynamic contour tonometry with goldman applanation tonometry over a wide range of central corneal thickness. J Glaucoma 14: 288-292
    • (2005) J Glaucoma , vol.14 , pp. 288-292
    • Doyle, A.1    Lachkar, Y.2
  • 5
    • 70449195078 scopus 로고
    • Ueber Applanationstonometrie
    • Goldmann H, Schmidt T (1957) Ueber Applanationstonometrie. Ophthalmologica 134: 221-242
    • (1957) Ophthalmologica , vol.134 , pp. 221-242
    • Goldmann, H.1    Schmidt, T.2
  • 6
    • 33645817489 scopus 로고    scopus 로고
    • Goldmann applanation tonometry and dynamic contour tonometry: Comparison of intraocular pressure measurements in the course of product certification according to en ISO 8612: 2001
    • Hoffmann EM, Pfeiffer N, Barleon L et al. (2006) Goldmann applanation tonometry and dynamic contour tonometry: comparison of intraocular pressure measurements in the course of product certification according to EN ISO 8612: 2001. Ophthalmologe 103: 317-320
    • (2006) Ophthalmologe , vol.103 , pp. 317-320
    • Hoffmann, E.M.1    Pfeiffer, N.2    Barleon, L.3
  • 7
    • 23744463890 scopus 로고    scopus 로고
    • Dynamic contour tonometry for intraocular pressure measurement
    • Kamppeter BA, Jonas JB (2005) Dynamic contour tonometry for intraocular pressure measurement. Am J Ophthalmol 140: 318-320
    • (2005) Am J Ophthalmol , vol.140 , pp. 318-320
    • Kamppeter, B.A.1    Jonas, J.B.2
  • 8
    • 25644460363 scopus 로고    scopus 로고
    • Dynamic contour tonometry: Presentation of a new tonometer
    • Kanngiesser H, Kniestedt C, Robert YC (2005) Dynamic contour tonometry: presentation of a new tonometer. J Glaucoma 14: 344-350
    • (2005) J Glaucoma , vol.14 , pp. 344-350
    • Kanngiesser, H.1    Kniestedt, C.2    Robert, Y.C.3
  • 9
    • 0041360373 scopus 로고    scopus 로고
    • Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis
    • Kaufmann C, Bachmann LM, Thiel MA (2003) Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis. Invest Ophthal mol Vis Sci 44: 3790-3794
    • (2003) Invest Ophthal Mol Vis Sci , vol.44 , pp. 3790-3794
    • Kaufmann, C.1    Bachmann, L.M.2    Thiel, M.A.3
  • 10
    • 27544475024 scopus 로고    scopus 로고
    • Evaluation of the Orssengo-Pye IOP corrective algorithm in LASIK patients with thick corneas
    • Kirstein EM, Husler A (2005) Evaluation of the Orssengo-Pye IOP corrective algorithm in LASIK patients with thick corneas. Optometry 76: 536-543
    • (2005) Optometry , vol.76 , pp. 536-543
    • Kirstein, E.M.1    Husler, A.2
  • 11
    • 4444321895 scopus 로고    scopus 로고
    • Dynamic contour tonometry: A comparative study on human cadaver eyes
    • Kniestedt C, Nee M, Stamper RL (2004) Dynamic contour tonometry: a comparative study on human cadaver eyes. Arch Ophthalmol 122: 1287-1293
    • (2004) Arch Ophthalmol , vol.122 , pp. 1287-1293
    • Kniestedt, C.1    Nee, M.2    Stamper, R.L.3
  • 12
    • 27744519845 scopus 로고    scopus 로고
    • Clinical comparison of contour and applanation tonometry and their relation to pachymetry
    • Kniestedt C, Lin S, Choe J et al. (2005) Clinical comparison of contour and applanation tonometry and their relation to pachymetry. Arch Ophthalmol 123: 1532-1537
    • (2005) Arch Ophthalmol , vol.123 , pp. 1532-1537
    • Kniestedt, C.1    Lin, S.2    Choe, J.3
  • 13
    • 20444489648 scopus 로고    scopus 로고
    • Accuracy of dynamic contour to nometry compared with applanation tonometry in human cadaver eyes of different hydration states
    • Kniestedt C, Nee M, Stamper RL (2005) Accuracy of dynamic contour to nometry compared with applanation tonometry in human cadaver eyes of different hydration states. Graefes Arch Clin Exp Ophthalmol 243: 359-366
    • (2005) Graefes Arch Clin Exp Ophthalmol , vol.243 , pp. 359-366
    • Kniestedt, C.1    Nee, M.2    Stamper, R.L.3
  • 14
    • 33646761304 scopus 로고    scopus 로고
    • Correlation between intraocular pressure, central corneal thickness, stage of glaucoma and demographic patient data: Prospective analysis of biophysical parameters intertiary glaucoma practice populations
    • Kniestedt C, Lin S, Choe J et al. (2006) Correlation between intraocular pressure, central corneal thickness, stage of glaucoma and demographic patient data: prospective analysis of biophysical parameters intertiary glaucoma practice populations. J Glaucoma 15: 91-97
    • (2006) J Glaucoma , vol.15 , pp. 91-97
    • Kniestedt, C.1    Lin, S.2    Choe, J.3
  • 15
    • 28444475214 scopus 로고    scopus 로고
    • The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry
    • Kotecha A, White ET, Shewry JM et al. (2005) The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry. Br J Ophthalmol 89: 1572-1575
    • (2005) Br J Ophthalmol , vol.89 , pp. 1572-1575
    • Kotecha, A.1    White, E.T.2    Shewry, J.M.3
  • 16
    • 33645823534 scopus 로고    scopus 로고
    • Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry
    • Ku JY, Danesh-Meyer HV, Craig JP et al. (2006) Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry. Eye 20: 191-198
    • (2006) Eye , vol.20 , pp. 191-198
    • Ku, J.Y.1    Danesh-Meyer, H.V.2    Craig, J.P.3
  • 17
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    • Luce DA (2005) Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg, 31: 156-162
    • (2005) J Cataract Refract Surg , vol.31 , pp. 156-162
    • Luce, D.A.1
  • 18
    • 0035036158 scopus 로고    scopus 로고
    • Pulsatile ocular blood flow study: Decreases in exudative age related macular degeneration
    • Mori F, Konno S, Hikichi T et al. (2001) Pulsatile ocular blood flow study: decreases in exudative age related macular degeneration. Br J Ophthalmol 85: 531-533
    • (2001) Br J Ophthalmol , vol.85 , pp. 531-533
    • Mori, F.1    Konno, S.2    Hikichi, T.3
  • 19
    • 2542624648 scopus 로고
    • Clinical tonography; the scleral rigidity correction
    • Moses RA, Becker B (1958) Clinical tonography; the scleral rigidity correction. Am J Ophthalmol 45: 196-208
    • (1958) Am J Ophthalmol , vol.45 , pp. 196-208
    • Moses, R.A.1    Becker, B.2
  • 20
    • 0035062925 scopus 로고    scopus 로고
    • The specific architecture of the anterior stroma ac counts for maintenance of corneal curvature
    • Muller LJ, Pels E, Vrensen GF (2001) The specific architecture of the anterior stroma ac counts for maintenance of corneal curvature. Br J Ophthalmol 85: 437-443
    • (2001) Br J Ophthalmol , vol.85 , pp. 437-443
    • Muller, L.J.1    Pels, E.2    Vrensen, G.F.3
  • 21
    • 0033021344 scopus 로고    scopus 로고
    • Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo
    • Orssengo G, Pye D (1999) Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull Mathematical Biol 61: 551-572
    • (1999) Bull Mathematical Biol , vol.61 , pp. 551-572
    • Orssengo, G.1    Pye, D.2
  • 22
    • 24944580479 scopus 로고    scopus 로고
    • Dynamic contour tonometry versus Goldmann applanation tonometry: A comparative study
    • Pache M, Wilmsmeyer S, Lautebach S et al. (2005) Dynamic contour tonometry versus Goldmann applanation tonometry: a comparative study. Graefes Arch Clin Exp Ophthalmol 243: 763-767
    • (2005) Graefes Arch Clin Exp Ophthalmol , vol.243 , pp. 763-767
    • Pache, M.1    Wilmsmeyer, S.2    Lautebach, S.3
  • 23
    • 0019795784 scopus 로고
    • The ocular pulse
    • Perkins ES (1981) The ocular pulse. Curr Eye Res 1: 19-23
    • (1981) Curr Eye Res , vol.1 , pp. 19-23
    • Perkins, E.S.1
  • 24
    • 0022368547 scopus 로고
    • The ocular pulse and intraocular pressure as a screening test for carotid artery stenosis
    • Perkins ES (1985) The ocular pulse and intraocular pressure as a screening test for carotid artery stenosis. Br J Ophthalmol 69: 676-680
    • (1985) Br J Ophthalmol , vol.69 , pp. 676-680
    • Perkins, E.S.1
  • 25
    • 30344436327 scopus 로고    scopus 로고
    • Intraocular pressure measurement - Comparison of dynamic contour tonometry and Goldmann applanation tonometry
    • Schneider E, Grehn F (2006) Intraocular pressure measurement - comparison of dynamic contour tonometry and Goldmann applanation tonometry. J Glaucoma 15: 2-6
    • (2006) J Glaucoma , vol.15 , pp. 2-6
    • Schneider, E.1    Grehn, F.2
  • 26
    • 13844318981 scopus 로고    scopus 로고
    • Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK
    • Siganos DS, Papastergiou GI, Moedas C (2004) Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK. J Cataract Refract Surg 40: 746-751
    • (2004) J Cataract Refract Surg , vol.40 , pp. 746-751
    • Siganos, D.S.1    Papastergiou, G.I.2    Moedas, C.3
  • 27
    • 0032948330 scopus 로고    scopus 로고
    • Disinfection of tonometers and contact lenses in the office setting: Are current techniques adequate?
    • Smith CA, Pepose JS (1999) Disinfection of tonometers and contact lenses in the office setting: are current techniques adequate? Am J Ophthalmol 127: 77-84
    • (1999) Am J Ophthalmol , vol.127 , pp. 77-84
    • Smith, C.A.1    Pepose, J.S.2
  • 28
    • 0031848594 scopus 로고    scopus 로고
    • Applanation tonometry and correction according to corneal thickness
    • Stodtmeister R (1998) Applanation tonometry and correction according to corneal thickness. Acta Ophthalmol Scand 76: 319-324
    • (1998) Acta Ophthalmol Scand , vol.76 , pp. 319-324
    • Stodtmeister, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.