메뉴 건너뛰기




Volumn 34, Issue 6, 2006, Pages 516-520

Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow pneumatonometer

Author keywords

Central corneal thickness; Conrneal curvature; Goldmann applanation tonometer; Intraocular pressure; Ocular blood flow pneumatonometer

Indexed keywords

ANTIGLAUCOMA AGENT;

EID: 33747346135     PISSN: 14426404     EISSN: 14429071     Source Type: Journal    
DOI: 10.1111/j.1442-9071.2006.01266.x     Document Type: Article
Times cited : (24)

References (22)
  • 2
    • 0016765823 scopus 로고
    • Biometric correlation of corneal thickness
    • Ehlers N, Hansen FK, Aasved H. Biometric correlation of corneal thickness. Acta Ophthalmol 1975; 53: 652-9.
    • (1975) Acta Ophthalmol , vol.53 , pp. 652-659
    • Ehlers, N.1    Hansen, F.K.2    Aasved, H.3
  • 3
    • 0027269723 scopus 로고
    • The effect of corneal thickness on applanation tonometry
    • Whiteacre MM, Stein RA, Hussanein K. The effect of corneal thickness on applanation tonometry. Am J Ophthalmol 1993; 115: 592-6.
    • (1993) Am J Ophthalmol , vol.115 , pp. 592-596
    • Whiteacre, M.M.1    Stein, R.A.2    Hussanein, K.3
  • 4
    • 0030963090 scopus 로고    scopus 로고
    • Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study
    • Wolfs RC, Klaver CC, Vingerling JR, Grobbee DE, Hofman A, de Jong PT. Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study. Am J Ophthalmol 1997; 123: 767-72.
    • (1997) Am J Ophthalmol , vol.123 , pp. 767-772
    • Wolfs, R.C.1    Klaver, C.C.2    Vingerling, J.R.3    Grobbee, D.E.4    Hofman, A.5    de Jong, P.T.6
  • 5
    • 0036235038 scopus 로고    scopus 로고
    • Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen
    • Bhan A, Browning AC, Shah S, Hamilton R, Dave D, Dua HS. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen. Invest Ophthalmol Vis Sci 2002; 43: 1389-92.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 1389-1392
    • Bhan, A.1    Browning, A.C.2    Shah, S.3    Hamilton, R.4    Dave, D.5    Dua, H.S.6
  • 6
    • 1842452811 scopus 로고    scopus 로고
    • Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer
    • Gunvant P, Baskaran M, Vijaya L et al. Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer. Br J Ophthalmol 2004; 88: 518-22.
    • (2004) Br J Ophthalmol , vol.88 , pp. 518-522
    • Gunvant, P.1    Baskaran, M.2    Vijaya, L.3
  • 7
    • 16844376246 scopus 로고    scopus 로고
    • Varying effects of corneal thickness on intraocular pressure measurements with different tonometers
    • Ko YC, Liu CJ, Hsu WM. Varying effects of corneal thickness on intraocular pressure measurements with different tonometers. Eye 2005; 19: 327-32.
    • (2005) Eye , vol.19 , pp. 327-332
    • Ko, Y.C.1    Liu, C.J.2    Hsu, W.M.3
  • 8
    • 0028791287 scopus 로고
    • Comparing methods of measurement: Why plotting difference against standard method is misleading
    • Bland A. Comparing methods of measurement: Why plotting difference against standard method is misleading. Lancet 1995; 346: 1085-7.
    • (1995) Lancet , vol.346 , pp. 1085-1087
    • Bland, A.1
  • 9
    • 0014274198 scopus 로고
    • A rapid pneumatic applanation tonometer. Comparative findings and evaluation
    • Langham ME, McCarthy E. A rapid pneumatic applanation tonometer. Comparative findings and evaluation. Arch Ophthalmol 1968; 79: 389-99.
    • (1968) Arch Ophthalmol , vol.79 , pp. 389-399
    • Langham, M.E.1    McCarthy, E.2
  • 10
    • 0015266386 scopus 로고
    • An experimental and theoretical study of the pneumatic tonometer
    • Walker RE, Litovitz TL. An experimental and theoretical study of the pneumatic tonometer. Exp Eye Res 1972; 13: 14-23.
    • (1972) Exp Eye Res , vol.13 , pp. 14-23
    • Walker, R.E.1    Litovitz, T.L.2
  • 11
    • 0032836524 scopus 로고    scopus 로고
    • Pneumotonometry versus Goldmann tonometry after laser in situ keratomileusis for myopia
    • Zadok D, Tran DB, Twa M, Carpenter M, Schanzlin DJ. Pneumotonometry versus Goldmann tonometry after laser in situ keratomileusis for myopia. J Cataract Refract Surg 1999; 25: 1344-8.
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1344-1348
    • Zadok, D.1    Tran, D.B.2    Twa, M.3    Carpenter, M.4    Schanzlin, D.J.5
  • 12
    • 0032470563 scopus 로고    scopus 로고
    • Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy
    • Abbasoglu OE, Bowman RW, Cavanagh HD, McCulley JP. Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy. Ophthalmology 1998; 105: 2193-6.
    • (1998) Ophthalmology , vol.105 , pp. 2193-2196
    • Abbasoglu, O.E.1    Bowman, R.W.2    Cavanagh, H.D.3    McCulley, J.P.4
  • 13
    • 0029788813 scopus 로고    scopus 로고
    • Effect of photorefractive keratectomy on the accuracy of pneumatonometer readings in rabbits
    • Tuunanen TH, Hamalainen P, Mali M, Oksala O, Tervo T. Effect of photorefractive keratectomy on the accuracy of pneumatonometer readings in rabbits. Invest Ophthalmol Vis Sci 1996; 37: 1810-14.
    • (1996) Invest Ophthalmol Vis Sci , vol.37 , pp. 1810-1814
    • Tuunanen, T.H.1    Hamalainen, P.2    Mali, M.3    Oksala, O.4    Tervo, T.5
  • 15
    • 21344456718 scopus 로고    scopus 로고
    • A comparison of four methods of tonometry: Method agreement and interobserver variability
    • Tonnu PA, Ho T, Sharma K, White E, Bunce C, Garway-Heath D. A comparison of four methods of tonometry: Method agreement and interobserver variability. Br J Ophthalmol 2005; 89: 847-50.
    • (2005) Br J Ophthalmol , vol.89 , pp. 847-850
    • Tonnu, P.A.1    Ho, T.2    Sharma, K.3    White, E.4    Bunce, C.5    Garway-Heath, D.6
  • 17
    • 7044264342 scopus 로고    scopus 로고
    • The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology
    • Browning AC, Bhan A, Rotchford AP, Shah S, Dua HS. The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology. Br J Ophthalmol 2004; 88: 1395-9.
    • (2004) Br J Ophthalmol , vol.88 , pp. 1395-1399
    • Browning, A.C.1    Bhan, A.2    Rotchford, A.P.3    Shah, S.4    Dua, H.S.5
  • 18
    • 15544365837 scopus 로고    scopus 로고
    • Central corneal thickness and intraocular pressure relationship in eyes with and without previous LASIK: Comparison of Goldmann applanation tonometer with pneumatonometer
    • Bayraktar S, Bayraktar Z. Central corneal thickness and intraocular pressure relationship in eyes with and without previous LASIK: comparison of Goldmann applanation tonometer with pneumatonometer. Eur J Ophthalmol 2005; 15: 81-8.
    • (2005) Eur J Ophthalmol , vol.15 , pp. 81-88
    • Bayraktar, S.1    Bayraktar, Z.2
  • 19
    • 0141682012 scopus 로고    scopus 로고
    • Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics, and African Americans
    • Shimmyo M, Ross AJ, Moy A, Mostafavi R. Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics, and African Americans. Am J Ophthalmol 2003; 136: 603-13.
    • (2003) Am J Ophthalmol , vol.136 , pp. 603-613
    • Shimmyo, M.1    Ross, A.J.2    Moy, A.3    Mostafavi, R.4
  • 20
    • 0036257336 scopus 로고    scopus 로고
    • Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik Eye Study
    • Eysteinsson T, Jonasson F, Sasaki H et al. Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik Eye Study. Acta Ophthalmol Scand 2002; 80: 11-15.
    • (2002) Acta Ophthalmol Scand , vol.80 , pp. 11-15
    • Eysteinsson, T.1    Jonasson, F.2    Sasaki, H.3
  • 21
    • 0034441936 scopus 로고    scopus 로고
    • Influence of keratometric readings on comparative intraocular pressure measurements with Goldmann, Tono-Pen, and noncontact tonometers
    • Paranhos A Jr, Paranhos FR, Prata JA Jr, Omi CA, Mello PA, Shields MB. Influence of keratometric readings on comparative intraocular pressure measurements with Goldmann, Tono-Pen, and noncontact tonometers. J Glaucoma 2000; 9: 219-23.
    • (2000) J Glaucoma , vol.9 , pp. 219-223
    • Paranhos Jr., A.1    Paranhos, F.R.2    Prata Jr., J.A.3    Omi, C.A.4    Mello, P.A.5    Shields, M.B.6
  • 22
    • 0015878930 scopus 로고
    • Corneal curvature in applanation tonometry
    • Mark HH. Corneal curvature in applanation tonometry. Am J Ophthalmol 1973; 76: 223-4.
    • (1973) , vol.76 , pp. 223-224
    • Mark, H.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.