Volumn 221, Issue 9, 2004, Pages 762-768

Prospective comparison of the new indentation tonometer TGdC-01, the non-contact tonometer PT100 and the conventional Goldmann applanation tonometer;Prospektiver vergleich des neuen impressionstonometers TGDC-01 und des non-kontakt-tonometers PT 100 mit der etablierten Goldmann- applanationstonometrie

Author keywords

Goldmann applanation tonometry; Indentation tonometry; Non contact tonometry

Indexed keywords

ACCURACY; ADULT; ARTICLE; BIOMEDICAL TECHNOLOGY ASSESSMENT; CONTROLLED STUDY; FEMALE; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; INTRAOCULAR PRESSURE; MALE; NORMAL HUMAN; OCULOPLETHYSMOGRAPHY; TONOMETER;

EID: 6344221844     PISSN: 00232165     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2004-813566     Document Type: Article
Times cited : (20)

References (14)
  • 1
    • 0031840565 scopus 로고    scopus 로고
    • Changing definition of glaucoma
    • Bathija R, Gupta N, Zangwill L et al. Changing definition of glaucoma. J Glaucoma 1998; 7: 165-169
    • (1998) J Glaucoma , vol.7 , pp. 165-169
    • Bathija, R.1    Gupta, N.2    Zangwill, L.3
  • 2
    • 84908219488 scopus 로고
    • Statistical methods for assesing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assesing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 3
    • 0033589732 scopus 로고    scopus 로고
    • Glaucoma
    • Coleman AL. Glaucoma. Lancet 1999; 354:1803-1810
    • (1999) Lancet , vol.354 , pp. 1803-1810
    • Coleman, A.L.1
  • 5
    • 0034157968 scopus 로고    scopus 로고
    • Tonometry in normal and scarred corneas, and in postkeratoplasty eyes: A comparative study of the Goldmann, the ProTon and the Schiotz tonometers
    • Jain AK, Saini JS, Gupta R. Tonometry in normal and scarred corneas, and in postkeratoplasty eyes: a comparative study of the Goldmann, the ProTon and the Schiotz tonometers. Indian J Ophthalmo 2000; 48: 25-32
    • (2000) Indian J Ophthalmo , vol.48 , pp. 25-32
    • Jain, A.K.1    Saini, J.S.2    Gupta, R.3
  • 8
    • 0036482727 scopus 로고    scopus 로고
    • Clinical evaluation of the Keeler Pulsair 3000 non-contact tonometer
    • Lawson-Kopp W, de Jong A, Yudcovitch L et al. Clinical evaluation of the Keeler Pulsair 3000 non-contact tonometer. Optometry 2002; 73: 81-90
    • (2002) Optometry , vol.73 , pp. 81-90
    • Lawson-Kopp, W.1    De Jong, A.2    Yudcovitch, L.3
  • 11
    • 0031003564 scopus 로고    scopus 로고
    • A comparison of intraocular pressure measurements with the XPERT non contact tonometer and Goldmann applanation tonometry
    • Popovich KS, Shields MB. A comparison of intraocular pressure measurements with the XPERT non contact tonometer and Goldmann applanation tonometry. J Glaucoma 1997; 6: 44-46
    • (1997) J Glaucoma , vol.6 , pp. 44-46
    • Popovich, K.S.1    Shields, M.B.2
  • 13
    • 0004257968 scopus 로고    scopus 로고
    • Philadelphia, London, Paris: Williams & Wilkins: Fourth edition: 3-71
    • Shields MB. Textbook of glaucoma. Philadelphia, London, Paris: Williams & Wilkins, 1997: Fourth edition: 3-71
    • (1997) Textbook of Glaucoma
    • Shields, M.B.1
  • 14
    • 0036872981 scopus 로고    scopus 로고
    • Comparison of precision of the TonoPenXL with the goldmann and draeger applanation tonometer in a sitting and recumbent position of the patients - A clinical study on 251 eyes
    • Viestenz A, Lausen B, Junemann AM et al. Comparison of Precision of the TonoPenXL with the Goldmann and Draeger Applanation Tonometer in a Sitting and Recumbent Position of the Patients - A Clinical Study on 251 Eyes. Klin Monatsbl Augenheilkd 2002; 219: 785-790
    • (2002) Klin Monatsbl Augenheilkd , vol.219 , pp. 785-790
    • Viestenz, A.1    Lausen, B.2    Junemann, A.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.