메뉴 건너뛰기




Volumn 34, Issue 7, 2006, Pages 666-670

Telemedicine-friendly, portable tonometers: An evaluation for intraocular pressure screening

Author keywords

Digital; Glaucoma; Screening; Tonometry

Indexed keywords

ADULT; AGED; ANTERIOR EYE CHAMBER DEPTH; ARTICLE; CONTROLLED STUDY; CORNEA THICKNESS; DIAGNOSTIC VALUE; DIGITAL IMAGING; FEMALE; GLAUCOMA; HUMAN; INTERMETHOD COMPARISON; INTRAOCULAR PRESSURE ABNORMALITY; MAJOR CLINICAL STUDY; MALE; PORTABLE EQUIPMENT; READING; REFRACTION ERROR; SCREENING TEST; SENSITIVITY AND SPECIFICITY; STANDARDIZATION; STATISTICAL SIGNIFICANCE; TELEMEDICINE; TONOMETER; VISUAL SYSTEM EXAMINATION; VISUAL THRESHOLD;

EID: 33748565924     PISSN: 14426404     EISSN: 14429071     Source Type: Journal    
DOI: 10.1111/j.1442-9071.2006.01304.x     Document Type: Article
Times cited : (18)

References (29)
  • 1
    • 0029980777 scopus 로고    scopus 로고
    • Number of people with glaucoma worldwide
    • Quigley HA. Number of people with glaucoma worldwide. Br J Ophthalmol 1996; 80: 389-93.
    • (1996) Br J Ophthalmol , vol.80 , pp. 389-393
    • Quigley, H.A.1
  • 2
    • 33646902382 scopus 로고    scopus 로고
    • Glaucoma screening: Current trends, economic issues, technology, and challenges
    • Nduaguba C, Lee RK. Glaucoma screening: Current trends, economic issues, technology, and challenges. Curr Opin Ophthalmol 2006; 17: 142-52.
    • (2006) Curr Opin Ophthalmol , vol.17 , pp. 142-152
    • Nduaguba, C.1    Lee, R.K.2
  • 3
    • 26244449075 scopus 로고    scopus 로고
    • Internet-based eye care: Vision 2020
    • Sajeesh KR, Yogesan K. Internet-based eye care: Vision 2020. Lancet 2005; 366: 1244-5.
    • (2005) Lancet , vol.366 , pp. 1244-1245
    • Sajeesh, K.R.1    Yogesan, K.2
  • 5
    • 1142299596 scopus 로고    scopus 로고
    • Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic
    • Kontiola A, Puska P. Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic. Graefes Arch Clin Exp Ophthalmol 2004; 242: 3-7.
    • (2004) Graefes Arch Clin Exp Ophthalmol , vol.242 , pp. 3-7
    • Kontiola, A.1    Puska, P.2
  • 6
    • 33644629030 scopus 로고    scopus 로고
    • Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes
    • Garcia-Resua C, Gonzalez-Meijome JM, Gilino J, Yebra-Pimentel E. Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes. Optom Vis Sci 2006; 83: 102-7.
    • (2006) Optom Vis Sci , vol.83 , pp. 102-107
    • Garcia-Resua, C.1    Gonzalez-Meijome, J.M.2    Gilino, J.3    Yebra-Pimentel, E.4
  • 8
    • 0034971648 scopus 로고    scopus 로고
    • Central corneal thickness, tonometry, and ocular dimensions in glaucoma and ocular hypertension
    • Singh RP, Goldberg I. Central corneal thickness, tonometry, and ocular dimensions in glaucoma and ocular hypertension. J Glaucoma 2001; 10: 206-10.
    • (2001) J Glaucoma , vol.10 , pp. 206-210
    • Singh, R.P.1    Goldberg, I.2
  • 9
    • 0036831268 scopus 로고    scopus 로고
    • Central corneal thickness in European (white) individuals, especially children and the elderly, and assessment of its possible importance in clinical measures of intra-ocular pressure
    • Doughty MJ, Laiquzzaman M. Central corneal thickness in European (white) individuals, especially children and the elderly, and assessment of its possible importance in clinical measures of intra-ocular pressure. Ophthalmic Physiol Opt 2002; 22: 491-504.
    • (2002) Ophthalmic Physiol Opt , vol.22 , pp. 491-504
    • Doughty, M.J.1    Laiquzzaman, M.2
  • 10
    • 0027291601 scopus 로고
    • Sources of error with use of Goldmann-type tonometers
    • Whitacre MM, Stein R. Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol 1993; 38: 1-30.
    • (1993) Surv Ophthalmol , vol.38 , pp. 1-30
    • Whitacre, M.M.1    Stein, R.2
  • 11
    • 0037226572 scopus 로고    scopus 로고
    • Refractive errors, intraocular pressure, and glaucoma in a white population
    • Wong TY, Klein BE. Refractive errors, intraocular pressure, and glaucoma in a white population. Ophthalmology 2003; 110: 211-17.
    • (2003) Ophthalmology , vol.110 , pp. 211-217
    • Wong, T.Y.1    Klein, B.E.2
  • 12
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999; 8: 135-60.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurements
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurements. Lancet 1986; 1 (8476): 307-10.
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 3242658099 scopus 로고    scopus 로고
    • Open-angle glaucoma and systemic hypertension: The Blue Mountains eye study
    • Mitchell P, Lee AJ, Rotchina E, Wang JJ. Open-angle glaucoma and systemic hypertension: The Blue Mountains eye study. J Glaucoma 2004; 13: 319-26.
    • (2004) J Glaucoma , vol.13 , pp. 319-326
    • Mitchell, P.1    Lee, A.J.2    Rotchina, E.3    Wang, J.J.4
  • 15
    • 0034754247 scopus 로고    scopus 로고
    • Prevalence and predictors of open-angle glaucoma: Results from the visual impairment project
    • Weih LM, Nanjan M, McCarty CA, Taylor HR. Prevalence and predictors of open-angle glaucoma: Results from the visual impairment project. Ophthalmology 2001; 108: 1966-72.
    • (2001) Ophthalmology , vol.108 , pp. 1966-1972
    • Weih, L.M.1    Nanjan, M.2    McCarty, C.A.3    Taylor, H.R.4
  • 16
    • 24944488907 scopus 로고    scopus 로고
    • Screening for glaucoma. Waiting until our vision clears
    • Harris R. Screening for glaucoma. Waiting until our vision clears. Br Med J 2005; 331: E376-7.
    • (2005) Br Med J , vol.331
    • Harris, R.1
  • 17
    • 22344433712 scopus 로고    scopus 로고
    • Treatment of ocular hypertension and open angle glaucoma: Meta-analysis of randomised controlled trials
    • Maier PC, Funk J, Schwarzer G, Antes G, Falck-Ytter YT. Treatment of ocular hypertension and open angle glaucoma: Meta-analysis of randomised controlled trials. Br Med J 2005; 331: 134.
    • (2005) Br Med J , vol.331 , pp. 134
    • Maier, P.C.1    Funk, J.2    Schwarzer, G.3    Antes, G.4    Falck-Ytter, Y.T.5
  • 18
    • 27744606520 scopus 로고    scopus 로고
    • Rationale for the USPSTF recommendation on screening for glaucoma
    • Guirguis J. Rationale for the USPSTF recommendation on screening for glaucoma. Am Fam Physician 2005; 72: 1187.
    • (2005) Am Fam Physician , vol.72 , pp. 1187
    • Guirguis, J.1
  • 19
    • 16444375302 scopus 로고    scopus 로고
    • Screening for primary open-angle glaucoma in the primary care setting: An update for the US Preventive Services Task Force
    • Fleming C, Whitlock E, Beil T, Smit B, Harris RP. Screening for primary open-angle glaucoma in the primary care setting: An update for the US Preventive Services Task Force. Ann Fam Med 2005; 3: 167-70.
    • (2005) Ann Fam Med , vol.3 , pp. 167-170
    • Fleming, C.1    Whitlock, E.2    Beil, T.3    Smit, B.4    Harris, R.P.5
  • 21
    • 0343719249 scopus 로고
    • Testing for glaucoma: The first IGA survey revisited
    • Tuck MW. Testing for glaucoma: The first IGA survey revisited. Optician 1990; 8: 16-17.
    • (1990) Optician , vol.8 , pp. 16-17
    • Tuck, M.W.1
  • 22
    • 0018903467 scopus 로고
    • The non-contact tonometer. Its value and limitations
    • Shields MB. The non-contact tonometer. Its value and limitations. Surv Ophthalmol 1980; 24: 211-19.
    • (1980) Surv Ophthalmol , vol.24 , pp. 211-219
    • Shields, M.B.1
  • 23
    • 0017128049 scopus 로고
    • Premature ventricular systole detection by applanation tonometry
    • Lichter PR, Bergstrom TJ. Premature ventricular systole detection by applanation tonometry. Am J Ophthalmol 1976; 81: 797-803.
    • (1976) Am J Ophthalmol , vol.81 , pp. 797-803
    • Lichter, P.R.1    Bergstrom, T.J.2
  • 24
    • 0020597793 scopus 로고
    • Goldmann applanation tonometry in patients with regular corneal astigmatism
    • Holladay JT, Allison ME, Prager TC. Goldmann applanation tonometry in patients with regular corneal astigmatism. Am J Ophthalmol 1983; 96: 90-3.
    • (1983) Am J Ophthalmol , vol.96 , pp. 90-93
    • Holladay, J.T.1    Allison, M.E.2    Prager, T.C.3
  • 26
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach. Surv Ophthalmol 2000; 44: 367-408.
    • (2000) Surv Ophthalmol , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 27
    • 0035164733 scopus 로고    scopus 로고
    • Relation between corneal thickness and intraocular pressure measurement by noncontact and applanation tonometry
    • Recep OF, Hasiripi H, Cagil N, Sarikatipoglu H. Relation between corneal thickness and intraocular pressure measurement by noncontact and applanation tonometry. J Cataract Refract Surg 2001; 27: 1787-91.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1787-1791
    • Recep, O.F.1    Hasiripi, H.2    Cagil, N.3    Sarikatipoglu, H.4
  • 28
    • 0033211071 scopus 로고    scopus 로고
    • The relationship between glaucoma and myopia: The Blue Mountains Eye Study
    • Mitchell P, Hourihan F, Sandbach J, Wang JJ. The relationship between glaucoma and myopia: The Blue Mountains Eye Study. Ophthalmology 1999; 106: 2010-15.
    • (1999) Ophthalmology , vol.106 , pp. 2010-2015
    • Mitchell, P.1    Hourihan, F.2    Sandbach, J.3    Wang, J.J.4
  • 29
    • 0027200297 scopus 로고
    • Accuracy of Goldmann tonometry in clinical practice
    • Sudesh S, Moseley MJ, Thompson JR. Accuracy of Goldmann tonometry in clinical practice. Acta Ophthalmol 1993; 71: 185-8.
    • (1993) Acta Ophthalmol , vol.71 , pp. 185-188
    • Sudesh, S.1    Moseley, M.J.2    Thompson, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.