메뉴 건너뛰기




Volumn 21, Issue 6, 2010, Pages 879-889

Quantitative top-down proteomics of SILAC labeled human embryonic stem cells

Author keywords

[No Author keywords available]

Indexed keywords

EXPERIMENTAL CONDITIONS; FOURIER TRANSFORM ION CYCLOTRON RESONANCE MASS SPECTROMETERS; HUMAN EMBRYONIC STEM CELLS; IN-CELL; INTACT PROTEINS; ION TRAPS; MEDICAL CONDITIONS; METABOLIC LABELING; PLURIPOTENCY; PLURIPOTENT; PROTEOMES; PROTEOMICS; QUANTITATIVE COMPARISON; REVERSE PHASE CHROMATOGRAPHY; STABLE-ISOTOPE LABELING; TOPDOWN;

EID: 77952876849     PISSN: 10440305     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jasms.2010.01.031     Document Type: Article
Times cited : (43)

References (44)
  • 1
    • 27644495875 scopus 로고    scopus 로고
    • Human Embryonic Stem Cells: An In Vitro Model to Study Mechanisms Controlling Pluripotency in Early Mammalian Development
    • Vallier L., Pedersen R.A. Human Embryonic Stem Cells: An In Vitro Model to Study Mechanisms Controlling Pluripotency in Early Mammalian Development. Stem Cell Rev. 2005, 1:119-130.
    • (2005) Stem Cell Rev. , vol.1 , pp. 119-130
    • Vallier, L.1    Pedersen, R.A.2
  • 2
    • 2642520417 scopus 로고    scopus 로고
    • Top-Down Proteomics
    • Kelleher N.L. Top-Down Proteomics. Anal. Chem. 2004, 76(11):196A-203A.
    • (2004) Anal. Chem. , vol.76 , Issue.11
    • Kelleher, N.L.1
  • 3
    • 14744304574 scopus 로고    scopus 로고
    • Proteomics by FTICR Mass Spectrometry: Top Down and Bottom Up
    • Bogdanov B., Smith R.D. Proteomics by FTICR Mass Spectrometry: Top Down and Bottom Up. Mass Spectrom. Rev. 2005, 24(2):168-200.
    • (2005) Mass Spectrom. Rev. , vol.24 , Issue.2 , pp. 168-200
    • Bogdanov, B.1    Smith, R.D.2
  • 4
    • 0032455894 scopus 로고    scopus 로고
    • Efficient Sequence Analysis of the Six Gene Products (7-74 kDa) from the Escherichia coli Thiamin Biosynthetic Operon by Tandem High-Resolution Mass Spectrometry
    • Kelleher N.L., Taylor S.V., Grannis D., Kinsland C., Chiu H.J., Begley T.P., McLafferty F.W. Efficient Sequence Analysis of the Six Gene Products (7-74 kDa) from the Escherichia coli Thiamin Biosynthetic Operon by Tandem High-Resolution Mass Spectrometry. Protein Sci. 1998, 7(8):1796-1801.
    • (1998) Protein Sci. , vol.7 , Issue.8 , pp. 1796-1801
    • Kelleher, N.L.1    Taylor, S.V.2    Grannis, D.3    Kinsland, C.4    Chiu, H.J.5    Begley, T.P.6    McLafferty, F.W.7
  • 5
    • 0037196338 scopus 로고    scopus 로고
    • Top Down Characterization of Larger Proteins (45 kDa) by Electron Capture Dissociation Mass Spectrometry
    • Ge Y., Lawhorn B.G., ElNaggar M., Strauss E., Park J.H., Begley T.P., McLafferty F.W. Top Down Characterization of Larger Proteins (45 kDa) by Electron Capture Dissociation Mass Spectrometry. J. Am. Chem. Soc. 2002, 124(4):672-678.
    • (2002) J. Am. Chem. Soc. , vol.124 , Issue.4 , pp. 672-678
    • Ge, Y.1    Lawhorn, B.G.2    ElNaggar, M.3    Strauss, E.4    Park, J.H.5    Begley, T.P.6    McLafferty, F.W.7
  • 6
    • 2442636680 scopus 로고    scopus 로고
    • Molecular-Level Description of Proteins from Saccharomyces cerevisiae Using Quadrupole FT Hybrid Mass Spectrometry for Top Down Proteomics
    • Meng F.Y., Du Y., Miller L.M., Patrie S.M., Robinson D.E., Kelleher N.L. Molecular-Level Description of Proteins from Saccharomyces cerevisiae Using Quadrupole FT Hybrid Mass Spectrometry for Top Down Proteomics. Anal. Chem. 2004, 76(10):2852-2858.
    • (2004) Anal. Chem. , vol.76 , Issue.10 , pp. 2852-2858
    • Meng, F.Y.1    Du, Y.2    Miller, L.M.3    Patrie, S.M.4    Robinson, D.E.5    Kelleher, N.L.6
  • 7
    • 35848949043 scopus 로고    scopus 로고
    • Decoding Protein Modifications Using Top-Down Mass Spectrometry
    • Siuti N., Kelleher N.L. Decoding Protein Modifications Using Top-Down Mass Spectrometry. Nat. Methods 2007, 4(10):817-821.
    • (2007) Nat. Methods , vol.4 , Issue.10 , pp. 817-821
    • Siuti, N.1    Kelleher, N.L.2
  • 8
    • 5644302352 scopus 로고    scopus 로고
    • Development of an Analytical Reversed-Phase High-Performance Liquid Chromatograph Electrospray Ionization Mass Spectrometry Method for Characterization of Recombinant Antibodies
    • Dillon T.M., Bondarenko P.V., Ricci M.S. Development of an Analytical Reversed-Phase High-Performance Liquid Chromatograph Electrospray Ionization Mass Spectrometry Method for Characterization of Recombinant Antibodies. J. Chromatogr. A 2004, 1053(1053):299-305.
    • (2004) J. Chromatogr. A , vol.1053 , Issue.1053 , pp. 299-305
    • Dillon, T.M.1    Bondarenko, P.V.2    Ricci, M.S.3
  • 9
    • 68049099249 scopus 로고    scopus 로고
    • Multiplexed Size Separation of Intact Proteins in Solution Phase for Mass Spectrometry
    • Tran J.C., Doucette A.A. Multiplexed Size Separation of Intact Proteins in Solution Phase for Mass Spectrometry. Anal. Chem. 2009, 81(15):6201-6209.
    • (2009) Anal. Chem. , vol.81 , Issue.15 , pp. 6201-6209
    • Tran, J.C.1    Doucette, A.A.2
  • 10
    • 41149161152 scopus 로고    scopus 로고
    • Gel-Eluted Liquid Fraction Entrapment Electrophoresis: An Electrophoretic Method for Broad Molecular Weight Range Proteome Separation
    • Tran J.C., Doucette A.A. Gel-Eluted Liquid Fraction Entrapment Electrophoresis: An Electrophoretic Method for Broad Molecular Weight Range Proteome Separation. Anal. Chem. 2008, 80(5):1568-1573.
    • (2008) Anal. Chem. , vol.80 , Issue.5 , pp. 1568-1573
    • Tran, J.C.1    Doucette, A.A.2
  • 11
    • 17444413879 scopus 로고    scopus 로고
    • Effects of Chromatography Conditions on Intact Protein Separations for Top-Down Proteomics
    • Wang Y., Balgley B.M., Rudnick P.A., Lee C.S. Effects of Chromatography Conditions on Intact Protein Separations for Top-Down Proteomics. J. Chromatogr. A 2005, 1073:35-41.
    • (2005) J. Chromatogr. A , vol.1073 , pp. 35-41
    • Wang, Y.1    Balgley, B.M.2    Rudnick, P.A.3    Lee, C.S.4
  • 14
    • 30744476222 scopus 로고    scopus 로고
    • Performance of a Linear Ion Trap-Orbitrap Hybrid for Peptide Analysis
    • Yates J.R., Cociorva D., Liao L.J., Zabrouskov V. Performance of a Linear Ion Trap-Orbitrap Hybrid for Peptide Analysis. Anal. Chem. 2006, 78(2):493-500.
    • (2006) Anal. Chem. , vol.78 , Issue.2 , pp. 493-500
    • Yates, J.R.1    Cociorva, D.2    Liao, L.J.3    Zabrouskov, V.4
  • 16
    • 47249157351 scopus 로고    scopus 로고
    • Combinatorial Modification of Human Histone H4 Quantitated by Two-dimensional Liquid Chromatography Coupled with Top-Down Mass Spectrometry
    • Pesavento J.J., Bullock C.R., LeDuc R.D., Mizzen C.A., Kelleher N.L. Combinatorial Modification of Human Histone H4 Quantitated by Two-dimensional Liquid Chromatography Coupled with Top-Down Mass Spectrometry. J. Biol. Chem. 2008, 283(22):1427-1437.
    • (2008) J. Biol. Chem. , vol.283 , Issue.22 , pp. 1427-1437
    • Pesavento, J.J.1    Bullock, C.R.2    LeDuc, R.D.3    Mizzen, C.A.4    Kelleher, N.L.5
  • 18
    • 62449191449 scopus 로고    scopus 로고
    • Acid Sequence Polymorphisms in Rat Cardiac Troponin Revealed by Top-Down Tandem Mass Spectrometry
    • Solis R.S., Ge Y., Walker J.W., Single Amino Acid Sequence Polymorphisms in Rat Cardiac Troponin Revealed by Top-Down Tandem Mass Spectrometry. J. Muscle Res. Cell Motil. 2008, 29:203-212.
    • (2008) J. Muscle Res. Cell Motil. , vol.29 , pp. 203-212
    • Solis, R.S.1    Ge, Y.2    Walker, J.W.3    Single, A.4
  • 20
    • 0032863043 scopus 로고    scopus 로고
    • Hydropathic Influences on the Quantification of Equine Heart Cytochrome c Using Relative Ion Abundance Measurements by Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    • Gordon E.F., Mansoori B.A., Carroll C.F., Muddiman D.C. Hydropathic Influences on the Quantification of Equine Heart Cytochrome c Using Relative Ion Abundance Measurements by Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. J. Mass Spectrom 1999, 34(10):1055-1062.
    • (1999) J. Mass Spectrom , vol.34 , Issue.10 , pp. 1055-1062
    • Gordon, E.F.1    Mansoori, B.A.2    Carroll, C.F.3    Muddiman, D.C.4
  • 23
    • 3543121341 scopus 로고    scopus 로고
    • Quantification in Proteomics Through Stable Isotope Coding: A review
    • Julka S., Regnier F. Quantification in Proteomics Through Stable Isotope Coding: A review. J. Proteome Res. 2004, 3(3):350-363.
    • (2004) J. Proteome Res. , vol.3 , Issue.3 , pp. 350-363
    • Julka, S.1    Regnier, F.2
  • 24
    • 0035499083 scopus 로고    scopus 로고
    • Fractionation of Isotopically Labeled Peptides in Quantitative Proteomics
    • Zhang R.J., Sioma C.S., Wang S.H., Regnier F.E. Fractionation of Isotopically Labeled Peptides in Quantitative Proteomics. Anal. Chem. 2001, 73(21):5142-5149.
    • (2001) Anal. Chem. , vol.73 , Issue.21 , pp. 5142-5149
    • Zhang, R.J.1    Sioma, C.S.2    Wang, S.H.3    Regnier, F.E.4
  • 25
    • 32444436985 scopus 로고    scopus 로고
    • Top-Down Approaches for Measuring Expression Ratios of Intact Yeast Proteins Using Fourier Transform Mass Spectrometry
    • Du Y., Parks B.A., Sohn S., Kwast K.E., Kelleher N.L. Top-Down Approaches for Measuring Expression Ratios of Intact Yeast Proteins Using Fourier Transform Mass Spectrometry. Anal. Chem. 2006, 78(3):686-694.
    • (2006) Anal. Chem. , vol.78 , Issue.3 , pp. 686-694
    • Du, Y.1    Parks, B.A.2    Sohn, S.3    Kwast, K.E.4    Kelleher, N.L.5
  • 26
    • 0036583926 scopus 로고    scopus 로고
    • Stable Isotope Labeling by Amino Acids in Cell Culture, SILAC, as a Simple and Accurate Approach to Expression Proteomics
    • Ong S., Blagoev B., Kratchmarova I., Kristensen D.B., Steen H., Pandey A., Mann M. Stable Isotope Labeling by Amino Acids in Cell Culture, SILAC, as a Simple and Accurate Approach to Expression Proteomics. Mol. Cell. Proteom. 2002, 1(5):376-386.
    • (2002) Mol. Cell. Proteom. , vol.1 , Issue.5 , pp. 376-386
    • Ong, S.1    Blagoev, B.2    Kratchmarova, I.3    Kristensen, D.B.4    Steen, H.5    Pandey, A.6    Mann, M.7
  • 27
    • 0012351964 scopus 로고    scopus 로고
    • Properties of 13C-Substituted Arginine in Stable Isotope Labeling by Amino Acids in Cell Culture (SILAC)
    • Ong S., Kratchmarova I., Mann M. Properties of 13C-Substituted Arginine in Stable Isotope Labeling by Amino Acids in Cell Culture (SILAC). J. Proteome Res. 2003, 2:173-181.
    • (2003) J. Proteome Res. , vol.2 , pp. 173-181
    • Ong, S.1    Kratchmarova, I.2    Mann, M.3
  • 28
    • 35448967750 scopus 로고    scopus 로고
    • Top-Down Quantitation and Characterization of SILAC-Labeled Proteins
    • Waanders L.F., Hanke S., Mann M. Top-Down Quantitation and Characterization of SILAC-Labeled Proteins. J. Am. Soc. Mass Spectrom. 2007, 18(11):2058-2064.
    • (2007) J. Am. Soc. Mass Spectrom. , vol.18 , Issue.11 , pp. 2058-2064
    • Waanders, L.F.1    Hanke, S.2    Mann, M.3
  • 29
    • 46849122859 scopus 로고    scopus 로고
    • Top-Down Identification and Quantification of Stable Isotope Labeled Proteins from Aspergillus flavus Using On-Line Nano-Flow Reversed-Phase Liquid Chromatography Coupled to a LTQ-FTICR Mass Spectrometer
    • Collier T.S., Hawkridge A.M., Georgianna D.R., Payne G.A., Muddiman D.C. Top-Down Identification and Quantification of Stable Isotope Labeled Proteins from Aspergillus flavus Using On-Line Nano-Flow Reversed-Phase Liquid Chromatography Coupled to a LTQ-FTICR Mass Spectrometer. Anal. Chem. 2008, 80(13):4994-5001.
    • (2008) Anal. Chem. , vol.80 , Issue.13 , pp. 4994-5001
    • Collier, T.S.1    Hawkridge, A.M.2    Georgianna, D.R.3    Payne, G.A.4    Muddiman, D.C.5
  • 31
    • 59049086847 scopus 로고    scopus 로고
    • Human Embryonic Stem Cell Phosphoproteome Revealed by Electron Transfer Dissociation Tandem Mass Spectrometry
    • Swaney D., Wenger C.D., Thomson J.A., Coon J.J. Human Embryonic Stem Cell Phosphoproteome Revealed by Electron Transfer Dissociation Tandem Mass Spectrometry. Proc. Nat. Acad. Sci. U.S.A. 2009, 106(4):995-1000.
    • (2009) Proc. Nat. Acad. Sci. U.S.A. , vol.106 , Issue.4 , pp. 995-1000
    • Swaney, D.1    Wenger, C.D.2    Thomson, J.A.3    Coon, J.J.4
  • 35
    • 42649132889 scopus 로고    scopus 로고
    • Stable Isotope Labeling by Amino Acids in Cell Culture (SILAC) and Proteome Quantitation of Mouse Embryonic Stem Cells to a Depth of 5111 Proteins
    • Graumann J., Hubner N.C., Kim J.B., Ko K., Moser M., Kumar C., Cox J., Scholer H., Mann M. Stable Isotope Labeling by Amino Acids in Cell Culture (SILAC) and Proteome Quantitation of Mouse Embryonic Stem Cells to a Depth of 5111 Proteins. Mol. Cell. Proteom. 2008, 7(4):672-683.
    • (2008) Mol. Cell. Proteom. , vol.7 , Issue.4 , pp. 672-683
    • Graumann, J.1    Hubner, N.C.2    Kim, J.B.3    Ko, K.4    Moser, M.5    Kumar, C.6    Cox, J.7    Scholer, H.8    Mann, M.9
  • 36
    • 67449107495 scopus 로고    scopus 로고
    • Stable Isotope Labeling by Amino Acids in Cell Culture (SILAC) and Quantitative Comparison of the Membrane Proteomes of Self-Renewing and Differentiating Human Embryonic Stem Cells
    • Prokhorova T.A., Rigbolt K.T., Johansen P.T., Henningsen J., Kratchmarova I., Kassem M., Blagoev B. Stable Isotope Labeling by Amino Acids in Cell Culture (SILAC) and Quantitative Comparison of the Membrane Proteomes of Self-Renewing and Differentiating Human Embryonic Stem Cells. Mol. Cell. Proteom. 2009, 8:959-970.
    • (2009) Mol. Cell. Proteom. , vol.8 , pp. 959-970
    • Prokhorova, T.A.1    Rigbolt, K.T.2    Johansen, P.T.3    Henningsen, J.4    Kratchmarova, I.5    Kassem, M.6    Blagoev, B.7
  • 38
    • 34548356772 scopus 로고    scopus 로고
    • An Experimental Correction for Arginine to Proline Conversion Artifacts in SILAC-Based Quantitative Proteomics
    • Van Hoof D., Pinkse M.W., Oostwaard D.W., Mummery C.L., Heck A.J., Krijgsveld J. An Experimental Correction for Arginine to Proline Conversion Artifacts in SILAC-Based Quantitative Proteomics. Nat. Methods 2007, 4:677-678.
    • (2007) Nat. Methods , vol.4 , pp. 677-678
    • Van Hoof, D.1    Pinkse, M.W.2    Oostwaard, D.W.3    Mummery, C.L.4    Heck, A.J.5    Krijgsveld, J.6
  • 39
    • 77952877745 scopus 로고    scopus 로고
    • Embryonic Stem Cell Serum Replacement. International patent application WO98/30679
    • Price, P. J., Goldsborough, M. D., Tilkin, M. L. Embryonic Stem Cell Serum Replacement. International patent application WO98/30679, 1998.
    • (1998)
    • Price, P.J.1    Goldsborough, M.D.2    Tilkin, M.L.3
  • 40
    • 0032529079 scopus 로고    scopus 로고
    • Concentration and Desalting of Protein Samples for Mass Spectrometry Analysis
    • Winston R.L., Fitzgerald M.C. Concentration and Desalting of Protein Samples for Mass Spectrometry Analysis. Anal. Biochem. 1998, 262:83-85.
    • (1998) Anal. Biochem. , vol.262 , pp. 83-85
    • Winston, R.L.1    Fitzgerald, M.C.2
  • 42
    • 62249095261 scopus 로고    scopus 로고
    • Coupling of a Vented Column with Splitless NanoRPLC-ESI-MS for the Improved Separation and Detection of Brain Natriuretic Peptide-32 and Its Proteolytic Peptides
    • Andrews G.L., Shuford C.M., Burnett J.C., Hawkridge A.M., Muddiman D.C. Coupling of a Vented Column with Splitless NanoRPLC-ESI-MS for the Improved Separation and Detection of Brain Natriuretic Peptide-32 and Its Proteolytic Peptides. J. Chrom. B 2009, 877(10):948-954.
    • (2009) J. Chrom. B , vol.877 , Issue.10 , pp. 948-954
    • Andrews, G.L.1    Shuford, C.M.2    Burnett, J.C.3    Hawkridge, A.M.4    Muddiman, D.C.5
  • 43
    • 0033434080 scopus 로고    scopus 로고
    • Probability-Based Protein Identification by Searching Sequence Databases Using Mass Spectrometry data
    • Perkins D.N., Pappin D.J.C., Creasy D.M., Cottrell J.S. Probability-Based Protein Identification by Searching Sequence Databases Using Mass Spectrometry data. Electrophoresis 1999, 20(18):3551-3567.
    • (1999) Electrophoresis , vol.20 , Issue.18 , pp. 3551-3567
    • Perkins, D.N.1    Pappin, D.J.C.2    Creasy, D.M.3    Cottrell, J.S.4
  • 44


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.