메뉴 건너뛰기




Volumn 16, Issue 5, 2010, Pages 723-734

Manufacturing, assembling and packaging of miniaturized neural implants

Author keywords

[No Author keywords available]

Indexed keywords

BLIND PERSON; CLINICAL PRACTICES; COMPLEX SYSTEMS; CUTTING EDGES; HIGHER-DEGREE; HUMAN BRAIN; IMPLANTABLE MEDICAL DEVICES; MANUFACTURING TECHNIQUES; MANUFACTURING TECHNOLOGIES; MEDICAL DEVICES; MICROSYSTEMS ENGINEERING; MOTOR CONTROL; NEURAL IMPLANTS; PERIPHERAL NERVES; PRECISION MECHANICS; RESEARCH APPROACH; TECHNICAL AIDS; THERAPY AND REHABILITATION;

EID: 77952430394     PISSN: 09467076     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00542-009-0988-x     Document Type: Conference Paper
Times cited : (66)

References (63)
  • 1
    • 0028857312 scopus 로고
    • The first 500 sacral anterior root stimulators: Implant failures and their repair
    • GS Brindley 1995 The first 500 sacral anterior root stimulators: implant failures and their repair Paraplegia 33 5 9
    • (1995) Paraplegia , vol.33 , pp. 5-9
    • Brindley, G.S.1
  • 2
    • 0033975843 scopus 로고    scopus 로고
    • Ceramic-based multisite microelectrodes for electrochemical recordings
    • DOI 10.1021/ac9907991
    • JJ Burmeister KA Moxon GA Gerhardt 2000 Ceramic-based multisite microelectrodes for electrochemical recordings Anal Chem 72 187 192 10.1021/ac9907991 (Pubitemid 30027755)
    • (2000) Analytical Chemistry , vol.72 , Issue.1 , pp. 187-192
    • Burmeister, J.J.1    Moxon, K.2    Gerhardt, G.A.3
  • 3
    • 0026205082 scopus 로고
    • A silicon-based, three-dimensional neural interface: Manufacturing processes for an intracortical electrode array
    • 10.1109/10.83588
    • PK Campbell KE Jones RJ Huber KW Horch RA Normann 1991 A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array IEEE Trans Bio-Med Eng 38 758 768 10.1109/10.83588
    • (1991) IEEE Trans Bio-Med Eng , vol.38 , pp. 758-768
    • Campbell, P.K.1    Jones, K.E.2    Huber, R.J.3    Horch, K.W.4    Normann, R.A.5
  • 4
    • 0037097145 scopus 로고    scopus 로고
    • Morphologic and functional evaluation of peripheral nerve fibers regenerated through polyimide sieve electrodes over long-term implantation
    • DOI 10.1002/jbm.10099
    • D Ceballos A Valero-Cabre E Valderrama M Schuettler T Stieglitz X Navarro 2002 Morphologic and functional evaluation of peripheral nerve fibres regenerated through polyimide sieve electrodes over long-term implantation J Biomed Mater Res 60 517 528 10.1002/jbm.10099 (Pubitemid 34492590)
    • (2002) Journal of Biomedical Materials Research , vol.60 , Issue.4 , pp. 517-528
    • Ceballos, D.1    Valero-Cabr, A.2    Valderrama, E.3    Schttler, M.4    Stieglitz, T.5    Navarro, X.6
  • 5
    • 67849112915 scopus 로고    scopus 로고
    • Micromanufactured electrodes for cortical field potentials recording: In vivo study
    • 10.1007/978-3-540-89208-3-570
    • J Cordeiro C Henle M Raab W Meier T Stieglitz A Schulze-Bonhage J Rickert 2008 Micromanufactured electrodes for cortical field potentials recording: in vivo study IFMBE Proc 22 2375 2378 10.1007/978-3-540-89208-3-570
    • (2008) IFMBE Proc , vol.22 , pp. 2375-2378
    • Cordeiro, J.1    Henle, C.2    Raab, M.3    Meier, W.4    Stieglitz, T.5    Schulze-Bonhage, A.6    Rickert, J.7
  • 6
    • 0023434288 scopus 로고
    • Twenty years of neurological prosthesis-making
    • 10.1016/0141-5425(87)90075-6
    • PEK Donaldson 1987 Twenty years of neurological prosthesis-making J Biomed Eng 9 291 298 10.1016/0141-5425(87)90075-6
    • (1987) J Biomed Eng , vol.9 , pp. 291-298
    • Donaldson, P.E.K.1
  • 7
    • 0024574737 scopus 로고
    • Encapsulating microelectronic implants in one-part silicone rubbers
    • DOI 10.1007/BF02442177
    • PEK Donaldson 1989 Encapsulating microelectronic implants in one-part silicone rubbers Med Biol Eng Comput 27 93 94 10.1007/BF02442177 (Pubitemid 19034791)
    • (1989) Medical and Biological Engineering and Computing , vol.27 , Issue.1 , pp. 93-94
    • Donaldson, P.E.K.1
  • 8
    • 0026008251 scopus 로고
    • Aspects of silicone rubber as an encapsulant for neurological prostheses-part1: Osmosis
    • 10.1007/BF02446293
    • PEK Donaldson 1991 Aspects of silicone rubber as an encapsulant for neurological prostheses-part1: osmosis Med Biol Eng Comput 29 34 39 10.1007/BF02446293
    • (1991) Med Biol Eng Comput , vol.29 , pp. 34-39
    • Donaldson, P.E.K.1
  • 9
    • 0028879612 scopus 로고
    • Aspects of silicone rubber as encapsulant for neurological prostheses-part3: Adhesion to mixed oxides
    • 10.1007/BF02510794
    • PEK Donaldson 1995 Aspects of silicone rubber as encapsulant for neurological prostheses-part3: adhesion to mixed oxides Med Biol Eng Comput 33 725 727 10.1007/BF02510794
    • (1995) Med Biol Eng Comput , vol.33 , pp. 725-727
    • Donaldson, P.E.K.1
  • 10
    • 0030143820 scopus 로고    scopus 로고
    • The essential role played by adhesion in the technology of neurological prostheses
    • DOI 10.1016/0143-7496(95)00031-3
    • PEK Donaldson 1996 The essential role played by adhesion in the technology of neurological prostheses Int J Adhes Adhes 16 105 107 10.1016/0143-7496(95)00031-3 (Pubitemid 126392704)
    • (1996) International Journal of Adhesion and Adhesives , vol.16 , Issue.2 , pp. 105-107
    • Donaldson, P.E.K.1
  • 11
    • 0031149911 scopus 로고    scopus 로고
    • Aspects of silicone rubber as encapsulant for neurological prostheses-part4: Two-part rubbers
    • 10.1007/BF02530051
    • PEK Donaldson 1997 Aspects of silicone rubber as encapsulant for neurological prostheses-part4: two-part rubbers Med Biol Eng Comput 35 283 286 10.1007/BF02530051
    • (1997) Med Biol Eng Comput , vol.35 , pp. 283-286
    • Donaldson, P.E.K.1
  • 12
    • 0029028674 scopus 로고
    • Aspects of silicone rubber as encapsulant for neurological prostheses-part2: Adhesion to binary oxides
    • 10.1007/BF02510501
    • PEK Donaldson BJ Aylett 1995 Aspects of silicone rubber as encapsulant for neurological prostheses-part2: adhesion to binary oxides Med Biol Eng Comput 33 285 292 10.1007/BF02510501
    • (1995) Med Biol Eng Comput , vol.33 , pp. 285-292
    • Donaldson, P.E.K.1    Aylett, B.J.2
  • 13
    • 0017556775 scopus 로고
    • Silicone-rubber adhesives as encapsulants for microelectronic implants; Effect of high electric fields and of tensile stress
    • 10.1007/BF02457937
    • PEK Donaldson E Sayer 1977 Silicone-rubber adhesives as encapsulants for microelectronic implants; effect of high electric fields and of tensile stress Med Biol Eng Comput 15 712 715 10.1007/BF02457937
    • (1977) Med Biol Eng Comput , vol.15 , pp. 712-715
    • Donaldson, P.E.K.1    Sayer, E.2
  • 14
    • 0001419040 scopus 로고
    • A new, general synthetic method for the preparation of linear poly-p-xylylenes
    • 10.1002/pol.1966.150041209
    • WF Gorham 1966 A new, general synthetic method for the preparation of linear poly-p-xylylenes J Polym Sci A1 4 3027 3039 10.1002/pol.1966.150041209
    • (1966) J Polym Sci A1 , vol.4 , pp. 3027-3039
    • Gorham, W.F.1
  • 15
    • 0036132495 scopus 로고    scopus 로고
    • Biostability of micro-photodiode arrays for subretinal implantation
    • DOI 10.1016/S0142-9612(01)00185-5, PII S0142961201001855
    • H Haemmerle K Kobuch K Kohler W Nisch H Sachs M Stelzle 2002 Biostability of micro-photodiode arrays for subretinal implantation Biomaterials 23 797 804 10.1016/S0142-9612(01)00185-5 (Pubitemid 33108954)
    • (2002) Biomaterials , vol.23 , Issue.3 , pp. 797-804
    • Hammerle, H.1    Kobuch, K.2    Kohler, K.3    Nisch, W.4    Sachs, H.5    Stelzle, M.6
  • 16
    • 69949183320 scopus 로고    scopus 로고
    • Deposition parameters determining insulation resistance and crystallinity of parylene C in neural implant encapsulation
    • 10.1007/978-3-540-89208-3-585
    • C Hassler T Stieglitz 2008 Deposition parameters determining insulation resistance and crystallinity of parylene C in neural implant encapsulation IFMBE Proc 22 2439 2442 10.1007/978-3-540-89208-3-585
    • (2008) IFMBE Proc , vol.22 , pp. 2439-2442
    • Hassler, C.1    Stieglitz, T.2
  • 17
    • 77949497612 scopus 로고    scopus 로고
    • Characterization of parylene C as an encapsulation material for neural prostheses
    • in press
    • Hassler C, von Metzen RP, Ruther P, Stieglitz T (2009) Characterization of parylene C as an encapsulation material for neural prostheses. J Biomed Mater Res B (in press)
    • (2009) J Biomed Mater Res B
    • Hassler, C.1    Von Metzen, R.P.2    Ruther, P.3    Stieglitz, T.4
  • 21
    • 34748924121 scopus 로고    scopus 로고
    • x:H thin films as an encapsulation material for integrated silicon based neural interface devices
    • DOI 10.1016/j.tsf.2007.04.050, PII S0040609007005974
    • J-M Hsu P Tathireddy L Rieth RA Normann F Solzbacher 2007 Characterization of a-SiCx:H thin films as an encapsulation material for integrated silicon based neural interface devices Thin Solid Films 516 34 41 10.1016/j.tsf.2007.04.050 (Pubitemid 47488462)
    • (2007) Thin Solid Films , vol.516 , Issue.1 , pp. 34-41
    • Hsu, J.-M.1    Tathireddy, P.2    Rieth, L.3    Normann, A.R.4    Solzbacher, F.5
  • 22
    • 60549100010 scopus 로고    scopus 로고
    • Encapsulation of an integrated neural interface device with parylene-C
    • 10.1109/TBME.2008.2002155
    • J-M Hsu L Rieth RA Normann P Tathireddy F Solzbacher 2009 Encapsulation of an integrated neural interface device with parylene-C IEEE Trans Biomed Eng 56 23 29 10.1109/TBME.2008.2002155
    • (2009) IEEE Trans Biomed Eng , vol.56 , pp. 23-29
    • Hsu, J.-M.1    Rieth, L.2    Normann, R.A.3    Tathireddy, P.4    Solzbacher, F.5
  • 26
    • 0030066135 scopus 로고    scopus 로고
    • Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
    • DOI 10.1016/0165-0270(95)00123-9
    • GE Loeb RA Peck 1996 Cuff electrodes for chronic stimulation and recording of peripheral nerve activity J Neurosci Methods 64 95 103 10.1016/0165-0270(95)00123-9 (Pubitemid 26069896)
    • (1996) Journal of Neuroscience Methods , vol.64 , Issue.1 , pp. 95-103
    • Loeb, G.E.1    Peck, R.A.2
  • 27
    • 0017368305 scopus 로고
    • Parylene as a chronically stable, reproducible microelectrode insulator
    • 10.1109/TBME.1977.326115
    • GE Loeb MJ Bak M Salcman EM Schmidt 1977 Parylene as a chronically stable, reproducible microelectrode insulator IEEE Trans Biomed Eng 24 121 128 10.1109/TBME.1977.326115
    • (1977) IEEE Trans Biomed Eng , vol.24 , pp. 121-128
    • Loeb, G.E.1    Bak, M.J.2    Salcman, M.3    Schmidt, E.M.4
  • 28
    • 0035422827 scopus 로고    scopus 로고
    • High density interconnects and flexible hybrid assemblies for active biomedical implants
    • DOI 10.1109/6040.938305, PII S1521332301060300
    • J-U Meyer T Stieglitz O Scholz W Haberer H Beutel 2001 High density interconnects and flexible hybrid assemblies for active biomedical implants IEEE Trans Adv Pack 24 366 374 10.1109/6040.938305 (Pubitemid 32780076)
    • (2001) IEEE Transactions on Advanced Packaging , vol.24 , Issue.3 , pp. 366-374
    • Meyer, J.-U.1    Stieglitz, T.2    Scholz, O.3    Haberer, W.4    Beutel, H.5
  • 30
    • 23844538849 scopus 로고    scopus 로고
    • An array of microactuated microelectrodes for monitoring single-neuronal activity in rodents
    • DOI 10.1109/TBME.2005.851478
    • J Muthuswamy M Okandan A Gilletti MS Baker T Jain 2005 An array of microactuated microelectrodes for monitoring single-neuronal activity in rodents IEEE Trans Biomed Eng 52 1470 1477 10.1109/TBME.2005.851478 (Pubitemid 41169541)
    • (2005) IEEE Transactions on Biomedical Engineering , vol.52 , Issue.8 , pp. 1470-1477
    • Muthuswamy, J.1    Okandan, M.2    Gilletti, A.3    Baker, M.S.4    Jain, T.5
  • 31
    • 0022863439 scopus 로고
    • An implantable multielectrode array with on-chip signal processing
    • 10.1109/JSSC.1986.1052646
    • K Najafi KD Wise 1986 An implantable multielectrode array with on-chip signal processing IEEE J Solid-State Circ 21 1035 1044 10.1109/JSSC.1986.1052646
    • (1986) IEEE J Solid-State Circ , vol.21 , pp. 1035-1044
    • Najafi, K.1    Wise, K.D.2
  • 34
    • 0034835683 scopus 로고    scopus 로고
    • Selective fascicular stimulation of the rat sciatic neve with multipolar polyimide cuff electrodes
    • X Navarro E Valderrama T Stieglitz M Schuettler 2001 Selective fascicular stimulation of the rat sciatic neve with multipolar polyimide cuff electrodes Restor Neurol Neurosci 18 9 21
    • (2001) Restor Neurol Neurosci , vol.18 , pp. 9-21
    • Navarro, X.1    Valderrama, E.2    Stieglitz, T.3    Schuettler, M.4
  • 38
    • 1442282994 scopus 로고    scopus 로고
    • Neuroprostheses to treat neurogenic bladder dysfunction: Current status and future perspectives
    • DOI 10.1007/s00381-003-0859-1
    • NJM Rijkhoff 2004 Neuroprostheses to treat neurogenic bladder dysfunction: current status and future perspectives Childs Nerv Syst 20 75 86 10.1007/s00381-003-0859-1 (Pubitemid 38268085)
    • (2004) Child's Nervous System , vol.20 , Issue.2 , pp. 75-86
    • Rijkhoff, N.J.M.1
  • 39
    • 33745699676 scopus 로고    scopus 로고
    • Scalable high lead-count parylene package for retinal prostheses
    • 10.1016/j.snb.2005.11.010
    • DC Rodger JD Weiland MS Humayun 2006 Scalable high lead-count parylene package for retinal prostheses Sens Actuators B Chem 117 107 114 10.1016/j.snb.2005.11.010
    • (2006) Sens Actuators B Chem , vol.117 , pp. 107-114
    • Rodger, D.C.1    Weiland, J.D.2    Humayun, M.S.3
  • 43
    • 77952420266 scopus 로고    scopus 로고
    • Mechanische Lanzeitstabilität von Polyimid als Substratmaterial für mikrotechnisch gefertigte Implantate
    • Rubehn B, Stieglitz T (2007) Mechanische Lanzeitstabilität von Polyimid als Substratmaterial für mikrotechnisch gefertigte Implantate. Biomed Technol, vol 52(Suppl), 2 pp
    • (2007) Biomed Technol , vol.52 , Issue.SUPPL.
    • Rubehn, B.1    Stieglitz, T.2
  • 45
    • 2442555963 scopus 로고    scopus 로고
    • Neuroprothetik der Oberen Extremitaet-Klinische Einsatzmoeglichkeiten bei Querschnittslaehmung und Perspektiven fuer die Zukunft
    • 10.1515/BMT.2004.019
    • R Rupp HJ Gerner 2004 Neuroprothetik der Oberen Extremitaet-Klinische Einsatzmoeglichkeiten bei Querschnittslaehmung und Perspektiven fuer die Zukunft Biomed Technol 49 93 98 10.1515/BMT.2004.019
    • (2004) Biomed Technol , vol.49 , pp. 93-98
    • Rupp, R.1    Gerner, H.J.2
  • 46
    • 22044438514 scopus 로고    scopus 로고
    • Fabrication of implantable microelectrode arrays by laser cutting of silicone rubber and platinum foil
    • DOI 10.1088/1741-2560/2/1/013
    • M Schuettler S Stiess GJ Suaning 2005 Fabrication of implantable microelectrode arrays by laser cutting of silicone rubber and platinum foil J Neural Eng 2 S121 S128 10.1088/1741-2560/2/1/013 (Pubitemid 41238015)
    • (2005) Journal of Neural Engineering , vol.2 , Issue.1
    • Schuettler, M.1    Stiess, S.2    King, B.V.3    Suaning, G.J.4
  • 49
    • 6344258657 scopus 로고    scopus 로고
    • Considerations on surface and structural biocompatibility as prerequisite for long-term stability of neural prostheses
    • DOI 10.1166/jnn.2004.075
    • T Stieglitz 2004 Considerations on surface and structural biocompatibility as prerequisite for long-term stability of neural prostheses J Nanosci Nanotechnol 4 496 503 10.1166/jnn.2004.075 (Pubitemid 39387401)
    • (2004) Journal of Nanoscience and Nanotechnology , vol.4 , Issue.5 , pp. 496-503
    • Stieglitz, T.1
  • 50
    • 33745076897 scopus 로고    scopus 로고
    • Neural implants in clinical practice
    • G.A. Urban (eds). Dordrecht Springer. 10.1007/978-0-387-28732-4-3
    • Stieglitz T, Meyer J-U (2006a) Neural implants in clinical practice. In: Urban GA (ed) BIOMEMS. Dordrecht, Springer, pp 41-70
    • (2006) BIOMEMS , pp. 41-70
    • Stieglitz, T.1    Meyer, J.-U.2
  • 51
    • 33745108264 scopus 로고    scopus 로고
    • Biomedical micro-devices for neural implants
    • G.A. Urban (eds). Dordrecht Springer. 10.1007/978-0-387-28732-4-4
    • Stieglitz T, Meyer J-U (2006b) Biomedical micro-devices for neural implants. In: Urban GA (ed) BIOMEMS. Dordrecht, Springer, pp 71-137
    • (2006) BIOMEMS , pp. 71-137
    • Stieglitz, T.1    Meyer, J.-U.2
  • 52
    • 0031144384 scopus 로고    scopus 로고
    • A flexible, light-weighted multichannel sieve electrode with integrated cables for interfacing regenerating peripheral nerves
    • 10.1016/S0924-4247(97)01494-5
    • T Stieglitz H Beutel J-U Meyer 1997 A flexible, light-weighted multichannel sieve electrode with integrated cables for interfacing regenerating peripheral nerves Sens Actuators A Phys 60 240 243 10.1016/S0924-4247(97)01494- 5
    • (1997) Sens Actuators A Phys , vol.60 , pp. 240-243
    • Stieglitz, T.1    Beutel, H.2    Meyer, J.-U.3
  • 53
    • 0001574753 scopus 로고    scopus 로고
    • Micromachined, polyimide-based devices for flexible neural interfaces
    • 10.1023/A:1009955222114
    • T Stieglitz H Beutel M Schuettler J-U Meyer 2000 Micromachined, polyimide-based devices for flexible neural interfaces Biomed Microdev 2 283 294 10.1023/A:1009955222114
    • (2000) Biomed Microdev , vol.2 , pp. 283-294
    • Stieglitz, T.1    Beutel, H.2    Schuettler, M.3    Meyer, J.-U.4
  • 54
    • 69949181360 scopus 로고    scopus 로고
    • Ansaetze zu einer Biokompatiblen Aufbau-und Verbindungstechnik fuer Biomedizinische Mikrosysteme
    • 10.1515/bmte.2003.48.s1.378
    • T Stieglitz J Uhlemann KP Koch E Meusel 2003 Ansaetze zu einer Biokompatiblen Aufbau-und Verbindungstechnik fuer Biomedizinische Mikrosysteme Biomed Technol 48 Suppl 1 378 379 10.1515/bmte.2003.48.s1.378
    • (2003) Biomed Technol , vol.48 , Issue.SUPPL 1 , pp. 378-379
    • Stieglitz, T.1    Uhlemann, J.2    Koch, K.P.3    Meusel, E.4
  • 60
    • 0014816457 scopus 로고
    • An integrated-circuit approach to extracellular microelectrodes
    • 10.1109/TBME.1970.4502738
    • KD Wise JB Angel A Starr 1970 An integrated-circuit approach to extracellular microelectrodes IEEE Trans Biomed Eng 17 238 247 10.1109/TBME.1970.4502738
    • (1970) IEEE Trans Biomed Eng , vol.17 , pp. 238-247
    • Wise, K.D.1    Angel, J.B.2    Starr, A.3
  • 61
    • 2442708539 scopus 로고    scopus 로고
    • Wireless implantable microsystems: High-density electronic interfaces to the nervous system
    • DOI 10.1109/JPROC.2003.820544, Biomedical Applications for Mems and Microfluidics
    • KD Wise DJ Anderson JF Hetke DR Kipke K Najafi 2004 Wireless implantable microsystems: high-density electronic interfaces to the nervous system Proc IEEE 92 76 96 10.1109/JPROC.2003.820544 (Pubitemid 40890773)
    • (2004) Proceedings of the IEEE , vol.92 , Issue.1 , pp. 76-97
    • Wise, K.D.1    Anderson, D.J.2    Hetke, J.F.3    Kipke, D.R.4    Najafi, K.5
  • 62
    • 58149113572 scopus 로고    scopus 로고
    • Assessing the effects of sterilization methods on parylene coatings
    • L Wolgemuth 2002 Assessing the effects of sterilization methods on parylene coatings Med Device Diagn Ind 23 46 48
    • (2002) Med Device Diagn Ind , vol.23 , pp. 46-48
    • Wolgemuth, L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.