-
1
-
-
0001494849
-
Regeneration in the mammalian peripheral nervous system
-
Guth L: Regeneration in the mammalian peripheral nervous system. Physiol. Rev. 1956; 36:441-478.
-
(1956)
Physiol. Rev.
, vol.36
, pp. 441-478
-
-
Guth, L.1
-
2
-
-
0018381824
-
Nerve conduction, tactile sensibility, and the electromyogram after suture or compression of peripheral nerve: A longitudinal study in man
-
Buchthal F, Kühl V: Nerve conduction, tactile sensibility, and the electromyogram after suture or compression of peripheral nerve: a longitudinal study in man. J. Neurol. Neurosurg. Psychiat. 1979; 42:436-451.
-
(1979)
J. Neurol. Neurosurg. Psychiat.
, vol.42
, pp. 436-451
-
-
Buchthal, F.1
Kühl, V.2
-
3
-
-
0023764815
-
Assessment of nerve regeneration and adaptation after median nerve reconnection and digital neurovascular Hap transfer
-
Dyck PJ, Lambert EH, Wood MB, Linscheid RL: Assessment of nerve regeneration and adaptation after median nerve reconnection and digital neurovascular Hap transfer. Neurology 1988; 38:1586-1591.
-
(1988)
Neurology
, vol.38
, pp. 1586-1591
-
-
Dyck, P.J.1
Lambert, E.H.2
Wood, M.B.3
Linscheid, R.L.4
-
4
-
-
0028171974
-
Comparison of regenerative and reinnervating capabilities of different functional types of nerve fibers
-
Navarro X, Verdú E, Butí M: Comparison of regenerative and reinnervating capabilities of different functional types of nerve fibers. Exp. Neurol. 1994; 129: 217-224.
-
(1994)
Exp. Neurol.
, vol.129
, pp. 217-224
-
-
Navarro, X.1
Verdú, E.2
Butí, M.3
-
5
-
-
0024426206
-
Focal nerve injury: Guidance factors during axonal regeneration
-
Thomas PK: Focal nerve injury: guidance factors during axonal regeneration. Muscle Nerve 1989; 12:796-802.
-
(1989)
Muscle Nerve
, vol.12
, pp. 796-802
-
-
Thomas, P.K.1
-
6
-
-
0026641194
-
Effects of different methods of peripheral nerve repair on the number and distribution of muscle afferent neurons in rat dorsal root ganglion
-
Myles LM, Gilmour JA, Glasby MA: Effects of different methods of peripheral nerve repair on the number and distribution of muscle afferent neurons in rat dorsal root ganglion. J. Neurosurg. 1992; 77:457-462.
-
(1992)
J. Neurosurg.
, vol.77
, pp. 457-462
-
-
Myles, L.M.1
Gilmour, J.A.2
Glasby, M.A.3
-
7
-
-
0026671465
-
Directional specificity of regenerating primary sensory neurons after peripheral nerve crush or transection and epineurial suture. A sequential double-labeling study in the rat
-
Molander C, Aldskogius H: Directional specificity of regenerating primary sensory neurons after peripheral nerve crush or transection and epineurial suture. A sequential double-labeling study in the rat. Restor. Neurol. Neurosci. 1992; 4:339-344.
-
(1992)
Restor. Neurol. Neurosci.
, vol.4
, pp. 339-344
-
-
Molander, C.1
Aldskogius, H.2
-
8
-
-
0003071052
-
Implantable monolithic wafer recording electrodes for neurophysiology
-
(Phillips MI, ed). Springfield, IL: Charles C Thomas
-
Llinás R, Nicholson C, Johnson K: Implantable monolithic wafer recording electrodes for neurophysiology. In: Brain Unit Activity during Behaviour (Phillips MI, ed). Springfield, IL: Charles C Thomas, 1973; 105-110.
-
(1973)
Brain Unit Activity during Behaviour
, pp. 105-110
-
-
Llinás, R.1
Nicholson, C.2
Johnson, K.3
-
10
-
-
0022559394
-
A peripheral nerve information transducer for amputees: Long-term multichannel recordings from rabbit peripheral nerves
-
Edell DJ: A peripheral nerve information transducer for amputees: Long-term multichannel recordings from rabbit peripheral nerves. IEEE Trans. Biomed. Engin. 1986; 33:203-214.
-
(1986)
IEEE Trans. Biomed. Engin.
, vol.33
, pp. 203-214
-
-
Edell, D.J.1
-
11
-
-
0026926772
-
Regeneration microelectrode array for peripheral nerve recording and stimulation
-
Kovacs GTA, Storment CW, Rosen JM: Regeneration microelectrode array for peripheral nerve recording and stimulation. IEEE Trans. Biomed. Engin. 1992; 39:893-902.
-
(1992)
IEEE Trans. Biomed. Engin.
, vol.39
, pp. 893-902
-
-
Kovacs, G.T.A.1
Storment, C.W.2
Rosen, J.M.3
-
12
-
-
84947421346
-
Regenerative-type neural interface
-
(Mira J, Sandoval F, eds). Berlin: Springer
-
Valderrama E, Villa R, Cabruja E, Garrido P, Navarro X, Butí M, Calvet S: Regenerative-type neural interface. In: From Natural to Artificial Neural Computation (Mira J, Sandoval F, eds). Berlin: Springer, 1995; 114-120.
-
(1995)
From Natural to Artificial Neural Computation
, pp. 114-120
-
-
Valderrama, E.1
Villa, R.2
Cabruja, E.3
Garrido, P.4
Navarro, X.5
Butí, M.6
Calvet, S.7
-
13
-
-
0025203709
-
Preliminary experiments in nerve regeneration through laser-drilled holes in silicon chips
-
Rosen JM, Grosser M, Hentz VR: Preliminary experiments in nerve regeneration through laser-drilled holes in silicon chips. Restor. Neurol. Neurosci. 1990; 2:89-102.
-
(1990)
Restor. Neurol. Neurosci.
, vol.2
, pp. 89-102
-
-
Rosen, J.M.1
Grosser, M.2
Hentz, V.R.3
-
14
-
-
0028450429
-
Siliconsubstrate microelectrode array for parallel recording of neural activity in peripheral and cranial nerves
-
Kovacs GTA, Storment CW, Halks-Miller M, Belczynski CR, Della Santina CC, Lewis ER, Maluf NI: Siliconsubstrate microelectrode array for parallel recording of neural activity in peripheral and cranial nerves. IEEE Trans. Biomed. Engin. 1994; 41:567-577.
-
(1994)
IEEE Trans. Biomed. Engin.
, vol.41
, pp. 567-577
-
-
Kovacs, G.T.A.1
Storment, C.W.2
Halks-Miller, M.3
Belczynski, C.R.4
Della Santina, C.C.5
Lewis, E.R.6
Maluf, N.I.7
-
15
-
-
0029890914
-
Peripheral nerve regeneration through microelectrode arrays based on silicon technology
-
Navarro X, Calvet S, Butí M, Gómez N, Cabruja E, Garrido P, Villa R, Valderrama E: Peripheral nerve regeneration through microelectrode arrays based on silicon technology. Restor. Neurol. Neurosci. 1996; 9:151-160.
-
(1996)
Restor. Neurol. Neurosci.
, vol.9
, pp. 151-160
-
-
Navarro, X.1
Calvet, S.2
Butí, M.3
Gómez, N.4
Cabruja, E.5
Garrido, P.6
Villa, R.7
Valderrama, E.8
-
16
-
-
0030311829
-
Interfacing regenerating peripheral nerves with a micromachined polyimide sieve electrode
-
Amsterdam, paper 417 (on CD-ROM)
-
Stieglitz T, Navarro X, Calvet S, Blau C, Meyer J-U: Interfacing regenerating peripheral nerves with a micromachined polyimide sieve electrode. Proceedings of the 18th Annual Int. Conference IEEE Engineering in Medicine and Biology Society, Amsterdam, 1996, paper 417 (on CD-ROM).
-
(1996)
Proceedings of the 18th Annual Int. Conference IEEE Engineering in Medicine and Biology Society
-
-
Stieglitz, T.1
Navarro, X.2
Calvet, S.3
Blau, C.4
Meyer, J.-U.5
-
17
-
-
0031144384
-
A flexible, light-weight multichannel sieve electrode with integrated cables for interfacing regenerating peripheral nerves
-
Stieglitz T, Beutel H, Meyer J-U: A flexible, light-weight multichannel sieve electrode with integrated cables for interfacing regenerating peripheral nerves. Sensor Actuators A 1997; 60:240-243.
-
(1997)
Sensor Actuators A
, vol.60
, pp. 240-243
-
-
Stieglitz, T.1
Beutel, H.2
Meyer, J.-U.3
-
18
-
-
0028354642
-
Autotomy prevention by amitriptyline after nerve section in different strains of mice
-
Navarro X, Verdú E, Butí M: Autotomy prevention by amitriptyline after nerve section in different strains of mice. Restor. Neurol. Neurosci. 1994; 6:151-157.
-
(1994)
Restor. Neurol. Neurosci.
, vol.6
, pp. 151-157
-
-
Navarro, X.1
Verdú, E.2
Butí, M.3
-
20
-
-
0031294053
-
Development of flexible Stimulation devices for a retina implant system
-
Chicago, (in press)
-
Stieglitz T, Beutel H, Keller R, Blau C, Meyer J-U: Development of flexible Stimulation devices for a retina implant system. Proceedings of the 19th Annual Int. Conference IEEE Engineering in Medicine and Biology Society, Chicago, 1997 (in press).
-
(1997)
Proceedings of the 19th Annual Int. Conference IEEE Engineering in Medicine and Biology Society
-
-
Stieglitz, T.1
Beutel, H.2
Keller, R.3
Blau, C.4
Meyer, J.-U.5
-
21
-
-
0015962791
-
Regeneration electrode units: Implants for recording from single peripheral nerve fibers in freely moving animals
-
Mannard A, Stein RB, Charles D: Regeneration electrode units: implants for recording from single peripheral nerve fibers in freely moving animals. Science 1974; 183:547-549.
-
(1974)
Science
, vol.183
, pp. 547-549
-
-
Mannard, A.1
Stein, R.B.2
Charles, D.3
-
22
-
-
0031032712
-
Rat sciatic nerve regeneration through a micromachined silicon chip
-
Zhao Q, Drott J, Laurell T, Wallman L, Lindström K, Bjursten LM, Lundborg G, Montelius L, Danielsen N: Rat sciatic nerve regeneration through a micromachined silicon chip. Biomaterials 1997; 18:75-80.
-
(1997)
Biomaterials
, vol.18
, pp. 75-80
-
-
Zhao, Q.1
Drott, J.2
Laurell, T.3
Wallman, L.4
Lindström, K.5
Bjursten, L.M.6
Lundborg, G.7
Montelius, L.8
Danielsen, N.9
-
23
-
-
0030937434
-
Multi-unit recording from regenerated bullfrog eighth nerve using implantable silicon-substrate microelectrodes
-
Della Santina CC, Kovacs GTA, Lewis ER: Multi-unit recording from regenerated bullfrog eighth nerve using implantable silicon-substrate microelectrodes. J. Neurosci. Meth. 1997; 72:71-86.
-
(1997)
J. Neurosci. Meth.
, vol.72
, pp. 71-86
-
-
Della Santina, C.C.1
Kovacs, G.T.A.2
Lewis, E.R.3
-
24
-
-
0026471648
-
Functional regeneration of glossopharyngeal nerve through micromachined sieve electrode arrays
-
Bradley RM, Smoke RH, Akin T, Najafi K: Functional regeneration of glossopharyngeal nerve through micromachined sieve electrode arrays. Brain Res. 1992; 594:84-90.
-
(1992)
Brain Res.
, vol.594
, pp. 84-90
-
-
Bradley, R.M.1
Smoke, R.H.2
Akin, T.3
Najafi, K.4
-
25
-
-
0027627674
-
Polyimides as biomaterials: Preliminary biocompatibility testing
-
Richardson RR, Miller JA, Reichert WM: Polyimides as biomaterials: preliminary biocompatibility testing. Biomaterials 1993; 14:627-635.
-
(1993)
Biomaterials
, vol.14
, pp. 627-635
-
-
Richardson, R.R.1
Miller, J.A.2
Reichert, W.M.3
-
26
-
-
0030066135
-
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
-
Loeb GE, Peck RA: Cuff electrodes for chronic stimulation and recording of peripheral nerve activity. J. Neurosci. Meth. 1996; 64:95-103.
-
(1996)
J. Neurosci. Meth.
, vol.64
, pp. 95-103
-
-
Loeb, G.E.1
Peck, R.A.2
-
27
-
-
0343852697
-
A flexible perforated microelectrode array probe for action potential recording in nerve and muscle tissues
-
Gonzalez C, Rodríguez M: A flexible perforated microelectrode array probe for action potential recording in nerve and muscle tissues. J. Neurosci. Meth. 1997; 72:189-195.
-
(1997)
J. Neurosci. Meth.
, vol.72
, pp. 189-195
-
-
Gonzalez, C.1
Rodríguez, M.2
-
28
-
-
0018566312
-
Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves
-
Vallbo A, Hagbarth K, Torebjörk H, Wallin G: Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves. Physiol. Rev. 1979; 59:919-957.
-
(1979)
Physiol. Rev.
, vol.59
, pp. 919-957
-
-
Vallbo, A.1
Hagbarth, K.2
Torebjörk, H.3
Wallin, G.4
-
29
-
-
0017462744
-
Analysis and microelectrode design of tubular electrode arrays intended for chronic, multiple single-unit recording from captured nerve fibres
-
Loeb GE, Marks WB, Beatty PG: Analysis and microelectrode design of tubular electrode arrays intended for chronic, multiple single-unit recording from captured nerve fibres. Med. Biol. Eng. Comput. 1977; 15:195-201.
-
(1977)
Med. Biol. Eng. Comput.
, vol.15
, pp. 195-201
-
-
Loeb, G.E.1
Marks, W.B.2
Beatty, P.G.3
-
30
-
-
0017076984
-
Action currents, internodal potentials, and extracellular records of myelinated mammalian nerve fibers derived from node potentials
-
Mark WB, Loeb GE: Action currents, internodal potentials, and extracellular records of myelinated mammalian nerve fibers derived from node potentials. Biophys. J. 1976;16:655-668.
-
(1976)
Biophys. J.
, vol.16
, pp. 655-668
-
-
Mark, W.B.1
Loeb, G.E.2
|