메뉴 건너뛰기




Volumn 248, Issue 4, 2010, Pages 585-591

The influence of refractive errors on IOP measurement by rebound tonometry (ICare) and Goldmann applanation tonometry

Author keywords

Goldmann applanation tonometer; ICare; Intraocular pressure; Rebound tonometer; Refractive errors

Indexed keywords

ADULT; AGED; ARTICLE; ASTIGMATISM; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORNEA THICKNESS; CORRELATION FUNCTION; ECHOGRAPHY; EMMETROPIA; FEMALE; HUMAN; HYPERMETROPIA; INTERMETHOD COMPARISON; INTRAOCULAR PRESSURE; MAJOR CLINICAL STUDY; MALE; MYOPIA; OBSERVER VARIATION; OCULOPLETHYSMOGRAPHY; PRIORITY JOURNAL; REFRACTION ERROR; REFRACTOMETER; TONOMETER;

EID: 77949269541     PISSN: 0721832X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00417-009-1176-5     Document Type: Article
Times cited : (29)

References (25)
  • 1
    • 0028273231 scopus 로고
    • Reliability of intraocular pressure measurement with the Goldmann applanation tonometer in epidemiological studies
    • 10.1007/BF00176782 1:STN:280:DyaK2c3ksV2ltQ%3D%3D 8188062
    • I Dielemans JR Vingerling A Hofman DE Grobbee PT de Jong 1994 Reliability of intraocular pressure measurement with the Goldmann applanation tonometer in epidemiological studies Graefes Arch Clin Exp Ophthalmol 232 141 144 10.1007/BF00176782 1:STN:280:DyaK2c3ksV2ltQ%3D%3D 8188062
    • (1994) Graefes Arch Clin Exp Ophthalmol , vol.232 , pp. 141-144
    • Dielemans, I.1    Vingerling, J.R.2    Hofman, A.3    Grobbee, D.E.4    De Jong, P.T.5
  • 2
    • 4344659799 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry with Goldmann applanation tonometry
    • DOI 10.1167/iovs.04-0018
    • C Kaufmann LM Bachmann MA Thiel 2004 Comparison of dynamic contour tonometry with Goldmann applanation tonometry Invest Ophthalmol Vis Sci 45 3118 3121 10.1167/iovs.04-0018 15326129 (Pubitemid 39121844)
    • (2004) Investigative Ophthalmology and Visual Science , vol.45 , Issue.9 , pp. 3118-3121
    • Kaufmann, C.1    Bachmann, L.M.2    Thiel, M.A.3
  • 3
    • 33646901276 scopus 로고    scopus 로고
    • Measuring intraocular pressure-adjustments for corneal thickness and new technologies
    • DOI 10.1097/01.icu.0000193093.05927.a1, PII 0005573520060400000002
    • LW Herndon 2006 Measuring intraocular pressure-adjustments for corneal thickness and new technologies Curr Opin Ophthalmol 17 115 119 10.1097/01.icu.0000193093.05927.a1 16552245 (Pubitemid 43790806)
    • (2006) Current Opinion in Ophthalmology , vol.17 , Issue.2 , pp. 115-119
    • Herndon, L.W.1
  • 4
    • 40049104749 scopus 로고    scopus 로고
    • New ways to measure intraocular pressure
    • DOI 10.1097/ICU.0b013e3282f391ae, PII 0005573520080300000008
    • MK ElMallah SG Asrani 2008 New ways to measure intraocular pressure Curr Opin Ophthalmol 19 122 126 10.1097/ICU.0b013e3282f391ae 18301285 (Pubitemid 351322814)
    • (2008) Current Opinion in Ophthalmology , vol.19 , Issue.2 , pp. 122-126
    • ElMallah, M.K.1    Asrani, S.G.2
  • 5
    • 0034115306 scopus 로고    scopus 로고
    • A new induction-based impact method for measuring intraocular pressure
    • DOI 10.1034/j.1600-0420.2000.078002142.x
    • AI Kontiola 2000 A new induction-based impact method for measuring intraocular pressure Acta Ophthalmol Scand 78 142 145 10.1034/j.1600-0420.2000. 078002142.x 1:STN:280:DC%2BD3c3lt1aiuw%3D%3D 10794245 (Pubitemid 30201419)
    • (2000) Acta Ophthalmologica Scandinavica , vol.78 , Issue.2 , pp. 142-145
    • Kontiola, A.I.1
  • 6
    • 0035704347 scopus 로고    scopus 로고
    • The induction/impact tonometer: A new instrument to measure intraocular pressure in the rat
    • DOI 10.1006/exer.2001.1088
    • AI Kontiola D Goldblum T Mittag J Danias 2001 The induction/impact tonometer: a new instrument to measure intraocular pressure in rat Exp Eye Res 73 781 785 10.1006/exer.2001.1088 1:CAS:528:DC%2BD38XhsVCitLo%3D 11846509 (Pubitemid 34112104)
    • (2001) Experimental Eye Research , vol.73 , Issue.6 , pp. 781-785
    • Kontiola, A.I.1    Goldblum, D.2    Mittag, T.3    Danias, J.4
  • 7
    • 28244452880 scopus 로고    scopus 로고
    • Comparison of the ICare® rebound tonometer with the Goldmann tonometer in a normal population
    • DOI 10.1111/j.1475-1313.2005.00327.x
    • P Fernandes JA Diaz-Rey A Queiros JM Gonzalez-Meijome J Jorge 2005 Comparison of the ICare(R) rebound tonometer with the Goldmann tonometer in a normal population Ophthalmic Physiol Opt 25 436 440 10.1111/j.1475-1313.2005. 00327.x 1:STN:280:DC%2BD2Mvjs1Okug%3D%3D 16101950 (Pubitemid 41710978)
    • (2005) Ophthalmic and Physiological Optics , vol.25 , Issue.5 , pp. 436-440
    • Fernandes, P.1    Diaz-Rey, J.A.2    Queiros, A.3    Gonzalez-Meijome, J.M.4    Jorge, J.5
  • 8
    • 28244471011 scopus 로고    scopus 로고
    • Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry
    • DOI 10.1111/j.1475-1313.2005.00318.x
    • LH van der Jagt NM Jansonius 2005 Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry Ophthalmic Physiol Opt 25 429 435 10.1111/j.1475-1313. 2005.00318.x 16101949 (Pubitemid 41710977)
    • (2005) Ophthalmic and Physiological Optics , vol.25 , Issue.5 , pp. 429-435
    • Van Der Jagt, L.H.1    Jansonius, N.M.2
  • 10
    • 33745667304 scopus 로고    scopus 로고
    • Comparison of rebound tonometry with Goldmann applanation tonometry and correlation with central corneal thickness
    • DOI 10.1136/bjo.2005.089870
    • ME Iliev D Goldblum K Katsoulis C Amstutz B Frueh 2006 Comparison of rebound tonometry with Goldmann applanation tonometry and correlation with central corneal thickness Br J Ophthalmol 90 833 835 10.1136/bjo.2005.089870 1:STN:280:DC%2BD28zms1Witg%3D%3D 16672330 (Pubitemid 43973990)
    • (2006) British Journal of Ophthalmology , vol.90 , Issue.7 , pp. 833-835
    • Iliev, M.E.1    Goldblum, D.2    Katsoulis, K.3    Amstutz, C.4    Frueh, B.5
  • 11
    • 33845951494 scopus 로고    scopus 로고
    • Clinical evaluation of the dynamic rebound tonometer Icare
    • 10.1016/S0181-5512(06)73907-9 1:STN:280:DC%2BD2s%2Fhs1Sisg%3D%3D 17211320
    • M Detry-Morel J Jamart MB Detry S Pourjavan L Charlier B Dethinne L Huge A Ledoux 2006 Clinical evaluation of the dynamic rebound tonometer Icare J Fr Ophtalmol 29 1119 1127 10.1016/S0181-5512(06)73907-9 1:STN:280: DC%2BD2s%2Fhs1Sisg%3D%3D 17211320
    • (2006) J Fr Ophtalmol , vol.29 , pp. 1119-1127
    • Detry-Morel, M.1    Jamart, J.2    Detry, M.B.3    Pourjavan, S.4    Charlier, L.5    Dethinne, B.6    Huge, L.7    Ledoux, A.8
  • 12
    • 33645464184 scopus 로고    scopus 로고
    • Clinical evaluation of rebound tonometer
    • 10.1111/j.1600-0420.2005.00610.x 16637838
    • LN Davies H Bartlett EA Mallen JS Wolffsohn 2006 Clinical evaluation of rebound tonometer Acta Ophthalmol Scand 84 206 209 10.1111/j.1600-0420.2005. 00610.x 16637838
    • (2006) Acta Ophthalmol Scand , vol.84 , pp. 206-209
    • Davies, L.N.1    Bartlett, H.2    Mallen, E.A.3    Wolffsohn, J.S.4
  • 13
    • 33745282996 scopus 로고    scopus 로고
    • Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients
    • DOI 10.1097/01.ijg.0000212208.87523.66, PII 0006119820060600000006
    • P Brusini ML Salvetat M Zeppieri C Tosoni L Parisi 2006 Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients J Glaucoma 15 213 217 10.1097/01.ijg.0000212208.87523.66 16778643 (Pubitemid 43916813)
    • (2006) Journal of Glaucoma , vol.15 , Issue.3 , pp. 213-217
    • Brusini, P.1    Salvetat, M.L.2    Zeppieri, M.3    Tosoni, C.4    Parisi, L.5
  • 15
    • 33746277068 scopus 로고    scopus 로고
    • Agreement of rebound tonometer in measuring intraocular pressure with three types of applanation tonometers
    • DOI 10.1016/j.ajo.2006.02.035, PII S0002939406003308
    • M Nakamura U Darhad Y Tatsumi M Fujioka A Kusuhara H Maeda A Negi 2006 Agreement of rebound tonometer in measuring intraocular pressure with three types of applanation tonometers Am J Ophthalmol 142 332 334 10.1016/j.ajo.2006. 02.035 16876523 (Pubitemid 44107273)
    • (2006) American Journal of Ophthalmology , vol.142 , Issue.2 , pp. 332-334
    • Nakamura, M.1    Darhad, U.2    Tatsumi, Y.3    Fujioka, M.4    Kusuhara, A.5    Maeda, H.6    Negi, A.7
  • 16
    • 34548410983 scopus 로고    scopus 로고
    • Rebound tonometry in a clinical setting. Comparison with applanation tonometry
    • 17516263
    • C López-Caballero I Contreras FJ Muñoz-Negrete 2007 Rebound tonometry in a clinical setting. Comparison with applanation tonometry Arch Soc Esp Oftalmol 82 273 278 17516263
    • (2007) Arch Soc Esp Oftalmol , vol.82 , pp. 273-278
    • López-Caballero, C.1    Contreras, I.2    Muñoz-Negrete, F.J.3
  • 17
    • 34548049291 scopus 로고    scopus 로고
    • Evaluation of the impedance tonometers TGDc-01 and iCare according to the international ocular tonometer standards ISO 8612
    • DOI 10.1007/s00417-006-0483-3
    • PC Ruokonen T Schwenteck J Draeger 2007 Evaluation of the impedance tonometers TGDc-01 and iCare according to the international ocular tonometer standards ISO 8612 Graefes Arch Clin Exp Ophthalmol 245 1259 1265 10.1007/s00417-006-0483-3 17318572 (Pubitemid 47278661)
    • (2007) Graefe's Archive for Clinical and Experimental Ophthalmology , vol.245 , Issue.9 , pp. 1259-1265
    • Ruokonen, P.C.1    Schwenteck, T.2    Draeger, J.3
  • 18
    • 43249124722 scopus 로고    scopus 로고
    • Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer over a wide IOP range
    • 10.1007/s00417-007-0758-3 1:STN:280:DC%2BD1c3psVyhsg%3D%3D 18196259
    • S Munkwitz A Elkarmouty EM Hoffmann N Pfeiffer H Thieme 2008 Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer over a wide IOP range Graefes Arch Clin Exp Ophthalmol 246 875 879 10.1007/s00417-007- 0758-3 1:STN:280:DC%2BD1c3psVyhsg%3D%3D 18196259
    • (2008) Graefes Arch Clin Exp Ophthalmol , vol.246 , pp. 875-879
    • Munkwitz, S.1    Elkarmouty, A.2    Hoffmann, E.M.3    Pfeiffer, N.4    Thieme, H.5
  • 19
    • 1142299596 scopus 로고    scopus 로고
    • Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic
    • DOI 10.1007/s00417-003-0671-3
    • A Kontiola P Puska 2004 Measuring intraocular pressure with the Pulsair 3000 and rebound tonometers in elderly patients without an anesthetic Graefes Arch Clin Exp Ophthalmol 242 3 7 10.1007/s00417-003-0671-3 14634828 (Pubitemid 38208277)
    • (2004) Graefe's Archive for Clinical and Experimental Ophthalmology , vol.242 , Issue.1 , pp. 3-7
    • Kontiola, A.1    Puska, P.2
  • 21
    • 37349001245 scopus 로고    scopus 로고
    • The influence of corneal croperties on rebound tonometry
    • DOI 10.1016/j.ophtha.2007.03.061, PII S0161642007003442
    • WS Chui A Lam D Chen R Chiu 2008 The Influence of corneal croperties on rebound tonometry Ophthalmology 115 80 84 10.1016/j.ophtha.2007.03.061 17573114 (Pubitemid 350309417)
    • (2008) Ophthalmology , vol.115 , Issue.1 , pp. 80-84
    • Chui, W.-s.1    Lam, A.2    Chen, D.3    Chiu, R.4
  • 22
    • 40049104046 scopus 로고    scopus 로고
    • Clinical comparison of the Icare tonometer and goldmann applanation tonometry
    • DOI 10.1097/IJG.0b013e318133fb32, PII 0006119820080100000010
    • N Pakrou T Gray R Mills J Landers J Craig 2008 Clinical comparison of the Icare tonometer and Goldmann applanation tonometry J Glaucoma 17 43 47 10.1097/IJG.0b013e318133fb32 18303384 (Pubitemid 351321476)
    • (2008) Journal of Glaucoma , vol.17 , Issue.1 , pp. 43-47
    • Pakrou, N.1    Gray, T.2    Mills, R.3    Landers, J.4    Craig, J.5
  • 23
    • 34248347895 scopus 로고    scopus 로고
    • Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer
    • DOI 10.1167/iovs.06-0557
    • A Kotecha A Elsheikh CR Roberts H Zhu DF Garway-Heath 2006 Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer Invest Ophthalmol Vis Sci 47 5337 5347 10.1167/iovs.06-0557 17122122 (Pubitemid 46729154)
    • (2006) Investigative Ophthalmology and Visual Science , vol.47 , Issue.12 , pp. 5337-5347
    • Kotecha, A.1    Elsheikh, A.2    Roberts, C.R.3    Zhu, H.4    Garway-Heath, D.F.5
  • 24
    • 43049162800 scopus 로고    scopus 로고
    • Corneal hysteresis and axial length among Chinese secondary school children: The Xichang Pediatric Refractive Error Study (X-PRES) Report No. 4
    • 10.1016/j.ajo.2007.12.034 18328999
    • Y Song N Congdon L Li Z Zhou K Choi DS Lam CP Pang Z Xie X Liu A Sharma W Chen M Zhang 2008 Corneal hysteresis and axial length among Chinese secondary school children: the Xichang Pediatric Refractive Error Study (X-PRES) Report No. 4 Am J Ophthalmol 145 819 826 10.1016/j.ajo.2007.12.034 18328999
    • (2008) Am J Ophthalmol , vol.145 , pp. 819-826
    • Song, Y.1    Congdon, N.2    Li, L.3    Zhou, Z.4    Choi, K.5    Lam, D.S.6    Pang, C.P.7    Xie, Z.8    Liu, X.9    Sharma, A.10    Chen, W.11    Zhang, M.12
  • 25
    • 58149123724 scopus 로고    scopus 로고
    • Correlations between corneal biomechanical properties measured with the ocular response analyzer and ICare rebound tonometry
    • 10.1097/IJG.0b013e31815f52b8 18794677
    • JM Jorge JM González-Méijome A Queirós P Fernandes MA Parafita 2008 Correlations between corneal biomechanical properties measured with the ocular response analyzer and ICare rebound tonometry J Glaucoma 17 442 448 10.1097/IJG.0b013e31815f52b8 18794677
    • (2008) J Glaucoma , vol.17 , pp. 442-448
    • Jorge, J.M.1    González-Méijome, J.M.2    Queirós, A.3    Fernandes, P.4    Parafita, M.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.