-
1
-
-
0034115306
-
A new induction-based impact method for measuring intraocular pressure
-
Kontiola A.I. A new induction-based impact method for measuring intraocular pressure. Acta Ophthalmol Scand 78 (2000) 142-145
-
(2000)
Acta Ophthalmol Scand
, vol.78
, pp. 142-145
-
-
Kontiola, A.I.1
-
2
-
-
0035704347
-
The induction/impact tonometer: a new instrument to measure intraocular pressure in the rat
-
Kontiola A.I., Goldblum D., Mittag T., and Danias J. The induction/impact tonometer: a new instrument to measure intraocular pressure in the rat. Exp Eye Res 73 (2001) 781-785
-
(2001)
Exp Eye Res
, vol.73
, pp. 781-785
-
-
Kontiola, A.I.1
Goldblum, D.2
Mittag, T.3
Danias, J.4
-
3
-
-
1142299596
-
Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic
-
Kontiola A., and Puska P. Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic. Graefes Arch Clin Exp Ophthalmol 242 (2004) 3-7
-
(2004)
Graefes Arch Clin Exp Ophthalmol
, vol.242
, pp. 3-7
-
-
Kontiola, A.1
Puska, P.2
-
4
-
-
0029980777
-
Number of people with glaucoma worldwide
-
Quigley H.A. Number of people with glaucoma worldwide. Br J Ophthalmol 80 (1996) 389-393
-
(1996)
Br J Ophthalmol
, vol.80
, pp. 389-393
-
-
Quigley, H.A.1
-
5
-
-
1842425681
-
Prevalence of open-angle glaucoma among adults in the United States
-
Eye Diseases Prevalence Research Group
-
Eye Diseases Prevalence Research Group. Prevalence of open-angle glaucoma among adults in the United States. Arch Ophthalmol 122 (2004) 532-538
-
(2004)
Arch Ophthalmol
, vol.122
, pp. 532-538
-
-
-
6
-
-
0036269833
-
The Ocular Hypertension Treatment Study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucoma
-
Kass M.A., Heuer D.K., Higginbotham E.J., et al. The Ocular Hypertension Treatment Study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucoma. Arch Ophthalmol 120 (2002) 701-713
-
(2002)
Arch Ophthalmol
, vol.120
, pp. 701-713
-
-
Kass, M.A.1
Heuer, D.K.2
Higginbotham, E.J.3
-
7
-
-
0036667747
-
Analysis of risk factors that may be associated with progression from ocular hypertension to primary open angle glaucoma
-
Landers J., Goldberg I., and Graham S.L. Analysis of risk factors that may be associated with progression from ocular hypertension to primary open angle glaucoma. Clin Experiment Ophthalmol 30 (2002) 242-247
-
(2002)
Clin Experiment Ophthalmol
, vol.30
, pp. 242-247
-
-
Landers, J.1
Goldberg, I.2
Graham, S.L.3
-
8
-
-
13844313434
-
Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis
-
Liu J., and Roberts C.J. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg 31 (2005) 146-155
-
(2005)
J Cataract Refract Surg
, vol.31
, pp. 146-155
-
-
Liu, J.1
Roberts, C.J.2
-
9
-
-
13844317411
-
Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
-
Luce D.A. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg 31 (2005) 156-162
-
(2005)
J Cataract Refract Surg
, vol.31
, pp. 156-162
-
-
Luce, D.A.1
-
10
-
-
33644802292
-
Diurnal variation of ocular hysteresis in normal subjects: relevance in clinical context
-
Laiquzzaman M., Bhojwani R., Cunliffe I., et al. Diurnal variation of ocular hysteresis in normal subjects: relevance in clinical context. Clin Experiment Ophthalmol 34 (2006) 114-118
-
(2006)
Clin Experiment Ophthalmol
, vol.34
, pp. 114-118
-
-
Laiquzzaman, M.1
Bhojwani, R.2
Cunliffe, I.3
-
11
-
-
33750598651
-
Effect of 24-hour corneal biomechanical changes on intraocular pressure measurement
-
Kida T., Liu J.H., and Weinreb R.N. Effect of 24-hour corneal biomechanical changes on intraocular pressure measurement. Invest Ophthalmol Vis Sci 47 (2006) 4422-4426
-
(2006)
Invest Ophthalmol Vis Sci
, vol.47
, pp. 4422-4426
-
-
Kida, T.1
Liu, J.H.2
Weinreb, R.N.3
-
12
-
-
15544383865
-
Intraocular pressure measurements after conductive keratoplasty
-
Kymionis G.D., Naoumidi T.L., Aslanides I.M., et al. Intraocular pressure measurements after conductive keratoplasty. J Refract Surg 21 (2005) 171-175
-
(2005)
J Refract Surg
, vol.21
, pp. 171-175
-
-
Kymionis, G.D.1
Naoumidi, T.L.2
Aslanides, I.M.3
-
13
-
-
28244452880
-
Comparison of the ICARE rebound tonometer with the Goldmann tonometer in a normal population
-
Fernandes P., Diaz-Rey J.A., Queiros A., et al. Comparison of the ICARE rebound tonometer with the Goldmann tonometer in a normal population. Ophthalmic Physiol Opt 25 (2005) 436-440
-
(2005)
Ophthalmic Physiol Opt
, vol.25
, pp. 436-440
-
-
Fernandes, P.1
Diaz-Rey, J.A.2
Queiros, A.3
-
14
-
-
0031801250
-
The corneal thickness profile in Hong Kong Chinese
-
Lam A.K., and Douthwaite W.A. The corneal thickness profile in Hong Kong Chinese. Cornea 17 (1998) 384-388
-
(1998)
Cornea
, vol.17
, pp. 384-388
-
-
Lam, A.K.1
Douthwaite, W.A.2
-
15
-
-
0038118688
-
Measuring central corneal thickness with ultrasound pachymetry
-
Realini T., and Lovelace K. Measuring central corneal thickness with ultrasound pachymetry. Optom Vis Sci 80 (2003) 437-439
-
(2003)
Optom Vis Sci
, vol.80
, pp. 437-439
-
-
Realini, T.1
Lovelace, K.2
-
16
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
17
-
-
33644629030
-
Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes
-
García-Resúa C., González-Meijome J.M., Gilino J., and Yebra-Pimentel E. Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes. Optom Vis Sci 83 (2006) 102-107
-
(2006)
Optom Vis Sci
, vol.83
, pp. 102-107
-
-
García-Resúa, C.1
González-Meijome, J.M.2
Gilino, J.3
Yebra-Pimentel, E.4
-
19
-
-
0034603359
-
Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach
-
Doughty M.J., and Zaman M.L. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 44 (2000) 367-408
-
(2000)
Surv Ophthalmol
, vol.44
, pp. 367-408
-
-
Doughty, M.J.1
Zaman, M.L.2
-
20
-
-
33746277068
-
Agreement of rebound tonometer in measuring intraocular pressure with three types of applanation tonometers
-
Nakamura M., Darhad U., Tatsumi Y., et al. Agreement of rebound tonometer in measuring intraocular pressure with three types of applanation tonometers. Am J Ophthalmol 142 (2006) 332-334
-
(2006)
Am J Ophthalmol
, vol.142
, pp. 332-334
-
-
Nakamura, M.1
Darhad, U.2
Tatsumi, Y.3
-
21
-
-
33751505840
-
Effect of corneal thickness on dynamic contour, rebound, and Goldmann tonometry
-
Martinez-de-la-Casa J.M., Garcia-Feijoo J., Vico E., et al. Effect of corneal thickness on dynamic contour, rebound, and Goldmann tonometry. Ophthalmology 113 (2006) 2156-2162
-
(2006)
Ophthalmology
, vol.113
, pp. 2156-2162
-
-
Martinez-de-la-Casa, J.M.1
Garcia-Feijoo, J.2
Vico, E.3
-
22
-
-
0037870104
-
The relationship between central corneal thickness and Goldmann applanation tonometry
-
Lleo A., Marcos A., Calatayud M., et al. The relationship between central corneal thickness and Goldmann applanation tonometry. Clin Exp Optom 86 (2003) 104-108
-
(2003)
Clin Exp Optom
, vol.86
, pp. 104-108
-
-
Lleo, A.1
Marcos, A.2
Calatayud, M.3
-
23
-
-
0035163029
-
Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings
-
Feltgen N., Leifert D., and Funk J. Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings. Br J Ophthalmol 85 (2001) 85-87
-
(2001)
Br J Ophthalmol
, vol.85
, pp. 85-87
-
-
Feltgen, N.1
Leifert, D.2
Funk, J.3
-
24
-
-
0036149032
-
IOP measurement and central corneal thickness
-
[letter]
-
Stodtmeister R., Kron M., and Gaus W. IOP measurement and central corneal thickness. [letter]. Br J Ophthalmol 86 (2002) 120-121
-
(2002)
Br J Ophthalmol
, vol.86
, pp. 120-121
-
-
Stodtmeister, R.1
Kron, M.2
Gaus, W.3
-
25
-
-
33745282996
-
Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients
-
Brusini P., Salvetat M.L., Zeppieri M., et al. Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients. J Glaucoma 15 (2006) 213-217
-
(2006)
J Glaucoma
, vol.15
, pp. 213-217
-
-
Brusini, P.1
Salvetat, M.L.2
Zeppieri, M.3
-
26
-
-
33646901276
-
Measuring intraocular pressure-adjustments for corneal thickness and new technologies
-
Herndon L.W. Measuring intraocular pressure-adjustments for corneal thickness and new technologies. Curr Opin Ophthalmol 17 (2006) 115-119
-
(2006)
Curr Opin Ophthalmol
, vol.17
, pp. 115-119
-
-
Herndon, L.W.1
-
28
-
-
28244471011
-
Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry
-
Van der J., and Jansonius N.M. Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry. Ophthalmic Physiol Opt 25 (2005) 429-435
-
(2005)
Ophthalmic Physiol Opt
, vol.25
, pp. 429-435
-
-
Van der, J.1
Jansonius, N.M.2
-
29
-
-
37349110950
-
-
Abraham LM, Epasinghe NC, Selva D, Casson R. Comparison of the ICare rebound tonometer with Goldmann applanation tonometer by experienced and inexperienced tonometrists. Eye. In press.
-
-
-
-
30
-
-
33845239951
-
Age differences in central and peripheral intra-ocular pressure using a rebound tonometer
-
Gonzalez-Meijome J.M., Jorge J., Queiros A., et al. Age differences in central and peripheral intra-ocular pressure using a rebound tonometer. Br J Ophthalmol 90 (2006) 1495-1500
-
(2006)
Br J Ophthalmol
, vol.90
, pp. 1495-1500
-
-
Gonzalez-Meijome, J.M.1
Jorge, J.2
Queiros, A.3
-
31
-
-
0037562793
-
Collagen fibrils appear more closely packed in the prepupillary cornea: optical and biomechanical implications
-
Boote C., Dennis S., Newton R.H., et al. Collagen fibrils appear more closely packed in the prepupillary cornea: optical and biomechanical implications. Invest Ophthalmol Vis Sci 44 (2003) 2941-2948
-
(2003)
Invest Ophthalmol Vis Sci
, vol.44
, pp. 2941-2948
-
-
Boote, C.1
Dennis, S.2
Newton, R.H.3
-
32
-
-
33847125749
-
Pentacam pachometry: comparison with non-contact specular microscopy on the central cornea, and its inter-session repeatability on the peripheral cornea
-
Lam A.K.C., and Chen D. Pentacam pachometry: comparison with non-contact specular microscopy on the central cornea, and its inter-session repeatability on the peripheral cornea. Clin Exp Optom 90 (2007) 108-114
-
(2007)
Clin Exp Optom
, vol.90
, pp. 108-114
-
-
Lam, A.K.C.1
Chen, D.2
|