메뉴 건너뛰기




Volumn 245, Issue 9, 2007, Pages 1259-1265

Evaluation of the impedance tonometers TGDc-01 and iCare according to the international ocular tonometer standards ISO 8612

Author keywords

Glaucoma; iCare; Impedance tonometer; ISO8612; Rebound tonometer; TGDc 01; Transpalpebral tonometer

Indexed keywords

ADULT; AGED; ARTICLE; CONTROLLED STUDY; CORNEA; CORRELATION COEFFICIENT; GLAUCOMA; HUMAN; IMPEDANCE PLETHYSMOGRAPHY; INTERMETHOD COMPARISON; INTERNATIONAL STANDARD UNIT; MAJOR CLINICAL STUDY; OCULOPLETHYSMOGRAPHY; PORTABLE EQUIPMENT; PRIORITY JOURNAL; TONOMETRY; VISUAL SYSTEM EXAMINATION;

EID: 34548049291     PISSN: 0721832X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00417-006-0483-3     Document Type: Article
Times cited : (23)

References (17)
  • 2
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • Doughty MJ, Zaman ML (2000) Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach. Surv Ophthalmol 44:367-408
    • (2000) Surv Ophthalmol , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 3
    • 0016261804 scopus 로고
    • Central corneal thickness in low-tension glaucoma
    • Ehlers N, Hansen FK (1974) Central corneal thickness in low-tension glaucoma. Acta Ophthalmol (Copenh) 52:740-746
    • (1974) Acta Ophthalmol (Copenh) , vol.52 , pp. 740-746
    • Ehlers, N.1    Hansen, F.K.2
  • 4
    • 11244343319 scopus 로고    scopus 로고
    • Evaluating clinical comparisons for human eye tonometers. A critical assessment of common practice
    • Elster C, Schwenteck T, Tilgner J et al (1998) Evaluating clinical comparisons for human eye tonometers. A critical assessment of common practice. New trends Ophthalmol 12:91-96
    • (1998) New Trends Ophthalmol , vol.12 , pp. 91-96
    • Elster, C.1    Schwenteck, T.2    Tilgner, J.3
  • 7
    • 28244471011 scopus 로고    scopus 로고
    • Three portable tonometers, the TGDc-01, the iCare and the Tonopen XL, compared with each other and with Goldmann applanation tonometry
    • van der Jagt LH, Jansonius NM (2005) Three portable tonometers, the TGDc-01, the iCare and the Tonopen XL, compared with each other and with Goldmann applanation tonometry. Ophthalmic Physiol Opt 25:429-435, Sep
    • (2005) Ophthalmic Physiol Opt , vol.25 , pp. 429-435
    • van der Jagt, L.H.1    Jansonius, N.M.2
  • 9
    • 0030318702 scopus 로고    scopus 로고
    • A new electromechanical method for measuring intraocular pressure
    • Kontiola A (1996-97) A new electromechanical method for measuring intraocular pressure. Doc Ophthalmol 93:265-276
    • (1996) Doc Ophthalmol , vol.93 , pp. 265-276
    • Kontiola, A.1
  • 10
    • 0034115306 scopus 로고    scopus 로고
    • A new induction-based impact method for measuring intraocular pressure
    • Kontiola A (2000) A new induction-based impact method for measuring intraocular pressure. Acta Ophthalmol Scand 78:142-145
    • (2000) Acta Ophthalmol Scand , vol.78 , pp. 142-145
    • Kontiola, A.1
  • 11
    • 1142299596 scopus 로고    scopus 로고
    • Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic
    • Kontiola A, Puska P (2004) Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic. Graefes Arch Clin Exp Ophthalmol 242:3-7
    • (2004) Graefes Arch Clin Exp Ophthalmol , vol.242 , pp. 3-7
    • Kontiola, A.1    Puska, P.2
  • 12
    • 21244458331 scopus 로고    scopus 로고
    • The validity of a digital eyelid tonometer (TGDc-01) and ist comparison with Goldmann applanation tonometry - A pilot study
    • Lam AK, Lam CH, Chan R (2005) The validity of a digital eyelid tonometer (TGDc-01) and ist comparison with Goldmann applanation tonometry - a pilot study. Ophthalmic Physiol Opt 25:205-210
    • (2005) Ophthalmic Physiol Opt , vol.25 , pp. 205-210
    • Lam, A.K.1    Lam, C.H.2    Chan, R.3
  • 13
    • 10844227265 scopus 로고    scopus 로고
    • Comparison of intraocular pressure measurements with the digitial tonometer TGDc-01'PRA' and the Goldmann applanation tonometer
    • Meyer MW, Gockeln R, Hoy L, Meyer A, Erb C (2004) Comparison of intraocular pressure measurements with the digitial tonometer TGDc-01 'PRA' and the Goldmann applanation tonometer. Ophthalmic Res 36:250-254
    • (2004) Ophthalmic Res , vol.36 , pp. 250-254
    • Meyer, M.W.1    Gockeln, R.2    Hoy, L.3    Meyer, A.4    Erb, C.5
  • 14
    • 6344221844 scopus 로고    scopus 로고
    • Prospektiver Vergleich des neuen Indentationstonometers TGDc-01, dem Non-contact Tonometer PT 100 und dem konventionellen Goldmann Applanationstonometer
    • Mudie;ller A, Godenschwenger L, Lang GE, Kampmeier J (2004) Prospektiver Vergleich des neuen Indentationstonometers TGDc-01, dem Non-contact Tonometer PT 100 und dem konventionellen Goldmann Applanationstonometer. Klin Monatsbl Augenheilkd 221:762-768
    • (2004) Klin Monatsbl Augenheilkd , vol.221 , pp. 762-768
    • Müller, A.1    Godenschwenger, L.2    Lang, G.E.3    Kampmeier, J.4
  • 15
    • 22244463950 scopus 로고    scopus 로고
    • Measurement of the intraocular pressure with the transpalpebral tonometer TGDc-01 in comparison with applanation tonometry
    • Sandner D, Bohm A, Kostov S, Pillunat L (2005) Measurement of the intraocular pressure with the transpalpebral tonometer TGDc-01 in comparison with applanation tonometry. Graefes Arch Clin Exp Ophthalmol 243:563-569
    • (2005) Graefes Arch Clin Exp Ophthalmol , vol.243 , pp. 563-569
    • Sandner, D.1    Bohm, A.2    Kostov, S.3    Pillunat, L.4
  • 16
    • 25844453882 scopus 로고    scopus 로고
    • Deviations between transpalpebral tonometry using TGDc-01 and Goldmann applanation tonometry depending on IOP level
    • Troost A, Specht K, Krummenauer F, Yun SH, Schwenn O (2005) Deviations between transpalpebral tonometry using TGDc-01 and Goldmann applanation tonometry depending on IOP level. Graefes Arch Clin Exp Ophthalmol 243:853-858
    • (2005) Graefes Arch Clin Exp Ophthalmol , vol.243 , pp. 853-858
    • Troost, A.1    Specht, K.2    Krummenauer, F.3    Yun, S.H.4    Schwenn, O.5
  • 17
    • 14744271937 scopus 로고    scopus 로고
    • Transpalpebral tonometry: Reliability and comparison with Goldmann applanation tonometry and palpation in healthy volunteers
    • Troost A, Yun SH, Specht K, Krummenauer F, Schwenn O (2005) Transpalpebral tonometry: Reliability and comparison with Goldmann applanation tonometry and palpation in healthy volunteers. Br J Ophthalmol 89:280-283
    • (2005) Br J Ophthalmol , vol.89 , pp. 280-283
    • Troost, A.1    Yun, S.H.2    Specht, K.3    Krummenauer, F.4    Schwenn, O.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.