메뉴 건너뛰기




Volumn 17, Issue 6, 2008, Pages 442-448

Correlations between corneal biomechanical properties measured with the ocular response analyzer and ICare rebound tonometry

Author keywords

Corneal biomechanics; Corneal thickness; Intraocular pressure; Ocular Response Analyzer; Rebound tonometry

Indexed keywords

ADULT; AGED; ANALYZER; ARTICLE; BIOMECHANICS; CONTROLLED STUDY; CORNEA; CORNEA THICKNESS; ECHOGRAPHY; EYE; HUMAN; INTRAOCULAR PRESSURE; MEASUREMENT; MECHANICAL PROBE; NORMAL HUMAN; NOSE CAVITY; OCULAR RESPONSE ANALYZER; OPHTHALMOLOGY; PRIORITY JOURNAL; REBOUND TONOMETRY; TEMPORAL LOBE; TONOMETER; TONOMETRY; AGING; COMPARATIVE STUDY; ELASTIC TISSUE; HISTOLOGY; METHODOLOGY; MIDDLE AGED; OCULOPLETHYSMOGRAPHY; PHYSIOLOGY;

EID: 58149123724     PISSN: 10570829     EISSN: None     Source Type: Journal    
DOI: 10.1097/IJG.0b013e31815f52b8     Document Type: Article
Times cited : (68)

References (25)
  • 1
    • 7044264342 scopus 로고    scopus 로고
    • The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology
    • Browning AC, Bhan A, Rotchford AP, et al. The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology. Br J Ophthalmol. 2004;88:1395-1399.
    • (2004) Br J Ophthalmol , vol.88 , pp. 1395-1399
    • Browning, A.C.1    Bhan, A.2    Rotchford, A.P.3
  • 2
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000;44:367-408.
    • (2000) Surv Ophthalmol , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 3
    • 0842331147 scopus 로고    scopus 로고
    • Corneal thickness: Measurement and implications
    • Ehlers N, Hjortdal J. Corneal thickness: measurement and implications. Exp Eye Res. 2004;78:543-548.
    • (2004) Exp Eye Res , vol.78 , pp. 543-548
    • Ehlers, N.1    Hjortdal, J.2
  • 4
    • 33644507412 scopus 로고    scopus 로고
    • Central and paracentral corneal pachymetry in patients with normal tension glaucoma and ocular hypertension
    • Jordan JF, Joergens S, Dinslage S, et al. Central and paracentral corneal pachymetry in patients with normal tension glaucoma and ocular hypertension. Graefes Arch Clin Exp Ophthalmol. 2006;244: 177-182.
    • (2006) Graefes Arch Clin Exp Ophthalmol , vol.244 , pp. 177-182
    • Jordan, J.F.1    Joergens, S.2    Dinslage, S.3
  • 5
    • 33646190149 scopus 로고    scopus 로고
    • Central corneal thickness and corneal hysteresis associated with glaucoma damage
    • Congdon NG, Broman AT, Bandeen-Roche K, et al. Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol. 2006;141:868-875.
    • (2006) Am J Ophthalmol , vol.141 , pp. 868-875
    • Congdon, N.G.1    Broman, A.T.2    Bandeen-Roche, K.3
  • 6
    • 0035070611 scopus 로고    scopus 로고
    • Intraocular pressure after excimer laser myopic refractive surgery
    • Montes-Mico R, Charman WN. Intraocular pressure after excimer laser myopic refractive surgery. Ophthalmic Physiol Opt. 2001;21: 228-235.
    • (2001) Ophthalmic Physiol Opt , vol.21 , pp. 228-235
    • Montes-Mico, R.1    Charman, W.N.2
  • 7
    • 67249165913 scopus 로고    scopus 로고
    • Luce D, Taylor D. Reichert Ocular Response Analyzer measures corneal biomechanical properties and IOP. Ocular Response Analyzer White Paper. Available at: http://www.ocularresponseanalyzer.com/downloads.html 2005; Accessed November 2006.
    • Luce D, Taylor D. Reichert Ocular Response Analyzer measures corneal biomechanical properties and IOP. Ocular Response Analyzer White Paper. Available at: http://www.ocularresponseanalyzer.com/downloads.html 2005; Accessed November 2006.
  • 9
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    • Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005;31:156-162.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 156-162
    • Luce, D.A.1
  • 10
    • 33845239951 scopus 로고    scopus 로고
    • Age differences in central and peripheral intraocular pressure using a rebound tonometer
    • Gonzalez-Meijome JM, Jorge J, Queiros A, et al. Age differences in central and peripheral intraocular pressure using a rebound tonometer. Br J Ophthalmol. 2006;90:1495-1500.
    • (2006) Br J Ophthalmol , vol.90 , pp. 1495-1500
    • Gonzalez-Meijome, J.M.1    Jorge, J.2    Queiros, A.3
  • 11
    • 34548029372 scopus 로고    scopus 로고
    • Technical note: A comparison of central and peripheral intraocular pressure using rebound tonometry
    • Queiros A, Gonzalez-Meijome JM, Fernandes P, et al. Technical note: a comparison of central and peripheral intraocular pressure using rebound tonometry. Ophthalmic Physiol Opt. 2007;27:506-511.
    • (2007) Ophthalmic Physiol Opt , vol.27 , pp. 506-511
    • Queiros, A.1    Gonzalez-Meijome, J.M.2    Fernandes, P.3
  • 12
    • 1142299596 scopus 로고    scopus 로고
    • Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic
    • Kontiola A, Puska P. Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic. Graefes Arch Clin Exp Ophthalmol. 2004;242:3-7.
    • (2004) Graefes Arch Clin Exp Ophthalmol , vol.242 , pp. 3-7
    • Kontiola, A.1    Puska, P.2
  • 14
    • 0034115306 scopus 로고    scopus 로고
    • A new induction-based impact method for measuring intraocular pressure
    • Kontiola AI. A new induction-based impact method for measuring intraocular pressure. Acta Ophthalmol Scand. 2000;78:142-145.
    • (2000) Acta Ophthalmol Scand , vol.78 , pp. 142-145
    • Kontiola, A.I.1
  • 15
    • 0035704347 scopus 로고    scopus 로고
    • The induction/impact tonometer: A new instrument to measure intraocular pressure in the rat
    • Kontiola AI, Goldblum D, Mittag T, et al. The induction/impact tonometer: a new instrument to measure intraocular pressure in the rat. Exp Eye Res. 2001;73:781-785.
    • (2001) Exp Eye Res , vol.73 , pp. 781-785
    • Kontiola, A.I.1    Goldblum, D.2    Mittag, T.3
  • 16
    • 28244452880 scopus 로고    scopus 로고
    • Comparison of the ICare(R) rebound tonometer with the Goldmann tonometer in a normal population
    • Fernandes P, Diaz-Rey JA, Queiros A, et al. Comparison of the ICare(R) rebound tonometer with the Goldmann tonometer in a normal population. Ophthalmic Physiol Opt. 2005;25: 436-440.
    • (2005) Ophthalmic Physiol Opt , vol.25 , pp. 436-440
    • Fernandes, P.1    Diaz-Rey, J.A.2    Queiros, A.3
  • 17
    • 33644629030 scopus 로고    scopus 로고
    • Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes
    • Garcia-Resua C, Gonzalez-Meijome JM, Gilino J, et al. Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes. Optom Vis Sci. 2006;83:102-107.
    • (2006) Optom Vis Sci , vol.83 , pp. 102-107
    • Garcia-Resua, C.1    Gonzalez-Meijome, J.M.2    Gilino, J.3
  • 19
    • 33847208902 scopus 로고    scopus 로고
    • Technical note: Accuracy and repeatability of a new portable ultrasound pachymeter
    • Queiros A, Gonzalez-Meijome JM, Fernandes P, et al. Technical note: accuracy and repeatability of a new portable ultrasound pachymeter. Ophthalmic Physiol Opt. 2007;27:190-193.
    • (2007) Ophthalmic Physiol Opt , vol.27 , pp. 190-193
    • Queiros, A.1    Gonzalez-Meijome, J.M.2    Fernandes, P.3
  • 20
    • 0033192282 scopus 로고    scopus 로고
    • Further information on the knowledge of topographical corneal thickness
    • Parafita M, Yebra-Pimentel E, Giraldez MJ, et al. Further information on the knowledge of topographical corneal thickness. Int Contact Lens Clin. 1999;26:128-137.
    • (1999) Int Contact Lens Clin , vol.26 , pp. 128-137
    • Parafita, M.1    Yebra-Pimentel, E.2    Giraldez, M.J.3
  • 22
    • 0038118687 scopus 로고    scopus 로고
    • Changes in corneal structure with continuous wear of high-Dk soft contact lenses: A pilot study
    • Gonzalez-Meijome JM, Gonzalez-Perez J, Cervino A, et al. Changes in corneal structure with continuous wear of high-Dk soft contact lenses: a pilot study. Optom Vis Sci. 2003;80:440-446.
    • (2003) Optom Vis Sci , vol.80 , pp. 440-446
    • Gonzalez-Meijome, J.M.1    Gonzalez-Perez, J.2    Cervino, A.3
  • 23
    • 0037255230 scopus 로고    scopus 로고
    • Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry
    • Gonzalez-Meijome JM, Cervino A, Yebra-Pimentel E, et al. Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry. J Cataract Refract Surg. 2003;29:125-132.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 125-132
    • Gonzalez-Meijome, J.M.1    Cervino, A.2    Yebra-Pimentel, E.3
  • 24
    • 13844313434 scopus 로고    scopus 로고
    • Influence of corneal biomechanical properties on intraocular pressure measurement: Quantitative analysis
    • Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg. 2005;31:146-155.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 146-155
    • Liu, J.1    Roberts, C.J.2
  • 25
    • 33646901276 scopus 로고    scopus 로고
    • Measuring intraocular pressure-adjustments for corneal thickness and new technologies
    • Herndon LW. Measuring intraocular pressure-adjustments for corneal thickness and new technologies. Curr Opin Ophthalmol. 2006;17:115-119.
    • (2006) Curr Opin Ophthalmol , vol.17 , pp. 115-119
    • Herndon, L.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.