메뉴 건너뛰기




Volumn 145, Issue 1, 2010, Pages 405-410

A piezoresistive bridge-microcantilever biosensor by CMOS process for surface stress measurement

Author keywords

CMOS; Piezoresistive microcantilever; Surface stress

Indexed keywords

AFM; BATCH FABRICATION; BIOCHEMICAL REACTIONS; CMOS PROCESSS; DESIGN PARAMETERS; LENGTH RATIO; MEASUREMENT SENSITIVITY; MICRO-CANTILEVERS; MICROCANTILEVER BIOSENSORS; ON-CHIP SIGNALS; PIEZO-RESISTIVE; PIEZORESISTOR; SENSOR PERFORMANCE; STANDARD CMOS; STANDARD CMOS PROCESS; SURFACE STRESS; SURFACE STRESS MEASUREMENT; UNI-AXIAL STRAINS;

EID: 76949084922     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2009.12.037     Document Type: Article
Times cited : (23)

References (25)
  • 8
    • 0033977788 scopus 로고    scopus 로고
    • Environmental sensors based on micromachined cantilevers with integrated read-out
    • Boisen A., Thaysen J., Jensenius H., and Hansen O. Environmental sensors based on micromachined cantilevers with integrated read-out. Ultramicroscopy 82 (2000) 11-16
    • (2000) Ultramicroscopy , vol.82 , pp. 11-16
    • Boisen, A.1    Thaysen, J.2    Jensenius, H.3    Hansen, O.4
  • 9
    • 33845659457 scopus 로고    scopus 로고
    • Design and analysis of piezoresistive microcantilever for surface stress measurement in biochemical sensor
    • Yang S.M., and Yin T.I. Design and analysis of piezoresistive microcantilever for surface stress measurement in biochemical sensor. Sens. Actuators B 120 (2007) 736-744
    • (2007) Sens. Actuators B , vol.120 , pp. 736-744
    • Yang, S.M.1    Yin, T.I.2
  • 10
    • 34247556429 scopus 로고    scopus 로고
    • A biosensor chip by CMOS process for surface stress measurement in bioanalyte
    • Yang S.M., Yin T.I., and Chang C. A biosensor chip by CMOS process for surface stress measurement in bioanalyte. Sens. Actuators B 123 (2007) 707-714
    • (2007) Sens. Actuators B , vol.123 , pp. 707-714
    • Yang, S.M.1    Yin, T.I.2    Chang, C.3
  • 15
    • 0026881945 scopus 로고
    • Temperature composition of piezoresistive pressure sensors
    • Akbar M., and Shanblatt M.A. Temperature composition of piezoresistive pressure sensors. Sens. Actuators A 33 (1992) 155-162
    • (1992) Sens. Actuators A , vol.33 , pp. 155-162
    • Akbar, M.1    Shanblatt, M.A.2
  • 16
    • 33846648494 scopus 로고    scopus 로고
    • Development of a double-microcantilever for surface stress measurement in microsensors
    • Yang S.M., Yin T.I., and Chang C. Development of a double-microcantilever for surface stress measurement in microsensors. Sens. Actuators B 121 (2007) 545-551
    • (2007) Sens. Actuators B , vol.121 , pp. 545-551
    • Yang, S.M.1    Yin, T.I.2    Chang, C.3
  • 17
    • 0003532560 scopus 로고    scopus 로고
    • Kluwer Academic Publishers, Norwell p. 474 (Chapter 18)
    • Senturia S.D. Microsystem Design (2002), Kluwer Academic Publishers, Norwell p. 474 (Chapter 18)
    • (2002) Microsystem Design
    • Senturia, S.D.1
  • 18
    • 38949142643 scopus 로고    scopus 로고
    • On the temperature compensation of parallel piezoresistive microcantilevers in CMOS biosensor
    • Yang S.M., Chang C., and Yin T.I. On the temperature compensation of parallel piezoresistive microcantilevers in CMOS biosensor. Sens. Actuators B 129 (2008) 678-684
    • (2008) Sens. Actuators B , vol.129 , pp. 678-684
    • Yang, S.M.1    Chang, C.2    Yin, T.I.3
  • 20
    • 40949091988 scopus 로고    scopus 로고
    • DNA hybridization measurement by self-sensing piezoresistive microcantilevers in CMOS biosensor
    • Yang S.M., Chang C., Yin T.I., and Kuo P.L. DNA hybridization measurement by self-sensing piezoresistive microcantilevers in CMOS biosensor. Sens. Actuators B 130 (2008) 674-681
    • (2008) Sens. Actuators B , vol.130 , pp. 674-681
    • Yang, S.M.1    Chang, C.2    Yin, T.I.3    Kuo, P.L.4
  • 21
    • 60449114768 scopus 로고    scopus 로고
    • Fabrication and characterization of a polymeric microcantilever with an encapsulated hotwire CVD polysilicon piezoresistor
    • Kale N.S., Nag S., Pinto R., and Rao V.R. Fabrication and characterization of a polymeric microcantilever with an encapsulated hotwire CVD polysilicon piezoresistor. J. Microelectromech. Syst. 18 (2009) 79-87
    • (2009) J. Microelectromech. Syst. , vol.18 , pp. 79-87
    • Kale, N.S.1    Nag, S.2    Pinto, R.3    Rao, V.R.4
  • 22
    • 44149110631 scopus 로고    scopus 로고
    • Polyimide microcantilever surface stress sensor using low-cost, rapidly-interchangeable, spring-loaded microprobe connections
    • Ibbotson R.H., Dunn R.J., Djakov V., Ko Ferrigno P., and Huq S.E. Polyimide microcantilever surface stress sensor using low-cost, rapidly-interchangeable, spring-loaded microprobe connections. Microelectron. Eng. 85 (2008) 1314-1317
    • (2008) Microelectron. Eng. , vol.85 , pp. 1314-1317
    • Ibbotson, R.H.1    Dunn, R.J.2    Djakov, V.3    Ko Ferrigno, P.4    Huq, S.E.5
  • 24
    • 14644415474 scopus 로고    scopus 로고
    • Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers
    • Wee K.W., Kang G.Y., Park J., Kang J.Y., Yoon D.S., Park J.H., and Kim T.S. Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers. Biosens. Bioelectron. 20 (2005) 1932-1938
    • (2005) Biosens. Bioelectron. , vol.20 , pp. 1932-1938
    • Wee, K.W.1    Kang, G.Y.2    Park, J.3    Kang, J.Y.4    Yoon, D.S.5    Park, J.H.6    Kim, T.S.7
  • 25
    • 33344459849 scopus 로고    scopus 로고
    • Sensing interactions between vimentin antibodies and antigens for early cancer detection
    • Milburn C., Zhou J., Bravo O., Kumar C., and Soboyejo W.O. Sensing interactions between vimentin antibodies and antigens for early cancer detection. J. Biomed. Nanotechnol. 1 (2005) 30-38
    • (2005) J. Biomed. Nanotechnol. , vol.1 , pp. 30-38
    • Milburn, C.1    Zhou, J.2    Bravo, O.3    Kumar, C.4    Soboyejo, W.O.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.