메뉴 건너뛰기




Volumn 131, Issue 1, 2008, Pages 254-264

A CMOS-based integrated-system architecture for a static cantilever array

Author keywords

Cantilever; CMOS; Deformation; Piezoresistor; Static cantilever; Stress; Wheatstone bridge

Indexed keywords

BIOCHEMICAL ENGINEERING; PIEZOELECTRIC TRANSDUCERS; SENSOR ARRAYS; SIGNAL TO NOISE RATIO; STRESS ANALYSIS; SYSTEMS ANALYSIS;

EID: 41449097840     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2007.11.016     Document Type: Article
Times cited : (24)

References (50)
  • 2
    • 0001682658 scopus 로고
    • Observation of a chemical-reaction using a micromechanical sensor
    • Gimzewski J.K., Gerber C., Meyer E., and Schlittler R.R. Observation of a chemical-reaction using a micromechanical sensor. Chem. Phys. Lett. 217 (1994) 589-594
    • (1994) Chem. Phys. Lett. , vol.217 , pp. 589-594
    • Gimzewski, J.K.1    Gerber, C.2    Meyer, E.3    Schlittler, R.R.4
  • 3
    • 0000435206 scopus 로고
    • Cooperative self-assembly of au atoms and C(60) on Au(110) surfaces
    • Gimzewski J.K., Modesti S., and Schlittler R.R. Cooperative self-assembly of au atoms and C(60) on Au(110) surfaces. Phys. Rev. Lett. 72 (1994) 1036-1039
    • (1994) Phys. Rev. Lett. , vol.72 , pp. 1036-1039
    • Gimzewski, J.K.1    Modesti, S.2    Schlittler, R.R.3
  • 5
    • 0033977788 scopus 로고    scopus 로고
    • Environmental sensors based on micromachined cantilevers with integrated read-out
    • Boisen A., Thaysen J., Jensenius H., and Hansen O. Environmental sensors based on micromachined cantilevers with integrated read-out. Ultramicroscopy 82 (2000) 11-16
    • (2000) Ultramicroscopy , vol.82 , pp. 11-16
    • Boisen, A.1    Thaysen, J.2    Jensenius, H.3    Hansen, O.4
  • 10
    • 0035975015 scopus 로고    scopus 로고
    • Multicomponent analysis and prediction with a cantilever array based gas sensor
    • Kim B.H., Prins F.E., Kern D.P., Raible S., and Weimar U. Multicomponent analysis and prediction with a cantilever array based gas sensor. Sens. Actuators B: Chem. 78 (2001) 12-18
    • (2001) Sens. Actuators B: Chem. , vol.78 , pp. 12-18
    • Kim, B.H.1    Prins, F.E.2    Kern, D.P.3    Raible, S.4    Weimar, U.5
  • 12
    • 0036425166 scopus 로고    scopus 로고
    • Nanomechanics-the link to biology and chemistry
    • Lang H.P., Hegner M., and Gerber C. Nanomechanics-the link to biology and chemistry. Chimia 56 (2002) 515-519
    • (2002) Chimia , vol.56 , pp. 515-519
    • Lang, H.P.1    Hegner, M.2    Gerber, C.3
  • 13
    • 0036646553 scopus 로고    scopus 로고
    • Complementary metal oxide semiconductor cantilever arrays on a single chip: mass-sensitive detection of volatile organic compounds
    • Lange D., Hagleitner C., Hierlemann A., Brand O., and Baltes H. Complementary metal oxide semiconductor cantilever arrays on a single chip: mass-sensitive detection of volatile organic compounds. Anal. Chem. 74 (2002) 3084-3095
    • (2002) Anal. Chem. , vol.74 , pp. 3084-3095
    • Lange, D.1    Hagleitner, C.2    Hierlemann, A.3    Brand, O.4    Baltes, H.5
  • 15
  • 16
    • 18144363562 scopus 로고    scopus 로고
    • Magnetically actuated complementary metal oxide semiconductor resonant cantilever gas sensor systems
    • Vancura C., Ruegg M., Li Y., Hagleitner C., and Hierlemann A. Magnetically actuated complementary metal oxide semiconductor resonant cantilever gas sensor systems. Anal. Chem. 77 (2005) 2690-2699
    • (2005) Anal. Chem. , vol.77 , pp. 2690-2699
    • Vancura, C.1    Ruegg, M.2    Li, Y.3    Hagleitner, C.4    Hierlemann, A.5
  • 17
    • 17644415740 scopus 로고    scopus 로고
    • Optical sequential readout of microcantilever arrays for biological detection
    • Alvarez M., and Tamayo J. Optical sequential readout of microcantilever arrays for biological detection. Sens. Actuators B: Chem. 106 (2005) 687-690
    • (2005) Sens. Actuators B: Chem. , vol.106 , pp. 687-690
    • Alvarez, M.1    Tamayo, J.2
  • 20
    • 13744251078 scopus 로고    scopus 로고
    • Study of the noise of micromechanical oscillators under quality factor enhancement via driving force control
    • Tamayo J. Study of the noise of micromechanical oscillators under quality factor enhancement via driving force control. J. Appl. Phys. 97 (2005)
    • (2005) J. Appl. Phys. , vol.97
    • Tamayo, J.1
  • 21
    • 33751556466 scopus 로고    scopus 로고
    • Effect of the adsorbate stiffness on the resonance response of microcantilever sensors
    • Tamayo J., Ramos D., Mertens J., and Calleja M. Effect of the adsorbate stiffness on the resonance response of microcantilever sensors. Appl. Phys. Lett. 89 (2006)
    • (2006) Appl. Phys. Lett. , vol.89
    • Tamayo, J.1    Ramos, D.2    Mertens, J.3    Calleja, M.4
  • 22
    • 33847214929 scopus 로고    scopus 로고
    • Liquid-phase chemical and biochemical detection using fully integrated magnetically actuated complementary metal oxide semiconductor resonant cantilever sensor systems
    • Vancura C., Li Y., Lichtenberg J., Kirstein K.U., Hierlemann A., and Josse F. Liquid-phase chemical and biochemical detection using fully integrated magnetically actuated complementary metal oxide semiconductor resonant cantilever sensor systems. Anal. Chem. 79 (2007) 1646-1654
    • (2007) Anal. Chem. , vol.79 , pp. 1646-1654
    • Vancura, C.1    Li, Y.2    Lichtenberg, J.3    Kirstein, K.U.4    Hierlemann, A.5    Josse, F.6
  • 24
    • 26644435999 scopus 로고    scopus 로고
    • Microcantilever biosensors
    • Hansen K.M., and Thundat T. Microcantilever biosensors. Methods 37 (2005) 57-64
    • (2005) Methods , vol.37 , pp. 57-64
    • Hansen, K.M.1    Thundat, T.2
  • 25
    • 8444243266 scopus 로고    scopus 로고
    • Molecular recognition of biowarfare agents using micromechanical sensors
    • Ji H.F., Yan X.D., Zhang J., and Thundat T. Molecular recognition of biowarfare agents using micromechanical sensors. Expert Rev. Mol. Diagn. 4 (2004) 859-866
    • (2004) Expert Rev. Mol. Diagn. , vol.4 , pp. 859-866
    • Ji, H.F.1    Yan, X.D.2    Zhang, J.3    Thundat, T.4
  • 26
    • 15444372543 scopus 로고    scopus 로고
    • Dynamic microcantilever sensors for discerning biomolecular interactions
    • Tian F., Hansen K.M., Ferrell T.L., and Thundat T. Dynamic microcantilever sensors for discerning biomolecular interactions. Anal. Chem. 77 (2005) 1601-1606
    • (2005) Anal. Chem. , vol.77 , pp. 1601-1606
    • Tian, F.1    Hansen, K.M.2    Ferrell, T.L.3    Thundat, T.4
  • 28
    • 28344439099 scopus 로고    scopus 로고
    • Characterization of magnetically actuated resonant cantilevers in viscous fluids
    • Vancura C., Lichtenberg J., Hierlemann A., and Josse F. Characterization of magnetically actuated resonant cantilevers in viscous fluids. Appl. Phys. Lett. 87 (2005)
    • (2005) Appl. Phys. Lett. , vol.87
    • Vancura, C.1    Lichtenberg, J.2    Hierlemann, A.3    Josse, F.4
  • 31
    • 33745604726 scopus 로고
    • Adsorption-induced surface stress and its effects on resonance frequency of microcantilevers
    • Chen G.Y., Thundat T., Wachter E.A., and Warmack R.J. Adsorption-induced surface stress and its effects on resonance frequency of microcantilevers. J. Appl. Phys. 77 (1995) 3618-3622
    • (1995) J. Appl. Phys. , vol.77 , pp. 3618-3622
    • Chen, G.Y.1    Thundat, T.2    Wachter, E.A.3    Warmack, R.J.4
  • 32
    • 0036829747 scopus 로고    scopus 로고
    • Microcantilever transducers: a new approach to sensor technology
    • Sepaniak M., Datskos P., Lavrik N., and Tipple C. Microcantilever transducers: a new approach to sensor technology. Anal. Chem. 74 (2002) 568A-575A
    • (2002) Anal. Chem. , vol.74
    • Sepaniak, M.1    Datskos, P.2    Lavrik, N.3    Tipple, C.4
  • 33
    • 41449107952 scopus 로고    scopus 로고
    • T. Volden, CMOS-integrated cantilevers for biosensing and probe microscopy, Dissertation 15984, ETH Zurich, 2005. Available online via: http://e-collection.ethbib.ethz.ch/cgi-bin/show.pl?type=diss&nr=15984.
    • T. Volden, CMOS-integrated cantilevers for biosensing and probe microscopy, Dissertation 15984, ETH Zurich, 2005. Available online via: http://e-collection.ethbib.ethz.ch/cgi-bin/show.pl?type=diss&nr=15984.
  • 34
    • 0031192427 scopus 로고    scopus 로고
    • A low noise CMOS chopper instrumentation amplifier for thermoelectric infrared detectors
    • Menolfi C., and Huang Q. A low noise CMOS chopper instrumentation amplifier for thermoelectric infrared detectors. IEEE J. Solid State. Circ. 32 (1997) 968-976
    • (1997) IEEE J. Solid State. Circ. , vol.32 , pp. 968-976
    • Menolfi, C.1    Huang, Q.2
  • 35
    • 0030195073 scopus 로고    scopus 로고
    • CMOS low-distortion high-frequency variable-gain amplifier
    • Rijns J.J.F. CMOS low-distortion high-frequency variable-gain amplifier. IEEE J. Solid State Circ. 31 (1996) 1029-1034
    • (1996) IEEE J. Solid State Circ. , vol.31 , pp. 1029-1034
    • Rijns, J.J.F.1
  • 37
  • 38
    • 41449107733 scopus 로고    scopus 로고
    • C. Menolfi, Low noise CMOS chopper instrumentation amplifier for thermoelectric microsensors. Dissertation ETH Zurich No. 13583, 2000. Accessible via Internet: http://e-collection.ethbib.ethz.ch/cgi-bin/show.pl?type=diss&nr=13583.
    • C. Menolfi, Low noise CMOS chopper instrumentation amplifier for thermoelectric microsensors. Dissertation ETH Zurich No. 13583, 2000. Accessible via Internet: http://e-collection.ethbib.ethz.ch/cgi-bin/show.pl?type=diss&nr=13583.
  • 39
    • 41449106973 scopus 로고    scopus 로고
    • Philips Semiconductors, Eindhoven, the Netherlands, see: http://www.semiconductors.philips.com/markets/mms/protocols/i2c/facts/.
    • Philips Semiconductors, Eindhoven, the Netherlands, see: http://www.semiconductors.philips.com/markets/mms/protocols/i2c/facts/.
  • 40
    • 0342955717 scopus 로고    scopus 로고
    • An industrial CMOS process family adapted for the fabrication of smart silicon sensors
    • Müller T., Brandl M., Brand O., and Baltes H. An industrial CMOS process family adapted for the fabrication of smart silicon sensors. Sens. Actuators A: Phys. 84 (2000) 126-133
    • (2000) Sens. Actuators A: Phys. , vol.84 , pp. 126-133
    • Müller, T.1    Brandl, M.2    Brand, O.3    Baltes, H.4
  • 42
    • 0001936061 scopus 로고    scopus 로고
    • Reduction of mechanical stress in micromachined components caused by humidity-induced volume expansion of polymer layers
    • Buchhold R., Nakladal A., Gerlach G., Sahre K., Eichhorn K.J., and Muller M. Reduction of mechanical stress in micromachined components caused by humidity-induced volume expansion of polymer layers. Microsyst. Technol. 5 (1998) 3-12
    • (1998) Microsyst. Technol. , vol.5 , pp. 3-12
    • Buchhold, R.1    Nakladal, A.2    Gerlach, G.3    Sahre, K.4    Eichhorn, K.J.5    Muller, M.6
  • 43
    • 0032027987 scopus 로고    scopus 로고
    • The metrological behaviour of bimorphic piezoresistive humidity sensors
    • Buchhold R., Nakladal A., Buttner U., and Gerlach G. The metrological behaviour of bimorphic piezoresistive humidity sensors. Meas. Sci. Technol. 9 (1998) 354-359
    • (1998) Meas. Sci. Technol. , vol.9 , pp. 354-359
    • Buchhold, R.1    Nakladal, A.2    Buttner, U.3    Gerlach, G.4
  • 44
    • 41449112445 scopus 로고    scopus 로고
    • T. Boltshauser, CMOS humidity sensors, PhD Thesis, ETH Zurich No. 10320, Zurich, Switzerland, 1993.
    • T. Boltshauser, CMOS humidity sensors, PhD Thesis, ETH Zurich No. 10320, Zurich, Switzerland, 1993.
  • 45
    • 41449096663 scopus 로고    scopus 로고
    • H. Jensenius, Microcantilever-based studies of bio/chemical systems, PhD Thesis, Mikroelektronik Centret, Technical University of Denmark, Copenhagen, Denmark, 2002.
    • H. Jensenius, Microcantilever-based studies of bio/chemical systems, PhD Thesis, Mikroelektronik Centret, Technical University of Denmark, Copenhagen, Denmark, 2002.
  • 48
    • 30144437424 scopus 로고    scopus 로고
    • Transient signal analysis using complementary metal oxide semiconductor capacitive chemical microsensors
    • Kummer A.M., Burg T.P., and Hierlemann A. Transient signal analysis using complementary metal oxide semiconductor capacitive chemical microsensors. Anal. Chem. 78 (2006) 279-290
    • (2006) Anal. Chem. , vol.78 , pp. 279-290
    • Kummer, A.M.1    Burg, T.P.2    Hierlemann, A.3
  • 49
    • 33749466700 scopus 로고    scopus 로고
    • Detection and discrimination capabilities of a multi-transducer single-chip gas sensor system
    • Kurzawski P., Hagleitner C., and Hierlemann A. Detection and discrimination capabilities of a multi-transducer single-chip gas sensor system. Anal. Chem. 78 (2006) 6910-6920
    • (2006) Anal. Chem. , vol.78 , pp. 6910-6920
    • Kurzawski, P.1    Hagleitner, C.2    Hierlemann, A.3
  • 50
    • 2342565110 scopus 로고    scopus 로고
    • Tuning sensitivity and selectivity of complementary metal oxide semiconductor-based capacitive chemical microsensors
    • Kummer A.M., Hierlemann A., and Baltes H. Tuning sensitivity and selectivity of complementary metal oxide semiconductor-based capacitive chemical microsensors. Anal. Chem. 76 (2004) 2470-2477
    • (2004) Anal. Chem. , vol.76 , pp. 2470-2477
    • Kummer, A.M.1    Hierlemann, A.2    Baltes, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.