메뉴 건너뛰기




Volumn 243, Issue 4, 2005, Pages 359-366

Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration states

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; CADAVER; CLINICAL ARTICLE; CONTROLLED STUDY; CORNEA EDEMA; CORNEA THICKNESS; DEHYDRATION; DIAGNOSTIC ACCURACY; DIAGNOSTIC PROCEDURE; HUMAN; HUMAN TISSUE; IN VITRO STUDY; INTERMETHOD COMPARISON; INTRAOCULAR PRESSURE; LABORATORY TEST; MANOMETRY; OCULOPLETHYSMOGRAPHY; PRIORITY JOURNAL; REPRODUCIBILITY; TONOMETRY;

EID: 20444489648     PISSN: 0721832X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00417-004-1024-6     Document Type: Article
Times cited : (91)

References (29)
  • 1
    • 0034803965 scopus 로고    scopus 로고
    • Central corneal thickness in the ocular hypertension treatment study (OHTS)
    • 10.1016/S0161-6420(01)00760-6
    • Brandt JD, Beiser JA, Kass MA, Gordon MO (2001) Central corneal thickness in the ocular hypertension treatment study (OHTS). Ophthalmology 108:1779-1788 10.1016/S0161-6420(01)00760-6
    • (2001) Ophthalmology , vol.108 , pp. 1779-1788
    • Brandt, J.D.1    Beiser, J.A.2    Kass, M.A.3    Gordon, M.O.4
  • 3
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • 10.1016/S0039-6257(00)00110-7
    • Doughty MJ, Zaman ML (2000) Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach. Surv Ophthalmol 44:367-408 10.1016/S0039-6257(00)00110-7
    • (2000) Surv. Ophthalmol. , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 4
    • 0034874717 scopus 로고    scopus 로고
    • Tonometry after laser in situ keratomileusis treatment
    • 10.1097/00061198-200108000-00003
    • Duch S, Serra A, Castanera J,et al 2001 Tonometry after laser in situ keratomileusis treatment J Glaucoma 10 261-265 10.1097/ 00061198-200108000-00003
    • (2001) J. Glaucoma , vol.10 , pp. 261-265
    • Duch, S.1    Serra, A.2    Castanera, J.3
  • 5
    • 0024822782 scopus 로고
    • Human cadaver corneal thinning for experimental refractive surgery
    • 1:STN:280:By6C1MjnvVI%3D
    • Duffey RJ Tchah H Lindstrom RL 1989 Human cadaver corneal thinning for experimental refractive surgery Refract Corneal Surg 5:41-42 1:STN:280:By6C1MjnvVI%3D
    • (1989) Refract. Corneal Surg. , vol.5 , pp. 41-42
    • Duffey, R.J.1    Tchah, H.2    Lindstrom, R.L.3
  • 6
    • 0016663381 scopus 로고
    • Applanation tonometry and central corneal thickness
    • 1:STN:280:CSqC3crovFU%3D
    • Ehlers N, Bramsen T, Sperling S (1975) Applanation tonometry and central corneal thickness. Acta Ophthalmol (Copenh) 53:34-43 1:STN:280:CSqC3crovFU%3D
    • (1975) Acta Ophthalmol. (Copenh) , vol.53 , pp. 34-43
    • Ehlers, N.1    Bramsen, T.2    Sperling, S.3
  • 7
    • 0031703801 scopus 로고    scopus 로고
    • Tonometry in adults and children. A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo
    • 10.1016/S0161-6420(98)97016-6
    • Eisenberg DL Sherman BG McKeown CA Schuman JS 1998 Tonometry in adults and children. A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo. Ophthalmology 105:1173-1181 10.1016/ S0161-6420(98)97016-6
    • (1998) Ophthalmology , vol.105 , pp. 1173-1181
    • Eisenberg, D.L.1    Sherman, B.G.2    McKeown, C.A.3    Schuman, J.S.4
  • 8
    • 0035163029 scopus 로고    scopus 로고
    • Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings
    • 10.1136/bjo.85.1.85
    • Feltgen N, Leifert D, Funk J (2001) Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings. Br J Ophthalmol 85:85-87 10.1136/bjo.85.1.85
    • (2001) Br. J. Ophthalmol. , vol.85 , pp. 85-87
    • Feltgen, N.1    Leifert, D.2    Funk, J.3
  • 9
    • 77049220240 scopus 로고
    • Un nouveau tonometre d'applanation
    • Goldmann H (1955) Un nouveau tonometre d'applanation. Bull Soc Ophtalmol Fr 67:474-478
    • (1955) Bull. Soc. Ophtalmol. Fr. , vol.67 , pp. 474-478
    • Goldmann, H.1
  • 10
    • 70449195078 scopus 로고
    • Ueber Applanationstonometrie
    • 1:STN:280:CyeD38nptFU%3D
    • Goldmann H, Schmidt T (1957) Ueber Applanationstonometrie. Ophthalmologica 134:221-242 1:STN:280:CyeD38nptFU%3D
    • (1957) Ophthalmologica , vol.134 , pp. 221-242
    • Goldmann, H.1    Schmidt, T.2
  • 11
    • 0013830348 scopus 로고
    • On applanation tonography
    • 1:STN:280:CCmD1MjnvFc%3D
    • Goldmann H, Schmidt T (1965) On applanation tonography. Ophthalmologica 150:65-75 1:STN:280:CCmD1MjnvFc%3D
    • (1965) Ophthalmologica , vol.150 , pp. 65-75
    • Goldmann, H.1    Schmidt, T.2
  • 12
    • 0013992276 scopus 로고
    • Studien mittels Applanationstonographie
    • 1:STN:280:CCeD3c%2FjsVY%3D
    • Goldmann H, Schmidt T (1966) Studien mittels Applanationstonographie. Doc Ophthalmol 20:184-213 1:STN:280:CCeD3c%2FjsVY%3D
    • (1966) Doc. Ophthalmol. , vol.20 , pp. 184-213
    • Goldmann, H.1    Schmidt, T.2
  • 13
    • 0035087326 scopus 로고    scopus 로고
    • Corneal preparation of eye bank eyes for experimental surgery
    • 10.1097/00003226-200104000-00015
    • Hamaoui M, Tahi H, Chapon P et al (2001) Corneal preparation of eye bank eyes for experimental surgery. Cornea 20:317-320 10.1097/ 00003226-200104000-00015
    • (2001) Cornea , vol.20 , pp. 317-320
    • Hamaoui, M.1    Tahi, H.2    Chapon, P.3
  • 14
    • 0017840770 scopus 로고
    • Increased corneal thickness simulating elevated intraocular pressure
    • 1:STN:280:CSeC28rjt1I%3D
    • Johnson M, Kass MA, Moses RA, Grodzki WJ (1978) Increased corneal thickness simulating elevated intraocular pressure. Arch Ophthalmol 96:664-665 1:STN:280:CSeC28rjt1I%3D
    • (1978) Arch. Ophthalmol. , vol.96 , pp. 664-665
    • Johnson, M.1    Kass, M.A.2    Moses, R.A.3    Grodzki, W.J.4
  • 15
    • 0041360373 scopus 로고    scopus 로고
    • Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis
    • 10.1167/iovs.02-0946
    • Kaufmann C, Bachmann LM, Thiel MA (2003) Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis. Invest Ophthalmol Vis Sci 44:3790-3794 10.1167/ iovs.02-0946
    • (2003) Invest. Ophthalmol. Vis. Sci. , vol.44 , pp. 3790-3794
    • Kaufmann, C.1    Bachmann, L.M.2    Thiel, M.A.3
  • 16
    • 4444321895 scopus 로고    scopus 로고
    • Dynamic contour tonometry. A comparative study on human cadaver eyes
    • 10.1001/archopht.122.9.1287
    • Kniestedt C, Nee M, Stamper RL (2004) Dynamic contour tonometry. A comparative study on human cadaver eyes. Arch Ophthalmol 122:1287-1293 10.1001/archopht.122.9.1287
    • (2004) Arch. Ophthalmol. , vol.122 , pp. 1287-1293
    • Kniestedt, C.1    Nee, M.2    Stamper, R.L.3
  • 17
    • 0014274198 scopus 로고
    • A rapid pneumatic applanation tonometer. Comparative findings and evaluation
    • 1:STN:280:CCeC2MfivFA%3D
    • Langham ME, McCarthy E (1968) A rapid pneumatic applanation tonometer. Comparative findings and evaluation. Arch Ophthalmol 79:389-399 1:STN:280:CCeC2MfivFA%3D
    • (1968) Arch. Ophthalmol. , vol.79 , pp. 389-399
    • Langham, M.E.1    McCarthy, E.2
  • 18
    • 0025374874 scopus 로고
    • Effect of corneal hydration and intraocular pressure on keratometric power after experimental radial keratotomy
    • 1:STN:280:By%2BA2c%2Fot1U%3D
    • Maloney RK (1990) Effect of corneal hydration and intraocular pressure on keratometric power after experimental radial keratotomy. Ophthalmology 97:927-933 1:STN:280:By%2BA2c%2Fot1U%3D
    • (1990) Ophthalmology , vol.97 , pp. 927-933
    • Maloney, R.K.1
  • 19
    • 0016788858 scopus 로고
    • Comparison of MacKay-Marg, Goldmann and Perkins tonometers in abnormal corneas
    • 1:STN:280:CSqC28vhtFU%3D
    • McMillan F, Forster PK (1975) Comparison of MacKay-Marg, Goldmann and Perkins tonometers in abnormal corneas. Arch Ophthalmol 93:420-424 1:STN:280:CSqC28vhtFU%3D
    • (1975) Arch. Ophthalmol. , vol.93 , pp. 420-424
    • McMillan, F.1    Forster, P.K.2
  • 20
    • 0001534165 scopus 로고
    • The Goldmann applanation tonometer
    • 1:STN:280:CyaD3srmsFw%3D
    • Moses R (1958) The Goldmann applanation tonometer. Am J Ophthalmol 46:865-869 1:STN:280:CyaD3srmsFw%3D
    • (1958) Am. J. Ophthalmol. , vol.46 , pp. 865-869
    • Moses, R.1
  • 21
    • 0018411106 scopus 로고
    • The pneumatonograph. A laboratory study
    • 1:STN:280:CSaC38zksFc%3D
    • Moses RA, Grodzki WJ (1979) The pneumatonograph. A laboratory study. Arch Ophthalmol 97:547-552 1:STN:280:CSaC38zksFc%3D
    • (1979) Arch. Ophthalmol. , vol.97 , pp. 547-552
    • Moses, R.A.1    Grodzki, W.J.2
  • 22
    • 0035062925 scopus 로고    scopus 로고
    • The specific architecture of the anterior stroma accounts for maintenance of corneal curvature
    • 10.1136/bjo.85.4.437
    • Muller LJ, Pels E, Vrensen GF (2001) The specific architecture of the anterior stroma accounts for maintenance of corneal curvature. Br J Ophthalmol 85:437-443 10.1136/bjo.85.4.437
    • (2001) Br. J. Ophthalmol. , vol.85 , pp. 437-443
    • Muller, L.J.1    Pels, E.2    Vrensen, G.F.3
  • 23
    • 0033498048 scopus 로고    scopus 로고
    • Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic
    • 10.1016/S0161-6420(99)90498-0
    • Shah S, Chatterjee A, Mathai M et al (1999) Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic. Ophthalmology 106:2154-2160 10.1016/S0161-6420(99)90498-0
    • (1999) Ophthalmology , vol.106 , pp. 2154-2160
    • Shah, S.1    Chatterjee, A.2    Mathai, M.3
  • 24
    • 0027411731 scopus 로고
    • Effect of corneal hydration on Goldmann applanation tonometry and corneal topography
    • 1:STN:280:ByyB28vjt1I%3D
    • Simon G, Small RH, Ren Q, Parel JM (1993) Effect of corneal hydration on Goldmann applanation tonometry and corneal topography. Refract Corneal Surg 9:110-117 1:STN:280:ByyB28vjt1I%3D
    • (1993) Refract. Corneal Surg. , vol.9 , pp. 110-117
    • Simon, G.1    Small, R.H.2    Ren, Q.3    Parel, J.M.4
  • 25
    • 0034971648 scopus 로고    scopus 로고
    • Central corneal thickness, tonometry, and ocular dimensions in glaucoma and ocular hypertension
    • 10.1097/00061198-200106000-00011
    • Singh RP, Goldberg I, Graham SL et al (2001) Central corneal thickness, tonometry, and ocular dimensions in glaucoma and ocular hypertension. J Glaucoma 10:206-210 10.1097/00061198-200106000-00011
    • (2001) J. Glaucoma , vol.10 , pp. 206-210
    • Singh, R.P.1    Goldberg, I.2    Graham, S.L.3
  • 26
    • 0021991302 scopus 로고
    • Dehydration of post-mortem eyes for practice and experimental surgery
    • 1:STN:280:BiqC1cbit1c%3D
    • Swinger CA, Kornmehl EW (1985) Dehydration of post-mortem eyes for practice and experimental surgery. Ophthalmic Surg 16:182-183 1:STN:280:BiqC1cbit1c%3D
    • (1985) Ophthalmic Surg. , vol.16 , pp. 182-183
    • Swinger, C.A.1    Kornmehl, E.W.2
  • 27
    • 0028209182 scopus 로고
    • Hydration changes in cadaver eyes prepared for practice and experimental surgery
    • 1:STN:280:ByuB3cnivFI%3D
    • Terry MA, Ousley PJ, Zjhra ML (1994) Hydration changes in cadaver eyes prepared for practice and experimental surgery. Arch Ophthalmol 112:538-543 1:STN:280:ByuB3cnivFI%3D
    • (1994) Arch. Ophthalmol. , vol.112 , pp. 538-543
    • Terry, M.A.1    Ousley, P.J.2    Zjhra, M.L.3
  • 28
    • 0027269723 scopus 로고
    • The effect of corneal thickness on applanation tonometry
    • 1:STN:280:ByyB2MnhsFY%3D
    • Whitacre MM, Stein RA, Hassanein K (1993) The effect of corneal thickness on applanation tonometry. Am J Ophthalmol 115:592-596 1:STN:280:ByyB2MnhsFY%3D
    • (1993) Am. J. Ophthalmol. , vol.115 , pp. 592-596
    • Whitacre, M.M.1    Stein, R.A.2    Hassanein, K.3
  • 29
    • 0030963090 scopus 로고    scopus 로고
    • Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study
    • 1:STN:280:DyaK1c7psFaqug%3D%3D
    • Wolfs RC, Klaver CC, Vingerling JR et al (1997) Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study. Am J Ophthalmol 123:767-772 1:STN:280:DyaK1c7psFaqug%3D%3D
    • (1997) Am. J. Ophthalmol. , vol.123 , pp. 767-772
    • Wolfs, R.C.1    Klaver, C.C.2    Vingerling, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.