-
2
-
-
0031261472
-
The AAPM/RSNA physics tutorial for residents. X-ray generators
-
J. A. Seibert, " The AAPM/RSNA physics tutorial for residents. X-ray generators.," Radiographics 17 (6), 1533-1557 (1997).
-
(1997)
Radiographics
, vol.17
, Issue.6
, pp. 1533-1557
-
-
Seibert, J.A.1
-
3
-
-
0024756746
-
Screen-film processing systems for medical radiography: A historical review
-
A. G. Haus and J. E. Gullinan, " Screen-film processing systems for medical radiography: A historical review.," Radiographics 9 (6), 1203-1224 (1989).
-
(1989)
Radiographics
, vol.9
, Issue.6
, pp. 1203-1224
-
-
Haus, A.G.1
Gullinan, J.E.2
-
4
-
-
0026707832
-
Automatic film processing: Analysis of 9 years of observations
-
O. H. Suleiman, B. J. Conway, F. G. Rueter, and R. J. Slayton, " Automatic film processing: Analysis of 9 years of observations.," Radiology 185 (1), 25-28 (1992).
-
(1992)
Radiology
, vol.185
, Issue.1
, pp. 25-28
-
-
Suleiman, O.H.1
Conway, B.J.2
Rueter, F.G.3
Slayton, R.J.4
-
5
-
-
0036173857
-
High frequency x-ray generator basics
-
W. T. Sobol, " High frequency x-ray generator basics.," Med. Phys. 29 (2), 132-144 (2002).
-
(2002)
Med. Phys.
, vol.29
, Issue.2
, pp. 132-144
-
-
Sobol, W.T.1
-
6
-
-
0025941633
-
Effects of voltage ripple and current mode on diagnostic x-ray spectra and exposures
-
M. Matsumoto, H. Kubota, and H. Hayashi, " Effects of voltage ripple and current mode on diagnostic x-ray spectra and exposures.," Med. Phys. 18 (5), 921-927 (1991).
-
(1991)
Med. Phys.
, vol.18
, Issue.5
, pp. 921-927
-
-
Matsumoto, M.1
Kubota, H.2
Hayashi, H.3
-
7
-
-
0027328328
-
Effects of x-ray tube-voltage ripple and current mode on patient dose
-
H. Kubota, Y. Ozaki, M. Matsumoto, and H. Kanamori, " Effects of x-ray tube-voltage ripple and current mode on patient dose.," Med. Phys. 20 (4), 1023-1028 (1993).
-
(1993)
Med. Phys.
, vol.20
, Issue.4
, pp. 1023-1028
-
-
Kubota, H.1
Ozaki, Y.2
Matsumoto, M.3
Kanamori, H.4
-
8
-
-
0026601258
-
Dose reduction by the use of erbium filtration in a general radiographic room
-
R. W. Cranage, C. J. Howard, and A. D. Welsh, " Dose reduction by the use of erbium filtration in a general radiographic room.," Br. J. Radiol. 65 (771), 232-237 (1992).
-
(1992)
Br. J. Radiol.
, vol.65
, Issue.771
, pp. 232-237
-
-
Cranage, R.W.1
Howard, C.J.2
Welsh, A.D.3
-
9
-
-
0025806215
-
Evaluation of the use of a niobium filter for patient dose reduction in chest radiography
-
H. Thierens, M. Kunnen, A. Van der Plaetsen, and O. Segaert, " Evaluation of the use of a niobium filter for patient dose reduction in chest radiography.," Br. J. Radiol. 64 (760), 334-340 (1991).
-
(1991)
Br. J. Radiol.
, vol.64
, Issue.760
, pp. 334-340
-
-
Thierens, H.1
Kunnen, M.2
Van Der Plaetsen, A.3
Segaert, O.4
-
10
-
-
0021948754
-
Physical measurements of heavy metal filter performance
-
A. E. Burgess, " Physical measurements of heavy metal filter performance.," Med. Phys. 12 (2), 225-228 (1985).
-
(1985)
Med. Phys.
, vol.12
, Issue.2
, pp. 225-228
-
-
Burgess, A.E.1
-
11
-
-
0027687851
-
Factors affecting x-ray spectra
-
E. L. Nickoloff and H. L. Berman, " Factors affecting x-ray spectra.," Radiographics 13 (6), 1337-1348 (1993).
-
(1993)
Radiographics
, vol.13
, Issue.6
, pp. 1337-1348
-
-
Nickoloff, E.L.1
Berman, H.L.2
-
12
-
-
0015414322
-
X-ray exposure reduction using rare-earth oxysulfide intensifying screens
-
A. Buchanan, S. I. Finkelstein, and K. A. Wickersheim, " X-ray exposure reduction using rare-earth oxysulfide intensifying screens.," Radiology 105 (1), 185-190 (1972).
-
(1972)
Radiology
, vol.105
, Issue.1
, pp. 185-190
-
-
Buchanan, A.1
Finkelstein, S.I.2
Wickersheim, K.A.3
-
13
-
-
0016884079
-
Prospects for x-ray exposure reduction using rare earth intensifying screens
-
R. F. Wagner and K. E. Weaver, " Prospects for x-ray exposure reduction using rare earth intensifying screens.," Radiology 118 (1), 183-188 (1976).
-
(1976)
Radiology
, vol.118
, Issue.1
, pp. 183-188
-
-
Wagner, R.F.1
Weaver, K.E.2
-
14
-
-
0019946245
-
Comparative evaluation of several rare-earth film-screen systems
-
M. Braun and B. C. Wilson, " Comparative evaluation of several rare-earth film-screen systems.," Radiology 144 (4), 915-919 (1982).
-
(1982)
Radiology
, vol.144
, Issue.4
, pp. 915-919
-
-
Braun, M.1
Wilson, B.C.2
-
15
-
-
0020743971
-
Rare-earth screens versus calcium tungstate screens
-
R. A. Wilson, " Rare-earth screens versus calcium tungstate screens.," Radiology 147 (1), 288-289 (1983).
-
(1983)
Radiology
, vol.147
, Issue.1
, pp. 288-289
-
-
Wilson, R.A.1
-
16
-
-
0020357565
-
Clinical comparison of high-speed rare-earth screen and par-speed screen for diagnostic efficacy and radiation dosage
-
T. Robinson, J. A. Becker, and A. P. Olson, " Clinical comparison of high-speed rare-earth screen and par-speed screen for diagnostic efficacy and radiation dosage.," Radiology 145 (1), 214-216 (1982).
-
(1982)
Radiology
, vol.145
, Issue.1
, pp. 214-216
-
-
Robinson, T.1
Becker, J.A.2
Olson, A.P.3
-
17
-
-
0003959788
-
-
A. G. Haus, ed., (Medical Physics Publishing, Madison, WI).
-
A. G. Haus, ed., Film Processing in Medical Imaging (Medical Physics Publishing, Madison, WI, 1993).
-
(1993)
Film Processing in Medical Imaging
-
-
-
18
-
-
0030639345
-
Technical aspects of screen-film radiography, film processing, and quality control
-
J. E. Gray, " Technical aspects of screen-film radiography, film processing, and quality control.," Radiographics 17 (1), 177-187 (1997).
-
(1997)
Radiographics
, vol.17
, Issue.1
, pp. 177-187
-
-
Gray, J.E.1
-
19
-
-
56749096619
-
-
AAPM Re No. 94, Validating Automatic Film Processor Performance. AAPM Publisher, College Park, MD.
-
O. Suleiman, G. T. Barnes, P. C. Bunch, P. F. Butler, J. E. Gray, A. G. Haus, M. H. McKetty, E. L. Nickoloff, M. V. Pina, R. J. Pizzutiello, S. J. Shepard, D. C. Spelic, K. J. Strauss, S. R. Szeglin, and R. A. Uzenoff, AAPM Rep. No. 94, Validating Automatic Film Processor Performance. AAPM Publisher, College Park, MD, 2006.
-
(2006)
-
-
Suleiman, O.1
Barnes, G.T.2
Bunch, P.C.3
Butler, P.F.4
Gray, J.E.5
Haus, A.G.6
McKetty, M.H.7
Nickoloff, E.L.8
Pina, M.V.9
Pizzutiello, R.J.10
Shepard, S.J.11
Spelic, D.C.12
Strauss, K.J.13
Szeglin, S.R.14
Uzenoff, R.A.15
-
20
-
-
33751254335
-
Comparison of radiation doses to patients undergoing standard radiographic examinations with conventional screen-film radiography, computed radiography and direct digital radiography
-
G. Compagnone, M. C. Baleni, L. Pagan, F. L. Calzolaio, L. Barozzi, and C. Bergamini, " Comparison of radiation doses to patients undergoing standard radiographic examinations with conventional screen-film radiography, computed radiography and direct digital radiography.," Br. J. Radiol. 79 (947), 899-904 (2006).
-
(2006)
Br. J. Radiol.
, vol.79
, Issue.947
, pp. 899-904
-
-
Compagnone, G.1
Baleni, M.C.2
Pagan, L.3
Calzolaio, F.L.4
Barozzi, L.5
Bergamini, C.6
-
21
-
-
33748907176
-
Optimization of dose and image quality for computed radiography and digital radiography
-
J. E. Aldrich, E. Duran, P. Dunlop, and J. R. Mayo, " Optimization of dose and image quality for computed radiography and digital radiography.," J. Digit Imaging 19 (2), 126-131 (2006).
-
(2006)
J. Digit Imaging
, vol.19
, Issue.2
, pp. 126-131
-
-
Aldrich, J.E.1
Duran, E.2
Dunlop, P.3
Mayo, J.R.4
-
22
-
-
16644387283
-
Strategies for dose reduction in ordinary radiographic examinations using CR and DR
-
0301-0449 (), ();, Pediatr. Radiol. 34 (3), S234-S412 (2004).
-
C. E. Willis, " Strategies for dose reduction in ordinary radiographic examinations using CR and DR.," Pediatr. Radiol. 0301-0449 34 (3), S196-S200 (2004); C. E. Willis, Pediatr. Radiol. 34 (3), S234-S412 (2004).
-
(2004)
Pediatr. Radiol.
, vol.34
, Issue.3
-
-
Willis, C.E.1
Willis, C.E.2
-
23
-
-
0016505239
-
Letter: Field emission 350 kVp chest X-ray system
-
F. M. Charbonnier, " Letter: Field emission 350 kVp chest X-ray system.," Radiography 41 (485), 131-132 (1975).
-
(1975)
Radiography
, vol.41
, Issue.485
, pp. 131-132
-
-
Charbonnier, F.M.1
-
24
-
-
0017817409
-
350 kVp chest radiography: Review and comparison with 120 kVp
-
A. V. Proto and E. J. Lane, " 350 kVp chest radiography: Review and comparison with 120 kVp.," AJR, Am. J. Roentgenol. 130 (5), 859-866 (1978).
-
(1978)
AJR, Am. J. Roentgenol.
, vol.130
, Issue.5
, pp. 859-866
-
-
Proto, A.V.1
Lane, E.J.2
-
25
-
-
0018883453
-
Theoretical and experimental determination of sensitivity and edge enhancement in xeroradiography and ionography
-
D. Plewes and H. E. Johns, " Theoretical and experimental determination of sensitivity and edge enhancement in xeroradiography and ionography.," Med. Phys. 7 (4), 315-323 (1980).
-
(1980)
Med. Phys.
, vol.7
, Issue.4
, pp. 315-323
-
-
Plewes, D.1
Johns, H.E.2
-
26
-
-
0015710368
-
Xeroradiography
-
J. W. Boag, " Xeroradiography.," Phys. Med. Biol. 18 (1), 3-37 (1973).
-
(1973)
Phys. Med. Biol.
, vol.18
, Issue.1
, pp. 3-37
-
-
Boag, J.W.1
-
27
-
-
0020674901
-
Shaped, lead-loaded acrylic filters for patient exposure reduction and image-quality improvement
-
J. E. Gray, J. G. Stears, and E. D. Frank, " Shaped, lead-loaded acrylic filters for patient exposure reduction and image-quality improvement.," Radiology 146 (3), 825-828 (1983).
-
(1983)
Radiology
, vol.146
, Issue.3
, pp. 825-828
-
-
Gray, J.E.1
Stears, J.G.2
Frank, E.D.3
-
28
-
-
0026831035
-
Beam-shaping device for long-film angiography
-
J. M. Alcorn, A. W. Stanson, C. M. Johnson, and J. G. Stears, " Beam-shaping device for long-film angiography.," Radiographics 12 (2), 323-328 (1992).
-
(1992)
Radiographics
, vol.12
, Issue.2
, pp. 323-328
-
-
Alcorn, J.M.1
Stanson, A.W.2
Johnson, C.M.3
Stears, J.G.4
-
29
-
-
0023087272
-
Low attenuation material for table tops, cassettes and grids: A review
-
A. P. Hufton, C. M. Crosthwaite, J. M. Davies, and L. A. Robinson, " Low attenuation material for table tops, cassettes and grids: A review.," Radiography 53 (607), 17-18 (1987).
-
(1987)
Radiography
, vol.53
, Issue.607
, pp. 17-18
-
-
Hufton, A.P.1
Crosthwaite, C.M.2
Davies, J.M.3
Robinson, L.A.4
-
30
-
-
0020059127
-
Radiation exposure reduction using carbon fiber
-
M. Trefler, " Radiation exposure reduction using carbon fiber.," Radiology 142 (3), 751-754 (1982).
-
(1982)
Radiology
, vol.142
, Issue.3
, pp. 751-754
-
-
Trefler, M.1
-
31
-
-
0017278810
-
Performance evaluation of phototimers
-
E. L. Chaney, W. R. Hendee, and D. L. Hare, " Performance evaluation of phototimers.," Radiology 118 (3), 715-717 (1976).
-
(1976)
Radiology
, vol.118
, Issue.3
, pp. 715-717
-
-
Chaney, E.L.1
Hendee, W.R.2
Hare, D.L.3
-
32
-
-
0019468738
-
Performance of automatic exposure controls when used with rare-earth intensifying screens
-
A. Olson and M. High, " Performance of automatic exposure controls when used with rare-earth intensifying screens.," Radiology 140 (2), 491-498 (1981).
-
(1981)
Radiology
, vol.140
, Issue.2
, pp. 491-498
-
-
Olson, A.1
High, M.2
-
33
-
-
0034513504
-
Phototimer setup for CR imaging
-
E. G. Christodoulou, M. M. Goodsit, H. P. Chan, and T. W. Hepburn, " Phototimer setup for CR imaging.," Med. Phys. 27 (12), 2652-2658 (2000).
-
(2000)
Med. Phys.
, vol.27
, Issue.12
, pp. 2652-2658
-
-
Christodoulou, E.G.1
Goodsit, M.M.2
Chan, H.P.3
Hepburn, T.W.4
-
34
-
-
0020435846
-
Evaluation of an automatic exposure control device for mobile radiography
-
R. P. Rossi, B. D. Hamisch, and W. R. Hendee, " Evaluation of an automatic exposure control device for mobile radiography.," Radiology 145 (3), 823-827 (1982).
-
(1982)
Radiology
, vol.145
, Issue.3
, pp. 823-827
-
-
Rossi, R.P.1
Hamisch, B.D.2
Hendee, W.R.3
-
35
-
-
2942753980
-
Nationwide evaluation of X-ray trends survey of abdomen and lumbosacral spine radiography
-
D. C. Spelic, R. V. Kaczmarek, and O. H. Suleiman, " Nationwide evaluation of X-ray trends survey of abdomen and lumbosacral spine radiography.," Radiology 232 (1), 115-125 (2004).
-
(2004)
Radiology
, vol.232
, Issue.1
, pp. 115-125
-
-
Spelic, D.C.1
Kaczmarek, R.V.2
Suleiman, O.H.3
-
36
-
-
0025144647
-
Average radiation exposure values for three diagnostic radiographic examinations
-
F. G. Rueter, B. J. Conway, J. L. McCrohan, and O. H. Suleiman, " Average radiation exposure values for three diagnostic radiographic examinations.," Radiology 177 (2), 341-345 (1990).
-
(1990)
Radiology
, vol.177
, Issue.2
, pp. 341-345
-
-
Rueter, F.G.1
Conway, B.J.2
McCrohan, J.L.3
Suleiman, O.H.4
-
37
-
-
20244379100
-
Reference values for diagnostic radiology: Application and impact
-
J. E. Gray, B. R. Archer, P. F. Butler, B. B. Hobbs, F. A. Mettler, Jr., R. J. Pizzutiello, Jr., B. A. Schueler, K. J. Strauss, O. H. Suleiman, and M. J. Yaffe, " Reference values for diagnostic radiology: Application and impact.," Radiology 235 (2), 354-358 (2005).
-
(2005)
Radiology
, vol.235
, Issue.2
, pp. 354-358
-
-
Gray, J.E.1
Archer, B.R.2
Butler, P.F.3
Hobbs, B.B.4
Mettler Jr., F.A.5
Pizzutiello Jr., R.J.6
Schueler, B.A.7
Strauss, K.J.8
Suleiman, O.H.9
Yaffe, M.J.10
-
38
-
-
0032964526
-
Patient dosimetry activities in the United States: The nationwide evaluation of X-ray trends (NEXT) and tissue dose handbooks
-
O. H. Suleiman, S. H. Stern, and D. C. Spelic, " Patient dosimetry activities in the United States: The nationwide evaluation of X-ray trends (NEXT) and tissue dose handbooks.," Appl. Radiat. Isot. 50 (1), 247-259 (1999).
-
(1999)
Appl. Radiat. Isot.
, vol.50
, Issue.1
, pp. 247-259
-
-
Suleiman, O.H.1
Stern, S.H.2
Spelic, D.C.3
-
39
-
-
33750138012
-
Patient and staff radiation doses from early radiological examinations (1899-1902)
-
C. J. Kotre, " Patient and staff radiation doses from early radiological examinations (1899-1902).," Br. J. Radiol. 79, 837-842 (2006).
-
(2006)
Br. J. Radiol.
, vol.79
, pp. 837-842
-
-
Kotre, C.J.1
-
40
-
-
85027234911
-
-
Nationwide evaluation of X-ray trends (N.E.X.T.)-Data summaries found at (accessed Aug.).
-
Nationwide evaluation of X-ray trends (N.E.X.T.)-Data summaries found at http://www.fda.gov/cdrh/radhlth/next.html (accessed Aug. 2008).
-
(2008)
-
-
-
41
-
-
0003419494
-
-
NCRP Report No. 100, "," National Council on Radiation Protection and Measurements, Bethesda, MD.
-
NCRP Report No. 100, " Exposure of the U.S. population from diagnostic medical radiation.," National Council on Radiation Protection and Measurements, Bethesda, MD, 1989.
-
(1989)
Exposure of the U.S. Population from Diagnostic Medical Radiation
-
-
-
42
-
-
0022574046
-
Patient exposure trends in medical and dental radiography
-
D. W. Johnson and W. A. Goetz, " Patient exposure trends in medical and dental radiography.," Health Phys. 50 (1), 107-116 (1986).
-
(1986)
Health Phys.
, vol.50
, Issue.1
, pp. 107-116
-
-
Johnson, D.W.1
Goetz, W.A.2
-
43
-
-
0034218363
-
The AAPM/RSNA physics tutorial for residents: General overview of fluoroscopic imaging
-
B. A. Shueler, " The AAPM/RSNA physics tutorial for residents: General overview of fluoroscopic imaging.," Radiographics 20 (4), 1115-1126 (2000).
-
(2000)
Radiographics
, vol.20
, Issue.4
, pp. 1115-1126
-
-
Shueler, B.A.1
-
44
-
-
0025776035
-
Radiation exposure to angiographers under different fluoroscopic imaging conditions
-
J. M. Boone and D. C. Levin, " Radiation exposure to angiographers under different fluoroscopic imaging conditions.," Radiology 180 (3), 861-865 (1991).
-
(1991)
Radiology
, vol.180
, Issue.3
, pp. 861-865
-
-
Boone, J.M.1
Levin, D.C.2
-
45
-
-
0034266457
-
The AAPM/RSNA physics tutorial for residents: X-ray image intensifiers for fluoroscopy
-
J. Wang and T. J. Blackburn, " The AAPM/RSNA physics tutorial for residents: X-ray image intensifiers for fluoroscopy.," Radiographics 20 (5), 1471-1477 (2000).
-
(2000)
Radiographics
, vol.20
, Issue.5
, pp. 1471-1477
-
-
Wang, J.1
Blackburn, T.J.2
-
46
-
-
0019506335
-
An analysis of dose efficiency in image intensified fluoroscopic examinations
-
H. Bernstein and E. P. Muntz, " An analysis of dose efficiency in image intensified fluoroscopic examinations.," Med. Phys. 8 (2), 167-173 (1981).
-
(1981)
Med. Phys.
, vol.8
, Issue.2
, pp. 167-173
-
-
Bernstein, H.1
Muntz, E.P.2
-
47
-
-
34547441020
-
The operation logic of automatic dose control of fluoroscopy system in conjunction with spectral shaping filters
-
P. J. Lin, " The operation logic of automatic dose control of fluoroscopy system in conjunction with spectral shaping filters.," Med. Phys. 34 (8), 3169-3172 (2007).
-
(2007)
Med. Phys.
, vol.34
, Issue.8
, pp. 3169-3172
-
-
Lin, P.J.1
-
48
-
-
85024963393
-
New automated fluoroscopic systems for pediatric applications
-
Z. F. Lu, E. L. Nickoloff, C. B. Ruzal-Shapiro, J. C. So, and A. K. Dutta, " New automated fluoroscopic systems for pediatric applications.," Med. Phys. 6 (4), 88-105 (2005).
-
(2005)
Med. Phys.
, vol.6
, Issue.4
, pp. 88-105
-
-
Lu, Z.F.1
Nickoloff, E.L.2
Ruzal-Shapiro, C.B.3
So, J.C.4
Dutta, A.K.5
-
49
-
-
0033975295
-
Skin sparing in interventional radiology: The effect of copper filtration
-
R. Nicholson, F. Tuffee, and M. C. Uthappa, " Skin sparing in interventional radiology: The effect of copper filtration.," Br. J. Radiol. 73, 36-42 (2000).
-
(2000)
Br. J. Radiol.
, vol.73
, pp. 36-42
-
-
Nicholson, R.1
Tuffee, F.2
Uthappa, M.C.3
-
50
-
-
0036703707
-
Effect of radiographic techniques (kVp and mAs) on image quality and patient doses in digital subtraction angiography
-
N. A. Gkanatsios, W. Huda, and K. Peters, " Effect of radiographic techniques (kVp and mAs) on image quality and patient doses in digital subtraction angiography.," Med. Phys. 29 (8), 1643-1650 (2002).
-
(2002)
Med. Phys.
, vol.29
, Issue.8
, pp. 1643-1650
-
-
Gkanatsios, N.A.1
Huda, W.2
Peters, K.3
-
51
-
-
0035286486
-
The AAPM/RSNA physics tutorial for residents: Digital fluoroscopy
-
R. A. Pooley, J. M. McKinney, and D. A. Miller, " The AAPM/RSNA physics tutorial for residents: Digital fluoroscopy.," Radiographics 21 (2), 521-534 (2001).
-
(2001)
Radiographics
, vol.21
, Issue.2
, pp. 521-534
-
-
Pooley, R.A.1
McKinney, J.M.2
Miller, D.A.3
-
52
-
-
0035996468
-
Image quality evaluation of flat panel and image intensifier digital magnification in x-ray fluoroscopy
-
Y. Srinivas and D. L. Wilson, " Image quality evaluation of flat panel and image intensifier digital magnification in x-ray fluoroscopy.," Med. Phys. 29 (7), 1611-1621 (2002).
-
(2002)
Med. Phys.
, vol.29
, Issue.7
, pp. 1611-1621
-
-
Srinivas, Y.1
Wilson, D.L.2
-
53
-
-
0029858672
-
Reduction of radiation dose in pediatric patients using pulsed fluoroscopy
-
R. S. Hernandez and M. M. Goodsitt, " Reduction of radiation dose in pediatric patients using pulsed fluoroscopy.," AJR, Am. J. Roentgenol. 167 (5), 1247-1253 (1996).
-
(1996)
AJR, Am. J. Roentgenol.
, vol.167
, Issue.5
, pp. 1247-1253
-
-
Hernandez, R.S.1
Goodsitt, M.M.2
-
54
-
-
0028085296
-
Perceptual comparison of pulsed and continuous fluoroscopy
-
R. Aufrichtig, P. Xue, C. W. Thomas, G. C. Gilmore, and D. L. Wilson, " Perceptual comparison of pulsed and continuous fluoroscopy.," Med. Phys. 21 (2), 245-256 (1994).
-
(1994)
Med. Phys.
, vol.21
, Issue.2
, pp. 245-256
-
-
Aufrichtig, R.1
Xue, P.2
Thomas, C.W.3
Gilmore, G.C.4
Wilson, D.L.5
-
55
-
-
0031804914
-
Effects of motion blurring in x-ray fluoroscopy
-
P. Xue and D. L. Wilson, " Effects of motion blurring in x-ray fluoroscopy.," Med. Phys. 25 (5), 587-599 (1998).
-
(1998)
Med. Phys.
, vol.25
, Issue.5
, pp. 587-599
-
-
Xue, P.1
Wilson, D.L.2
-
56
-
-
0028605949
-
Perception of fluoroscopy last-image hold
-
D. L. Wilson, P. Xue, and R. Aufrichtig, " Perception of fluoroscopy last-image hold.," Med. Phys. 21, 1875-1883 (1994).
-
(1994)
Med. Phys.
, vol.21
, pp. 1875-1883
-
-
Wilson, D.L.1
Xue, P.2
Aufrichtig, R.3
-
57
-
-
0035403070
-
Fluoroscopy: Patient radiation exposure issues
-
M. Mahesh, " Fluoroscopy: Patient radiation exposure issues.," Radiographics 21 (4), 1033-1045 (2001).
-
(2001)
Radiographics
, vol.21
, Issue.4
, pp. 1033-1045
-
-
Mahesh, M.1
-
58
-
-
0030956525
-
Effect of patient support pads on image quality and dose in fluoroscopy
-
W. R. Geiser, W. Huda, and N. Gkanatsios, " Effect of patient support pads on image quality and dose in fluoroscopy.," Med. Phys. 24 (3), 377-382 (1997).
-
(1997)
Med. Phys.
, vol.24
, Issue.3
, pp. 377-382
-
-
Geiser, W.R.1
Huda, W.2
Gkanatsios, N.3
-
59
-
-
0034331584
-
The AAPM/RSNA physics tutorial for residents: Fluoroscopy: Optical coupling and the video system
-
M. S. Van Lysel, " The AAPM/RSNA physics tutorial for residents: Fluoroscopy: Optical coupling and the video system.," Radiographics 20 (6), 1769-1786 (2000).
-
(2000)
Radiographics
, vol.20
, Issue.6
, pp. 1769-1786
-
-
Van Lysel, M.S.1
-
60
-
-
0018171943
-
A variable aperture fluoroscopic unit for reduced patient exposure
-
R. P. Rossi, R. L. Wesenberg, and W. R. Hendee, " A variable aperture fluoroscopic unit for reduced patient exposure.," Radiology 129 (3), 799-802 (1978).
-
(1978)
Radiology
, vol.129
, Issue.3
, pp. 799-802
-
-
Rossi, R.P.1
Wesenberg, R.L.2
Hendee, W.R.3
-
61
-
-
0021277162
-
Videofluorography: The role of temporal averaging
-
J. A. Rowlands, " Videofluorography: The role of temporal averaging.," Med. Phys. 11 (2), 129-136 (1984).
-
(1984)
Med. Phys.
, vol.11
, Issue.2
, pp. 129-136
-
-
Rowlands, J.A.1
-
62
-
-
0022614195
-
Radiation exposure from conventional and digital subtraction angiography of cerebral vessels
-
M. B. Plunkett, J. E. Gray, and D. B. Kispert, " Radiation exposure from conventional and digital subtraction angiography of cerebral vessels.," AJNR Am. J. Neuroradiol. 7 (4), 665-668 (1986).
-
(1986)
AJNR Am. J. Neuroradiol.
, vol.7
, Issue.4
, pp. 665-668
-
-
Plunkett, M.B.1
Gray, J.E.2
Kispert, D.B.3
-
63
-
-
33846439381
-
Influence of flat-panel fluoroscopic equipment variables on cardiac radiation doses
-
E. L. Nickoloff, Z. F. Lu, A. Dutta, J. S. So, S. Balter, and J. Moses, " Influence of flat-panel fluoroscopic equipment variables on cardiac radiation doses.," Cardiovasc. Intervent Radiol. 30 (2), 169-176 (2007).
-
(2007)
Cardiovasc. Intervent Radiol.
, vol.30
, Issue.2
, pp. 169-176
-
-
Nickoloff, E.L.1
Lu, Z.F.2
Dutta, A.3
So, J.S.4
Balter, S.5
Moses, J.6
-
64
-
-
0028204212
-
The x-ray fovea, a device for reducing x-ray dose in fluoroscopy
-
M. S. Labbe, M. Y. Chiu, M. S. Rzeszotarski, A. R. Bani-Hashemi, and D. L. Wilson, " The x-ray fovea, a device for reducing x-ray dose in fluoroscopy.," Med. Phys. 21 (3), 471-481 (1994).
-
(1994)
Med. Phys.
, vol.21
, Issue.3
, pp. 471-481
-
-
Labbe, M.S.1
Chiu, M.Y.2
Rzeszotarski, M.S.3
Bani-Hashemi, A.R.4
Wilson, D.L.5
-
65
-
-
33645800787
-
Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures
-
K. Chida, H. Saito, H. Otani, M. Kohzuki, S. Takahashi, S. Yamada, K. Shirato, and M. Zuguchi, " Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures.," AJR, Am. J. Roentgenol. 186 (3), 774-778 (2006).
-
(2006)
AJR, Am. J. Roentgenol.
, vol.186
, Issue.3
, pp. 774-778
-
-
Chida, K.1
Saito, H.2
Otani, H.3
Kohzuki, M.4
Takahashi, S.5
Yamada, S.6
Shirato, K.7
Zuguchi, M.8
-
66
-
-
0031466298
-
A new diamentor for measuring kerma-area product and air-kerma simultaneously
-
H. Gfirtner, F. E. Stieve, and J. Wild, " A new diamentor for measuring kerma-area product and air-kerma simultaneously.," Med. Phys. 24 (12), 1954-1959 (1997).
-
(1997)
Med. Phys.
, vol.24
, Issue.12
, pp. 1954-1959
-
-
Gfirtner, H.1
Stieve, F.E.2
Wild, J.3
-
67
-
-
0036732618
-
Comparison of four methods for assessing patient effective dose from radiological examinations
-
N. Theocharopoulos, K. Perisinakis, J. Damilakis, H. Varveris, and N. Gourtsoyiannis, " Comparison of four methods for assessing patient effective dose from radiological examinations.," Med. Phys. 29 (9), 2070-2079 (2002).
-
(2002)
Med. Phys.
, vol.29
, Issue.9
, pp. 2070-2079
-
-
Theocharopoulos, N.1
Perisinakis, K.2
Damilakis, J.3
Varveris, H.4
Gourtsoyiannis, N.5
-
68
-
-
0028297659
-
Estimation of effective dose from dose-area product measurements for barium meals and barium enemas
-
D. Hart and B. F. Wall, " Estimation of effective dose from dose-area product measurements for barium meals and barium enemas.," Br. J. Radiol. 67 (797), 485-489 (1994).
-
(1994)
Br. J. Radiol.
, vol.67
, Issue.797
, pp. 485-489
-
-
Hart, D.1
Wall, B.F.2
-
69
-
-
0027529683
-
Attenuation properties of lead composite aprons
-
P. H. Murphy, Y. Wu, and S. A. Glaze, " Attenuation properties of lead composite aprons.," Radiology 186 (1), 269-272 (1993).
-
(1993)
Radiology
, vol.186
, Issue.1
, pp. 269-272
-
-
Murphy, P.H.1
Wu, Y.2
Glaze, S.A.3
-
70
-
-
0036135651
-
Using a sterile disposable protective surgical drape for reduction of radiation exposure to interventionalists
-
J. N. King, A. M. Champlin, C. A. Kelsey, and D. A. Tripp, " Using a sterile disposable protective surgical drape for reduction of radiation exposure to interventionalists.," AJR, Am. J. Roentgenol. 178 (1), 153-157 (2002).
-
(2002)
AJR, Am. J. Roentgenol.
, vol.178
, Issue.1
, pp. 153-157
-
-
King, J.N.1
Champlin, A.M.2
Kelsey, C.A.3
Tripp, D.A.4
-
71
-
-
18544388948
-
Recent history of the shielding of medical x-ray imaging facilities
-
B. R. Archer, " Recent history of the shielding of medical x-ray imaging facilities.," Health Phys. 88 (6), 579-586 (2005).
-
(2005)
Health Phys.
, vol.88
, Issue.6
, pp. 579-586
-
-
Archer, B.R.1
-
72
-
-
0032916191
-
Diagnostic medical exposures in the U.K. {Review}
-
P. C. Shrimpton, B. F. Wall, and D. Hart, " Diagnostic medical exposures in the U.K. {Review}.," Appl. Radiat. Isot. 50 (1), 261-269 (1999).
-
(1999)
Appl. Radiat. Isot.
, vol.50
, Issue.1
, pp. 261-269
-
-
Shrimpton, P.C.1
Wall, B.F.2
Hart, D.3
-
73
-
-
0003601286
-
-
National Radiation Protection Board NRPb-W14, Chilton, England.
-
D. Hart, M. C. Hilier, and B. F. Wall, " Dose to patients from medical x-ray examinations in U.K.-2000 review.," National Radiation Protection Board NRPb-W14, Chilton, England, 2000.
-
(2000)
Dose to Patients from Medical X-ray Examinations in U.K.-2000 Review
-
-
Hart, D.1
Hilier, M.C.2
Wall, B.F.3
-
74
-
-
0003601286
-
-
Health Protection Agency HPA-RPD-029, Chilton, England.
-
D. Hart, M. C. Hillier, and B. F. Wall, " Dose to patients from medical x-ray examinations in U.K.-2005 review.," Health Protection Agency HPA-RPD-029, Chilton, England, 2005.
-
(2005)
Dose to Patients from Medical X-ray Examinations in U.K.-2005 Review
-
-
Hart, D.1
Hillier, M.C.2
Wall, B.F.3
-
75
-
-
0030228293
-
Radiation-induced skin injuries from fluoroscopy
-
T. B. Shope, " Radiation-induced skin injuries from fluoroscopy.," Radiographics 6 (5), 1195-1199 (1996).
-
(1996)
Radiographics
, vol.6
, Issue.5
, pp. 1195-1199
-
-
Shope, T.B.1
-
76
-
-
0032823443
-
The potential for radiation-induced skin damage in interventional neuroradiological procedures: A review of 522 cases using automated dosimetry
-
T. J. O'Dea, R. A. Geise, and E. R. Ritenour, " The potential for radiation-induced skin damage in interventional neuroradiological procedures: A review of 522 cases using automated dosimetry.," Med. Phys. 26, 2027-2033 (1999).
-
(1999)
Med. Phys.
, vol.26
, pp. 2027-2033
-
-
O'Dea, T.J.1
Geise, R.A.2
Ritenour, E.R.3
-
77
-
-
0028185452
-
Potential biological effects following high x-ray dose interventional procedures
-
L. K. Wagner, P. J. Eifel, and R. A. Geise, " Potential biological effects following high x-ray dose interventional procedures.," J. Vasc. Interv. Radiol. 5, 71-84 (1994).
-
(1994)
J. Vasc. Interv. Radiol.
, vol.5
, pp. 71-84
-
-
Wagner, L.K.1
Eifel, P.J.2
Geise, R.A.3
-
78
-
-
85027233037
-
-
AAPM Report No. 70, Chairs, Cardiac Catheterization Equipment Performance. Med. Phys. Publishing.
-
AAPM Report No. 70, E. L. Nickoloff and K. S. Strauss, Chairs, Cardiac Catheterization Equipment Performance. Med. Phys. Publishing, 2001.
-
(2001)
-
-
Nickoloff, E.L.1
Strauss, K.S.2
-
79
-
-
85024988787
-
Protecting patients by training physicians in fluoroscopic radiation management
-
B. R. Archer and L. K. Wagner, " Protecting patients by training physicians in fluoroscopic radiation management.," J. Appl. Clin. Med. Phys. 1, 32-37 (2000).
-
(2000)
J. Appl. Clin. Med. Phys.
, vol.1
, pp. 32-37
-
-
Archer, B.R.1
Wagner, L.K.2
-
80
-
-
0027251812
-
A survey of fluoroscopic exposure rates: AAPM Task Group No. 11 Report
-
J. M. Boone, D. E. Pfeiffer, K. J. Strauss, R. P. Rossi, P. J. Lin, J. S. Shepard, and B. J. Conway, " A survey of fluoroscopic exposure rates: AAPM Task Group No. 11 Report.," Med. Phys. 20 (3), 789-794 (1993).
-
(1993)
Med. Phys.
, vol.20
, Issue.3
, pp. 789-794
-
-
Boone, J.M.1
Pfeiffer, D.E.2
Strauss, K.J.3
Rossi, R.P.4
Lin, P.J.5
Shepard, J.S.6
Conway, B.J.7
-
81
-
-
0033194931
-
The AAPM/RSNA physics tutorial for residents. Typical patient radiation doses in diagnostic radiology
-
R. A. Parry, S. A. Glaze, and B. R. Archer, " The AAPM/RSNA physics tutorial for residents. Typical patient radiation doses in diagnostic radiology.," Radiographics 19 (5), 1289-1302 (1999).
-
(1999)
Radiographics
, vol.19
, Issue.5
, pp. 1289-1302
-
-
Parry, R.A.1
Glaze, S.A.2
Archer, B.R.3
-
82
-
-
0031003253
-
Nationwide survey of fluoroscopy: Radiation dose and image quality
-
O. H. Suleiman, B. J. Conway, P. Quinn, R. G. Antonsen, F. G. Rueter, R. J. Slayton, and D. C. Spelie, " Nationwide survey of fluoroscopy: Radiation dose and image quality.," Radiology 203 (2), 471-476 (1997).
-
(1997)
Radiology
, vol.203
, Issue.2
, pp. 471-476
-
-
Suleiman, O.H.1
Conway, B.J.2
Quinn, P.3
Antonsen, R.G.4
Rueter, F.G.5
Slayton, R.J.6
Spelie, D.C.7
-
83
-
-
0028001034
-
Optimization of spectral shape in digital mammography: Dependence on anode material, breast thickness, and lesion type
-
R. Fahrig and M. J. Yaffe, " Optimization of spectral shape in digital mammography: Dependence on anode material, breast thickness, and lesion type.," Med. Phys. 21, 1473-1481 (1994).
-
(1994)
Med. Phys.
, vol.21
, pp. 1473-1481
-
-
Fahrig, R.1
Yaffe, M.J.2
-
84
-
-
0028284623
-
Mammograms obtained with rhodium vs molybdenum anodes: Contrast and dose differences
-
C. Kimme-Smith, J. Wang, N. DeBruhl, M. Basic, and L. W. Bassett, " Mammograms obtained with rhodium vs molybdenum anodes: Contrast and dose differences.," AJR, Am. J. Roentgenol. 162, 1313-1317 (1994).
-
(1994)
AJR, Am. J. Roentgenol.
, vol.162
, pp. 1313-1317
-
-
Kimme-Smith, C.1
Wang, J.2
Debruhl, N.3
Basic, M.4
Bassett, L.W.5
-
85
-
-
0030724610
-
Effect of automatic kV selection on dose and contrast for a mammographic X-ray system
-
K. C. Young, M. L. Ramsdale, A. Rust, and J. Cooke, " Effect of automatic kV selection on dose and contrast for a mammographic X-ray system.," Br. J. Radiol. 70, 1036-1042 (1997).
-
(1997)
Br. J. Radiol.
, vol.70
, pp. 1036-1042
-
-
Young, K.C.1
Ramsdale, M.L.2
Rust, A.3
Cooke, J.4
-
87
-
-
56749107243
-
Depth dose data for mammography
-
in, W. W. Logan and E. P. Muntz, eds. (Masson Publishing, New York)
-
G. R. Hammerstein, " Depth dose data for mammography.," in Reduced Dose Mammography, W. W. Logan, and, E. P. Muntz, eds. (Masson Publishing, New York, 1979) pp. 47-56.
-
(1979)
Reduced Dose Mammography
, pp. 47-56
-
-
Hammerstein, G.R.1
-
88
-
-
0018316082
-
Absorbed radiation dose in mammography
-
G. R. Hammerstein, D. W. Miller, D. R. White, M. E. Masterson, H. Q. Woodard, and J. S. Laughlin, " Absorbed radiation dose in mammography.," Radiology 130, 485-491 (1979).
-
(1979)
Radiology
, vol.130
, pp. 485-491
-
-
Hammerstein, G.R.1
Miller, D.W.2
White, D.R.3
Masterson, M.E.4
Woodard, H.Q.5
Laughlin, J.S.6
-
89
-
-
56749170723
-
Average, mid-plane, entrance and other hybrid doses in mammography
-
in, W. W. Logan and E. P. Muntz, eds. (Masson Publishing, New York)
-
E. P. Muntz, " Average, mid-plane, entrance and other hybrid doses in mammography.," in Reduced Dose Mammography, W. W. Logan, and, E. P. Muntz, eds. (Masson Publishing, New York, 1979), pp. 57-60.
-
(1979)
Reduced Dose Mammography
, pp. 57-60
-
-
Muntz, E.P.1
-
90
-
-
56749152417
-
Practical aspects of good quality film/screen mammography
-
in, W. W. Logan and E. P. Muntz, eds. (Masson Publishing, New York)
-
M. E. Masterson and D. W. Miller, " Practical aspects of good quality film/screen mammography.," in Reduced Dose Mammography, W. W. Logan, and, E. P. Muntz, eds. (Masson Publishing, New York, 1979), pp. 329-335.
-
(1979)
Reduced Dose Mammography
, pp. 329-335
-
-
Masterson, M.E.1
Miller, D.W.2
-
91
-
-
0025759912
-
Molybdenum target x-ray spectra: A semiempirical model
-
D. M. Tucker, G. T. Barnes, and X. Z. Wu, " Molybdenum target x-ray spectra: A semiempirical model.," Med. Phys. 18, 402-407 (1991).
-
(1991)
Med. Phys.
, vol.18
, pp. 402-407
-
-
Tucker, D.M.1
Barnes, G.T.2
Wu, X.Z.3
-
92
-
-
0025756532
-
Semiempirical model for generating tungsten target x-ray spectra
-
D. M. Tucker, G. T. Barnes, and D. P. Chakraborty, " Semiempirical model for generating tungsten target x-ray spectra.," Med. Phys. 18, 211-218 (1991).
-
(1991)
Med. Phys.
, vol.18
, pp. 211-218
-
-
Tucker, D.M.1
Barnes, G.T.2
Chakraborty, D.P.3
-
93
-
-
0031466296
-
Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography
-
J. M. Boone, T. R. Fewell, and R. J. Jennings, " Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography.," Med. Phys. 24, 1863-1874 (1997).
-
(1997)
Med. Phys.
, vol.24
, pp. 1863-1874
-
-
Boone, J.M.1
Fewell, T.R.2
Jennings, R.J.3
-
94
-
-
0021997434
-
An approach to specifying a minimum dose system for mammography using multiparameter optimization techniques
-
E. P. Muntz, H. Jafroudi, R. Jennings, and H. Bernstein, " An approach to specifying a minimum dose system for mammography using multiparameter optimization techniques.," Med. Phys. 12, 5-12 (1985).
-
(1985)
Med. Phys.
, vol.12
, pp. 5-12
-
-
Muntz, E.P.1
Jafroudi, H.2
Jennings, R.3
Bernstein, H.4
-
95
-
-
0022476717
-
Absorbed breast dose: Dependence on radiographic modality and technique, and breast thickness
-
S. E. Skubic and P. P. Fatouros, " Absorbed breast dose: Dependence on radiographic modality and technique, and breast thickness.," Radiology 161, 263-270 (1986).
-
(1986)
Radiology
, vol.161
, pp. 263-270
-
-
Skubic, S.E.1
Fatouros, P.P.2
-
96
-
-
0025967743
-
Spectral dependence of glandular tissue dose in screen-film mammography
-
X. Wu, G. T. Barnes, and D. M. Tucker, " Spectral dependence of glandular tissue dose in screen-film mammography.," Radiology 179, 143-148 (1991).
-
(1991)
Radiology
, vol.179
, pp. 143-148
-
-
Wu, X.1
Barnes, G.T.2
Tucker, D.M.3
-
97
-
-
33750556634
-
Suitability of new anode materials in mammography: Dose and subject contrast considerations using Monte Carlo simulation
-
H. Delis, G. Spyrou, L. Costaridou, G. Tzanakos, and G. Panayiotakis, " Suitability of new anode materials in mammography: Dose and subject contrast considerations using Monte Carlo simulation.," Med. Phys. 33, 4221-4235 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 4221-4235
-
-
Delis, H.1
Spyrou, G.2
Costaridou, L.3
Tzanakos, G.4
Panayiotakis, G.5
-
98
-
-
33847655698
-
A synthetic diamond probe for low-energy X-ray dose measurements
-
M. Assiamah, T. L. Nam, and R. J. Keddy, " A synthetic diamond probe for low-energy X-ray dose measurements.," Appl. Radiat. Isot. 65, 545-552 (2007).
-
(2007)
Appl. Radiat. Isot.
, vol.65
, pp. 545-552
-
-
Assiamah, M.1
Nam, T.L.2
Keddy, R.J.3
-
99
-
-
0024343803
-
Dosimetric aspects of film/screen mammography: In-phantom dosimetry with thimble-type ionisation chambers
-
J. Zoetelief, N. J. DeWit, and J. J. Broerse, " Dosimetric aspects of film/screen mammography: In-phantom dosimetry with thimble-type ionisation chambers.," Phys. Med. Biol. 34, 1169-1177 (1989).
-
(1989)
Phys. Med. Biol.
, vol.34
, pp. 1169-1177
-
-
Zoetelief, J.1
Dewit, N.J.2
Broerse, J.J.3
-
100
-
-
13444271654
-
Comparison of mammography radiation dose values obtained from direct incident air kerma measurements with values from measured X-ray spectral data
-
M. Assiamah, T. L. Nam, and R. J. Keddy, " Comparison of mammography radiation dose values obtained from direct incident air kerma measurements with values from measured X-ray spectral data.," Appl. Radiat. Isot. 62, 551-560 (2005).
-
(2005)
Appl. Radiat. Isot.
, vol.62
, pp. 551-560
-
-
Assiamah, M.1
Nam, T.L.2
Keddy, R.J.3
-
101
-
-
30844443702
-
The performance of commercial photodiodes for dosimetry in mammography
-
E. Batista, H. J. Khoury, F. A. Melo, V. Barros, and S. E. Da, Jr., " The performance of commercial photodiodes for dosimetry in mammography.," Radiat. Prot. Dosim. 115, 391-393 (2005).
-
(2005)
Radiat. Prot. Dosim.
, vol.115
, pp. 391-393
-
-
Batista, E.1
Khoury, H.J.2
Melo, F.A.3
Barros, V.4
Da Jr., S.E.5
-
102
-
-
2642588045
-
Towards in vivo TLD dosimetry in mammography
-
H. M. Warren-Forward and L. Duggan, " Towards in vivo TLD dosimetry in mammography.," Br. J. Radiol. 77, 426-432 (2004).
-
(2004)
Br. J. Radiol.
, vol.77
, pp. 426-432
-
-
Warren-Forward, H.M.1
Duggan, L.2
-
103
-
-
0036888310
-
Estimation of mean-glandular dose from monitoring breast entrance skin air kerma using a high sensitivity metal oxide semiconductor field effect transistor (MOSFET) dosimeter system in mammography
-
S. L. Dong, T. C. Chu, J. S. Lee, G. Y. Lan, T. H. Wu, Y. H. Yeh, and J. J. Hwang, " Estimation of mean-glandular dose from monitoring breast entrance skin air kerma using a high sensitivity metal oxide semiconductor field effect transistor (MOSFET) dosimeter system in mammography.," Appl. Radiat. Isot. 57, 791-799 (2002).
-
(2002)
Appl. Radiat. Isot.
, vol.57
, pp. 791-799
-
-
Dong, S.L.1
Chu, T.C.2
Lee, J.S.3
Lan, G.Y.4
Wu, T.H.5
Yeh, Y.H.6
Hwang, J.J.7
-
104
-
-
29144504417
-
Method for determination of the mean fraction of glandular tissue in individual female breasts using mammography
-
J. T. Jansen, W. J. Veldkamp, M. A. Thijssen, W. S. Van, and J. Zoetelief, " Method for determination of the mean fraction of glandular tissue in individual female breasts using mammography.," Phys. Med. Biol. 50, 5953-5967 (2005).
-
(2005)
Phys. Med. Biol.
, vol.50
, pp. 5953-5967
-
-
Jansen, J.T.1
Veldkamp, W.J.2
Thijssen, M.A.3
Van, W.S.4
Zoetelief, J.5
-
105
-
-
0023447283
-
Evaluation of radiation dose, focal spot, and automatic exposure of newer film-screen mammography units
-
C. Kimme-Smith, L. W. Bassett, and R. H. Gold, " Evaluation of radiation dose, focal spot, and automatic exposure of newer film-screen mammography units.," AJR, Am. J. Roentgenol. 149, 913-917 (1987).
-
(1987)
AJR, Am. J. Roentgenol.
, vol.149
, pp. 913-917
-
-
Kimme-Smith, C.1
Bassett, L.W.2
Gold, R.H.3
-
106
-
-
85024990348
-
A tissue-equivalent phantom series for mammography dosimetry
-
W. P. Argo, K. Hintenlang, and D. E. Hintenlang, " A tissue-equivalent phantom series for mammography dosimetry.," J. Appl. Clin. Med. Phys. 5, 112-119 (2004).
-
(2004)
J. Appl. Clin. Med. Phys.
, vol.5
, pp. 112-119
-
-
Argo, W.P.1
Hintenlang, K.2
Hintenlang, D.E.3
-
107
-
-
33644629185
-
Applicability of ACR breast dosimetry methodology to a digital mammography system
-
J. J. Tomon, T. E. Johnson, K. N. Swenson, and D. A. Schauer, " Applicability of ACR breast dosimetry methodology to a digital mammography system.," Med. Phys. 33, 799-807 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 799-807
-
-
Tomon, J.J.1
Johnson, T.E.2
Swenson, K.N.3
Schauer, D.A.4
-
108
-
-
22844452601
-
Are phantoms useful for predicting the potential of dose reduction in full-field digital mammography?
-
G. Gennaro, L. Katz, H. Souchay, C. Alberelli, and M. C. Di, " Are phantoms useful for predicting the potential of dose reduction in full-field digital mammography? " Phys. Med. Biol. 50, 1851-1870 (2005).
-
(2005)
Phys. Med. Biol.
, vol.50
, pp. 1851-1870
-
-
Gennaro, G.1
Katz, L.2
Souchay, H.3
Alberelli, C.4
Di, M.C.5
-
109
-
-
0036318277
-
How good is the ACR accreditation phantom for assessing image quality in digital mammography?
-
W. Huda, A. M. Sajewicz, K. M. Ogden, E. M. Scalzetti, and D. R. Dance, " How good is the ACR accreditation phantom for assessing image quality in digital mammography?," Acad. Radiol. 9, 764-772 (2002).
-
(2002)
Acad. Radiol.
, vol.9
, pp. 764-772
-
-
Huda, W.1
Sajewicz, A.M.2
Ogden, K.M.3
Scalzetti, E.M.4
Dance, D.R.5
-
110
-
-
0032964525
-
Estimating mean glandular dose using proprietary mammography phantoms
-
L. D. Hartley, B. J. Cobb, and D. E. Hutchinson, " Estimating mean glandular dose using proprietary mammography phantoms.," Appl. Radiat. Isot. 50, 205-213 (1999).
-
(1999)
Appl. Radiat. Isot.
, vol.50
, pp. 205-213
-
-
Hartley, L.D.1
Cobb, B.J.2
Hutchinson, D.E.3
-
111
-
-
32944467046
-
Thickness of molybdenum filter and squared contrast-to-noise ratio per dose for digital mammography
-
T. K. Nishino, X. Wu, and R. F. Johnson, Jr., " Thickness of molybdenum filter and squared contrast-to-noise ratio per dose for digital mammography.," AJR, Am. J. Roentgenol. 185, 960-963 (2005).
-
(2005)
AJR, Am. J. Roentgenol.
, vol.185
, pp. 960-963
-
-
Nishino, T.K.1
Wu, X.2
Johnson Jr., R.F.3
-
112
-
-
0026602350
-
Calculation of dose and contrast for two mammographic grids
-
D. R. Dance, J. Persliden, and G. A. Carlsson, " Calculation of dose and contrast for two mammographic grids.," Phys. Med. Biol. 37, 235-248 (1992).
-
(1992)
Phys. Med. Biol.
, vol.37
, pp. 235-248
-
-
Dance, D.R.1
Persliden, J.2
Carlsson, G.A.3
-
113
-
-
0033778108
-
Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol
-
D. R. Dance, C. L. Skinner, K. C. Young, J. R. Beckett, and C. J. Kotre, " Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol.," Phys. Med. Biol. 45, 3225-3240 (2000).
-
(2000)
Phys. Med. Biol.
, vol.45
, pp. 3225-3240
-
-
Dance, D.R.1
Skinner, C.L.2
Young, K.C.3
Beckett, J.R.4
Kotre, C.J.5
-
114
-
-
0027956991
-
Normalized average glandular dose in molybdenum target-rhodium filter and rhodium target-rhodium filter mammography
-
X. Wu, E. L. Gingold, G. T. Barnes, and D. M. Tucker, " Normalized average glandular dose in molybdenum target-rhodium filter and rhodium target-rhodium filter mammography.," Radiology 193, 83-89 (1994).
-
(1994)
Radiology
, vol.193
, pp. 83-89
-
-
Wu, X.1
Gingold, E.L.2
Barnes, G.T.3
Tucker, D.M.4
-
115
-
-
0029051017
-
Assessment of mean glandular dose in mammography
-
K. Faulkner, J. Law, and K. J. Robson, " Assessment of mean glandular dose in mammography.," Br. J. Radiol. 68, 877-881 (1995).
-
(1995)
Br. J. Radiol.
, vol.68
, pp. 877-881
-
-
Faulkner, K.1
Law, J.2
Robson, K.J.3
-
116
-
-
21244497816
-
A high-resolution voxel phantom of the breast for dose calculations in mammography
-
C. Hoeschen, U. Fill, M. Zankl, W. Panzer, D. Regulla, and W. Dohring, " A high-resolution voxel phantom of the breast for dose calculations in mammography.," Radiat. Prot. Dosim. 114, 406-409 (2005).
-
(2005)
Radiat. Prot. Dosim.
, vol.114
, pp. 406-409
-
-
Hoeschen, C.1
Fill, U.2
Zankl, M.3
Panzer, W.4
Regulla, D.5
Dohring, W.6
-
117
-
-
21244469865
-
Average glandular dose conversion coefficients for segmented breast voxel models
-
M. Zankl, U. Fill, C. Hoeschen, W. Panzer, and D. Regulla, " Average glandular dose conversion coefficients for segmented breast voxel models.," Radiat. Prot. Dosim. 114, 410-414 (2005).
-
(2005)
Radiat. Prot. Dosim.
, vol.114
, pp. 410-414
-
-
Zankl, M.1
Fill, U.2
Hoeschen, C.3
Panzer, W.4
Regulla, D.5
-
118
-
-
33645507774
-
Method for the evaluation of a average glandular dose in mammography
-
A. A. Okunade, " Method for the evaluation of a average glandular dose in mammography.," Med. Phys. 33, 1153-1164 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 1153-1164
-
-
Okunade, A.A.1
-
119
-
-
21244447642
-
Breast dosimetry using high-resolution voxel phantoms
-
D. R. Dance, R. A. Hunt, P. R. Bakic, A. D. Maidment, M. Sandborg, G. Ullman, and C. G. Alm, " Breast dosimetry using high-resolution voxel phantoms.," Radiat. Prot. Dosim. 114, 359-363 (2005).
-
(2005)
Radiat. Prot. Dosim.
, vol.114
, pp. 359-363
-
-
Dance, D.R.1
Hunt, R.A.2
Bakic, P.R.3
Maidment, A.D.4
Sandborg, M.5
Ullman, G.6
Alm, C.G.7
-
120
-
-
21244490063
-
Calculation of the properties of digital mammograms using a computer simulation
-
R. A. Hunt, D. R. Dance, P. R. Bakic, A. D. Maidment, M. Sandborg, G. Ullman, and C. G. Alm, " Calculation of the properties of digital mammograms using a computer simulation.," Radiat. Prot. Dosim. 114, 395-398 (2005).
-
(2005)
Radiat. Prot. Dosim.
, vol.114
, pp. 395-398
-
-
Hunt, R.A.1
Dance, D.R.2
Bakic, P.R.3
Maidment, A.D.4
Sandborg, M.5
Ullman, G.6
Alm, C.G.7
-
121
-
-
41449092092
-
The effect of skin thickness determined using breast CT on mammographic dosimetry
-
S. Y. Huang, J. M. Boone, K. Yang, A. L. C. Kwan, and N. J. Packard, " The effect of skin thickness determined using breast CT on mammographic dosimetry.," Med. Phys. 35, 1199-1206 (2008).
-
(2008)
Med. Phys.
, vol.35
, pp. 1199-1206
-
-
Huang, S.Y.1
Boone, J.M.2
Yang, K.3
Kwan, A.L.C.4
Packard, N.J.5
-
122
-
-
0028145652
-
A model for optimization of spectral shape in digital mammography
-
R. Fahrig and M. J. Yaffe, " A model for optimization of spectral shape in digital mammography.," Med. Phys. 21, 1463-1471 (1994).
-
(1994)
Med. Phys.
, vol.21
, pp. 1463-1471
-
-
Fahrig, R.1
Yaffe, M.J.2
-
123
-
-
33750547597
-
X-ray spectrum optimization of full-field digital mammography: Simulation and phantom study
-
P. Bernhardt, T. Mertelmeier, and M. Hoheisel, " X-ray spectrum optimization of full-field digital mammography: Simulation and phantom study.," Med. Phys. 33, 4337-4349 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 4337-4349
-
-
Bernhardt, P.1
Mertelmeier, T.2
Hoheisel, M.3
-
124
-
-
0029875213
-
X-ray imaging with amorphous selenium: Optimal spectra for digital mammography
-
R. Fahrig, J. A. Rowlands, and M. J. Yaffe, " X-ray imaging with amorphous selenium: Optimal spectra for digital mammography.," Med. Phys. 23, 557-567 (1996).
-
(1996)
Med. Phys.
, vol.23
, pp. 557-567
-
-
Fahrig, R.1
Rowlands, J.A.2
Yaffe, M.J.3
-
125
-
-
0030711575
-
Digital tomosynthesis in breast imaging
-
L. T. Niklason, B. T. Christian, L. E. Niklason, D. B. Kopans, D. E. Castleberry, B. H. Opsahl-Ong, C. E. Landberg, P. J. Slanetz, A. A. Giardino, R. Moore, D. Albagli, M. C. DeJule, P. F. Fitzgerald, D. F. Fobare, B. W. Giambattista, R. F. Kwasnick, J. Liu, S. J. Lubowski, G. E. Possin, J. F. Richotte, C. Y. Wei, and R. F. Wirth, " Digital tomosynthesis in breast imaging.," Radiology 205, 399-406 (1997).
-
(1997)
Radiology
, vol.205
, pp. 399-406
-
-
Niklason, L.T.1
Christian, B.T.2
Niklason, L.E.3
Kopans, D.B.4
Castleberry, D.E.5
Opsahl-Ong, B.H.6
Landberg, C.E.7
Slanetz, P.J.8
Giardino, A.A.9
Moore, R.10
Albagli, D.11
Dejule, M.C.12
Fitzgerald, P.F.13
Fobare, D.F.14
Giambattista, B.W.15
Kwasnick, R.F.16
Liu, J.17
Lubowski, S.J.18
Possin, G.E.19
Richotte, J.F.20
Wei, C.Y.21
Wirth, R.F.22
more..
-
126
-
-
33845927292
-
Computation of the glandular radiation dose in digital tomosynthesis of the breast
-
I. Sechopoulos, S. Suryanarayanan, S. Vedantham, C. D'Orsi, and A. Karellas, " Computation of the glandular radiation dose in digital tomosynthesis of the breast.," Med. Phys. 34, 221-232 (2007).
-
(2007)
Med. Phys.
, vol.34
, pp. 221-232
-
-
Sechopoulos, I.1
Suryanarayanan, S.2
Vedantham, S.3
D'Orsi, C.4
Karellas, A.5
-
127
-
-
0029087574
-
Normalized average glandular dose in magnification mammography
-
B. Liu, M. Goodsitt, and H. P. Chan, " Normalized average glandular dose in magnification mammography.," Radiology 197, 27-32 (1995).
-
(1995)
Radiology
, vol.197
, pp. 27-32
-
-
Liu, B.1
Goodsitt, M.2
Chan, H.P.3
-
128
-
-
24344468790
-
Breast dose from magnification films in mammography
-
J. Law, " Breast dose from magnification films in mammography.," Br. J. Radiol. 78, 816-820 (2005).
-
(2005)
Br. J. Radiol.
, vol.78
, pp. 816-820
-
-
Law, J.1
-
129
-
-
33751199672
-
Monte Carlo generated conversion factors for the estimation of average glandular dose in contact and magnification mammography
-
M. Koutalonis, H. Delis, G. Spyrou, L. Costaridou, G. Tzanakos, and G. Panayiotakis, " Monte Carlo generated conversion factors for the estimation of average glandular dose in contact and magnification mammography.," Phys. Med. Biol. 51, 5539-5548 (2006).
-
(2006)
Phys. Med. Biol.
, vol.51
, pp. 5539-5548
-
-
Koutalonis, M.1
Delis, H.2
Spyrou, G.3
Costaridou, L.4
Tzanakos, G.5
Panayiotakis, G.6
-
130
-
-
0021811673
-
Dual-energy mammography: Initial experimental results
-
P. C. Johns, D. J. Drost, M. J. Yaffe, and A. Fenster, " Dual-energy mammography: Initial experimental results.," Med. Phys. 12, 297-304 (1985).
-
(1985)
Med. Phys.
, vol.12
, pp. 297-304
-
-
Johns, P.C.1
Drost, D.J.2
Yaffe, M.J.3
Fenster, A.4
-
131
-
-
0021828887
-
Theoretical optimization of dual-energy x-ray imaging with application to mammography
-
P. C. Johns and M. J. Yaffe, " Theoretical optimization of dual-energy x-ray imaging with application to mammography.," Med. Phys. 12, 289-296 (1985).
-
(1985)
Med. Phys.
, vol.12
, pp. 289-296
-
-
Johns, P.C.1
Yaffe, M.J.2
-
132
-
-
0032886446
-
Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment
-
J. M. Boone, " Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment.," Radiology 213, 23-37 (1999).
-
(1999)
Radiology
, vol.213
, pp. 23-37
-
-
Boone, J.M.1
-
133
-
-
35648976045
-
Dual-energy approach to contrast-enhanced mammography using the balanced filter method: Spectral optimization and preliminary phantom measurement
-
M. Saito, " Dual-energy approach to contrast-enhanced mammography using the balanced filter method: Spectral optimization and preliminary phantom measurement.," Med. Phys. 34, 4236-4246 (2007).
-
(2007)
Med. Phys.
, vol.34
, pp. 4236-4246
-
-
Saito, M.1
-
134
-
-
11144294754
-
Monochromatic x-rays in digital mammography
-
R. Lawaczeck, V. Arkadiev, F. Diekmann, and M. Krumrey, " Monochromatic x-rays in digital mammography.," Invest. Radiol. 40, 33-39 (2005).
-
(2005)
Invest. Radiol.
, vol.40
, pp. 33-39
-
-
Lawaczeck, R.1
Arkadiev, V.2
Diekmann, F.3
Krumrey, M.4
-
135
-
-
33747624426
-
Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography
-
P. Baldelli, A. Bravin, M. C. Di, G. Gennaro, A. Sarnelli, A. Taibi, and M. Gambaccini, " Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography.," Phys. Med. Biol. 51, 4233-4251 (2006).
-
(2006)
Phys. Med. Biol.
, vol.51
, pp. 4233-4251
-
-
Baldelli, P.1
Bravin, A.2
Di, M.C.3
Gennaro, G.4
Sarnelli, A.5
Taibi, A.6
Gambaccini, M.7
-
136
-
-
0033778183
-
Estimation of mean glandular dose for mammography of augmented breasts
-
J. R. Beckett and C. J. Kotre, " Estimation of mean glandular dose for mammography of augmented breasts.," Phys. Med. Biol. 45, 3241-3252 (2000).
-
(2000)
Phys. Med. Biol.
, vol.45
, pp. 3241-3252
-
-
Beckett, J.R.1
Kotre, C.J.2
-
137
-
-
34247632022
-
Radiation dose reduction for augmentation mammography
-
R. L. Smathers, J. M. Boone, L. J. Lee, E. A. Berns, R. A. Miller, and A. M. Wright, " Radiation dose reduction for augmentation mammography.," AJR, Am. J. Roentgenol. 188, 1414-1421 (2007).
-
(2007)
AJR, Am. J. Roentgenol.
, vol.188
, pp. 1414-1421
-
-
Smathers, R.L.1
Boone, J.M.2
Lee, L.J.3
Berns, E.A.4
Miller, R.A.5
Wright, A.M.6
-
138
-
-
42449130947
-
Monte Carlo and phantom study of the radiation dose to the body from dedicated CT of the breast
-
I. Sechopoulos, S. Vedantham, S. Suryanarayanan, C. J. D'Orsi, and A. Karellas, " Monte Carlo and phantom study of the radiation dose to the body from dedicated CT of the breast.," Radiology 247 (1), 98-105 (2008).
-
(2008)
Radiology
, vol.247
, Issue.1
, pp. 98-105
-
-
Sechopoulos, I.1
Vedantham, S.2
Suryanarayanan, S.3
D'Orsi, C.J.4
Karellas, A.5
-
139
-
-
0017877886
-
A film dosimetry system for use in computed tomography
-
R. L. Dixon and K. E. Ekstrand, " A film dosimetry system for use in computed tomography.," Radiology 127, 255-258 (1978).
-
(1978)
Radiology
, vol.127
, pp. 255-258
-
-
Dixon, R.L.1
Ekstrand, K.E.2
-
140
-
-
0028147743
-
The measurement of radiation dose profiles for electron-beam computed tomography using film dosimetry
-
F. E. Zink and C. H. McCollough, " The measurement of radiation dose profiles for electron-beam computed tomography using film dosimetry.," Med. Phys. 21, 1287-1291 (1994).
-
(1994)
Med. Phys.
, vol.21
, pp. 1287-1291
-
-
Zink, F.E.1
McCollough, C.H.2
-
141
-
-
17844396202
-
The calibration of experimental self-developing Gafchromic HXR film for the measurement of radiation dose in computed tomography
-
K. R. Gorny, M. R. Bruesewitz, J. M. Kofler, N. J. Hangiandreou, and C. H. McCollough, " The calibration of experimental self-developing Gafchromic HXR film for the measurement of radiation dose in computed tomography.," Med. Phys. 32, 1010-1016 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 1010-1016
-
-
Gorny, K.R.1
Bruesewitz, M.R.2
Kofler, J.M.3
Hangiandreou, N.J.4
McCollough, C.H.5
-
142
-
-
21144437851
-
A preliminary study of the novel application of normoxic polymer gel dosimeters for the measurement of CTDI on diagnostic x-ray CT scanners
-
B. Hill, A. J. Venning, and C. Baldock, " A preliminary study of the novel application of normoxic polymer gel dosimeters for the measurement of CTDI on diagnostic x-ray CT scanners.," Med. Phys. 32, 1589-1597 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 1589-1597
-
-
Hill, B.1
Venning, A.J.2
Baldock, C.3
-
143
-
-
0019427221
-
CT alignment probe for the dose profile insert
-
N. J. Schneiders, S. A. Glaze, and S. C. Bushong, " CT alignment probe for the dose profile insert.," Med. Phys. 8, 398-399 (1981).
-
(1981)
Med. Phys.
, vol.8
, pp. 398-399
-
-
Schneiders, N.J.1
Glaze, S.A.2
Bushong, S.C.3
-
144
-
-
0041888231
-
Analyses and applications of single scan dose profiles in computed tomography
-
H. Y. Tsai, C. J. Tung, M. H. Huang, and Y. L. Wan, " Analyses and applications of single scan dose profiles in computed tomography.," Med. Phys. 30, 1982-1989 (2003).
-
(2003)
Med. Phys.
, vol.30
, pp. 1982-1989
-
-
Tsai, H.Y.1
Tung, C.J.2
Huang, M.H.3
Wan, Y.L.4
-
145
-
-
34247606356
-
Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: Comparison with thermoluminescent dosimetry
-
T. T. Yoshizumi, " Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: Comparison with thermoluminescent dosimetry.," AJR, Am. J. Roentgenol. 188, 1332-1336 (2007).
-
(2007)
AJR, Am. J. Roentgenol.
, vol.188
, pp. 1332-1336
-
-
Yoshizumi, T.T.1
-
146
-
-
0018074741
-
Use of a pencil-shaped ionization chamber for measurement of exposure resulting from a computed tomography scan
-
A. Suzuki and M. N. Suzuki, " Use of a pencil-shaped ionization chamber for measurement of exposure resulting from a computed tomography scan.," Med. Phys. 5, 536-539 (1978).
-
(1978)
Med. Phys.
, vol.5
, pp. 536-539
-
-
Suzuki, A.1
Suzuki, M.N.2
-
147
-
-
0019388095
-
Multisegmented ion chamber for CT scanner dosimetry
-
M. M. Moore, R. K. Cacak, and W. R. Hendee, " Multisegmented ion chamber for CT scanner dosimetry.," Med. Phys. 8, 640-645 (1981).
-
(1981)
Med. Phys.
, vol.8
, pp. 640-645
-
-
Moore, M.M.1
Cacak, R.K.2
Hendee, W.R.3
-
149
-
-
0032742081
-
Dose reduction in CT by anatomically adapted tube current modulation: II. Phantom measurement
-
W. A. Kalender, H. Wolf, and C. Suess, " Dose reduction in CT by anatomically adapted tube current modulation: II. Phantom measurement.," Med. Phys. 26, 2248-2253 (1999).
-
(1999)
Med. Phys.
, vol.26
, pp. 2248-2253
-
-
Kalender, W.A.1
Wolf, H.2
Suess, C.3
-
150
-
-
23944488753
-
Patient radiation doses for electron beam CT
-
I. A. Castellano, D. R. Dance, C. L. Skinner, and P. M. Evans, " Patient radiation doses for electron beam CT.," Med. Phys. 32, 2517-2527 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 2517-2527
-
-
Castellano, I.A.1
Dance, D.R.2
Skinner, C.L.3
Evans, P.M.4
-
151
-
-
85027221705
-
-
http://www.impactscan.org/ctdosimetry.htm
-
-
-
-
152
-
-
34249087431
-
Estimating radiation doses from multidetector CT using Monte Carlo simulations: Effects of different size voxelized patient models on magnitudes of organ and effective dose
-
J. J. DeMarco, " Estimating radiation doses from multidetector CT using Monte Carlo simulations: Effects of different size voxelized patient models on magnitudes of organ and effective dose.," Phys. Med. Biol. 52, 2583-2597 (2007).
-
(2007)
Phys. Med. Biol.
, vol.52
, pp. 2583-2597
-
-
Demarco, J.J.1
-
153
-
-
0020576685
-
A Monte Carlo model for absorbed dose calculations in computed tomography
-
J. W. Beck, W. L. Dunn, and F. O'Foghludha, " A Monte Carlo model for absorbed dose calculations in computed tomography.," Med. Phys. 10, 314-320 (1983).
-
(1983)
Med. Phys.
, vol.10
, pp. 314-320
-
-
Beck, J.W.1
Dunn, W.L.2
O'Foghludha, F.3
-
154
-
-
0033752732
-
Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume
-
J. M. Boone, V. N. Cooper III, W. R. Nemzek, J. P. McGahan, and J. A. Seibert, " Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume.," Med. Phys. 27, 2393-2407 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 2393-2407
-
-
Boone, J.M.1
Cooper III, V.N.2
Nemzek, W.R.3
McGahan, J.P.4
Seibert, J.A.5
-
155
-
-
34147107446
-
The trouble with CTD100
-
J. M. Boone, " The trouble with CTD100.," Med. Phys. 34, 1364-1371 (2007).
-
(2007)
Med. Phys.
, vol.34
, pp. 1364-1371
-
-
Boone, J.M.1
-
156
-
-
44349119806
-
Monte Carlo evaluation of CTDI in infinitely long cylinders of water, plyetheylene and PMMA with diameters from 10 mm to 500 mm
-
H. Zhou and J. M. Boone, " Monte Carlo evaluation of CTDI in infinitely long cylinders of water, plyetheylene and PMMA with diameters from 10 mm to 500 mm.," Med. Phys. 35, 2424-2431 (2008).
-
(2008)
Med. Phys.
, vol.35
, pp. 2424-2431
-
-
Zhou, H.1
Boone, J.M.2
-
157
-
-
0019485556
-
A method for describing the doses delivered by transmission x-ray computed tomography
-
T. B. Shope, R. M. Gagne, and G. C. Johnson, " A method for describing the doses delivered by transmission x-ray computed tomography.," Med. Phys. 8, 488-495 (1981).
-
(1981)
Med. Phys.
, vol.8
, pp. 488-495
-
-
Shope, T.B.1
Gagne, R.M.2
Johnson, G.C.3
-
158
-
-
0003574361
-
-
4th ed. (CTB Publications, Hamburg, Germany).
-
M. Galanski, N. Hidajat, W. Maier, H. D. Nagel, and T. Schmidt, Radiation Exposure in Computed Tomography, 4th ed. (CTB Publications, Hamburg, Germany, 2004).
-
(2004)
Radiation Exposure in Computed Tomography
-
-
Galanski, M.1
Hidajat, N.2
Maier, W.3
Nagel, H.D.4
Schmidt, T.5
-
159
-
-
0036831529
-
AAPM/RSNA physics tutorial for residents: Topics in CT. Radiation dose in CT
-
M. F. McNitt-Gray, " AAPM/RSNA physics tutorial for residents: Topics in CT. Radiation dose in CT.," Radiographics 22, 1541-1553 (2002).
-
(2002)
Radiographics
, vol.22
, pp. 1541-1553
-
-
McNitt-Gray, M.F.1
-
160
-
-
0037342616
-
Influence of phantom diameter, kVp and scan mode upon computed tomography dose index
-
E. L. Nickoloff, A. K. Dutta, and Z. F. Lu, " Influence of phantom diameter, kVp and scan mode upon computed tomography dose index.," Med. Phys. 30, 395-402 (2003).
-
(2003)
Med. Phys.
, vol.30
, pp. 395-402
-
-
Nickoloff, E.L.1
Dutta, A.K.2
Lu, Z.F.3
-
161
-
-
0028893476
-
Computed tomography dose assessment-A practical approach
-
W. Leitz, B. Axelsson, and G. Szendro, " Computed tomography dose assessment-A practical approach.," Radiat. Prot. Dosim. 57, 377-380 (1995).
-
(1995)
Radiat. Prot. Dosim.
, vol.57
, pp. 377-380
-
-
Leitz, W.1
Axelsson, B.2
Szendro, G.3
-
162
-
-
56749160156
-
-
International Electro-chemical Commission (IEC). International standard of IEC 60601-2-44 Ed2 Amendment 1: Medical electrical equipment-Part 2-44: Particular requirements for the safety of x-ray equipment for computed tomography.
-
International Electro-chemical Commission (IEC). International standard of IEC 60601-2-44 Ed2 Amendment 1: Medical electrical equipment-Part 2-44: Particular requirements for the safety of x-ray equipment for computed tomography (2003).
-
(2003)
-
-
-
163
-
-
33846529471
-
National survey of doses from CT in the UK
-
P. C. Shrimpton, M. C. Hillier, M. A. Lewis, and M. Dunn, " National survey of doses from CT in the UK.," Br. J. Radiol. 79, 968-980 (2006).
-
(2006)
Br. J. Radiol.
, vol.79
, pp. 968-980
-
-
Shrimpton, P.C.1
Hillier, M.C.2
Lewis, M.A.3
Dunn, M.4
-
164
-
-
51549088875
-
Converting CT dose length product (DLP) to effective dose
-
W. Huda, K. M. Ogden, and M. Khorasani, " Converting CT dose length product (DLP) to effective dose.," Radiology 248, 995-1003 (2008).
-
(2008)
Radiology
, vol.248
, pp. 995-1003
-
-
Huda, W.1
Ogden, K.M.2
Khorasani, M.3
-
165
-
-
0032915134
-
Use of the concept of energy imparted in diagnostic radiology
-
G. A. Carlsson, D. R. Dance, J. Persliden, and M. Sandborg, " Use of the concept of energy imparted in diagnostic radiology.," Appl. Radiat. Isot. 50, 39-62 (1999).
-
(1999)
Appl. Radiat. Isot.
, vol.50
, pp. 39-62
-
-
Carlsson, G.A.1
Dance, D.R.2
Persliden, J.3
Sandborg, M.4
-
166
-
-
23844544095
-
Use of energy imparted as an optimization tool in CT
-
A. I. Jonisch, W. Huda, and K. M. Ogden, " Use of energy imparted as an optimization tool in CT.," Proc. SPIE 5745, 744-753 (2005).
-
(2005)
Proc. SPIE
, vol.5745
, pp. 744-753
-
-
Jonisch, A.I.1
Huda, W.2
Ogden, K.M.3
-
167
-
-
33749372481
-
Estimation of effective doses to adult and pediatric patients from multislice computed tomography: A method based on energy imparted
-
N. Theocharopoulos, J. Damilakis, K. Perisinakis, A. Tzedakis, A. Karantanas, and N. Gourtsoyiannis, " Estimation of effective doses to adult and pediatric patients from multislice computed tomography: A method based on energy imparted.," Med. Phys. 33, 3846-3856 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 3846-3856
-
-
Theocharopoulos, N.1
Damilakis, J.2
Perisinakis, K.3
Tzedakis, A.4
Karantanas, A.5
Gourtsoyiannis, N.6
-
168
-
-
0029883007
-
Energy imparted and effective doses in computed tomography
-
J. V. Atherton and W. Huda, " Energy imparted and effective doses in computed tomography.," Med. Phys. 23, 735-741 (1996).
-
(1996)
Med. Phys.
, vol.23
, pp. 735-741
-
-
Atherton, J.V.1
Huda, W.2
-
169
-
-
0038038881
-
A new look at CT dose measurement: Beyond CTDI
-
R. L. Dixon, " A new look at CT dose measurement: Beyond CTDI.," Med. Phys. 30, 1272-1280 (2003).
-
(2003)
Med. Phys.
, vol.30
, pp. 1272-1280
-
-
Dixon, R.L.1
-
170
-
-
12844262152
-
Novel methods of measuring single scan dose profiles and cumulative dose in CT
-
K. D. Nakonechny, B. G. Fallone, and S. Rathee, " Novel methods of measuring single scan dose profiles and cumulative dose in CT.," Med. Phys. 32, 98-109 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 98-109
-
-
Nakonechny, K.D.1
Fallone, B.G.2
Rathee, S.3
-
171
-
-
33749401161
-
Restructuring CT dosimetry-A realistic strategy for the future requiem for the pencil chamber
-
R. L. Dixon, " Restructuring CT dosimetry-A realistic strategy for the future requiem for the pencil chamber.," Med. Phys. 33, 3973-3976 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 3973-3976
-
-
Dixon, R.L.1
-
172
-
-
27244435866
-
Is it time to retire the CTDI for CT quality assurance and dose optimization?
-
D. J. Brenner, " Is it time to retire the CTDI for CT quality assurance and dose optimization? " Med. Phys. 32, 3225-3226 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 3225-3226
-
-
Brenner, D.J.1
-
173
-
-
45149119088
-
Time for unification of CT dosimetry with radiography and fluoroscopy
-
W. Huda, " Time for unification of CT dosimetry with radiography and fluoroscopy.," Radiat. Prot. Dosim. 128, 129-132 (2008).
-
(2008)
Radiat. Prot. Dosim.
, vol.128
, pp. 129-132
-
-
Huda, W.1
-
174
-
-
38049175571
-
Measuring kerma-area products (KAP) in CT
-
W. Huda and K. M. Ogden, " Measuring kerma-area products (KAP) in CT.," Med. Phys. 34, 2348-2348 (2007).
-
(2007)
Med. Phys.
, vol.34
, pp. 2348-2348
-
-
Huda, W.1
Ogden, K.M.2
-
175
-
-
0017710931
-
Physical performance and dosimetric characteristics of the delta-Scan 50 whole-body/brain scanner
-
D. A. Bassano, C. C. Chamberlain, J. M. Mozley, and S. A. Kieffer, " Physical performance and dosimetric characteristics of the delta-Scan 50 whole-body/brain scanner.," Radiology 123, 455-462 (1977).
-
(1977)
Radiology
, vol.123
, pp. 455-462
-
-
Bassano, D.A.1
Chamberlain, C.C.2
Mozley, J.M.3
Kieffer, S.A.4
-
176
-
-
0018619811
-
Effect of x-ray filtration on dose and image performance of CT scanners
-
M. Szulc and P. F. Judy, " Effect of x-ray filtration on dose and image performance of CT scanners.," Med. Phys. 6, 479-486 (1979).
-
(1979)
Med. Phys.
, vol.6
, pp. 479-486
-
-
Szulc, M.1
Judy, P.F.2
-
177
-
-
0019522330
-
CT scanner comparison
-
F. C. Southon, " CT scanner comparison.," Med. Phys. 8, 62-75 (1981).
-
(1981)
Med. Phys.
, vol.8
, pp. 62-75
-
-
Southon, F.C.1
-
178
-
-
0021257942
-
Image quality and dose in computerized tomography: Evaluation of four CT scanners
-
G. Borasi, " Image quality and dose in computerized tomography: Evaluation of four CT scanners.," Med. Phys. 11, 321-325 (1984).
-
(1984)
Med. Phys.
, vol.11
, pp. 321-325
-
-
Borasi, G.1
-
179
-
-
0020042894
-
Computed tomographic scanning in children: II. An updated comparison of radiation dose and resolving power of commercial scanners
-
R. C. Brasch and C. E. Cann, " Computed tomographic scanning in children: II. An updated comparison of radiation dose and resolving power of commercial scanners.," AJR, Am. J. Roentgenol. 138, 127-133 (1982).
-
(1982)
AJR, Am. J. Roentgenol.
, vol.138
, pp. 127-133
-
-
Brasch, R.C.1
Cann, C.E.2
-
180
-
-
0032718470
-
Performance evaluation of a multi-slice CT system
-
C. H. McCollough and F. E. Zink, " Performance evaluation of a multi-slice CT system.," Med. Phys. 26, 2223-2230 (1999).
-
(1999)
Med. Phys.
, vol.26
, pp. 2223-2230
-
-
McCollough, C.H.1
Zink, F.E.2
-
181
-
-
0037372750
-
Multi-detector row CT: Radiation dose characteristics
-
L. M. Hamberg, J. T. Rhea, G. J. Hunter, and J. H. Thrall, " Multi-detector row CT: Radiation dose characteristics.," Radiology 226, 762-772 (2003).
-
(2003)
Radiology
, vol.226
, pp. 762-772
-
-
Hamberg, L.M.1
Rhea, J.T.2
Hunter, G.J.3
Thrall, J.H.4
-
182
-
-
36749064349
-
Comparison of MDCT radiation dose: A phantom study
-
W. H. Moore, M. Bonvento, and R. Olivieri-Fitt, " Comparison of MDCT radiation dose: A phantom study.," AJR, Am. J. Roentgenol. 187, 498-502 (2006).
-
(2006)
AJR, Am. J. Roentgenol.
, vol.187
, pp. 498-502
-
-
Moore, W.H.1
Bonvento, M.2
Olivieri-Fitt, R.3
-
183
-
-
34249023378
-
Dose performance of a 64-channel dual-source CT scanner
-
C. H. McCollough, " Dose performance of a 64-channel dual-source CT scanner.," Radiology 243, 775-784 (2007).
-
(2007)
Radiology
, vol.243
, pp. 775-784
-
-
McCollough, C.H.1
-
184
-
-
3042661990
-
Physical performance evaluation of a 256-slice CT-scanner for four-dimensional imaging
-
S. Mori, " Physical performance evaluation of a 256-slice CT-scanner for four-dimensional imaging.," Med. Phys. 31, 1348-1356 (2004).
-
(2004)
Med. Phys.
, vol.31
, pp. 1348-1356
-
-
Mori, S.1
-
185
-
-
4644258645
-
The phantom portion of the American College of Radiology (ACR) computed tomography (CT) accreditation program: Practical tips, artifact examples, and pitfalls to avoid
-
C. H. McCollough, " The phantom portion of the American College of Radiology (ACR) computed tomography (CT) accreditation program: Practical tips, artifact examples, and pitfalls to avoid.," Med. Phys. 31, 2423-2442 (2004).
-
(2004)
Med. Phys.
, vol.31
, pp. 2423-2442
-
-
McCollough, C.H.1
-
187
-
-
34347388838
-
16-slice CT: Achievable effective doses of common protocols in comparison with recent CT dose surveys
-
A. J. Van der Molen, W. J. Veldkamp, and J. Geleijns, " 16-slice CT: Achievable effective doses of common protocols in comparison with recent CT dose surveys.," Br. J. Radiol. 80, 248-255 (2007).
-
(2007)
Br. J. Radiol.
, vol.80
, pp. 248-255
-
-
Van Der Molen, A.J.1
Veldkamp, W.J.2
Geleijns, J.3
-
188
-
-
21144440833
-
The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations
-
A. Tzedakis, J. Damilakis, K. Perisinakis, J. Stratakis, and N. Gourtsoyiannis, " The effect of z overscanning on patient effective dose
-
(2005)
Med. Phys.
, vol.32
, pp. 1621-1629
-
-
Tzedakis, A.1
Damilakis, J.2
Perisinakis, K.3
Stratakis, J.4
Gourtsoyiannis, N.5
-
189
-
-
34147097370
-
Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations
-
A. Tzedakis, J. Damilakis, K. Perisinakis, A. Karantanas, S. Karabekios, and N. Gourtsoyiannis, " Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations.," Med. Phys. 34, 1163-1175 (2007).
-
(2007)
Med. Phys.
, vol.34
, pp. 1163-1175
-
-
Tzedakis, A.1
Damilakis, J.2
Perisinakis, K.3
Karantanas, A.4
Karabekios, S.5
Gourtsoyiannis, N.6
-
190
-
-
0032744531
-
Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies
-
M. Gies, W. A. Kalender, H. Wolf, and C. Suess, " Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies.," Med. Phys. 26, 2235-2247 (1999).
-
(1999)
Med. Phys.
, vol.26
, pp. 2235-2247
-
-
Gies, M.1
Kalender, W.A.2
Wolf, H.3
Suess, C.4
-
191
-
-
25144433343
-
Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: Clinical evaluation
-
T. H. Mulkens, " Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: Clinical evaluation.," Radiology 237, 213-223 (2005).
-
(2005)
Radiology
, vol.237
, pp. 213-223
-
-
Mulkens, T.H.1
-
192
-
-
0028041033
-
Radiation dosimetry for electron beam CT
-
C. H. McCollough, F. E. Zink, and R. L. Morin, " Radiation dosimetry for electron beam CT.," Radiology 192, 637-643 (1994).
-
(1994)
Radiology
, vol.192
, pp. 637-643
-
-
McCollough, C.H.1
Zink, F.E.2
Morin, R.L.3
-
193
-
-
0032849473
-
CT fluoroscopy-guided abdominal interventions: Techniques, results, and radiation exposure
-
S. G. Silverman, K. Tuncali, D. F. Adams, R. D. Nawfel, K. H. Zou, and P. F. Judy, " CT fluoroscopy-guided abdominal interventions: Techniques, results, and radiation exposure.," Radiology 212, 673-681 (1999).
-
(1999)
Radiology
, vol.212
, pp. 673-681
-
-
Silverman, S.G.1
Tuncali, K.2
Adams, D.F.3
Nawfel, R.D.4
Zou, K.H.5
Judy, P.F.6
-
194
-
-
0033942994
-
Patient and personnel exposure during CT fluoroscopy-guided interventional procedures
-
R. D. Nawfel, P. F. Judy, S. G. Silverman, S. Hooton, K. Tuncali, and D. F. Adams, " Patient and personnel exposure during CT fluoroscopy-guided interventional procedures.," Radiology 216, 180-184 (2000).
-
(2000)
Radiology
, vol.216
, pp. 180-184
-
-
Nawfel, R.D.1
Judy, P.F.2
Silverman, S.G.3
Hooton, S.4
Tuncali, K.5
Adams, D.F.6
-
195
-
-
0035190741
-
Dedicated breast CT: Radiation dose and image quality evaluation
-
J. M. Boone, T. R. Nelson, K. K. Lindfors, and J. A. Seibert, " Dedicated breast CT: Radiation dose and image quality evaluation.," Radiology 221, 657-667 (2001).
-
(2001)
Radiology
, vol.221
, pp. 657-667
-
-
Boone, J.M.1
Nelson, T.R.2
Lindfors, K.K.3
Seibert, J.A.4
-
196
-
-
33645000127
-
Technique factors and their relationship to radiation dose in pendant geometry breast CT
-
J. M. Boone, A. L. Kwan, J. A. Seibert, N. Shah, K. K. Lindfors, and T. R. Nelson, " Technique factors and their relationship to radiation dose in pendant geometry breast CT.," Med. Phys. 32, 3767-3776 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 3767-3776
-
-
Boone, J.M.1
Kwan, A.L.2
Seibert, J.A.3
Shah, N.4
Lindfors, K.K.5
Nelson, T.R.6
-
197
-
-
1242316319
-
A comprehensive analysis of DgN(CT) coefficients for pendant-geometry cone-beam breast computed tomography
-
J. M. Boone, N. Shah, and T. R. Nelson, " A comprehensive analysis of DgN(CT) coefficients for pendant-geometry cone-beam breast computed tomography.," Med. Phys. 31, 226-235 (2004).
-
(2004)
Med. Phys.
, vol.31
, pp. 226-235
-
-
Boone, J.M.1
Shah, N.2
Nelson, T.R.3
-
198
-
-
33845328849
-
Dose and image quality for a cone-beam C-arm CT system
-
R. Fahrig, R. Dixon, T. Payne, R. L. Morin, A. Ganguly, and N. Strobel, " Dose and image quality for a cone-beam C-arm CT system.," Med. Phys. 33, 4541-4550 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 4541-4550
-
-
Fahrig, R.1
Dixon, R.2
Payne, T.3
Morin, R.L.4
Ganguly, A.5
Strobel, N.6
-
199
-
-
0018082396
-
A study of the dose to the thyroid and the eye in computed tomography of the brain
-
D. E. Raeside, D. W. Anderson, and D. C. Galloway, " A study of the dose to the thyroid and the eye in computed tomography of the brain.," Radiology 129, 814-815 (1978).
-
(1978)
Radiology
, vol.129
, pp. 814-815
-
-
Raeside, D.E.1
Anderson, D.W.2
Galloway, D.C.3
-
200
-
-
0018131461
-
Patient dosage in computed tomography
-
E. C. McCullough and J. T. Payne, " Patient dosage in computed tomography.," Radiology 129, 457-463 (1978).
-
(1978)
Radiology
, vol.129
, pp. 457-463
-
-
McCullough, E.C.1
Payne, J.T.2
-
201
-
-
33644843754
-
Female breast radiation exposure during CT pulmonary angiography
-
M. S. Parker, F. K. Hui, M. A. Camacho, J. K. Chung, D. W. Broga, and N. N. Sethi, " Female breast radiation exposure during CT pulmonary angiography.," AJR, Am. J. Roentgenol. 185, 1228-1233 (2005).
-
(2005)
AJR, Am. J. Roentgenol.
, vol.185
, pp. 1228-1233
-
-
Parker, M.S.1
Hui, F.K.2
Camacho, M.A.3
Chung, J.K.4
Broga, D.W.5
Sethi, N.N.6
-
202
-
-
36249002355
-
Radiation dose from contemporary cardiothoracic multidetector CT protocols with an anthropomorphic female phantom: Implications for cancer induction
-
L. M. Hurwitz, " Radiation dose from contemporary cardiothoracic multidetector CT protocols with an anthropomorphic female phantom: Implications for cancer induction.," Radiology 245, 742-750 (2007).
-
(2007)
Radiology
, vol.245
, pp. 742-750
-
-
Hurwitz, L.M.1
-
203
-
-
0036156489
-
Urinary tract abnormalities: Initial experience with multi-detector row CT urography
-
E. M. Caoili, " Urinary tract abnormalities: Initial experience with multi-detector row CT urography.," Radiology 222, 353-360 (2002).
-
(2002)
Radiology
, vol.222
, pp. 353-360
-
-
Caoili, E.M.1
-
204
-
-
0036892002
-
Multi-detector row CT urography: Comparison of strategies for depicting the normal urinary collecting system
-
J. D. McTavish, " Multi-detector row CT urography: Comparison of strategies for depicting the normal urinary collecting system.," Radiology 225, 783-790 (2002).
-
(2002)
Radiology
, vol.225
, pp. 783-790
-
-
McTavish, J.D.1
-
205
-
-
2942755835
-
Patient radiation dose at CT urography and conventional urography
-
R. D. Nawfel, P. F. Judy, A. R. Schleipman, and S. G. Silverman, " Patient radiation dose at CT urography and conventional urography.," Radiology 232, 126-132 (2004).
-
(2004)
Radiology
, vol.232
, pp. 126-132
-
-
Nawfel, R.D.1
Judy, P.F.2
Schleipman, A.R.3
Silverman, S.G.4
-
206
-
-
33947688154
-
Comparison of effective radiation doses in patients undergoing unenhanced MDCT and excretory urography for acute flank pain
-
E. N. Eikefjord, F. Thorsen, and J. Rorvik, " Comparison of effective radiation doses in patients undergoing unenhanced MDCT and excretory urography for acute flank pain.," AJR, Am. J. Roentgenol. 188, 934-939 (2007).
-
(2007)
AJR, Am. J. Roentgenol.
, vol.188
, pp. 934-939
-
-
Eikefjord, E.N.1
Thorsen, F.2
Rorvik, J.3
-
207
-
-
35649009454
-
Radiation doses from small-bowel follow-through and abdominopelvic MDCT in Crohn's disease
-
T. A. Jaffe, " Radiation doses from small-bowel follow-through and abdominopelvic MDCT in Crohn's disease.," AJR, Am. J. Roentgenol. 189, 1015-1022 (2007).
-
(2007)
AJR, Am. J. Roentgenol.
, vol.189
, pp. 1015-1022
-
-
Jaffe, T.A.1
-
208
-
-
27744466794
-
Automatic exposure control in CT: Are we done yet?
-
C. H. McCollough, " Automatic exposure control in CT: Are we done yet?," Radiology 237, 755-756 (2005).
-
(2005)
Radiology
, vol.237
, pp. 755-756
-
-
McCollough, C.H.1
-
209
-
-
38049107760
-
Comparison of head and body organ doses in CT
-
W. Huda and K. M. Ogden, " Comparison of head and body organ doses in CT.," Phys. Med. Biol. 53, N9-N14 (2008).
-
(2008)
Phys. Med. Biol.
, vol.53
-
-
Huda, W.1
Ogden, K.M.2
-
210
-
-
0035086634
-
Radiation doses in infants and adults undergoing head CT examinations
-
W. Huda, C. C. Chamberlain, A. E. Rosenbaum, and W. Garrisi, " Radiation doses in infants and adults undergoing head CT examinations.," Med. Phys. 28, 393-399 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 393-399
-
-
Huda, W.1
Chamberlain, C.C.2
Rosenbaum, A.E.3
Garrisi, W.4
-
211
-
-
33747620740
-
Dose reduction in CT while maintaining diagnostic confidence: Diagnostic reference levels at routine head, chest and abdominal CT-IAEA-coordinated research project
-
V. Tsapaki, " Dose reduction in CT while maintaining diagnostic confidence: Diagnostic reference levels at routine head, chest and abdominal CT-IAEA-coordinated research project.," Radiology 240, 828-834 (2006).
-
(2006)
Radiology
, vol.240
, pp. 828-834
-
-
Tsapaki, V.1
-
212
-
-
0010210231
-
-
[United Nations Scientific Committee on the Effects of Atomic Radiation (UNSEAR), New York,].
-
UNSEAR 2000. Sources and Effects of Ionizing Radiation [United Nations Scientific Committee on the Effects of Atomic Radiation (UNSEAR), New York, 2000].
-
(2000)
UNSEAR 2000. Sources and Effects of Ionizing Radiation
-
-
-
213
-
-
0034037495
-
Effective doses in patients undergoing thoracic computed tomography examinations
-
W. Huda, E. M. Scalzetti, and M. Roskopf, " Effective doses in patients undergoing thoracic computed tomography examinations.," Med. Phys. 27, 838-844 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 838-844
-
-
Huda, W.1
Scalzetti, E.M.2
Roskopf, M.3
-
214
-
-
0033008479
-
Radiation effective doses to patients undergoing abdominal CT examination
-
D. E. Ware, W. Huda, P. J. Mergo, and A. L. Litwiller, " Radiation effective doses to patients undergoing abdominal CT examination.," Radiology 210, 645-650 (1999).
-
(1999)
Radiology
, vol.210
, pp. 645-650
-
-
Ware, D.E.1
Huda, W.2
Mergo, P.J.3
Litwiller, A.L.4
-
215
-
-
33846471867
-
Patient doses in adult and pediatric CT
-
W. Huda and A. Vance, " Patient doses in adult and pediatric CT.," AJR, Am. J. Roentgenol. 188, 540-546 (2007).
-
(2007)
AJR, Am. J. Roentgenol.
, vol.188
, pp. 540-546
-
-
Huda, W.1
Vance, A.2
-
216
-
-
0034529475
-
CT scanning: Patterns of use and dose
-
F. A. Mettler, P. W. Wiest, J. A. Locken, and C. A. Kelsey, " CT scanning: Patterns of use and dose.," J. Radiol. Prot. 20, 353-359 (2000).
-
(2000)
J. Radiol. Prot.
, vol.20
, pp. 353-359
-
-
Mettler, F.A.1
Wiest, P.W.2
Locken, J.A.3
Kelsey, C.A.4
-
217
-
-
0023096910
-
Average radiation doses in a standard head examination for 250 CT system
-
J. L. McCrohan, J. F. Patterson, R. M. Gagne, and H. A. Goldstein, " Average radiation doses in a standard head examination for 250 CT system.," Radiology 163, 263-268 (1987).
-
(1987)
Radiology
, vol.163
, pp. 263-268
-
-
McCrohan, J.L.1
Patterson, J.F.2
Gagne, R.M.3
Goldstein, H.A.4
-
218
-
-
0026694643
-
Average radiation dose in standard CT examinations of the head: Results of the 1990 NEXT survey
-
B. J. Conway, J. L. McCrohan, R. G. Antonsen, F. G. Rueter, R. J. Slayton, and O. H. Suleiman, " Average radiation dose in standard CT examinations of the head: Results of the 1990 NEXT survey.," Radiology 184, 135-140 (1992).
-
(1992)
Radiology
, vol.184
, pp. 135-140
-
-
Conway, B.J.1
McCrohan, J.L.2
Antonsen, R.G.3
Rueter, F.G.4
Slayton, R.J.5
Suleiman, O.H.6
-
219
-
-
34147106919
-
Survey of computed tomography scanners in Taiwan: Dose descriptors, dose guidance levels, and effective doses
-
H. Y. Tsai, C. J. Tung, C. C. Yu, and Y. S. Tyan, " Survey of computed tomography scanners in Taiwan: Dose descriptors, dose guidance levels, and effective doses.," Med. Phys. 34, 1234-1243 (2007).
-
(2007)
Med. Phys.
, vol.34
, pp. 1234-1243
-
-
Tsai, H.Y.1
Tung, C.J.2
Yu, C.C.3
Tyan, Y.S.4
-
220
-
-
0030959607
-
An approach for the estimation of effective radiation dose at CT in pediatric patients
-
W. Huda, J. V. Atherton, D. E. Ware, and W. A. Cumming, " An approach for the estimation of effective radiation dose at CT in pediatric patients.," Radiology 203, 417-422 (1997).
-
(1997)
Radiology
, vol.203
, pp. 417-422
-
-
Huda, W.1
Atherton, J.V.2
Ware, D.E.3
Cumming, W.A.4
-
221
-
-
0035113133
-
On the use of pediatric phantoms in the dose evaluation during computed tomography (CT) thorax examinations
-
G. Giacco, V. Cannata, C. Furetta, F. Santopietro, and G. Fariello, " On the use of pediatric phantoms in the dose evaluation during computed tomography (CT) thorax examinations.," Med. Phys. 28, 199-204 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 199-204
-
-
Giacco, G.1
Cannata, V.2
Furetta, C.3
Santopietro, F.4
Fariello, G.5
-
222
-
-
0036145023
-
Effective dose in paediatric computed tomography
-
C. L. Chapple, S. Willis, and J. Frame, " Effective dose in paediatric computed tomography.," Phys. Med. Biol. 47, 107-115 (2002).
-
(2002)
Phys. Med. Biol.
, vol.47
, pp. 107-115
-
-
Chapple, C.L.1
Willis, S.2
Frame, J.3
-
223
-
-
0036773816
-
Influence of patient age on normalized effective doses calculated for CT examinations
-
A. Khursheed, M. C. Hillier, P. C. Shrimpton, and B. F. Wall, " Influence of patient age on normalized effective doses calculated for CT examinations.," Br. J. Radiol. 75, 819-830 (2002).
-
(2002)
Br. J. Radiol.
, vol.75
, pp. 819-830
-
-
Khursheed, A.1
Hillier, M.C.2
Shrimpton, P.C.3
Wall, B.F.4
-
224
-
-
31844431612
-
The UF series of tomographic computational phantoms of pediatric patients
-
A. Lee, J. L. Williams, C. Lee, and W. E. Bolch, " The UF series of tomographic computational phantoms of pediatric patients.," Med. Phys. 32, 3537-3548 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 3537-3548
-
-
Lee, A.1
Williams, J.L.2
Lee, C.3
Bolch, W.E.4
-
225
-
-
34247636280
-
Organ and effective doses in pediatric patients undergoing helical multislice computed tomography examination
-
A. Lee, " Organ and effective doses in pediatric patients undergoing helical multislice computed tomography examination.," Med. Phys. 34, 1858-1873 (2007).
-
(2007)
Med. Phys.
, vol.34
, pp. 1858-1873
-
-
Lee, A.1
-
226
-
-
0023097495
-
Normalized pediatric organ-absorbed doses from CT examinations
-
T. Fearon and J. Vucich, " Normalized pediatric organ-absorbed doses from CT examinations.," AJR, Am. J. Roentgenol. 148, 171-174 (1987).
-
(1987)
AJR, Am. J. Roentgenol.
, vol.148
, pp. 171-174
-
-
Fearon, T.1
Vucich, J.2
-
227
-
-
1642417360
-
Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation doses
-
W. Huda, K. A. Lieberman, J. Chang, and M. L. Roskopf, " Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation doses.." Med. Phys. 31, 588-594 (2004).
-
(2004)
Med. Phys.
, vol.31
, pp. 588-594
-
-
Huda, W.1
Lieberman, K.A.2
Chang, J.3
Roskopf, M.L.4
-
228
-
-
34250806587
-
Pediatric cardiac-gated CT angiography: Assessment of radiation dose
-
C. L. Hollingsworth, " Pediatric cardiac-gated CT angiography: Assessment of radiation dose.," AJR, Am. J. Roentgenol. 189, 12-18 (2007).
-
(2007)
AJR, Am. J. Roentgenol.
, vol.189
, pp. 12-18
-
-
Hollingsworth, C.L.1
-
229
-
-
19844372990
-
Comparison of effective doses for low-dose MDCT and radiographic examination of sinuses in children
-
T. H. Mulkens, C. Broers, S. Fieuws, J. L. Termote, and P. Bellnick, " Comparison of effective doses for low-dose MDCT and radiographic examination of sinuses in children.," AJR, Am. J. Roentgenol. 184, 1611-1618 (2005).
-
(2005)
AJR, Am. J. Roentgenol.
, vol.184
, pp. 1611-1618
-
-
Mulkens, T.H.1
Broers, C.2
Fieuws, S.3
Termote, J.L.4
Bellnick, P.5
-
230
-
-
40849130892
-
Computing effective doses to pediatric patients undergoing body CT examinations
-
W. Huda and K. M. Ogden, " Computing effective doses to pediatric patients undergoing body CT examinations.," Pediatr. Radiol. 38, 415-423 (2008).
-
(2008)
Pediatr. Radiol.
, vol.38
, pp. 415-423
-
-
Huda, W.1
Ogden, K.M.2
-
231
-
-
34547761744
-
Radiation exposure and pregnancy: When should we be concerned?
-
C. H. McCollough, " Radiation exposure and pregnancy: When should we be concerned? " Radiographics 27, 909-917 (2007).
-
(2007)
Radiographics
, vol.27
, pp. 909-917
-
-
McCollough, C.H.1
-
232
-
-
0036316187
-
Pulmonary embolism in pregnant patients: Fetal radiation dose with helical CT
-
H. T. Winer-Muram, J. M. Boone, H. L. Brown, S. G. Jennings, W. C. Mabie, and G. T. Lombardo, " Pulmonary embolism in pregnant patients: Fetal radiation dose with helical CT.," Radiology 224, 487-492 (2002).
-
(2002)
Radiology
, vol.224
, pp. 487-492
-
-
Winer-Muram, H.T.1
Boone, J.M.2
Brown, H.L.3
Jennings, S.G.4
Mabie, W.C.5
Lombardo, G.T.6
-
233
-
-
56749091969
-
How well do CTDI data obtained in a body phantom predict patient and embryo doses in abdominal CT?
-
W. Huda, K. M. Ogden, J. M. Boone, and E. L. Nickoloff, " How well do CTDI data obtained in a body phantom predict patient and embryo doses in abdominal CT?," Med. Phys. 33, 2004 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 2004
-
-
Huda, W.1
Ogden, K.M.2
Boone, J.M.3
Nickoloff, E.L.4
-
234
-
-
0022521805
-
Conceptus dose from two state-of-the-art CT scanners
-
L. K. Wagner, B. R. Archer, and O. F. Zeck, " Conceptus dose from two state-of-the-art CT scanners.," Radiology 159, 787-792 (1986).
-
(1986)
Radiology
, vol.159
, pp. 787-792
-
-
Wagner, L.K.1
Archer, B.R.2
Zeck, O.F.3
-
235
-
-
0024461913
-
A method for estimating embryo doses resulting from computed tomographic examinations
-
W. Panzer and M. Zankl, " A method for estimating embryo doses resulting from computed tomographic examinations.," Br. J. Radiol. 62, 936-939 (1989).
-
(1989)
Br. J. Radiol.
, vol.62
, pp. 936-939
-
-
Panzer, W.1
Zankl, M.2
-
236
-
-
0025139506
-
Estimated fetal radiation dose from multislice CT studies
-
J. P. Felmlee, J. E. Gray, M. L. Leetzow, and J. C. Price, " Estimated fetal radiation dose from multislice CT studies.," AJR, Am. J. Roentgenol. 154, 185-190 (1990).
-
(1990)
AJR, Am. J. Roentgenol.
, vol.154
, pp. 185-190
-
-
Felmlee, J.P.1
Gray, J.E.2
Leetzow, M.L.3
Price, J.C.4
-
237
-
-
0033858074
-
Estimation of fetal radiation dose from computed tomography scanning in late pregnancy: Depth-dose data from routine examinations
-
J. Damilakis, K. Perisinakis, A. Voloudaki, and N. Gourtsoyiannis, " Estimation of fetal radiation dose from computed tomography scanning in late pregnancy: Depth-dose data from routine examinations.," Invest. Radiol. 35, 527-533 (2000).
-
(2000)
Invest. Radiol.
, vol.35
, pp. 527-533
-
-
Damilakis, J.1
Perisinakis, K.2
Voloudaki, A.3
Gourtsoyiannis, N.4
-
238
-
-
4644279738
-
Development of a 30-week -pregnant female tomographic model from computed tomography (CT) images for Monte Carlo organ dose calculations
-
C. Shi and X. G. Xu, " Development of a 30-week -pregnant female tomographic model from computed tomography (CT) images for Monte Carlo organ dose calculations.," Med. Phys. 31, 2491-2497 (2004).
-
(2004)
Med. Phys.
, vol.31
, pp. 2491-2497
-
-
Shi, C.1
Xu, X.G.2
|