Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography

Author keywords

Computer modeling; Computer simulation; Mammography; X ray production; X ray spectrum

Indexed keywords

ANODES; COMPUTER SIMULATION; INTERPOLATION; MAMMOGRAPHY; MOLYBDENUM; NEUTRON EMISSION; PHOTONS; POLYNOMIALS; TUNGSTEN; X RAY PRODUCTION; X RAY SPECTROGRAPHS; X RAY TUBES;

EID: 0031466296     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598100     Document Type: Article
Times cited : (455)

References (26)
  • 1
    • 0025967743 scopus 로고
    • Spectral dependence of glandular tissue dose in screen-film mammography
    • X. Wu, G. T. Barnes, and D. M. Tucker, "Spectral dependence of glandular tissue dose in screen-film mammography," Radiology 179, 143-148 (1991).
    • (1991) Radiology , vol.179 , pp. 143-148
    • Wu, X.1    Barnes, G.T.2    Tucker, D.M.3
  • 2
    • 0028145652 scopus 로고
    • A model for optimization of spectral shape in digital mammography
    • R Fahrig and M. J. Yaffe, "A model for optimization of spectral shape in digital mammography," Med. Phys. 21, 1463-1471 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1463-1471
    • Fahrig, R.1    Yaffe, M.J.2
  • 3
    • 0028001034 scopus 로고
    • Optimization of spectral shape in digital mammography: Dependence on anode material, breast thickness, and lesion type
    • R. Fahrig and M. J. Yaffe, "Optimization of spectral shape in digital mammography: Dependence on anode material, breast thickness, and lesion type," Med. Phys. 21, 1473-1481 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1473-1481
    • Fahrig, R.1    Yaffe, M.J.2
  • 5
    • 0019174427 scopus 로고
    • Monte Carlo simulation studies of detectors used in the measurement of diagnostic x-ray spectra
    • C. S. Chen, K. Doi, C. Vyborny, H-P. Chan, and G. Holje, "Monte Carlo simulation studies of detectors used in the measurement of diagnostic x-ray spectra," Med. Phys. 7, 627-635 (1980).
    • (1980) Med. Phys. , vol.7 , pp. 627-635
    • Chen, C.S.1    Doi, K.2    Vyborny, C.3    Chan, H.-P.4    Holje, G.5
  • 6
    • 0027141897 scopus 로고
    • Dynamic range requirements in digital mammography
    • A. D. A. Maidment, R. Fahrig, and M. J. Yaffe, "Dynamic range requirements in digital mammography," Med. Phys. 20, 1621-1633 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1621-1633
    • Maidment, A.D.A.1    Fahrig, R.2    Yaffe, M.J.3
  • 7
    • 0025756532 scopus 로고
    • Semiempirical model for generating tungsten target x-ray spectra
    • D. M. Tucker, G. T. Barnes, and D P. Chakraborty, "Semiempirical model for generating tungsten target x-ray spectra," Med. Phys. 18, 211-218 (1991)
    • (1991) Med. Phys. , vol.18 , pp. 211-218
    • Tucker, D.M.1    Barnes, G.T.2    Chakraborty, D.P.3
  • 8
    • 0018399326 scopus 로고
    • Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector
    • R. Birch and M. Marshall, "Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector," Phys. Med. Biol. 24, 505-517 (1979)
    • (1979) Phys. Med. Biol. , vol.24 , pp. 505-517
    • Birch, R.1    Marshall, M.2
  • 9
    • 0023708641 scopus 로고
    • Laplace reconstruction of experimental diagnostic x-ray spectra
    • B R. Archer, T. R. Fewell, and L. K. Wagner, "Laplace reconstruction of experimental diagnostic x-ray spectra," Med. Phys. 15, 832-837 (1988).
    • (1988) Med. Phys. , vol.15 , pp. 832-837
    • Archer, B.R.1    Fewell, T.R.2    Wagner, L.K.3
  • 10
    • 0023785184 scopus 로고
    • Determination of diagnostic x-ray spectra with characteristic radiation using attenuation analysis
    • B. R Archer and L. K. Wagner, "Determination of diagnostic x-ray spectra with characteristic radiation using attenuation analysis," Med. Phys. 15, 637-641 (1988).
    • (1988) Med. Phys. , vol.15 , pp. 637-641
    • Archer, B.R.1    Wagner, L.K.2
  • 12
    • 0028576513 scopus 로고
    • A comparison of mono- and polyenergetic x-ray beam performance for radiographic and fluoroscopic imaging
    • J. M. Boone and J. A. Seibert, "A comparison of mono- and polyenergetic x-ray beam performance for radiographic and fluoroscopic imaging," Med. Phys. 21, 1853-1863 (1994)
    • (1994) Med. Phys. , vol.21 , pp. 1853-1863
    • Boone, J.M.1    Seibert, J.A.2
  • 13
    • 0027786698 scopus 로고
    • Computer model to optimise contrast in chest radiography
    • D. McLean, "Computer model to optimise contrast in chest radiography," Aust. Phys. Eng. Sci. Med. 16, 179-185 (1993).
    • (1993) Aust. Phys. Eng. Sci. Med. , vol.16 , pp. 179-185
    • McLean, D.1
  • 14
    • 0027457347 scopus 로고
    • Experimental and theoretical x-ray imaging performance comparison of iodine and lanthanide contrast agents
    • H. N. Cardinal, D. W. Holdsworth, M. Drangova, B. B. Hobbs, and A. Fenster, "Experimental and theoretical x-ray imaging performance comparison of iodine and lanthanide contrast agents," Med. Phys. 20, 15-31 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 15-31
    • Cardinal, H.N.1    Holdsworth, D.W.2    Drangova, M.3    Hobbs, B.B.4    Fenster, A.5
  • 15
    • 0023006061 scopus 로고
    • Equivalent spectra as a measure of beam quality
    • J. M. Boone, "Equivalent spectra as a measure of beam quality," Med. Phys. 13, 861-868 (1986).
    • (1986) Med. Phys. , vol.13 , pp. 861-868
    • Boone, J.M.1
  • 16
    • 0021193623 scopus 로고
    • Investigation of energy responses of germanium detectors and correction of measured spectra by means of Monte Carlo simulation
    • H-P. Chan, C. T. Chen, K. Doi, T. R Fewell, and R. E. Shuping, "Investigation of energy responses of germanium detectors and correction of measured spectra by means of Monte Carlo simulation," Radiat. Res. 99, 443-464 (1984).
    • (1984) Radiat. Res. , vol.99 , pp. 443-464
    • Chan, H.-P.1    Chen, C.T.2    Doi, K.3    Fewell, T.R.4    Shuping, R.E.5
  • 17
    • 0027462922 scopus 로고
    • Spectral estimation and contrast calculation in the design of contrast-detail test objects for radiotherapy portal imaging
    • R. M. Harrison, G. D. Lambert, and C-L. Chappie, "Spectral estimation and contrast calculation in the design of contrast-detail test objects for radiotherapy portal imaging," Phys. Med Biol. 38, 545-556 (1993).
    • (1993) Phys. Med Biol. , vol.38 , pp. 545-556
    • Harrison, R.M.1    Lambert, G.D.2    Chappie, C.-L.3
  • 18
    • 0019915909 scopus 로고
    • Simulation studies of 4-MV x-ray spectral reconstruction by numerical analysis of transmission data
    • P. H. Huang, K R. Kase, and B. E. Bjarngard, "Simulation studies of 4-MV x-ray spectral reconstruction by numerical analysis of transmission data," Med. Phys. 9, 695-702 (1982).
    • (1982) Med. Phys. , vol.9 , pp. 695-702
    • Huang, P.H.1    Kase, K.R.2    Bjarngard, B.E.3
  • 19
    • 0025759912 scopus 로고
    • Molybdenum target x-ray spectra: A Semiempirical model
    • D. M. Tucker, G. T. Barnes, and X. Wu, "Molybdenum target x-ray spectra: A Semiempirical model," Med. Phys. 18, 402-407 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 402-407
    • Tucker, D.M.1    Barnes, G.T.2    Wu, X.3
  • 20
    • 0017654625 scopus 로고
    • Photon energy distribution of some typical diagnostic x-ray beams
    • T. R. Fewell and R. E. Shuping, "Photon energy distribution of some typical diagnostic x-ray beams," Med. Phys. 4, 187-197 (1977).
    • (1977) Med. Phys. , vol.4 , pp. 187-197
    • Fewell, T.R.1    Shuping, R.E.2
  • 23
    • 85027236725 scopus 로고    scopus 로고
    • personal communication
    • T. R. Fewell (personal communication).
    • Fewell, T.R.1
  • 24
    • 0030442807 scopus 로고    scopus 로고
    • Comparison of x-ray cross sections for diagnostic and therapeutic medical physics
    • J. M. Boone and A. E Chavez, "Comparison of x-ray cross sections for diagnostic and therapeutic medical physics," Med. Phys. 23, 1997-2005 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1997-2005
    • Boone, J.M.1    Chavez, A.E.2
  • 26
    • 85027242146 scopus 로고    scopus 로고
    • See AIP Document No. E-PAPS: E-MPHYA-24-1863 for the polynomials and a short program which generates the three spectral models. E-PAPS document files may be retrieved free of charge from our FTP server or from ftp aip.org in the directory/epaps/. For further information: e-mail: paps@aip.org or fax 516-576-2223
    • See AIP Document No. E-PAPS: E-MPHYA-24-1863 for the polynomials and a short program which generates the three spectral models. E-PAPS document files may be retrieved free of charge from our FTP server (http://www.aip.org/epaps/epaps.html) or from ftp aip.org in the directory/epaps/. For further information: e-mail: paps@aip.org or fax 516-576-2223.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.