메뉴 건너뛰기




Volumn 212, Issue 3, 1999, Pages 673-681

CT fluoroscopy-guided abdominal interventions: Techniques, results, and radiation exposure

Author keywords

Abdomen, interventional procedures; Abscess, drainage; Biopsies, technology; Computed tomography (CT), guidance; Fluoroscopy, technology; Radiations, exposure to patients and personnel

Indexed keywords

ADULT; AGED; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FEMALE; FLUOROSCOPY; GASTROINTESTINAL BIOPSY; HUMAN; HUMAN TISSUE; MALE; NEEDLE BIOPSY; PRIORITY JOURNAL; RADIATION EXPOSURE;

EID: 0032849473     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.212.3.r99se36673     Document Type: Article
Times cited : (219)

References (23)
  • 1
    • 0025238434 scopus 로고
    • Interventional radiology in the chest and abdomen
    • Mueller PR, vanSonnenberg E. Interventional radiology in the chest and abdomen. N Engl J Med 1990; 322:1364-1374.
    • (1990) N Engl J Med , vol.322 , pp. 1364-1374
    • Mueller, P.R.1    VanSonnenberg, E.2
  • 2
    • 0004945891 scopus 로고
    • Initial trial with CT fluoroscopy
    • Katada K, Anno H, Koga S, et al. Initial trial with CT fluoroscopy (abstr). Radiology 1994; 190(P):662.
    • (1994) Radiology , vol.190 , Issue.P , pp. 662
    • Katada, K.1    Anno, H.2    Koga, S.3
  • 3
    • 0001296247 scopus 로고
    • Early clinical experience with real-time CT fluoroscopy
    • Katada K, Anno H, Ogura Y, et al. Early clinical experience with real-time CT fluoroscopy (abstr). Radiology 1994; 193(P):339.
    • (1994) Radiology , vol.193 , Issue.P , pp. 339
    • Katada, K.1    Anno, H.2    Ogura, Y.3
  • 4
    • 0028780417 scopus 로고
    • Development of real-time CT fluoroscopy
    • Katada K, Anno H, Takeshita G, et al. Development of real-time CT fluoroscopy. Nippon Acta Radiol 1994; 54:1172-1174.
    • (1994) Nippon Acta Radiol , vol.54 , pp. 1172-1174
    • Katada, K.1    Anno, H.2    Takeshita, G.3
  • 5
    • 0344394882 scopus 로고
    • Development and early trials of real-time CT fluoroscopy
    • Katada K, Anno H, Ogura Y, et al. Development and early trials of real-time CT fluoroscopy. Neuroradiology 1995; 37(suppl): 587-588.
    • (1995) Neuroradiology , vol.37 , Issue.SUPPL. , pp. 587-588
    • Katada, K.1    Anno, H.2    Ogura, Y.3
  • 6
    • 0344394881 scopus 로고
    • Puncture and drainage of intracranial lesions with CT: Fluoroscopic guidance
    • Katada K, Anno H, Ogura Y, Koga S, Nonomura K, Kanno T. Puncture and drainage of intracranial lesions with CT: fluoroscopic guidance (abstr). Radiology 1995; 197(P):494.
    • (1995) Radiology , vol.197 , Issue.P , pp. 494
    • Katada, K.1    Anno, H.2    Ogura, Y.3    Koga, S.4    Nonomura, K.5    Kanno, T.6
  • 7
    • 0029832236 scopus 로고    scopus 로고
    • Guidance with real-time CT fluoroscopy: Early clinical experience
    • Katada K, Kato R, Anno H, et al. Guidance with real-time CT fluoroscopy: early clinical experience. Radiology 1996; 200:851-856.
    • (1996) Radiology , vol.200 , pp. 851-856
    • Katada, K.1    Kato, R.2    Anno, H.3
  • 8
    • 0003114784 scopus 로고
    • Transthoracic needle biopsy with real-time CT fluoroscopy
    • Kato R, Katada K, Anno H, Ida Y, Suetsugu S, Koga S. Transthoracic needle biopsy with real-time CT fluoroscopy (abstr). Radiology 1995; 197(P):529.
    • (1995) Radiology , vol.197 , Issue.P , pp. 529
    • Kato, R.1    Katada, K.2    Anno, H.3    Ida, Y.4    Suetsugu, S.5    Koga, S.6
  • 9
    • 0029907832 scopus 로고    scopus 로고
    • Radiation dosimetry at CT fluoroscopy: Physician's hand dose and development of needle holders
    • Kato R, Katada K, Anno H. Radiation dosimetry at CT fluoroscopy: physician's hand dose and development of needle holders. Radiology 1996; 201:576-578.
    • (1996) Radiology , vol.201 , pp. 576-578
    • Kato, R.1    Katada, K.2    Anno, H.3
  • 10
    • 0344826437 scopus 로고    scopus 로고
    • Therapeutic percutaneous interventional procedures of the gastrointestinal tract guided by continuous CT fluoroscopy
    • Daly BD, Krebs TL, Wong-You-Cheong JJ, Hastings GS, Pais SO. Therapeutic percutaneous interventional procedures of the gastrointestinal tract guided by continuous CT fluoroscopy (abstr). Radiology 1997; 205(P):374.
    • (1997) Radiology , vol.205 , Issue.P , pp. 374
    • Daly, B.D.1    Krebs, T.L.2    Wong-You-Cheong, J.J.3    Hastings, G.S.4    Pais, S.O.5
  • 11
    • 0000537548 scopus 로고    scopus 로고
    • First 318 interventional procedures with real-time CT
    • Seibel RM, Sehnert C, Plassmann J, Schmidt AM. First 318 interventional procedures with real-time CT (abstr). Radiology 1997; 205(P):383.
    • (1997) Radiology , vol.205 , Issue.P , pp. 383
    • Seibel, R.M.1    Sehnert, C.2    Plassmann, J.3    Schmidt, A.M.4
  • 12
    • 0344826435 scopus 로고    scopus 로고
    • CT-fluoroscopy: An important technological development facilitating CT-guided interventional procedures
    • Gianfelice D, Lepanto L. CT-fluoroscopy: an important technological development facilitating CT-guided interventional procedures (abstr). AJR 1998; 170(suppl):80.
    • (1998) AJR , vol.170 , Issue.SUPPL. , pp. 80
    • Gianfelice, D.1    Lepanto, L.2
  • 13
    • 0030833584 scopus 로고    scopus 로고
    • CT-assisted transbronchial needle aspiration: Usefulness of CT fluoroscopy
    • White CS, Templeton PA, Hasday JD. CT-assisted transbronchial needle aspiration: usefulness of CT fluoroscopy. AJR 1998; 169:393-394.
    • (1998) AJR , vol.169 , pp. 393-394
    • White, C.S.1    Templeton, P.A.2    Hasday, J.D.3
  • 14
    • 0031688462 scopus 로고    scopus 로고
    • Real time CT fluoroscopy: Usefulness in thoracic drainage
    • Meyer CA, White CS, Wu J, Futterer SF, Templeton PA. Real time CT fluoroscopy: usefulness in thoracic drainage. AJR 1998; 171:1097-1101.
    • (1998) AJR , vol.171 , pp. 1097-1101
    • Meyer, C.A.1    White, C.S.2    Wu, J.3    Futterer, S.F.4    Templeton, P.A.5
  • 15
    • 0344826433 scopus 로고    scopus 로고
    • A newly-developed equipment for biopsy under CT fluoroscopy
    • Mori M, Nitta N, Murata K, Sakamoto T, Morita R. A newly-developed equipment for biopsy under CT fluoroscopy (abstr). AJR 1998; 170(suppl):128.
    • (1998) AJR , vol.170 , Issue.SUPPL. , pp. 128
    • Mori, M.1    Nitta, N.2    Murata, K.3    Sakamoto, T.4    Morita, R.5
  • 16
    • 0345348316 scopus 로고    scopus 로고
    • CT-fluoroscopic guidance of sacroiliac joint injection
    • Sonin AH, Penrod B, Owens-Brown E. CT-fluoroscopic guidance of sacroiliac joint injection (abstr). AJR 1998; 170(suppl):38.
    • (1998) AJR , vol.170 , Issue.SUPPL. , pp. 38
    • Sonin, A.H.1    Penrod, B.2    Owens-Brown, E.3
  • 17
    • 0031722605 scopus 로고    scopus 로고
    • Real-time CT-fluoroscopy for guidance of percutaneous drainage procedures
    • Froelich JJ, Saar B, Hoppe M, et al. Real-time CT-fluoroscopy for guidance of percutaneous drainage procedures. JVIR 1998; 9:735-740.
    • (1998) JVIR , vol.9 , pp. 735-740
    • Froelich, J.J.1    Saar, B.2    Hoppe, M.3
  • 18
    • 0024421838 scopus 로고
    • Guided percutaneous biopsy of intraabdominal lesions
    • Gazelle GS, Haaga JR. Guided percutaneous biopsy of intraabdominal lesions. AJR 1989; 153:929-935.
    • (1989) AJR , vol.153 , pp. 929-935
    • Gazelle, G.S.1    Haaga, J.R.2
  • 19
    • 0026482967 scopus 로고
    • Needle-tip localization during CT-guided abdominal biopsy: Comparison of conventional and spiral CT
    • Silverman SG, Bloom DA, Seltzer SE, Tempany CM, Adams DF. Needle-tip localization during CT-guided abdominal biopsy: comparison of conventional and spiral CT. AJR 1992; 159:1095-1097.
    • (1992) AJR , vol.159 , pp. 1095-1097
    • Silverman, S.G.1    Bloom, D.A.2    Seltzer, S.E.3    Tempany, C.M.4    Adams, D.F.5
  • 21
    • 0017278804 scopus 로고
    • Precise biopsy localization by computed tomography
    • Haaga JR, Alfidi RJ. Precise biopsy localization by computed tomography. Radiology 1976; 118:603-607.
    • (1976) Radiology , vol.118 , pp. 603-607
    • Haaga, J.R.1    Alfidi, R.J.2
  • 22
    • 0026595589 scopus 로고
    • A 5-y follow-up of the radiation exposure to in-room personnel during cardiac catheterization
    • Renaud L. A 5-y follow-up of the radiation exposure to in-room personnel during cardiac catheterization. Health Phys 1992; 62:10-15.
    • (1992) Health Phys , vol.62 , pp. 10-15
    • Renaud, L.1
  • 23
    • 0013326717 scopus 로고    scopus 로고
    • Dose reduction in CT by anatomically adapted tube current modulation: Experimental results and first patient studies
    • Kalender WA, Wolf H, Suess C, et al. Dose reduction in CT by anatomically adapted tube current modulation: experimental results and first patient studies (abstr). Radiology 1997; 205(P):471.
    • (1997) Radiology , vol.205 , Issue.P , pp. 471
    • Kalender, W.A.1    Wolf, H.2    Suess, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.