메뉴 건너뛰기




Volumn 114, Issue 1-3, 2005, Pages 359-363

Breast dosimetry using high-resolution voxel phantoms

Author keywords

[No Author keywords available]

Indexed keywords

ADIPOSE TISSUE; ANALYSIS OF VARIANCE; ARTICLE; BREAST DUCT; CALCULATION; COMPUTER MODEL; COMPUTER SIMULATION; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DOSIMETRY; LIGAMENT; MAMMOGRAPHY; PHANTOM; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; SKIN; THICKNESS; THREE DIMENSIONAL IMAGING;

EID: 21244447642     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nch510     Document Type: Article
Times cited : (73)

References (8)
  • 2
    • 0003684321 scopus 로고    scopus 로고
    • European protocol on dosimetry in mammography
    • European Commission. European Commission Report EUR 16263 EN (Luxembourg: EC) ISBN 92-8277289-6
    • European Commission. European protocol on dosimetry in mammography. European Commission Report EUR 16263 EN (Luxembourg: EC) (1996), ISBN 92-8277289-6.
    • (1996)
  • 3
    • 0024986312 scopus 로고
    • Monte Carlo calculation of conversion factors for the estimation of mean glandular breast dose
    • Dance, D. R. Monte Carlo calculation of conversion factors for the estimation of mean glandular breast dose. Phys. Med. Biol. 35, 1211-1219 (1990).
    • (1990) Phys. Med. Biol. , vol.35 , pp. 1211-1219
    • Dance, D.R.1
  • 4
    • 0033778108 scopus 로고    scopus 로고
    • Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol
    • Dance, D. R., Skinner, C. L., Young, K. C., Beckett, J. R. and Kotre, C. J. Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol. Phys. Med. Biol. 45, 3225-3240 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 3225-3240
    • Dance, D.R.1    Skinner, C.L.2    Young, K.C.3    Beckett, J.R.4    Kotre, C.J.5
  • 5
    • 0025967743 scopus 로고
    • Spectral dependence of glandular tissue dose in screen-film mammography
    • Wu, X., Barnes, G. T. and Tucker, D. M. Spectral dependence of glandular tissue dose in screen-film mammography. Radiology 179, 143-148 (1991).
    • (1991) Radiology , vol.179 , pp. 143-148
    • Wu, X.1    Barnes, G.T.2    Tucker, D.M.3
  • 6
    • 0027956991 scopus 로고
    • Normalized average glandular dose in molybdenum target-rhodium filter and rhodium target-rhodium filter mammography
    • Wu, X., Gingold, E. L., Barnes, G. T. and Tucker, D. M. Normalized average glandular dose in molybdenum target-rhodium filter and rhodium target-rhodium filter mammography. Radiology 193, 83-89 (1994).
    • (1994) Radiology , vol.193 , pp. 83-89
    • Wu, X.1    Gingold, E.L.2    Barnes, G.T.3    Tucker, D.M.4
  • 7
    • 0033693797 scopus 로고    scopus 로고
    • Influence of anodelfilter material and tube potential on contrast, signal-to-noise ratio and average absorbed dose in mammography: A Monte Carlo study
    • Dance, D. R., Thilander Klang, A., Sandborg, M., Skinner, C. L., Castellano-Smith, I. A. and Alm Carlsson, G. Influence of anodelfilter material and tube potential on contrast, signal-to-noise ratio and average absorbed dose in mammography: a Monte Carlo study. Br. J. Radiol. 73, 1056-1067 (2000).
    • (2000) Br. J. Radiol. , vol.73 , pp. 1056-1067
    • Dance, D.R.1    Thilander Klang, A.2    Sandborg, M.3    Skinner, C.L.4    Castellano-Smith, I.A.5    Alm Carlsson, G.6
  • 8
    • 0036734336 scopus 로고    scopus 로고
    • Mammogram synthesis using a 3D simulation. 1. Breast tissue model and image acquisition simulation
    • Bakic, P. R., Albert, M., Brzakovic, D. and Maidment, A. D. A. Mammogram synthesis using a 3D simulation. 1. Breast tissue model and image acquisition simulation. Med. Phys. 29, 2131-2139 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2131-2139
    • Bakic, P.R.1    Albert, M.2    Brzakovic, D.3    Maidment, A.D.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.