메뉴 건너뛰기




Volumn 53, Issue 2, 2008, Pages

Comparison of head and body organ doses in CT

Author keywords

[No Author keywords available]

Indexed keywords

BRAIN; DATA ACQUISITION; DOSIMETRY; IRRADIATION; NUMERICAL METHODS; SOFTWARE PACKAGES; TISSUE;

EID: 38049107760     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/53/2/N02     Document Type: Article
Times cited : (14)

References (23)
  • 2
    • 0033752732 scopus 로고    scopus 로고
    • Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume
    • Boone J M, Cooper V N, Nemzek W R, McGahan J P and Seibert J A 2000 Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume Med. Phys. 27 2393-407
    • (2000) Med. Phys. , vol.27 , Issue.10 , pp. 2393-2407
    • Boone, J.M.1    Cooper, V.N.2    Nemzek, W.R.3    McGahan, J.P.4    Seibert, J.A.5
  • 3
    • 27244435866 scopus 로고    scopus 로고
    • Is it time to retire the CTDI for CT quality assurance and dose optimization?
    • Brenner D J 2005 Is it time to retire the CTDI for CT quality assurance and dose optimization? Med. Phys. 32 3225-6
    • (2005) Med. Phys. , vol.32 , Issue.10 , pp. 3225-3226
    • Brenner, D.J.1
  • 4
    • 0036145023 scopus 로고    scopus 로고
    • Effective dose in pediatric computed tomography
    • Chapple C-L, Willis S and Frame J 2002 Effective dose in pediatric computed tomography Phys. Med. Biol. 47 107-15
    • (2002) Phys. Med. Biol. , vol.47 , Issue.1 , pp. 107-115
    • Chapple, C.-L.1    Willis, S.2    Frame, J.3
  • 5
    • 0038038881 scopus 로고    scopus 로고
    • A new look at CT dose measurement: Beyond CTDI
    • Dixon R L 2003 A new look at CT dose measurement: beyond CTDI Med. Phys. 30 1272-80
    • (2003) Med. Phys. , vol.30 , Issue.6 , pp. 1272-1280
    • Dixon, R.L.1
  • 6
    • 34547450740 scopus 로고    scopus 로고
    • Experimental validation of a versatile system of CT dosimetry using a conventional ion chamber: Beyond CTDI100
    • Dixon R L and Ballard A C 2007 Experimental validation of a versatile system of CT dosimetry using a conventional ion chamber: beyond CTDI100 Med. Phys. 34 3399-413
    • (2007) Med. Phys. , vol.34 , Issue.8 , pp. 3399-3413
    • Dixon, R.L.1    Ballard, A.C.2
  • 7
    • 45149119088 scopus 로고    scopus 로고
    • Time for unification of CT dosimetry with radiography and fluoroscopy
    • Huda W 2007 Time for unification of CT dosimetry with radiography and fluoroscopy Radiat. Prot. Dosim. doi:10.1093/rpd/ncm/431 at press
    • (2007) Radiat. Prot. Dosim.
    • Huda, W.1
  • 8
    • 0030959607 scopus 로고    scopus 로고
    • An approach for the estimation of effective radiation doses at CT in pediatric patients
    • Huda W, Atherton J V, Ware D E and Cumming W A 1997 An approach for the estimation of effective radiation doses at CT in pediatric patients Radiology 203 417-22
    • (1997) Radiology , vol.203 , Issue.2 , pp. 417-422
    • Huda, W.1    Atherton, J.V.2    Ware, D.E.3    Cumming, W.A.4
  • 9
    • 1642417360 scopus 로고    scopus 로고
    • Patient size and x-ray technique factors in head CT examinations: Part 1. Radiation dose
    • Huda W, Lieberman K A, Chang J and Roskopf M L 2004 Patient size and x-ray technique factors in head CT examinations: Part 1. Radiation dose Med. Phys. 31 588-94
    • (2004) Med. Phys. , vol.31 , Issue.3 , pp. 588-594
    • Huda, W.1    Lieberman, K.A.2    Chang, J.3    Roskopf, M.L.4
  • 10
    • 38049113904 scopus 로고    scopus 로고
    • Use of tissue air ratios to obtain organ doses in CT
    • Huda W and Ogden K M 2006 Use of tissue air ratios to obtain organ doses in CT Med. Phys. 33 2004-5 (Abstract)
    • (2006) Med. Phys. , vol.33 , Issue.6 , pp. 2004-2005
    • Huda, W.1    Ogden, K.M.2
  • 11
    • 38049175571 scopus 로고    scopus 로고
    • Measuring kerma-area products (KAP) in CT
    • Huda W and Ogden K M 2007 Measuring kerma-area products (KAP) in CT Med. Phys. 34 2348 (Abstract)
    • (2007) Med. Phys. , vol.34 , Issue.6 , pp. 2348
    • Huda, W.1    Ogden, K.M.2
  • 12
    • 0034037495 scopus 로고    scopus 로고
    • Effective doses to patients undergoing thoracic CT examinations
    • Huda W, Scalzetti E M and Roskopf M L 2000 Effective doses to patients undergoing thoracic CT examinations Med. Phys. 27 838-44
    • (2000) Med. Phys. , vol.27 , Issue.5 , pp. 838-844
    • Huda, W.1    Scalzetti, E.M.2    Roskopf, M.L.3
  • 13
    • 57649129328 scopus 로고    scopus 로고
    • International Commission on Radiological Protection (ICRP) Publication 89. Basic anatomical and physiological data for use in radiological protection: Reference values
    • ICRP 2002 International Commission on Radiological Protection (ICRP) Publication 89. Basic anatomical and physiological data for use in radiological protection: reference values Ann. ICRP 32 1-265
    • (2002) Ann. ICRP , vol.32 , Issue.3-4 , pp. 1-265
  • 14
    • 38049127743 scopus 로고    scopus 로고
    • ImPACT 2007 http://www.impactscan.org/ctdosimetry.htm
    • (2007)
    • Impact1
  • 16
    • 0003409650 scopus 로고
    • Jones D G and Shrimpton P C 1993 Normalised organ doses for x-ray computed tomography calculated using Monte Carlo techniques NRPB SR250 (Didcot, Oxon: NRPB)
    • (1993) NRPB SR250
    • Jones, D.G.1    Shrimpton, P.C.2
  • 17
    • 0036773816 scopus 로고    scopus 로고
    • Influence of patient age on normalized effective doses calculated for CT examinations
    • Khursheed A, Hillier M C, Shrimpton P C and Wall B F 2002 Influence of patient age on normalized effective doses calculated for CT examinations Br. J. Radiol. 75 819-30
    • (2002) Br. J. Radiol. , vol.75 , pp. 819-830
    • Khursheed, A.1    Hillier, M.C.2    Shrimpton, P.C.3    Wall, B.F.4
  • 18
    • 0028893476 scopus 로고
    • Computed tomography dose assessment-a practical approach
    • Leitz W, Axelsson B and Szendro G 1995 Computed tomography dose assessment-a practical approach Radiat. Prot. Dosim. 57 377-80
    • (1995) Radiat. Prot. Dosim. , vol.57 , Issue.1-4 , pp. 377-380
    • Leitz, W.1    Axelsson, B.2    Szendro, G.3
  • 19
    • 0036831529 scopus 로고    scopus 로고
    • Radiation dose in CT
    • McNitt-Gray M F 2002 Radiation dose in CT Radiographics 22 1541-53
    • (2002) Radiographics , vol.22 , Issue.6 , pp. 1541-1553
    • McNitt-Gray, M.F.1
  • 21
    • 0037342616 scopus 로고    scopus 로고
    • Influence of phantom diameter, kVp and scan mode upon computed tomography dose index
    • Nickoloff E L, Dutta A K and Lu Z F 2003 Influence of phantom diameter, kVp and scan mode upon computed tomography dose index Med. Phys. 30 395-402
    • (2003) Med. Phys. , vol.30 , Issue.3 , pp. 395-402
    • Nickoloff, E.L.1    Dutta, A.K.2    Lu, Z.F.3
  • 22
    • 0019485556 scopus 로고
    • A method for describing the doses delivered by transmission x-ray computed tomography
    • Shope T B, Gagne R M and Johnson G C 1981 A method for describing the doses delivered by transmission x-ray computed tomography Med. Phys. 8 488-95
    • (1981) Med. Phys. , vol.8 , Issue.4 , pp. 488-495
    • Shope, T.B.1    Gagne, R.M.2    Johnson, G.C.3
  • 23
    • 0033008479 scopus 로고    scopus 로고
    • Radiation effective doses to patients undergoing abdominal CT examinations
    • Ware D E, Huda W, Mergo P J and Litwiller A L 1999 Radiation effective doses to patients undergoing abdominal CT examinations Radiology 210 645-50
    • (1999) Radiology , vol.210 , Issue.3 , pp. 645-650
    • Ware, D.E.1    Huda, W.2    Mergo, P.J.3    Litwiller, A.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.