The operation logic of automatic dose control of fluoroscopy system in conjunction with spectral shaping filters

Author keywords

Automatic dose control; Fluoroscopy; Image receptor; Input exposure; Operation logic; Patient exposure; Spectral shaping filters

Indexed keywords

FLUORESCENT SCREENS;

EID: 34547441020     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2752576     Document Type: Article
Times cited : (46)

References (8)
  • 1
    • 0024413015 scopus 로고
    • Comparison of performance characteristics of conventional and k-edge filters in general diagnostic radiology
    • H. D. Nagel, " Comparison of performance characteristics of conventional and k-edge filters in general diagnostic radiology., " Phys. Med. Biol. 34, 1269-1287 (1989).
    • (1989) Phys. Med. Biol. , vol.34 , pp. 1269-1287
    • Nagel, H.D.1
  • 2
    • 0017876183 scopus 로고
    • Reduction of patient exposures by use of heavy elements as radiation filters in diagnostic radiology
    • J. E. Villagran, B. B. Hobbs, and K. W. Taylor, " Reduction of patient exposures by use of heavy elements as radiation filters in diagnostic radiology., " Radiology 127, 249-254 (1978).
    • (1978) Radiology , vol.127 , pp. 249-254
    • Villagran, J.E.1    Hobbs, B.B.2    Taylor, K.W.3
  • 3
    • 0028285830 scopus 로고
    • Reduction of radiation exposure while maintaining high quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering
    • J. A. den Boer, " Reduction of radiation exposure while maintaining high quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering., " Circulation 89, 2710-2714 (1994).
    • (1994) Circulation , vol.89 , pp. 2710-2714
    • Den Boer, J.A.1
  • 5
  • 6
    • 0028047636 scopus 로고
    • Comparison of beam-hardening and k-edge filters for imaging barium and iodine fluoroscopy
    • R. M. Gagne, P. W. Quinn, and R. J. Jennings, " Comparison of beam-hardening and k-edge filters for imaging barium and iodine fluoroscopy., " Med. Phys. 21, 107-121 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 107-121
    • Gagne, R.M.1    Quinn, P.W.2    Jennings, R.J.3
  • 7
    • 85027221433 scopus 로고    scopus 로고
    • IQAP (Image Quality Acceptance Procedure) under "Service Mode" of Axiom Artis VB 22K System Software. Siemens Axiom Artis dBA Angiography System, Siemens AG, Medical Solutions Angiography, Fluoroscopy and Radiographic Systems, Forchheim, Germany.
    • IQAP (Image Quality Acceptance Procedure) under "Service Mode" of Axiom Artis VB 22K System Software. Siemens Axiom Artis dBA Angiography System, Siemens AG, Medical Solutions Angiography, Fluoroscopy and Radiographic Systems, Forchheim, Germany.
  • 8
    • 85027234220 scopus 로고    scopus 로고
    • 21CFR1020.32, Code of Federal Regulations, Title 21, Volume 8. Revised as of April 2006, DHHS, FDA.
    • 21CFR1020.32, Code of Federal Regulations, Title 21, Volume 8. Revised as of April 2006, DHHS, FDA.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.