Volumn 2, Issue 2, 2008, Pages 114-121

BioMEMS in diagnostics: A review and recent developments

Author keywords

Biochip; BioMEMS; Biosensors; Diagnostics; Microsystems technology

Indexed keywords

BIOASSAY; BIOCHEMISTRY; BIOCHIPS; BIOLOGICAL MATERIALS; COMPOSITE MICROMECHANICS; DRUG DELIVERY; ENGINEERING RESEARCH; MEDICAL APPLICATIONS; MICROARRAYS; MICROELECTROMECHANICAL DEVICES; MICROSYSTEMS; MOLECULAR BIOLOGY; NUCLEIC ACIDS; ORGANIC ACIDS; TISSUE ENGINEERING;

EID: 55949113913     PISSN: 18722121     EISSN: None     Source Type: Journal    
DOI: 10.2174/187221208784705297     Document Type: Review
Times cited : (12)

References (52)
  • 1
    • 11144236389 scopus 로고    scopus 로고
    • A BioMEMS review: MEMS technology for physiologically integrated devices
    • Richards GAC, Shawgo RS, Johnson AM, et al. A BioMEMS review: MEMS technology for physiologically integrated devices, Proc. IEEE 2004; 92: 1.
    • (2004) Proc. IEEE , vol.92 , pp. 1
    • Richards, G.A.C.1    Shawgo, R.S.2    Johnson, A.M.3
  • 2
    • 0020127035 scopus 로고
    • Silicon as a mechanical material
    • Petersen KE, Silicon as a mechanical material. Proc IEEE 1982; 70: 5.
    • (1982) Proc IEEE , vol.70 , pp. 5
    • Petersen, K.E.1
  • 3
    • 0026433724 scopus 로고
    • Microfabrication techniques for integrated sensors and Microsystems
    • Wise KD, Najafi K. Microfabrication techniques for integrated sensors and Microsystems. Science 1991; 254: 1335-1342.
    • (1991) Science , vol.254 , pp. 1335-1342
    • Wise, K.D.1    Najafi, K.2
  • 4
    • 4444248404 scopus 로고    scopus 로고
    • state-of-the-art in detection, opportunities and prospects
    • BioMEMS
    • Bashir R, BioMEMS: state-of-the-art in detection, opportunities and prospects. Adv Drug Deliv Rev 2004; 56: 1565-1586.
    • (2004) Adv Drug Deliv Rev , vol.56 , pp. 1565-1586
    • Bashir, R.1
  • 5
    • 33751410563 scopus 로고    scopus 로고
    • BioMEMS in medicine: Diagnostic and therapeutic systems
    • Grenoble, France
    • Cheung KC, Renaud P. BioMEMS in medicine: Diagnostic and therapeutic systems. Proc ESSDERC 2005: Grenoble, France.
    • (2005) Proc ESSDERC
    • Cheung, K.C.1    Renaud, P.2
  • 8
    • 0034570965 scopus 로고    scopus 로고
    • Microdevices in medicine: Annual review of biomedical engineering
    • Polla DL, Erdman AG, Robbins WP, et al., Microdevices in medicine: Annual review of biomedical engineering. Ann Rev 2000; 2: 551-576.
    • (2000) Ann Rev , vol.2 , pp. 551-576
    • Polla, D.L.1    Erdman, A.G.2    Robbins, W.P.3
  • 10
    • 0034158429 scopus 로고    scopus 로고
    • Biosensors and biochips: Advances in biological and medical diagnostics, Review
    • Vo-Dinh T, Cullum B. Biosensors and biochips: advances in biological and medical diagnostics, Review Fresenius'. J Anal Chem 2000; 366: 540-551.
    • (2000) Fresenius'. J Anal Chem , vol.366 , pp. 540-551
    • Vo-Dinh, T.1    Cullum, B.2
  • 11
    • 33845907391 scopus 로고    scopus 로고
    • Rasmussen CD, Andersen JET, Zachau-Christiansen B, Improved performance of the potentiometric biosensor for the determination of creatinine, analytical letters 2007; 40: 1: 39-52.
    • Rasmussen CD, Andersen JET, Zachau-Christiansen B, Improved performance of the potentiometric biosensor for the determination of creatinine, analytical letters 2007; 40: 1: 39-52.
  • 12
    • 41549106353 scopus 로고    scopus 로고
    • Assembling amperometric biosensors for clinical diagnostics review
    • Belluzo MS, Ribone MÉ, Marina CL, Assembling amperometric biosensors for clinical diagnostics review. Sensors 2008; 8: 1366-1399.
    • (2008) Sensors , vol.8 , pp. 1366-1399
    • Belluzo, M.S.1    Ribone, M.É.2    Marina, C.L.3
  • 13
    • 0032565709 scopus 로고    scopus 로고
    • Optimization of an inorganic/bio-organic matrix for the development of new glucose biosensor membranes
    • Poyard S, Jaffrezic-Renault N, Martelet C, Cosnier S, Labbe P. Optimization of an inorganic/bio-organic matrix for the development of new glucose biosensor membranes. Anal Chim Acta 1998; 364: 165-172.
    • (1998) Anal Chim Acta , vol.364 , pp. 165-172
    • Poyard, S.1    Jaffrezic-Renault, N.2    Martelet, C.3    Cosnier, S.4    Labbe, P.5
  • 14
    • 0033990901 scopus 로고    scopus 로고
    • Improvement of urease based biosensor characteristics using additional layers of charged polymers
    • Soldatkin AP, et al., Improvement of urease based biosensor characteristics using additional layers of charged polymers. Anal Chim Acta 2000; 401.
    • (2000) Anal Chim Acta , pp. 401
    • Soldatkin, A.P.1
  • 16
    • 0037307131 scopus 로고    scopus 로고
    • Protein chip technology
    • Zhu H, et al., Protein chip technology. Curr Opin Chem Biol 2003; 7: 40-45.
    • (2003) Curr Opin Chem Biol , vol.7 , pp. 40-45
    • Zhu, H.1
  • 18
    • 0037084073 scopus 로고    scopus 로고
    • Ultra-low volume, real-time measurments of lactate from the single heart cell using Microsystems technology
    • Cia X, Klauke N, Glidle A, Cobbold P, Smith GL, Cooper JM. Ultra-low volume, real-time measurments of lactate from the single heart cell using Microsystems technology. Anal Chem 2002; 74: 908-914.
    • (2002) Anal Chem , vol.74 , pp. 908-914
    • Cia, X.1    Klauke, N.2    Glidle, A.3    Cobbold, P.4    Smith, G.L.5    Cooper, J.M.6
  • 19
    • 0035014156 scopus 로고    scopus 로고
    • Electronic detection of nucleic acids: A versatile platform for molecular diagnostics
    • Umek R, Lin M, Vielmetter SW, et al. Electronic detection of nucleic acids: a versatile platform for molecular diagnostics. J Mol Diag 2001; 3: 74-84.
    • (2001) J Mol Diag , vol.3 , pp. 74-84
    • Umek, R.1    Lin, M.2    Vielmetter, S.W.3
  • 20
    • 34548809222 scopus 로고    scopus 로고
    • An electrochemical approach for the detection of HIV-1 protease
    • Kerman K, Mahmoud KA, Kraatz HB. An electrochemical approach for the detection of HIV-1 protease. Chem Commun 2007.
    • (2007) Chem Commun
    • Kerman, K.1    Mahmoud, K.A.2    Kraatz, H.B.3
  • 22
    • 0037144244 scopus 로고    scopus 로고
    • Microscale electronic detection of backterial metabolism
    • Gomez R, Bashir R, Bhunia AK. Microscale electronic detection of backterial metabolism. Sens Actuators B Chem 2002; 86: 198-208.
    • (2002) Sens Actuators B Chem , vol.86 , pp. 198-208
    • Gomez, R.1    Bashir, R.2    Bhunia, A.K.3
  • 23
    • 34547578768 scopus 로고    scopus 로고
    • Label-free impedance biosensors: Opportunities and challenges
    • Daniels JS, Pourmand N. Label-free impedance biosensors: opportunities and challenges. Electroanalysis 2007; 19: 12.
    • (2007) Electroanalysis , vol.19 , pp. 12
    • Daniels, J.S.1    Pourmand, N.2
  • 24
    • 0037154825 scopus 로고    scopus 로고
    • Array-based electrical detection of DNA with nanoparticle probes
    • Park S-J, Taton TA, Mirkin CA. Array-based electrical detection of DNA with nanoparticle probes. Science 2002; 295: 1503-1506.
    • (2002) Science , vol.295 , pp. 1503-1506
    • Park, S.-J.1    Taton, T.A.2    Mirkin, C.A.3
  • 25
    • 55949087299 scopus 로고    scopus 로고
    • Patno, T., Khoury, C.: WO04042070 (2004).
    • Patno, T., Khoury, C.: WO04042070 (2004).
  • 26
    • 3142517781 scopus 로고    scopus 로고
    • Resistivity probing of multilayered tissue phantoms using microelectrodes
    • Linderholm P, Bertsch A, Renaud P. Resistivity probing of multilayered tissue phantoms using microelectrodes. Physiol Measurem 2004; 645-658.
    • (2004) Physiol Measurem , pp. 645-658
    • Linderholm, P.1    Bertsch, A.2    Renaud, P.3
  • 28
    • 44949196148 scopus 로고    scopus 로고
    • A review of microcantilevers for sensing applications
    • June
    • Vashist SK. A review of microcantilevers for sensing applications. AZojono J Nanotechnol Online, June 2007.
    • (2007) AZojono J Nanotechnol Online
    • Vashist, S.K.1
  • 29
    • 33745633628 scopus 로고    scopus 로고
    • Cantilever based mass sensor with hard contact readout
    • Dohn S, Hansen O, Boisen A. Cantilever based mass sensor with hard contact readout. Appl Phys Lett 2006; 88: 264104-264107.
    • (2006) Appl Phys Lett , vol.88 , pp. 264104-264107
    • Dohn, S.1    Hansen, O.2    Boisen, A.3
  • 30
    • 33744492070 scopus 로고    scopus 로고
    • High-mode resonant piezoresistive cantilever sensors for tensfemtogram resoluble mass sensing in air
    • Jin D, Li X, Liu J, Zuo G, Wang Y, Liu M, et al. High-mode resonant piezoresistive cantilever sensors for tensfemtogram resoluble mass sensing in air, J Micromech Microeng 2006; 16.
    • (2006) J Micromech Microeng , pp. 16
    • Jin, D.1    Li, X.2    Liu, J.3    Zuo, G.4    Wang, Y.5    Liu, M.6
  • 31
    • 14644415474 scopus 로고    scopus 로고
    • Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers
    • Wee KW, Kang GY, Park J, Kang JY, Yoon DS, Park JH, et al. Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantilevers. Biosens Bioelectr 2005; 20: 1932-1938.
    • (2005) Biosens Bioelectr , vol.20 , pp. 1932-1938
    • Wee, K.W.1    Kang, G.Y.2    Park, J.3    Kang, J.Y.4    Yoon, D.S.5    Park, J.H.6
  • 32
    • 33744749849 scopus 로고    scopus 로고
    • High sensitivity piezoresistive cantilever sensor for biomolecular detection
    • He JH, Li YF. High sensitivity piezoresistive cantilever sensor for biomolecular detection. J Phys Conf Series 2006; 34: 429-435.
    • (2006) J Phys Conf Series , vol.34 , pp. 429-435
    • He, J.H.1    Li, Y.F.2
  • 35
    • 0001453196 scopus 로고    scopus 로고
    • Scanning force microscopy in the dynamic mode using microfabricated capacitive sensors
    • Blanc N, Brugger J, Rooij NFD, Durig U. Scanning force microscopy in the dynamic mode using microfabricated capacitive sensors. J Vac Sci Technol B 1996; 14: 901-905.
    • (1996) J Vac Sci Technol B , vol.14 , pp. 901-905
    • Blanc, N.1    Brugger, J.2    Rooij, N.F.D.3    Durig, U.4
  • 36
    • 33847741118 scopus 로고    scopus 로고
    • Fast, ultrasensitive virus detection using a young interferometer sensor
    • Ymeti A, Greve J, Lambeck PV. Fast, ultrasensitive virus detection using a young interferometer sensor. Nanoletters 2007; 7: 394 -397.
    • (2007) Nanoletters , vol.7 , pp. 394-397
    • Ymeti, A.1    Greve, J.2    Lambeck, P.V.3
  • 37
    • 1842788500 scopus 로고    scopus 로고
    • Single virus particle mass detection using microresonators with nanoscale thickness
    • Gupta A, Akin D, Bashir R. Single virus particle mass detection using microresonators with nanoscale thickness. Appl Phys Lett 2004; 84: 1976-1978.
    • (2004) Appl Phys Lett , vol.84 , pp. 1976-1978
    • Gupta, A.1    Akin, D.2    Bashir, R.3
  • 38
    • 7544230375 scopus 로고    scopus 로고
    • Virus detection using nanoelectromechanical devices
    • Ilic B, Yang Y, Craighead HG. Virus detection using nanoelectromechanical devices. Appl Phys Lett 2004; 85: 2604-2606.
    • (2004) Appl Phys Lett , vol.85 , pp. 2604-2606
    • Ilic, B.1    Yang, Y.2    Craighead, H.G.3
  • 39
    • 55949102575 scopus 로고    scopus 로고
    • Bloechl, P., Rossel, C. P., Willemin, M.: WO01020616 (2001).
    • Bloechl, P., Rossel, C. P., Willemin, M.: WO01020616 (2001).
  • 40
    • 34548444233 scopus 로고    scopus 로고
    • Piezoelectric sensor for determination of genetically modified Soybean Roundup Ready® in samples not amplified by PCR
    • Stobiecka M, Cie..la JM, Janowska B, Tudek B, Radecka H. Piezoelectric sensor for determination of genetically modified Soybean Roundup Ready® in samples not amplified by PCR. Sensors 2007; 7: 1462-1479.
    • (2007) Sensors , vol.7 , pp. 1462-1479
    • Stobiecka, M.1    Cie2    la, J.M.3    Janowska, B.4    Tudek, B.5    Radecka, H.6
  • 41
    • 33747373852 scopus 로고    scopus 로고
    • Integration of a surface acoustic wave biosensor in a microfluidic polymer chip
    • Länge K, Blaess G, Voigt A, Goetzen R, Rapp M. Integration of a surface acoustic wave biosensor in a microfluidic polymer chip. Biosens Bioelectr 2006; 22: 227-23.
    • (2006) Biosens Bioelectr , vol.22 , pp. 227-323
    • Länge, K.1    Blaess, G.2    Voigt, A.3    Goetzen, R.4    Rapp, M.5
  • 43
    • 0034941615 scopus 로고    scopus 로고
    • Detection of E. coli using a microfluidics-based antibody biochip detection system
    • Stokes G, Griffin GD, Vo-Dinh F. Detection of E. coli using a microfluidics-based antibody biochip detection system. J Anal Chem 2001; 369: 295-301.
    • (2001) J Anal Chem , vol.369 , pp. 295-301
    • Stokes, G.1    Griffin, G.D.2    Vo-Dinh, F.3
  • 45
    • 55949103717 scopus 로고    scopus 로고
    • US20077267948
    • Vo-Dinh, T.: US20077267948 (2007).
    • (2007)
    • Vo-Dinh, T.1
  • 47
    • 55949095797 scopus 로고    scopus 로고
    • Neuzil, P., Pipper, J., Novak, L.: WO08024080 (2008).
    • Neuzil, P., Pipper, J., Novak, L.: WO08024080 (2008).
  • 49
    • 55949098634 scopus 로고    scopus 로고
    • Morisette, T.D., Lee, K.F., Selim, H., Erimli, B., Razouk, L., Bashir, R.: WO07044088 (2007).
    • Morisette, T.D., Lee, K.F., Selim, H., Erimli, B., Razouk, L., Bashir, R.: WO07044088 (2007).
  • 51
    • 55949124143 scopus 로고    scopus 로고
    • Throndset, W., Nassef, H.R., Manger, I.D., Liau, B.Y.-H., Fowler, K., Farell, Daridon, A., Chou, H.-P.: US20077312085 (2007).
    • Throndset, W., Nassef, H.R., Manger, I.D., Liau, B.Y.-H., Fowler, K., Farell, Daridon, A., Chou, H.-P.: US20077312085 (2007).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.