메뉴 건너뛰기




Volumn 2005, Issue , 2005, Pages 345-350

BioMEMS in medicine: Diagnostic and therapeutic systems

Author keywords

[No Author keywords available]

Indexed keywords

CELLS; MEDICINE; MICROELECTRODES; NEUROLOGY; PATIENT TREATMENT; PHYSICAL THERAPY;

EID: 33751410563     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ESSDER.2005.1546656     Document Type: Conference Paper
Times cited : (5)

References (33)
  • 1
    • 0036405278 scopus 로고    scopus 로고
    • DNA microarray technology: Devices, systems, and applications
    • M. J. Heller, "DNA MICROARRAY TECHNOLOGY: Devices, Systems, and Applications," Annual Review of Biomedical Engineering, vol. 4, pp. 129-153, 2002.
    • (2002) Annual Review of Biomedical Engineering , vol.4 , pp. 129-153
    • Heller, M.J.1
  • 2
    • 1442298511 scopus 로고    scopus 로고
    • Neuroelectronic interfacing: Semiconductor chips with ion channels, nerve cells, and brain
    • R. Waser, Ed. Berlin: Wiley-VCH Verlag
    • P. Fromherz, "Neuroelectronic Interfacing: Semiconductor Chips with Ion Channels, Nerve Cells, and Brain," in Nanoelectronics and Information Technology, R. Waser, Ed. Berlin: Wiley-VCH Verlag, 2003, pp. 781-810.
    • (2003) Nanoelectronics and Information Technology , pp. 781-810
    • Fromherz, P.1
  • 3
    • 0031957671 scopus 로고    scopus 로고
    • Separation of polystyrene microbeads using dielectrophoretic/ gravitational field-FlowFractionation
    • X. B. Wang, J. Vykoukal, F. F. Becker, and P. R. C. Gascoyne, "Separation of Polystyrene Microbeads Using Dielectrophoretic/Gravitational Field-FlowFractionation," Biophysical Journal, vol. 74, pp. 2687-2701, 1998.
    • (1998) Biophysical Journal , vol.74 , pp. 2687-2701
    • Wang, X.B.1    Vykoukal, J.2    Becker, F.F.3    Gascoyne, P.R.C.4
  • 4
    • 0036107267 scopus 로고    scopus 로고
    • Patch clamp on a chip
    • F. J. Sigworth and K. G. Klemic, "Patch Clamp on a Chip," Biophys. J., vol. 82, pp. 2831-2832, 2002.
    • (2002) Biophys. J. , vol.82 , pp. 2831-2832
    • Sigworth, F.J.1    Klemic, K.G.2
  • 5
    • 0141995822 scopus 로고    scopus 로고
    • Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis
    • E. T. Lagally, C. A. Emrich, and R. A. Mathies, "Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis," Lab on a Chip, vol. l, pp. 102-107, 2001.
    • (2001) Lab on a Chip , vol.50 , pp. 102-107
    • Lagally, E.T.1    Emrich, C.A.2    Mathies, R.A.3
  • 7
    • 0023874075 scopus 로고
    • Multisite hippocampal slice recording and stimulation using a 32 element microelectrode array
    • J. L. Novak and B. C. Wheeler, "Multisite hippocampal slice recording and stimulation using a 32 element microelectrode array," Journal of Neuroscience Methods, vol. 23, pp. 149-159, 1988.
    • (1988) Journal of Neuroscience Methods , vol.23 , pp. 149-159
    • Novak, J.L.1    Wheeler, B.C.2
  • 8
    • 0037086859 scopus 로고    scopus 로고
    • A three-dimensional multi-electrode array for multi-site stimulation and recording in acute brain slices
    • M. O. Heuschkel, M. Fejtl, M. Raggenbass, D. Bertrand, and P. Renaud, "A three-dimensional multi-electrode array for multi-site stimulation and recording in acute brain slices," Journal of Neuroscience Methods, vol. 114, pp. 135-148, 2002.
    • (2002) Journal of Neuroscience Methods , vol.114 , pp. 135-148
    • Heuschkel, M.O.1    Fejtl, M.2    Raggenbass, M.3    Bertrand, D.4    Renaud, P.5
  • 9
    • 3142517781 scopus 로고    scopus 로고
    • Resistivity probing of multi-layered tissue phantoms using microelectrodes
    • P. Linderholm, A. Bertsch, and P. Renaud, "Resistivity probing of multi-layered tissue phantoms using microelectrodes," Physiological Measurement, pp. 645-658, 2004.
    • (2004) Physiological Measurement , pp. 645-658
    • Linderholm, P.1    Bertsch, A.2    Renaud, P.3
  • 10
    • 0345493749 scopus 로고    scopus 로고
    • Paired microelectrode system: Dielectrophoretic particle sorting and force calibration
    • T. Schnelle, T. Muller, G. Gradl, S. G. Shirley, and G. Fuhr, "Paired microelectrode system: dielectrophoretic particle sorting and force calibration," Journal of Electrostatics, vol. 47, pp. 121-132, 1999.
    • (1999) Journal of Electrostatics , vol.47 , pp. 121-132
    • Schnelle, T.1    Muller, T.2    Gradl, G.3    Shirley, S.G.4    Fuhr, G.5
  • 11
    • 4344645067 scopus 로고    scopus 로고
    • Dielectrophoresis-based sample handling in general-purpose programmable diagnostic instruments
    • P. R. C. Gascoyne and J. V. Vykoukal, "Dielectrophoresis-based sample handling in general-purpose programmable diagnostic instruments," Proceedings of the IEEE, vol. 92, pp. 22-42,2004.
    • (2004) Proceedings of the IEEE , vol.92 , pp. 22-42
    • Gascoyne, P.R.C.1    Vykoukal, J.V.2
  • 12
    • 2942667055 scopus 로고    scopus 로고
    • Towards single-cell controlled electroporation in a microfluidic device
    • Nara, Japan
    • U. Seger, S. Gawad, A. Scheer, and P. Renaud, "Towards Single-Cell Controlled Electroporation in a Microfluidic Device," presented at Micro Total Analysis Systems, Nara, Japan, 2002.
    • (2002) Micro Total Analysis Systems
    • Seger, U.1    Gawad, S.2    Scheer, A.3    Renaud, P.4
  • 13
    • 1942437985 scopus 로고    scopus 로고
    • Cell immersion and cell dipping in microfluidic devices
    • U. Seger, S. Gawad, R. Johann, A. Bertsch, and P. Renaud, "Cell immersion and cell dipping in microfluidic devices," Lab on a Chip, vol. 4, pp. 148-151, 2004.
    • (2004) Lab on a Chip , vol.4 , pp. 148-151
    • Seger, U.1    Gawad, S.2    Johann, R.3    Bertsch, A.4    Renaud, P.5
  • 14
    • 0141989814 scopus 로고    scopus 로고
    • Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing
    • S. Gawad, L. Schild, and P. Renaud, "Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing," Lab on a Chip, vol. 1, pp. 76-82, 2001.
    • (2001) Lab on a Chip , vol.1 , pp. 76-82
    • Gawad, S.1    Schild, L.2    Renaud, P.3
  • 16
    • 3142726971 scopus 로고    scopus 로고
    • Dielectric spectroscopy in a micromachined flow cytometer: Theoretical and practical considerations
    • S. Gawad, K. Cheung, U. Seger, A. Bertsch, and P. Renaud, "Dielectric spectroscopy in a micromachined flow cytometer: theoretical and practical considerations," Lab on a Chip, vol. 4, pp. 241-251,2004.
    • (2004) Lab on a Chip , vol.4 , pp. 241-251
    • Gawad, S.1    Cheung, K.2    Seger, U.3    Bertsch, A.4    Renaud, P.5
  • 17
    • 0036778803 scopus 로고    scopus 로고
    • Characterization of heterogeneous systems by dielectric spectroscopy
    • K. Asami, "Characterization of heterogeneous systems by dielectric spectroscopy," Progess in Polymer Science, vol. 27, pp. 1617-1659, 2002.
    • (2002) Progess in Polymer Science , vol.27 , pp. 1617-1659
    • Asami, K.1
  • 19
    • 19444377196 scopus 로고    scopus 로고
    • Impedance spectroscopy fLow cytometry: On-chip label-free cell differentiation
    • vol. in press
    • K. Cheung, S. Gawad, and P. Renaud, "Impedance Spectroscopy FLow Cytometry: On-Chip Label-Free Cell Differentiation," Cytometry A, vol. in press, 2005.
    • (2005) Cytometry A
    • Cheung, K.1    Gawad, S.2    Renaud, P.3
  • 24
    • 0036015967 scopus 로고    scopus 로고
    • A biohybrid system to interface peripheral nerves after traumatic lesions: Design of a high channel sieve electrode
    • T. Stieglitz, H. H. Ruf, M. Gross, M. Schuettler, and J.-U. Meyer, "A biohybrid system to interface peripheral nerves after traumatic lesions: design of a high channel sieve electrode," Biosensors and Bioelectronics, vol. 17, pp. 685-696, 2002.
    • (2002) Biosensors and Bioelectronics , vol.17 , pp. 685-696
    • Stieglitz, T.1    Ruf, H.H.2    Gross, M.3    Schuettler, M.4    Meyer, J.-U.5
  • 26
    • 0036403701 scopus 로고    scopus 로고
    • Selective electrical interfaces with the nervous system
    • W. L. C. Rutten, "Selective Electrical Interfaces with the Nervous System," Annual Review of Biomedical Engineering, vol. 4, pp. 407-452, 2002.
    • (2002) Annual Review of Biomedical Engineering , vol.4 , pp. 407-452
    • Rutten, W.L.C.1
  • 27
    • 2442708539 scopus 로고    scopus 로고
    • Wireless implantable microsystems: High-density electronic interfaces to the nervous system
    • K. D. Wise, D. J. Anderson, J. F. Hetke, D. R. Kipke, and K. Najafi, "Wireless implantable microsystems: high-density electronic interfaces to the nervous system," Proceedings of the IEEE, vol. 92, pp. 76-97, 2004.
    • (2004) Proceedings of the IEEE , vol.92 , pp. 76-97
    • Wise, K.D.1    Anderson, D.J.2    Hetke, J.F.3    Kipke, D.R.4    Najafi, K.5
  • 28
    • 0026205082 scopus 로고
    • A silicon-based, three-dimensional neural interface: Manufacturing processes for an intracortical electrode array
    • P. K. Campbell, K. E. Jones, R. J. Huber, K. W. Horch, and R. A. Normann, "A Silicon-Based, Three-Dimensional Neural Interface: Manufacturing Processes for an Intracortical Electrode Array," IEEE Transactions on Biomedical Engineering, vol. 38, pp. 758-768, 1991.
    • (1991) IEEE Transactions on Biomedical Engineering , vol.38 , pp. 758-768
    • Campbell, P.K.1    Jones, K.E.2    Huber, R.J.3    Horch, K.W.4    Normann, R.A.5
  • 29
    • 0002429667 scopus 로고    scopus 로고
    • Polyimidebased microfluidic devices
    • S. Metz, R. Holzer, and P. Renaud, "Polyimidebased microfluidic devices," Lab on a Chip, vol. 1, pp. 29-34, 2001.
    • (2001) Lab on a Chip , vol.1 , pp. 29-34
    • Metz, S.1    Holzer, R.2    Renaud, P.3
  • 30
    • 1642349268 scopus 로고    scopus 로고
    • Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity
    • S. Metz, A. Bertsch, D. Bertrand, and P. Renaud, "Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity," Biosensors and Bioelectronics,vol. 19, pp. 1309-1318, 2004.
    • (2004) Biosensors and Bioelectronics , vol.19 , pp. 1309-1318
    • Metz, S.1    Bertsch, A.2    Bertrand, D.3    Renaud, P.4
  • 31
    • 1642587807 scopus 로고    scopus 로고
    • Polyimide microfluidic devices with integrated nanoporous filtration areas manufactured by micromachining and ion track technology
    • S. Metz, C. Trautmann, A. Bertsch, and P. Renaud, "Polyimide microfluidic devices with integrated nanoporous filtration areas manufactured by micromachining and ion track technology," Journal of Micromechanics and Microengineering, vol. 14, pp. 324-331, 2004.
    • (2004) Journal of Micromechanics and Microengineering , vol.14 , pp. 324-331
    • Metz, S.1    Trautmann, C.2    Bertsch, A.3    Renaud, P.4
  • 32
    • 1942437994 scopus 로고    scopus 로고
    • Polyimide and SU-8 microfluidic devices manufactured by heat-depolymerizable sacrificial material technique
    • S. Metz, S. Jiguet, A. Bertsch, and P. Renaud, "Polyimide and SU-8 microfluidic devices manufactured by heat-depolymerizable sacrificial material technique," Lab on a Chip, vol. 4, pp. 114-120, 2004.
    • (2004) Lab on a Chip , vol.4 , pp. 114-120
    • Metz, S.1    Jiguet, S.2    Bertsch, A.3    Renaud, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.