메뉴 건너뛰기




Volumn 115, Issue 2, 2007, Pages 161-166

Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks

Author keywords

All ceramic; FPD; Load bearing capacity; Preliminary damage; Zirconia

Indexed keywords

ZIRCONIUM; ZIRCONIUM OXIDE;

EID: 34247491685     PISSN: 09098836     EISSN: 16000722     Source Type: Journal    
DOI: 10.1111/j.1600-0722.2007.00429.x     Document Type: Article
Times cited : (75)

References (33)
  • 1
    • 0028390711 scopus 로고
    • Ceramic vs. porcelain-fused-to-metal crowns: Give your patients a choice
    • CHRISTENSEN GJ. Ceramic vs. porcelain-fused-to-metal crowns: give your patients a choice. J Am Dent Assoc 1994; 125: 314.
    • (1994) J Am Dent Assoc , vol.125 , pp. 314
    • CHRISTENSEN, G.J.1
  • 2
    • 0031151737 scopus 로고    scopus 로고
    • Allergic reaction following insertion of a Pd-Cu-Au fixed partial denture: A clinical report
    • HANSEN PA, WEST LA. Allergic reaction following insertion of a Pd-Cu-Au fixed partial denture: a clinical report. J Prosthodont 1997; 6: 144-148.
    • (1997) J Prosthodont , vol.6 , pp. 144-148
    • HANSEN, P.A.1    WEST, L.A.2
  • 3
    • 14844364021 scopus 로고    scopus 로고
    • P, CARLSON P, NILNER K. All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study
    • VULT VON STEYERN P, CARLSON P, NILNER K. All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil 2005; 32: 180-187.
    • (2005) J Oral Rehabil , vol.32 , pp. 180-187
    • VON STEYERN, V.1
  • 4
    • 21244506130 scopus 로고    scopus 로고
    • A clinical report and overview of scientific studies and clinical procedures conducted on the 3M ESPE Lava All-Ceramic System
    • PIWOWARCZYK A, OTTL P, LAUER HC, KURETZKY T. A clinical report and overview of scientific studies and clinical procedures conducted on the 3M ESPE Lava All-Ceramic System. J Prosthodont 2005; 14: 39-45.
    • (2005) J Prosthodont , vol.14 , pp. 39-45
    • PIWOWARCZYK, A.1    OTTL, P.2    LAUER, H.C.3    KURETZKY, T.4
  • 5
    • 0035319974 scopus 로고    scopus 로고
    • Reliability and strength of all-ceramic dental restorations fabricated by direct ceramic machining (DCM)
    • FILSER F, KOCHER P, WEIBEL F, LÜTHY H, SCHÄRER P, GAUCKLER LJ. Reliability and strength of all-ceramic dental restorations fabricated by direct ceramic machining (DCM). Int J Comput Dent 2001; 4: 89-106.
    • (2001) Int J Comput Dent , vol.4 , pp. 89-106
    • FILSER, F.1    KOCHER, P.2    WEIBEL, F.3    LÜTHY, H.4    SCHÄRER, P.5    GAUCKLER, L.J.6
  • 6
    • 0033873591 scopus 로고    scopus 로고
    • Transformation toughening in zirconia-containing ceramics
    • HANNINK RHJ, KELLY PM, MUDDLE BC. Transformation toughening in zirconia-containing ceramics. J Am Ceram Soc 2000; 83: 461-487.
    • (2000) J Am Ceram Soc , vol.83 , pp. 461-487
    • HANNINK, R.H.J.1    KELLY, P.M.2    MUDDLE, B.C.3
  • 7
    • 0033301391 scopus 로고    scopus 로고
    • Zirconia-TZP and alumina - advanced technologies for the manufacturing of single crowns
    • LUTHARDT RG, SANDKUHL O, REITZ B. Zirconia-TZP and alumina - advanced technologies for the manufacturing of single crowns. Eur J Prosthodont Restor Dent 1999; 7: 113-119.
    • (1999) Eur J Prosthodont Restor Dent , vol.7 , pp. 113-119
    • LUTHARDT, R.G.1    SANDKUHL, O.2    REITZ, B.3
  • 9
    • 0035495965 scopus 로고    scopus 로고
    • Computer-assisted generation of all-ceramic crowns and fixed partial dentures
    • BESIMO CE, SPIELMANN HP, ROHNER HP. Computer-assisted generation of all-ceramic crowns and fixed partial dentures. Int J Comput Dent 2001; 4: 243-262.
    • (2001) Int J Comput Dent , vol.4 , pp. 243-262
    • BESIMO, C.E.1    SPIELMANN, H.P.2    ROHNER, H.P.3
  • 10
    • 0025418986 scopus 로고
    • Analysis of hot isostatic pressing of presintered zirconia
    • KIM J-Y, UCHIDA N, SAITO K, UEMATSU K. Analysis of hot isostatic pressing of presintered zirconia. J Am Ceram Soc 1990; 73: 1069-1073.
    • (1990) J Am Ceram Soc , vol.73 , pp. 1069-1073
    • KIM, J.-Y.1    UCHIDA, N.2    SAITO, K.3    UEMATSU, K.4
  • 13
    • 2442530603 scopus 로고    scopus 로고
    • Long-term strength of ceramics for biomedical applications
    • ZHANO Y, LAWN B. Long-term strength of ceramics for biomedical applications. J Biomed Mater Res 2004; 69B: 166-172.
    • (2004) J Biomed Mater Res , vol.69 B , pp. 166-172
    • ZHANO, Y.1    LAWN, B.2
  • 14
  • 15
    • 0036716828 scopus 로고    scopus 로고
    • Influence of connector design on fracture probability of ceramic fixed-partial dentures
    • OH W, GOTZEN N, ANUSAVICE KJ. Influence of connector design on fracture probability of ceramic fixed-partial dentures. J Dent Res 2002; 81: 623-627.
    • (2002) J Dent Res , vol.81 , pp. 623-627
    • OH, W.1    GOTZEN, N.2    ANUSAVICE, K.J.3
  • 16
    • 0028455065 scopus 로고
    • Tensile properties of mineralized and demineralized human and bovine dentin
    • SANO H, CIUCCHI B, MATTHEWS WG, PASHLEY DH. Tensile properties of mineralized and demineralized human and bovine dentin. J Dent Res 1994; 73: 1205-1211.
    • (1994) J Dent Res , vol.73 , pp. 1205-1211
    • SANO, H.1    CIUCCHI, B.2    MATTHEWS, W.G.3    PASHLEY, D.H.4
  • 17
    • 0027693217 scopus 로고
    • Numeric approach to the biomcchanical analysis of thermal effects in coated implants
    • MOROI HH, OKIMOTO K, MOROI R, TERADA Y. Numeric approach to the biomcchanical analysis of thermal effects in coated implants. Int J Prosthodont 1993; 6: 564-572.
    • (1993) Int J Prosthodont , vol.6 , pp. 564-572
    • MOROI, H.H.1    OKIMOTO, K.2    MOROI, R.3    TERADA, Y.4
  • 18
    • 0027585968 scopus 로고
    • Fracture strength of all-porcelain, resin-bonded bridges after testing in an artificial oral environment
    • KERN M, DOUGLAS WH, FECHTIG T, STRUB JR, DELONG R. Fracture strength of all-porcelain, resin-bonded bridges after testing in an artificial oral environment. J Dent 1993; 21: 117-121.
    • (1993) J Dent , vol.21 , pp. 117-121
    • KERN, M.1    DOUGLAS, W.H.2    FECHTIG, T.3    STRUB, J.R.4    DELONG, R.5
  • 19
    • 33644849619 scopus 로고    scopus 로고
    • In vitro fracture resistance of four-unit fiber-reinforced composite fixed partial dentures
    • STIESCH-SCHOLZ M, SCHULZ K, BORCHERS L. In vitro fracture resistance of four-unit fiber-reinforced composite fixed partial dentures. Dent Mater 2006; 22: 374-381.
    • (2006) Dent Mater , vol.22 , pp. 374-381
    • STIESCH-SCHOLZ, M.1    SCHULZ, K.2    BORCHERS, L.3
  • 20
    • 0001572676 scopus 로고
    • Moisture assisted crack growth in ceramics
    • WIEDERHORN SM. Moisture assisted crack growth in ceramics. Int J Fracture Mech 1968; 4: 171-177.
    • (1968) Int J Fracture Mech , vol.4 , pp. 171-177
    • WIEDERHORN, S.M.1
  • 22
    • 0021510085 scopus 로고
    • Biocompatibility of magnesia-partially stabilized zirconia (Mg-PSZ)
    • GARVIE RC, URBANI C, KENNEDY DR, MCNEUER JC. Biocompatibility of magnesia-partially stabilized zirconia (Mg-PSZ). J Mater Sci 1984; 19: 3224-3228.
    • (1984) J Mater Sci , vol.19 , pp. 3224-3228
    • GARVIE, R.C.1    URBANI, C.2    KENNEDY, D.R.3    MCNEUER, J.C.4
  • 23
    • 0025124253 scopus 로고
    • Mechanical behaviour of zirconia and zirconia-toughened alumina in a simulated body environment
    • THOMPSON I, RAWLINGS RD. Mechanical behaviour of zirconia and zirconia-toughened alumina in a simulated body environment. Biomaterials 1990; 11: 505-508.
    • (1990) Biomaterials , vol.11 , pp. 505-508
    • THOMPSON, I.1    RAWLINGS, R.D.2
  • 24
    • 0024641459 scopus 로고
    • In vitro aging of yttria stabilized zirconia
    • DRUMMOND JL. In vitro aging of yttria stabilized zirconia. J Am Ceram Soc 1989; 72: 675-676.
    • (1989) J Am Ceram Soc , vol.72 , pp. 675-676
    • DRUMMOND, J.L.1
  • 25
    • 0026824361 scopus 로고
    • Temperature extremes produced orally by hot and cold liquids
    • PALMER DS, BARCO MT, BILLY EJ. Temperature extremes produced orally by hot and cold liquids. J Prosthet Dent 1992; 67: 325-327.
    • (1992) J Prosthet Dent , vol.67 , pp. 325-327
    • PALMER, D.S.1    BARCO, M.T.2    BILLY, E.J.3
  • 26
    • 0033071448 scopus 로고    scopus 로고
    • Thermal cycling procedures for laboratory testing of dental restorations
    • GALE MS, DARVELL BW. Thermal cycling procedures for laboratory testing of dental restorations. J Dent 1999; 27: 89-99.
    • (1999) J Dent , vol.27 , pp. 89-99
    • GALE, M.S.1    DARVELL, B.W.2
  • 27
    • 30344459124 scopus 로고    scopus 로고
    • Influence of stress Simulation parameters on the fracture strength of allceramic fixed-partial dentures
    • ROSENTRITT M, BEHR M, GEBHARD R, HANDEL G. Influence of stress Simulation parameters on the fracture strength of allceramic fixed-partial dentures. Dent Mater 2006; 22: 176-182.
    • (2006) Dent Mater , vol.22 , pp. 176-182
    • ROSENTRITT, M.1    BEHR, M.2    GEBHARD, R.3    HANDEL, G.4
  • 28
    • 1842783267 scopus 로고    scopus 로고
    • GUAZZATO M, ALBAKRY M, RINGER SP, SWAIN MV. Strength, fracture toughness and microstructure of a selection of all ceramic materials. Part II. Zirconia-based dental ceramics. Dent Mater 2004; 20: 449-456.
    • GUAZZATO M, ALBAKRY M, RINGER SP, SWAIN MV. Strength, fracture toughness and microstructure of a selection of all ceramic materials. Part II. Zirconia-based dental ceramics. Dent Mater 2004; 20: 449-456.
  • 30
    • 0042778575 scopus 로고    scopus 로고
    • Belastbarkeit vollkeramischer Scitenzahnbrücken aus neuen Hartkernkeramiken [Fracture strength of all-ceramic fixed partial dentures]
    • TINSCHERT J, NATT G, JOREWITZ A, FISCHER H, SPIEKERMANN H, MARX R. Belastbarkeit vollkeramischer Scitenzahnbrücken aus neuen Hartkernkeramiken [Fracture strength of all-ceramic fixed partial dentures]. Dtsch Zahnärztl Z 2000; 55: 610-616.
    • (2000) Dtsch Zahnärztl Z , vol.55 , pp. 610-616
    • TINSCHERT, J.1    NATT, G.2    JOREWITZ, A.3    FISCHER, H.4    SPIEKERMANN, H.5    MARX, R.6
  • 32
    • 0141973963 scopus 로고
    • Maximale Kaukraft als Berechnungsfaktor zahntechnischer Konstruktionen [Maximal biteforce, a factor in designing dental constructions]
    • KÖRBER KH, LUDWIG K. Maximale Kaukraft als Berechnungsfaktor zahntechnischer Konstruktionen [Maximal biteforce, a factor in designing dental constructions]. Dent Lab 1983; 31: 55-60.
    • (1983) Dent Lab , vol.31 , pp. 55-60
    • KÖRBER, K.H.1    LUDWIG, K.2
  • 33
    • 9944256780 scopus 로고    scopus 로고
    • Ceramic behavior under different environmental and loading conditions
    • ELIADES G, ELIADES T, BRANTLEY WA, WATTS DC, eds, Chicago: Quintessence Publications
    • DRUMMOND JL. Ceramic behavior under different environmental and loading conditions. In: ELIADES G, ELIADES T, BRANTLEY WA, WATTS DC, eds. Dental materials in vivo: aging and related phenomena. Chicago: Quintessence Publications, 2003; 35-45.
    • (2003) Dental materials in vivo: Aging and related phenomena , pp. 35-45
    • DRUMMOND, J.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.