1
-
-
0020688695
-
Developement of an artificial oral environment for the testing of dental restoratives: Bi-axial force and movement control
-
R. DeLong, and W.H. Douglas Developement of an artificial oral environment for the testing of dental restoratives: bi-axial force and movement control J Dent Res 62 1982 32 36
-
(1982)
J Dent Res
, vol.62
, pp. 32-36
-
-
Delong, R.1
Douglas, W.H.2
-
2
-
-
0026142466
-
An artificial oral environment for testing dental materials
-
R. DeLong, and W.H. Douglas An artificial oral environment for testing dental materials IEEE Trans Biomater Eng 4 1991 339 345
-
(1991)
IEEE Trans Biomater Eng
, vol.4
, pp. 339-345
-
-
Delong, R.1
Douglas, W.H.2
-
4
-
-
5244299716
-
Verschleiss von Schmelz, Amalgam und ihrer Schmelzantagonisten im computergesteuerten Kausimulator
-
I. Krejci, L.L. Heinzmann, and F. Lutz Verschleiss von Schmelz, Amalgam und ihrer Schmelzantagonisten im computergesteuerten Kausimulator Schweiz Monatsschr Zahnmed 100 1990 11 15
-
(1990)
Schweiz Monatsschr Zahnmed
, vol.100
, pp. 11-15
-
-
Krejci, I.1
Heinzmann, L.L.2
Lutz, F.3
-
5
-
-
0032103009
-
Bruxing-type dental wear simulator for ranking of dental restorative materials
-
S.H. Teoh, L.F.K.L. Ong, A.U.J. Yap, and G.W. Hastings Bruxing-type dental wear simulator for ranking of dental restorative materials J Biomed Mater Res 43 1998 175 183
-
(1998)
J Biomed Mater Res
, vol.43
, pp. 175-183
-
-
Teoh, S.H.1
Ong, L.F.K.L.2
Yap, A.U.J.3
Hastings, G.W.4
-
6
-
-
30344448471
-
In-vitro simulation of intraoral loading parameters. IADR/CED Berlin 1996
-
M. Rosentritt, A. Leibrock, R. Lang, P. Scharnagl, M. Behr, and G. Handel In-vitro simulation of intraoral loading parameters. IADR/CED Berlin 1996 J Dent Res 76 1997 1111
-
(1997)
J Dent Res
, vol.76
, pp. 1111
-
-
Rosentritt, M.1
Leibrock, A.2
Lang, R.3
Scharnagl, P.4
Behr, M.5
Handel, G.6
-
7
-
-
5244225560
-
Device for simulating intraoral loading parameters
-
M. Rosentritt, A. Leibrock, R. Lang, M. Behr, and G. Handel Device for simulating intraoral loading parameters MaterTest 39 1997 77 80
-
(1997)
MaterTest
, vol.39
, pp. 77-80
-
-
Rosentritt, M.1
Leibrock, A.2
Lang, R.3
Behr, M.4
Handel, G.5
-
8
-
-
0030179672
-
Evaluation of composite wear with a new multi-mode oral wear simulator
-
J.R. Condon, and J.L. Ferracane Evaluation of composite wear with a new multi-mode oral wear simulator Dent Mat 12 1996 218 226
-
(1996)
Dent Mat
, vol.12
, pp. 218-226
-
-
Condon, J.R.1
Ferracane, J.L.2
-
9
-
-
0028185520
-
Occlusal wear simulation with the ACTA wear machine
-
A.J. De Gee, and P. Pallav Occlusal wear simulation with the ACTA wear machine J Dent 22 1994 21 27
-
(1994)
J Dent
, vol.22
, pp. 21-27
-
-
De Gee, A.J.1
Pallav, P.2
-
10
-
-
0032223649
-
Mechanical charaterization of dental ceramics by Hertzian contacts
-
I.M. Peterson, A. Pajares, B.R. Lawn, V.P. Thompson, and E.D. Rekow Mechanical charaterization of dental ceramics by Hertzian contacts J Dent Res 77 1998 589 602
-
(1998)
J Dent Res
, vol.77
, pp. 589-602
-
-
Peterson, I.M.1
Pajares, A.2
Lawn, B.R.3
Thompson, V.P.4
Rekow, E.D.5
-
11
-
-
0034439683
-
Life-time limiting strength degradation from contact fatique in dental ceramics
-
Y.G. Jung, I.M. Peterson, D.K. Kim, and B.R. Lawn Life-time limiting strength degradation from contact fatique in dental ceramics J Dent Res 79 2000 722 731
-
(2000)
J Dent Res
, vol.79
, pp. 722-731
-
-
Jung, Y.G.1
Peterson, I.M.2
Kim, D.K.3
Lawn, B.R.4
-
12
-
-
0030276099
-
Fracture resistance of human enamel and three all-ceramic crown systems on extracted teeth
-
S. Scherrer, W.G. De Rijk, and U.C. Belser Fracture resistance of human enamel and three all-ceramic crown systems on extracted teeth In J Prosthodont 6 1996 580 584
-
(1996)
In J Prosthodont
, vol.6
, pp. 580-584
-
-
Scherrer, S.1
De Rijk, W.G.2
Belser, U.C.3
-
13
-
-
0034280714
-
In vitro fracture force and marginal adaptation of ceramic crowns fixed on natural and artificial teeth
-
M. Rosentritt, T. Plein, C. Kolbeck, M. Behr, and G. Handel In vitro fracture force and marginal adaptation of ceramic crowns fixed on natural and artificial teeth Int J Prosthodont 13 2000 387 391
-
(2000)
Int J Prosthodont
, vol.13
, pp. 387-391
-
-
Rosentritt, M.1
Plein, T.2
Kolbeck, C.3
Behr, M.4
Handel, G.5
-
14
-
-
0034264517
-
Structural reliability of alumina-, feldspar-, leucite-, mica and zirconia-based ceramics
-
J. Tinschert, D. Zwerz, R. Marx, and K.J. Anusavice Structural reliability of alumina-, feldspar-, leucite-, mica and zirconia-based ceramics J Dent 28 2000 529 535
-
(2000)
J Dent
, vol.28
, pp. 529-535
-
-
Tinschert, J.1
Zwerz, D.2
Marx, R.3
Anusavice, K.J.4
-
15
-
-
0141433630
-
Simulation of physiological tooth mobility in in-vitro stress examination of dental restorations in the masticator
-
P. Scharnagl, M. Behr, M. Rosentritt, A. Leibrock, and G. Handel Simulation of physiological tooth mobility in in-vitro stress examination of dental restorations in the masticator J Dent Res 77 1998 1260 431
-
(1998)
J Dent Res
, vol.77
, pp. 1260
-
-
Scharnagl, P.1
Behr, M.2
Rosentritt, M.3
Leibrock, A.4
Handel, G.5
-
16
-
-
0036560045
-
Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures
-
W. Oh, and K.J. Anusavice Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures J Prostheth Dent 87 2002 536 542
-
(2002)
J Prostheth Dent
, vol.87
, pp. 536-542
-
-
Oh, W.1
Anusavice, K.J.2
-
17
-
-
0033278142
-
Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure
-
O. Hidaka, M. Iwasaki, M. Saito, and T. Morimoto Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure J Dent Res 78 1999 1336 1344
-
(1999)
J Dent Res
, vol.78
, pp. 1336-1344
-
-
Hidaka, O.1
Iwasaki, M.2
Saito, M.3
Morimoto, T.4
-
18
-
-
0031172402
-
Forces and moments generated at the dental incisors during biting in humans
-
T.W.P. Kotioth, T.W. Waldron, A. Versluis, and K. Schulte Forces and moments generated at the dental incisors during biting in humans J Biomech 39 1997 631 633
-
(1997)
J Biomech
, vol.39
, pp. 631-633
-
-
Kotioth, T.W.P.1
Waldron, T.W.2
Versluis, A.3
Schulte, K.4
-
19
-
-
0141973963
-
Maximale Kaukraft als Berechnungsfaktor zahntechnischer Konstruktionen
-
K.H. Körber, and P. Ludwig Maximale Kaukraft als Berechnungsfaktor zahntechnischer Konstruktionen Dent Lab 31 1983 55 60
-
(1983)
Dent Lab
, vol.31
, pp. 55-60
-
-
Körber, K.H.1
Ludwig, P.2
-
20
-
-
2342496788
-
Überlebensraten von IPS Empress 2-Vollkeramikkronen und -brücken: Drei-Jahres-Ergebnisse
-
D. Zimmer, T. Gerds, and J.R. Strub Überlebensraten von IPS Empress 2-Vollkeramikkronen und -brücken: Drei-Jahres-Ergebnisse Schweiz Monatschr Zahnmed 114 2004 115 119
-
(2004)
Schweiz Monatschr Zahnmed
, vol.114
, pp. 115-119
-
-
Zimmer, D.1
Gerds, T.2
Strub, J.R.3
-
21
-
-
0032601521
-
A clinical investigation on three-unit fixed partial dentures fabricated with a lithium disilicate glass-ceramic
-
J.A. Sorensen, M. Cruz, W.T. Mito, O. Raffeiner, H.R. Meredith, and H.P. Foser A clinical investigation on three-unit fixed partial dentures fabricated with a lithium disilicate glass-ceramic Prac Periodontics Aesthet Dent 11 1999 95 106
-
(1999)
Prac Periodontics Aesthet Dent
, vol.11
, pp. 95-106
-
-
Sorensen, J.A.1
Cruz, M.2
Mito, W.T.3
Raffeiner, O.4
Meredith, H.R.5
Foser, H.P.6
-
22
-
-
3843142970
-
Two-year clinical evaluation of crowns and bridges made of IPS empress 2
-
D. Edelhoff, J. Brauner, H. Spiekermann, and M. Yildirim Two-year clinical evaluation of crowns and bridges made of IPS empress 2 J Dent Res 2002 2584
-
(2002)
J Dent Res
, pp. 2584
-
-
Edelhoff, D.1
Brauner, J.2
Spiekermann, H.3
Yildirim, M.4
-
23
-
-
0027604308
-
Survival rate of in-ceram restorations
-
L. Pröbster Survival rate of in-ceram restorations Int J Proshtodont 6 1993 259 263
-
(1993)
Int J Proshtodont
, vol.6
, pp. 259-263
-
-
Pröbster, L.1
-
24
-
-
0035408488
-
Five-year evaluation of posterior all-ceramic three-unit (in-ceram) FPDs
-
P.V. Steyern, O. Jönsson, and K. Nilner Five-year evaluation of posterior all-ceramic three-unit (in-ceram) FPDs Int J Proshtodont 14 2001 379 384
-
(2001)
Int J Proshtodont
, vol.14
, pp. 379-384
-
-
Steyern, P.V.1
Jönsson, O.2
Nilner, K.3
-
25
-
-
0034158297
-
Comparison of failure rates of adhesive-fixed partial dentures for in vivo and in vitro studies
-
M. Behr, U. Hindellang, M. Rosentritt, R. Lang, and G. Handel Comparison of failure rates of adhesive-fixed partial dentures for in vivo and in vitro studies Clin Oral Invest 4 2000 25 30
-
(2000)
Clin Oral Invest
, vol.4
, pp. 25-30
-
-
Behr, M.1
Hindellang, U.2
Rosentritt, M.3
Lang, R.4
Handel, G.5
|