메뉴 건너뛰기




Volumn 22, Issue 2, 2006, Pages 176-182

Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures

Author keywords

Artificial mouth; Artificial periodontium; Masticator; Oral stress simulation

Indexed keywords

CERAMIC MATERIALS; COMPUTER SIMULATION; DENTAL PROSTHESES; FRACTURE; FRACTURE TOUGHNESS; MASTICATION; STRESS ANALYSIS;

EID: 30344459124     PISSN: 01095641     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.dental.2005.04.024     Document Type: Article
Times cited : (176)

References (25)
  • 1
    • 0020688695 scopus 로고
    • Developement of an artificial oral environment for the testing of dental restoratives: Bi-axial force and movement control
    • R. DeLong, and W.H. Douglas Developement of an artificial oral environment for the testing of dental restoratives: bi-axial force and movement control J Dent Res 62 1982 32 36
    • (1982) J Dent Res , vol.62 , pp. 32-36
    • Delong, R.1    Douglas, W.H.2
  • 2
    • 0026142466 scopus 로고
    • An artificial oral environment for testing dental materials
    • R. DeLong, and W.H. Douglas An artificial oral environment for testing dental materials IEEE Trans Biomater Eng 4 1991 339 345
    • (1991) IEEE Trans Biomater Eng , vol.4 , pp. 339-345
    • Delong, R.1    Douglas, W.H.2
  • 3
  • 4
    • 5244299716 scopus 로고
    • Verschleiss von Schmelz, Amalgam und ihrer Schmelzantagonisten im computergesteuerten Kausimulator
    • I. Krejci, L.L. Heinzmann, and F. Lutz Verschleiss von Schmelz, Amalgam und ihrer Schmelzantagonisten im computergesteuerten Kausimulator Schweiz Monatsschr Zahnmed 100 1990 11 15
    • (1990) Schweiz Monatsschr Zahnmed , vol.100 , pp. 11-15
    • Krejci, I.1    Heinzmann, L.L.2    Lutz, F.3
  • 5
    • 0032103009 scopus 로고    scopus 로고
    • Bruxing-type dental wear simulator for ranking of dental restorative materials
    • S.H. Teoh, L.F.K.L. Ong, A.U.J. Yap, and G.W. Hastings Bruxing-type dental wear simulator for ranking of dental restorative materials J Biomed Mater Res 43 1998 175 183
    • (1998) J Biomed Mater Res , vol.43 , pp. 175-183
    • Teoh, S.H.1    Ong, L.F.K.L.2    Yap, A.U.J.3    Hastings, G.W.4
  • 8
    • 0030179672 scopus 로고    scopus 로고
    • Evaluation of composite wear with a new multi-mode oral wear simulator
    • J.R. Condon, and J.L. Ferracane Evaluation of composite wear with a new multi-mode oral wear simulator Dent Mat 12 1996 218 226
    • (1996) Dent Mat , vol.12 , pp. 218-226
    • Condon, J.R.1    Ferracane, J.L.2
  • 9
    • 0028185520 scopus 로고
    • Occlusal wear simulation with the ACTA wear machine
    • A.J. De Gee, and P. Pallav Occlusal wear simulation with the ACTA wear machine J Dent 22 1994 21 27
    • (1994) J Dent , vol.22 , pp. 21-27
    • De Gee, A.J.1    Pallav, P.2
  • 11
    • 0034439683 scopus 로고    scopus 로고
    • Life-time limiting strength degradation from contact fatique in dental ceramics
    • Y.G. Jung, I.M. Peterson, D.K. Kim, and B.R. Lawn Life-time limiting strength degradation from contact fatique in dental ceramics J Dent Res 79 2000 722 731
    • (2000) J Dent Res , vol.79 , pp. 722-731
    • Jung, Y.G.1    Peterson, I.M.2    Kim, D.K.3    Lawn, B.R.4
  • 12
    • 0030276099 scopus 로고    scopus 로고
    • Fracture resistance of human enamel and three all-ceramic crown systems on extracted teeth
    • S. Scherrer, W.G. De Rijk, and U.C. Belser Fracture resistance of human enamel and three all-ceramic crown systems on extracted teeth In J Prosthodont 6 1996 580 584
    • (1996) In J Prosthodont , vol.6 , pp. 580-584
    • Scherrer, S.1    De Rijk, W.G.2    Belser, U.C.3
  • 13
    • 0034280714 scopus 로고    scopus 로고
    • In vitro fracture force and marginal adaptation of ceramic crowns fixed on natural and artificial teeth
    • M. Rosentritt, T. Plein, C. Kolbeck, M. Behr, and G. Handel In vitro fracture force and marginal adaptation of ceramic crowns fixed on natural and artificial teeth Int J Prosthodont 13 2000 387 391
    • (2000) Int J Prosthodont , vol.13 , pp. 387-391
    • Rosentritt, M.1    Plein, T.2    Kolbeck, C.3    Behr, M.4    Handel, G.5
  • 14
    • 0034264517 scopus 로고    scopus 로고
    • Structural reliability of alumina-, feldspar-, leucite-, mica and zirconia-based ceramics
    • J. Tinschert, D. Zwerz, R. Marx, and K.J. Anusavice Structural reliability of alumina-, feldspar-, leucite-, mica and zirconia-based ceramics J Dent 28 2000 529 535
    • (2000) J Dent , vol.28 , pp. 529-535
    • Tinschert, J.1    Zwerz, D.2    Marx, R.3    Anusavice, K.J.4
  • 15
    • 0141433630 scopus 로고    scopus 로고
    • Simulation of physiological tooth mobility in in-vitro stress examination of dental restorations in the masticator
    • P. Scharnagl, M. Behr, M. Rosentritt, A. Leibrock, and G. Handel Simulation of physiological tooth mobility in in-vitro stress examination of dental restorations in the masticator J Dent Res 77 1998 1260 431
    • (1998) J Dent Res , vol.77 , pp. 1260
    • Scharnagl, P.1    Behr, M.2    Rosentritt, M.3    Leibrock, A.4    Handel, G.5
  • 16
    • 0036560045 scopus 로고    scopus 로고
    • Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures
    • W. Oh, and K.J. Anusavice Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures J Prostheth Dent 87 2002 536 542
    • (2002) J Prostheth Dent , vol.87 , pp. 536-542
    • Oh, W.1    Anusavice, K.J.2
  • 17
    • 0033278142 scopus 로고    scopus 로고
    • Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure
    • O. Hidaka, M. Iwasaki, M. Saito, and T. Morimoto Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure J Dent Res 78 1999 1336 1344
    • (1999) J Dent Res , vol.78 , pp. 1336-1344
    • Hidaka, O.1    Iwasaki, M.2    Saito, M.3    Morimoto, T.4
  • 18
    • 0031172402 scopus 로고    scopus 로고
    • Forces and moments generated at the dental incisors during biting in humans
    • T.W.P. Kotioth, T.W. Waldron, A. Versluis, and K. Schulte Forces and moments generated at the dental incisors during biting in humans J Biomech 39 1997 631 633
    • (1997) J Biomech , vol.39 , pp. 631-633
    • Kotioth, T.W.P.1    Waldron, T.W.2    Versluis, A.3    Schulte, K.4
  • 19
    • 0141973963 scopus 로고
    • Maximale Kaukraft als Berechnungsfaktor zahntechnischer Konstruktionen
    • K.H. Körber, and P. Ludwig Maximale Kaukraft als Berechnungsfaktor zahntechnischer Konstruktionen Dent Lab 31 1983 55 60
    • (1983) Dent Lab , vol.31 , pp. 55-60
    • Körber, K.H.1    Ludwig, P.2
  • 20
    • 2342496788 scopus 로고    scopus 로고
    • Überlebensraten von IPS Empress 2-Vollkeramikkronen und -brücken: Drei-Jahres-Ergebnisse
    • D. Zimmer, T. Gerds, and J.R. Strub Überlebensraten von IPS Empress 2-Vollkeramikkronen und -brücken: Drei-Jahres-Ergebnisse Schweiz Monatschr Zahnmed 114 2004 115 119
    • (2004) Schweiz Monatschr Zahnmed , vol.114 , pp. 115-119
    • Zimmer, D.1    Gerds, T.2    Strub, J.R.3
  • 22
    • 3843142970 scopus 로고    scopus 로고
    • Two-year clinical evaluation of crowns and bridges made of IPS empress 2
    • D. Edelhoff, J. Brauner, H. Spiekermann, and M. Yildirim Two-year clinical evaluation of crowns and bridges made of IPS empress 2 J Dent Res 2002 2584
    • (2002) J Dent Res , pp. 2584
    • Edelhoff, D.1    Brauner, J.2    Spiekermann, H.3    Yildirim, M.4
  • 23
    • 0027604308 scopus 로고
    • Survival rate of in-ceram restorations
    • L. Pröbster Survival rate of in-ceram restorations Int J Proshtodont 6 1993 259 263
    • (1993) Int J Proshtodont , vol.6 , pp. 259-263
    • Pröbster, L.1
  • 24
    • 0035408488 scopus 로고    scopus 로고
    • Five-year evaluation of posterior all-ceramic three-unit (in-ceram) FPDs
    • P.V. Steyern, O. Jönsson, and K. Nilner Five-year evaluation of posterior all-ceramic three-unit (in-ceram) FPDs Int J Proshtodont 14 2001 379 384
    • (2001) Int J Proshtodont , vol.14 , pp. 379-384
    • Steyern, P.V.1    Jönsson, O.2    Nilner, K.3
  • 25
    • 0034158297 scopus 로고    scopus 로고
    • Comparison of failure rates of adhesive-fixed partial dentures for in vivo and in vitro studies
    • M. Behr, U. Hindellang, M. Rosentritt, R. Lang, and G. Handel Comparison of failure rates of adhesive-fixed partial dentures for in vivo and in vitro studies Clin Oral Invest 4 2000 25 30
    • (2000) Clin Oral Invest , vol.4 , pp. 25-30
    • Behr, M.1    Hindellang, U.2    Rosentritt, M.3    Lang, R.4    Handel, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.