메뉴 건너뛰기




Volumn 34, Issue 1, 2007, Pages 315-327

Performance of a high fill factor, indirect detection prototype flat-panel imager for mammography

Author keywords

Active matrix flat panel imager; Cascaded systems model; Continuous photodiode; Detective quantum efficiency; Digital mammography

Indexed keywords

ADDITIVE NOISE; CESIUM IODIDE; EFFICIENCY; FOOD ADDITIVES; IMAGE RESOLUTION; IONIZATION; MAMMOGRAPHY; OPTICAL TRANSFER FUNCTION; PHOTODIODES; PIXELS; SCINTILLATION COUNTERS;

EID: 33845964617     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2403967     Document Type: Article
Times cited : (44)

References (58)
  • 2
    • 0041875182 scopus 로고    scopus 로고
    • Measurements on a full-field digital mammography system with a photon counting crystalline silicon detector
    • M. Lundqvist, M. Danielsson, B. Cederstrom, V. Chmill, A. Chuntonov, and M. Aslund, " Measurements on a full-field digital mammography system with a photon counting crystalline silicon detector., " Proc. SPIE 5030, 547-552 (2003).
    • (2003) Proc. SPIE , vol.5030 , pp. 547-552
    • Lundqvist, M.1    Danielsson, M.2    Cederstrom, B.3    Chmill, V.4    Chuntonov, A.5    Aslund, M.6
  • 4
    • 31844442646 scopus 로고    scopus 로고
    • A new CMOS-based digital imaging detector for Applications in Mammography
    • M. A. Baysal and E. Toker, " A new CMOS-based digital imaging detector for Applications in Mammography., " Proc. SPIE 5923, 1-11 (2005).
    • (2005) Proc. SPIE , vol.5923 , pp. 1-11
    • Baysal, M.A.1    Toker, E.2
  • 7
    • 23844489914 scopus 로고    scopus 로고
    • Detector evaluation of a prototype amorphous selenium-based full field digital mammography system
    • J. L. Jesneck, R. S. Saunders, E. Samei, J. Q. Xia, and J. Y. Lo, " Detector evaluation of a prototype amorphous selenium-based full field digital mammography system., " Proc. SPIE 5745, 478-485 (2005).
    • (2005) Proc. SPIE , vol.5745 , pp. 478-485
    • Jesneck, J.L.1    Saunders, R.S.2    Samei, E.3    Xia, J.Q.4    Lo, J.Y.5
  • 8
    • 0037321857 scopus 로고    scopus 로고
    • Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: Characterization of a small area prototype detector
    • W. Zhao, W. G. Ji, A. Debrie, and J. A. Rowlands, " Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: Characterization of a small area prototype detector., " Med. Phys. 30, 254-263 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 254-263
    • Zhao, W.1    Ji, W.G.2    Debrie, A.3    Rowlands, J.A.4
  • 9
    • 12344251753 scopus 로고    scopus 로고
    • Digital mammography
    • E. D. Pisano and M. J. Yaffe, " Digital mammography., " Radiology 234, 353-362 (2005).
    • (2005) Radiology , vol.234 , pp. 353-362
    • Pisano, E.D.1    Yaffe, M.J.2
  • 12
    • 0036703710 scopus 로고    scopus 로고
    • A dual-energy subtraction technique for microcalcification imaging in digital mammography: A signal-to-noise analysis
    • M. R. Lemacks, S. C. Kappadath, C. C. Shaw, X. Liu, and G. J. Whitman, " A dual-energy subtraction technique for microcalcification imaging in digital mammography: A signal-to-noise analysis., " Med. Phys. 29, 1739-1751 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1739-1751
    • Lemacks, M.R.1    Kappadath, S.C.2    Shaw, C.C.3    Liu, X.4    Whitman, G.J.5
  • 14
    • 0035999405 scopus 로고    scopus 로고
    • Cone-beam volume CT breast imaging: Feasibility study
    • B. Chen and R. Ning, " Cone-beam volume CT breast imaging: Feasibility study., " Med. Phys. 29, 755-770 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 755-770
    • Chen, B.1    Ning, R.2
  • 15
    • 0035190741 scopus 로고    scopus 로고
    • Dedicated breast CT: Radiation dose and image quality evaluation
    • J. M. Boone, T. R. Nelson, K. K. Lindfors, and J. A. Seibert, " Dedicated breast CT: Radiation dose and image quality evaluation., " Radiology 221, 657-667 (2001).
    • (2001) Radiology , vol.221 , pp. 657-667
    • Boone, J.M.1    Nelson, T.R.2    Lindfors, K.K.3    Seibert, J.A.4
  • 16
    • 3042639544 scopus 로고    scopus 로고
    • Enhanced a-SiCsI -based flat-panel x-ray detector for mammography
    • J. Shaw, D. Albagli, and C.-Y. Wei, " Enhanced a-SiCsI -based flat-panel x-ray detector for mammography., " Proc. SPIE 5368, 370-378 (2004).
    • (2004) Proc. SPIE , vol.5368 , pp. 370-378
    • Shaw, J.1    Albagli, D.2    Wei, C.-Y.3
  • 17
    • 0034868015 scopus 로고    scopus 로고
    • Evaluation of direct detection and indirect detection active matrix flat-panel imagers (AMFPIs) for digital mammography
    • K.-W. Jee, L. E. Antonuk, Y. El-Mohri, M. Maolinbay, and Q. Zhao, " Evaluation of direct detection and indirect detection active matrix flat-panel imagers (AMFPIs) for digital mammography., " Proc. SPIE 4320, 13-23 (2001).
    • (2001) Proc. SPIE , vol.4320 , pp. 13-23
    • Jee, K.-W.1    Antonuk, L.E.2    El-Mohri, Y.3    Maolinbay, M.4    Zhao, Q.5
  • 20
    • 0032779518 scopus 로고    scopus 로고
    • Full-field digital mammography designed as a complete system
    • S. Muller, " Full-field digital mammography designed as a complete system., " Eur. J. Radiol. 31, 25-34 (1999).
    • (1999) Eur. J. Radiol. , vol.31 , pp. 25-34
    • Muller, S.1
  • 21
    • 3042637402 scopus 로고    scopus 로고
    • Performance analysis of a 127-micron pixel large-area TFT/photodiode array with boosted fill factor
    • R. L. Weisfield, W. Yao, T. Speaker, K. Zhou, R. E. Colbeth, and C. Proano, " Performance analysis of a 127-micron pixel large-area TFT/photodiode array with boosted fill factor., " Proc. SPIE 5368, 338-348 (2004).
    • (2004) Proc. SPIE , vol.5368 , pp. 338-348
    • Weisfield, R.L.1    Yao, W.2    Speaker, T.3    Zhou, K.4    Colbeth, R.E.5    Proano, C.6
  • 22
    • 33845937545 scopus 로고    scopus 로고
    • W. Yao, dpiX (private communication, 2006).
    • (2006)
    • Yao, W.1
  • 25
    • 0028215328 scopus 로고
    • A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems
    • I. A. Cunningham, M. S. Westmore, and A. Fenster, " A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems., " Med. Phys. 21, 417-427 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 417-427
    • Cunningham, I.A.1    Westmore, M.S.2    Fenster, A.3
  • 26
    • 0031805838 scopus 로고    scopus 로고
    • Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology
    • J. H. Siewerdsen, L. E. Antonuk, Y. El-Mohri, J. Yorkston, W. Huang, and I. A. Cunningham, " Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology., " Med. Phys. 25, 614-628 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 614-628
    • Siewerdsen, J.H.1    Antonuk, L.E.2    El-Mohri, Y.3    Yorkston, J.4    Huang, W.5    Cunningham, I.A.6
  • 27
    • 0035875306 scopus 로고    scopus 로고
    • Crosstalk and lateral conduction effects in continuous-sensor amorphous silicon imagers
    • M. Mulato, S. Ready, K. Van Schuylenbergh, J. P. Lu, and R. A. Street, " Crosstalk and lateral conduction effects in continuous-sensor amorphous silicon imagers., " J. Appl. Phys. 89, 8193-8201 (2001).
    • (2001) J. Appl. Phys. , vol.89 , pp. 8193-8201
    • Mulato, M.1    Ready, S.2    Van Schuylenbergh, K.3    Lu, J.P.4    Street, R.A.5
  • 28
    • 0031704492 scopus 로고    scopus 로고
    • Digital radiology using active matrix readout of amorphous selenium: Geometrical and effective fill factors
    • G. Pang, W. Zhao, and J. A. Rowlands, " Digital radiology using active matrix readout of amorphous selenium: Geometrical and effective fill factors., " Med. Phys. 25, 1636-1646 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1636-1646
    • Pang, G.1    Zhao, W.2    Rowlands, J.A.3
  • 30
    • 0346482205 scopus 로고    scopus 로고
    • Lateral conduction in structured amorphous silicon p(+)-i-n(+) photodiodes
    • F. Lemmi, J. T. Rahn, and R. A. Street, " Lateral conduction in structured amorphous silicon p(+)-i-n(+) photodiodes., " J. Non-Cryst. Solids 266, 1203-1207 (2000).
    • (2000) J. Non-Cryst. Solids , vol.266 , pp. 1203-1207
    • Lemmi, F.1    Rahn, J.T.2    Street, R.A.3
  • 31
    • 0000194699 scopus 로고    scopus 로고
    • Simulated and measured data-line parasitic capacitance of amorphous silicon large-area image sensor arrays
    • M. Mulato, J. P. Lu, and R. A. Street, " Simulated and measured data-line parasitic capacitance of amorphous silicon large-area image sensor arrays., " J. Appl. Phys. 89, 638-647 (2001).
    • (2001) J. Appl. Phys. , vol.89 , pp. 638-647
    • Mulato, M.1    Lu, J.P.2    Street, R.A.3
  • 32
    • 0001017879 scopus 로고
    • Thermal generation currents in hydrogenated amorphous-silicon p-i-n structures
    • R. A. Street, " Thermal generation currents in hydrogenated amorphous-silicon p-i-n structures., " Appl. Phys. Lett. 57, 1334-1336 (1990).
    • (1990) Appl. Phys. Lett. , vol.57 , pp. 1334-1336
    • Street, R.A.1
  • 34
    • 0031016807 scopus 로고    scopus 로고
    • Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation
    • L. E. Antonuk, Y. El-Mohri, J. H. Siewerdsen, J. Yorkston, W. Huang, V. E. Scarpine, and R. A. Street, " Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation., Med. Phys. 24, 51-70 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 51-70
    • Antonuk, L.E.1    El-Mohri, Y.2    Siewerdsen, J.H.3    Yorkston, J.4    Huang, W.5    Scarpine, V.E.6    Street, R.A.7
  • 40
    • 0033864255 scopus 로고    scopus 로고
    • A quantitative investigation of additive noise reduction for active matrix flat-panel imagers using compensation lines
    • Y. El-Mohri, L. E. Antonuk, Q. Zhao, M. Maolinbay, X. Rong, K. W. Jee, S. Nassif, and C. Cionca, " A quantitative investigation of additive noise reduction for active matrix flat-panel imagers using compensation lines., " Med. Phys. 27, 1855-1864 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 1855-1864
    • El-Mohri, Y.1    Antonuk, L.E.2    Zhao, Q.3    Maolinbay, M.4    Rong, X.5    Jee, K.W.6    Nassif, S.7    Cionca, C.8
  • 41
    • 0035661107 scopus 로고    scopus 로고
    • Determination of the detective quantum efficiency of a prototype, megavoltage indirect detection, active matrix flat-panel imager
    • Y. El-Mohri, K. W. Jee, L. E. Antonuk, M. Maolinbay, and Q. Zhao, " Determination of the detective quantum efficiency of a prototype, megavoltage indirect detection, active matrix flat-panel imager., " Med. Phys. 28, 2538-2550 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 2538-2550
    • El-Mohri, Y.1    Jee, K.W.2    Antonuk, L.E.3    Maolinbay, M.4    Zhao, Q.5
  • 43
    • 0021687319 scopus 로고
    • Investigation of basic imaging properties in digital radiography. 2. Noise Wiener spectrum
    • M. L. Giger, K. Doi, and C. E. Metz, " Investigation of basic imaging properties in digital radiography. 2. Noise Wiener spectrum., " Med. Phys. 11, 797-805 (1984).
    • (1984) Med. Phys. , vol.11 , pp. 797-805
    • Giger, M.L.1    Doi, K.2    Metz, C.E.3
  • 44
    • 0028308573 scopus 로고
    • Analysis of the spatial-frequency-dependent DQE of optically coupled digital mammography detectors
    • A. D. Maidment and M. J. Yaffe, " Analysis of the spatial-frequency-dependent DQE of optically coupled digital mammography detectors., " Med. Phys. 21, 721-729 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 721-729
    • Maidment, A.D.1    Yaffe, M.J.2
  • 46
  • 47
    • 0023339134 scopus 로고
    • Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms
    • M. Rabbani, R. Shaw, and R. Vanmetter, " Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms., " J. Opt. Soc. Am. A Opt. Image Sci. Vis 4, 895-901 (1987).
    • (1987) J. Opt. Soc. Am. a Opt. Image Sci. Vis , vol.4 , pp. 895-901
    • Rabbani, M.1    Shaw, R.2    Vanmetter, R.3
  • 48
    • 0037962475 scopus 로고    scopus 로고
    • System performance of a prototype flat-panel imager operated under mammographic conditions
    • K.-W. Jee, L. E. Antonuk, Y. El-Mohri, and Q. Zhao, " System performance of a prototype flat-panel imager operated under mammographic conditions., " Med. Phys. 30, 1874-1890 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 1874-1890
    • Jee, K.-W.1    Antonuk, L.E.2    El-Mohri, Y.3    Zhao, Q.4
  • 49
    • 0031466296 scopus 로고    scopus 로고
    • Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography
    • J. M. Boone, T. R. Fewell, and R. J. Jennings, " Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography., " Med. Phys. 24, 1863-1874 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1863-1874
    • Boone, J.M.1    Fewell, T.R.2    Jennings, R.J.3
  • 50
    • 0032403040 scopus 로고    scopus 로고
    • Spectral modeling and compilation of quantum fluence in radiography and mammography
    • J. M. Boone, " Spectral modeling and compilation of quantum fluence in radiography and mammography., " Proc. SPIE 3336, 592-601 (1998).
    • (1998) Proc. SPIE , vol.3336 , pp. 592-601
    • Boone, J.M.1
  • 52
    • 0036032147 scopus 로고    scopus 로고
    • Approaching the theoretical x-ray sensitivity with HgI2 direct detection image sensors
    • R. A. Street, S. Ready, L. Melekhov, J. Ho, A. Zuck, and B. Breen, " Approaching the theoretical x-ray sensitivity with HgI2 direct detection image sensors., " Proc. SPIE 4682, 414-422 (2002).
    • (2002) Proc. SPIE , vol.4682 , pp. 414-422
    • Street, R.A.1    Ready, S.2    Melekhov, L.3    Ho, J.4    Zuck, A.5    Breen, B.6
  • 53
    • 23844518392 scopus 로고    scopus 로고
    • Optimization of operational conditions for direct digital mammography detectors for digital tomosynthesis
    • W. Zhao, R. Deych, and E. Dolazza, " Optimization of operational conditions for direct digital mammography detectors for digital tomosynthesis., " Proc. SPIE 5745, 1272-1281 (2005).
    • (2005) Proc. SPIE , vol.5745 , pp. 1272-1281
    • Zhao, W.1    Deych, R.2    Dolazza, E.3
  • 54
    • 10844262443 scopus 로고    scopus 로고
    • Design and performance of a low noise, 128-channel ASIC preamplifier for readout of active matrix flat-panel imaging arrays
    • M. Maolinbay, T. Zimmerman, R. J. Yarema, L. E. Antonuk, Y. El-Mohri, and M. Yeakey, " Design and performance of a low noise, 128-channel ASIC preamplifier for readout of active matrix flat-panel imaging arrays., " Nucl. Instrum. Methods Phys. Res. A 485, 661-675 (2002).
    • (2002) Nucl. Instrum. Methods Phys. Res. a , vol.485 , pp. 661-675
    • Maolinbay, M.1    Zimmerman, T.2    Yarema, R.J.3    Antonuk, L.E.4    El-Mohri, Y.5    Yeakey, M.6
  • 55
    • 23844474189 scopus 로고    scopus 로고
    • Investigation of strategies to achieve optimal DQE performance from indirect detection, active matrix, flat-panel imagers (AMFPIs) through novel pixel amplification architectures
    • L. E. Antonuk, Y. Li, H. Du, Y. El-Mohri, Q. Zhao, J. Yamamoto, A. R. Sawant, Y. Wang, Z. Su, J. P. Lu, R. A. Street, R. L. Weisfield, and B. Yao, " Investigation of strategies to achieve optimal DQE performance from indirect detection, active matrix, flat-panel imagers (AMFPIs) through novel pixel amplification architectures., " Proc. SPIE 5745, 18-31 (2005).
    • (2005) Proc. SPIE , vol.5745 , pp. 18-31
    • Antonuk, L.E.1    Li, Y.2    Du, H.3    El-Mohri, Y.4    Zhao, Q.5    Yamamoto, J.6    Sawant, A.R.7    Wang, Y.8    Su, Z.9    Lu, J.P.10    Street, R.A.11    Weisfield, R.L.12    Yao, B.13
  • 56
    • 33645783175 scopus 로고    scopus 로고
    • Effect of x-ray irradiation on polycrystalline silicon thin-film transistors
    • Y. Li, L. E. Antonuk, Y. El-Mohri, Q. Zhao, H. Du, A. Sawant, and Y. Wang, " Effect of x-ray irradiation on polycrystalline silicon thin-film transistors., " J. Appl. Phys. 99, 64501 (1-7) (2006).
    • (2006) J. Appl. Phys. , vol.99 , pp. 64501
    • Li, Y.1    Antonuk, L.E.2    El-Mohri, Y.3    Zhao, Q.4    Du, H.5    Sawant, A.6    Wang, Y.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.