메뉴 건너뛰기




Volumn 36, Issue 6, 2003, Pages 471-481

Tandem mass spectrometry in the clinical chemistry laboratory

Author keywords

[No Author keywords available]

Indexed keywords

ATMOSPHERIC PRESSURE; CHEMICAL ANALYSIS; CHEMICAL STRUCTURE; CLINICAL LABORATORY; COST EFFECTIVENESS ANALYSIS; DRUG MONITORING; IONIZATION; MASS SPECTROMETRY; MOLECULAR GENETICS; PRIORITY JOURNAL; PROTEIN ANALYSIS; REVIEW; TANDEM MASS SPECTROMETRY; TOXICOLOGY;

EID: 0042261796     PISSN: 00099120     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0009-9120(03)00105-X     Document Type: Review
Times cited : (56)

References (87)
  • 2
    • 0000217562 scopus 로고
    • Electrospray and Taylor-Cone Theory, Doles Beam of Macromolecules at last
    • Wilm M.S., Mann M. Electrospray and Taylor-Cone Theory, Doles Beam of Macromolecules at last. Intl J of Mass Spectr and Ion Process. 136:1994;167-180.
    • (1994) Intl J of Mass Spectr and Ion Process , vol.136 , pp. 167-180
    • Wilm, M.S.1    Mann, M.2
  • 3
    • 0035162994 scopus 로고    scopus 로고
    • Determination of serum cortisol by isotope-dilution liquid-chromatography electrospray ionization tandem mass spectrometry with on-line extraction
    • Vogeser M., Briegel J., Jacob K. Determination of serum cortisol by isotope-dilution liquid-chromatography electrospray ionization tandem mass spectrometry with on-line extraction. Clin Chem Lab Med. 39:2001;944-947.
    • (2001) Clin Chem Lab Med , vol.39 , pp. 944-947
    • Vogeser, M.1    Briegel, J.2    Jacob, K.3
  • 4
    • 0033857288 scopus 로고    scopus 로고
    • Oligosaccharide profiling: The facile detection of mono-, di- and oligosaccharides by electrospray orthogonal time-of-flight mass spectrometry using 3-aminophenylboronic acid derivatization
    • Williams D., Lee T.D., Dinh N., Young M.K. Oligosaccharide profiling the facile detection of mono-, di- and oligosaccharides by electrospray orthogonal time-of-flight mass spectrometry using 3-aminophenylboronic acid derivatization . Rapid Commun Mass Spectrom. 14:2000;1530-1537.
    • (2000) Rapid Commun Mass Spectrom , vol.14 , pp. 1530-1537
    • Williams, D.1    Lee, T.D.2    Dinh, N.3    Young, M.K.4
  • 5
    • 0033626535 scopus 로고    scopus 로고
    • Alkyldimethylaminoethyl ester iodides for improved analysis of fatty acids by electrospray ionization tandem mass spectrometry
    • Johnson D.W. Alkyldimethylaminoethyl ester iodides for improved analysis of fatty acids by electrospray ionization tandem mass spectrometry. Rapid Commun Mass Spectrom. 14:2000;2019-2024.
    • (2000) Rapid Commun Mass Spectrom , vol.14 , pp. 2019-2024
    • Johnson, D.W.1
  • 6
    • 0028834343 scopus 로고
    • LC/MS/MS of carbohydrates with postcolumn addition of metal chlorides using a triaxial electrospray probe
    • Kohler M., Leary J.A. LC/MS/MS of carbohydrates with postcolumn addition of metal chlorides using a triaxial electrospray probe. Anal Chem. 67:1995;3501-3508.
    • (1995) Anal Chem , vol.67 , pp. 3501-3508
    • Kohler, M.1    Leary, J.A.2
  • 7
    • 0037236244 scopus 로고    scopus 로고
    • Metal ion complexes in the structural analysis of phospholipids by electrospray ionization tandem mass spectrometry
    • Ho Y.P., Huang P.C., Deng K.H. Metal ion complexes in the structural analysis of phospholipids by electrospray ionization tandem mass spectrometry. Rapid Commun Mass Spectrom. 17:2003;114-121.
    • (2003) Rapid Commun Mass Spectrom , vol.17 , pp. 114-121
    • Ho, Y.P.1    Huang, P.C.2    Deng, K.H.3
  • 8
    • 0030583842 scopus 로고    scopus 로고
    • Carboxylate and amine terminus directed fragmentations in gaseous dipeptide complexes with copper (II) and diimine ligands formed by electrospray
    • Gatlin C.L., Rao R.D., Turecek F., Vaisar T. Carboxylate and amine terminus directed fragmentations in gaseous dipeptide complexes with copper (II) and diimine ligands formed by electrospray. Anal Chem. 68:1996;263-270.
    • (1996) Anal Chem , vol.68 , pp. 263-270
    • Gatlin, C.L.1    Rao, R.D.2    Turecek, F.3    Vaisar, T.4
  • 9
    • 0343314923 scopus 로고    scopus 로고
    • Quantitative electrospray ionization mass spectrometric studies of ternary complexes of amino acids with Cu(2+) and phenanthroline
    • Gatlin C.L., Turecek F. Quantitative electrospray ionization mass spectrometric studies of ternary complexes of amino acids with Cu(2+) and phenanthroline. J Mass Spectrom. 35:2000;172-177.
    • (2000) J Mass Spectrom , vol.35 , pp. 172-177
    • Gatlin, C.L.1    Turecek, F.2
  • 10
    • 0000876360 scopus 로고    scopus 로고
    • Electrospray Tandem Mass Spectrometry of Nitrido and Imido Complexes
    • Lau T.C., Wu Z., Wang J., Siu K.W., Guevremont R. Electrospray Tandem Mass Spectrometry of Nitrido and Imido Complexes. Inorg Chem. 35:1996;2169-2170.
    • (1996) Inorg Chem , vol.35 , pp. 2169-2170
    • Lau, T.C.1    Wu, Z.2    Wang, J.3    Siu, K.W.4    Guevremont, R.5
  • 11
    • 0030063263 scopus 로고    scopus 로고
    • Electrospray tandem mass spectrometry of alkali metal-containing anionic complexes of tripeptide
    • Wang J., Ke F., Siu K.W., Guevremont R. Electrospray tandem mass spectrometry of alkali metal-containing anionic complexes of tripeptide. J Mass Spectrom. 31:1996;159-168.
    • (1996) J Mass Spectrom , vol.31 , pp. 159-168
    • Wang, J.1    Ke, F.2    Siu, K.W.3    Guevremont, R.4
  • 13
    • 0033404871 scopus 로고    scopus 로고
    • Interaction between antitumor drugs and a double-stranded oligonucleotide studied by electrospray ionization mass spectrometry
    • Gabelica V., De Pauw E., Rosu F. Interaction between antitumor drugs and a double-stranded oligonucleotide studied by electrospray ionization mass spectrometry. J Mass Spectrom. 34:1999;1328-1337.
    • (1999) J Mass Spectrom , vol.34 , pp. 1328-1337
    • Gabelica, V.1    De Pauw, E.2    Rosu, F.3
  • 14
    • 0035263299 scopus 로고    scopus 로고
    • Electrospray ionization mass spectrometry of oligonucleotide complexes with drugs, metals, and proteins
    • Beck J.L., Colgrave M.L., Ralph S.F., Sheil M.M. Electrospray ionization mass spectrometry of oligonucleotide complexes with drugs, metals, and proteins. Mass Spectrom Rev. 20:2001;61-87.
    • (2001) Mass Spectrom Rev , vol.20 , pp. 61-87
    • Beck, J.L.1    Colgrave, M.L.2    Ralph, S.F.3    Sheil, M.M.4
  • 15
    • 0034839464 scopus 로고    scopus 로고
    • Gas-phase binding of non-covalent protein complexes between bovine pancreatic trypsin inhibitor and its target enzymes studied by electrospray ionization tandem mass spectrometry
    • Nesatyy V.J. Gas-phase binding of non-covalent protein complexes between bovine pancreatic trypsin inhibitor and its target enzymes studied by electrospray ionization tandem mass spectrometry. J Mass Spectrom. 36:2001;950-959.
    • (2001) J Mass Spectrom , vol.36 , pp. 950-959
    • Nesatyy, V.J.1
  • 16
    • 0034905575 scopus 로고    scopus 로고
    • Speciation of low molecular weight Al complexes in serum of CAPD patients
    • Polak T.B., Milacic R., Mitrovic B., Benedik M. Speciation of low molecular weight Al complexes in serum of CAPD patients. J Pharm Biomed Anal. 26:2001;189-201.
    • (2001) J Pharm Biomed Anal , vol.26 , pp. 189-201
    • Polak, T.B.1    Milacic, R.2    Mitrovic, B.3    Benedik, M.4
  • 17
    • 0036099232 scopus 로고    scopus 로고
    • Tandem mass spectrometry of protein-protein complexes: Cytochrome c-cytochrome b5
    • Mauk M.R., Mauk A.G., Chen Y.L., Douglas D.J. Tandem mass spectrometry of protein-protein complexes cytochrome c-cytochrome b5 . J Am Soc Mass Spectrom. 13:2002;59-71.
    • (2002) J Am Soc Mass Spectrom , vol.13 , pp. 59-71
    • Mauk, M.R.1    Mauk, A.G.2    Chen, Y.L.3    Douglas, D.J.4
  • 18
    • 0037067021 scopus 로고    scopus 로고
    • Non-covalent associations of cyclomaltooligosaccharides (cyclodextrins) with carotenoids in water. A study on the alpha- and beta- cyclodextrin/psi, psi-carotene (lycopene) systems by light scattering, ionspray ionization and tandem mass spectrometry
    • Mele A., Mendichi R., Selva A., Molnar P., Toth G. Non-covalent associations of cyclomaltooligosaccharides (cyclodextrins) with carotenoids in water. A study on the alpha- and beta- cyclodextrin/psi, psi-carotene (lycopene) systems by light scattering, ionspray ionization and tandem mass spectrometry. Carbohydr Res. 337:2002;1129-1136.
    • (2002) Carbohydr Res , vol.337 , pp. 1129-1136
    • Mele, A.1    Mendichi, R.2    Selva, A.3    Molnar, P.4    Toth, G.5
  • 19
    • 0029685702 scopus 로고    scopus 로고
    • Analytical properties of the nanoelectrospray ion source
    • Wilm M., Mann M. Analytical properties of the nanoelectrospray ion source. Anal Chem. 68:1996;1-8.
    • (1996) Anal Chem , vol.68 , pp. 1-8
    • Wilm, M.1    Mann, M.2
  • 20
    • 0033168525 scopus 로고    scopus 로고
    • Nanoelectrospray mass spectrometry and precursor ion monitoring for quantitative steroid analysis and attomole sensitivity
    • Chatman K., Hollenbeck T., Hagey L., Vallee M., Purdy R., Weiss F., Siuzdak G. Nanoelectrospray mass spectrometry and precursor ion monitoring for quantitative steroid analysis and attomole sensitivity. Anal Chem. 71:1999;2358-2363.
    • (1999) Anal Chem , vol.71 , pp. 2358-2363
    • Chatman, K.1    Hollenbeck, T.2    Hagey, L.3    Vallee, M.4    Purdy, R.5    Weiss, F.6    Siuzdak, G.7
  • 21
    • 0037214121 scopus 로고    scopus 로고
    • Investigation of matrix effects in bioanalytical high-performance liquid chromatography/tandem mass spectrometric assays: Application to drug discovery
    • Mei H., Hsieh Y., Nardo C., Xu X., Wang S., Ng K., Korfmacher W.A. Investigation of matrix effects in bioanalytical high-performance liquid chromatography/tandem mass spectrometric assays application to drug discovery . Rapid Commun Mass Spectrom. 17:2003;97-103.
    • (2003) Rapid Commun Mass Spectrom , vol.17 , pp. 97-103
    • Mei, H.1    Hsieh, Y.2    Nardo, C.3    Xu, X.4    Wang, S.5    Ng, K.6    Korfmacher, W.A.7
  • 22
    • 0031794872 scopus 로고    scopus 로고
    • Usefulness of the hydrogen-deuterium exchange method in the study of drug metabolism using liquid chromatography-tandem mass spectrometry
    • Ohashi N., Furuuchi S., Yoshikawa M. Usefulness of the hydrogen-deuterium exchange method in the study of drug metabolism using liquid chromatography-tandem mass spectrometry. J Pharm Biomed Anal. 18:1998;325-334.
    • (1998) J Pharm Biomed Anal , vol.18 , pp. 325-334
    • Ohashi, N.1    Furuuchi, S.2    Yoshikawa, M.3
  • 23
    • 0036780767 scopus 로고    scopus 로고
    • Analysis of anticancer drugs and their metabolites by mass spectrometry
    • Blair I.A., Tilve A. Analysis of anticancer drugs and their metabolites by mass spectrometry. Curr Drug Metab. 3:2002;463-480.
    • (2002) Curr Drug Metab , vol.3 , pp. 463-480
    • Blair, I.A.1    Tilve, A.2
  • 24
    • 0036583670 scopus 로고    scopus 로고
    • Current developments in LC-MS for pharmaceutical analysis
    • Lim C.K., Lord G. Current developments in LC-MS for pharmaceutical analysis. Biol Pharm Bull. 25:2002;547-557.
    • (2002) Biol Pharm Bull , vol.25 , pp. 547-557
    • Lim, C.K.1    Lord, G.2
  • 25
    • 0025932410 scopus 로고
    • Mass spectrometry software for biochemical analysis in electrospray and fast atom bombardment modes
    • Watkins P.J., Jardine I., Zhou J.X. Mass spectrometry software for biochemical analysis in electrospray and fast atom bombardment modes. Biochem Soc Trans. 19:1991;957-962.
    • (1991) Biochem Soc Trans , vol.19 , pp. 957-962
    • Watkins, P.J.1    Jardine, I.2    Zhou, J.X.3
  • 26
    • 0033898240 scopus 로고    scopus 로고
    • Advances in mass spectrometry for proteome analysis
    • Chalmers M.J., Gaskell S.J. Advances in mass spectrometry for proteome analysis. Curr Opin Biotechnol. 11:2000;384-390.
    • (2000) Curr Opin Biotechnol , vol.11 , pp. 384-390
    • Chalmers, M.J.1    Gaskell, S.J.2
  • 27
    • 0036731271 scopus 로고    scopus 로고
    • Proteomics without polyacrylamide: Qualitative and quantitative uses of tandem mass spectrometry in proteome analysis
    • Goodlett D.R., Yi E.C. Proteomics without polyacrylamide qualitative and quantitative uses of tandem mass spectrometry in proteome analysis . Funct Integr Genomics. 2:2002;138-153.
    • (2002) Funct Integr Genomics , vol.2 , pp. 138-153
    • Goodlett, D.R.1    Yi, E.C.2
  • 28
    • 0030046793 scopus 로고    scopus 로고
    • Characterization of protein glycosylation by mass spectrometry
    • Burlingame A.L. Characterization of protein glycosylation by mass spectrometry. Curr Opin Biotechnol. 7:1996;4-10.
    • (1996) Curr Opin Biotechnol , vol.7 , pp. 4-10
    • Burlingame, A.L.1
  • 29
    • 0031814440 scopus 로고    scopus 로고
    • High sensitivity analysis of proteins and peptides by capillary electrophoresis-tandem mass spectrometry: Recent developments in technology and applications
    • Figeys D., Aebersold R. High sensitivity analysis of proteins and peptides by capillary electrophoresis-tandem mass spectrometry recent developments in technology and applications . Electrophoresis. 19:1998;885-892.
    • (1998) Electrophoresis , vol.19 , pp. 885-892
    • Figeys, D.1    Aebersold, R.2
  • 30
    • 0033168122 scopus 로고    scopus 로고
    • Identification of proteins in complexes by solid-phase microextraction/multistep elution/capillary electrophoresis/tandem mass spectrometry
    • Tong W., Link A., Eng J.K., Yates J.R. 3rd. Identification of proteins in complexes by solid-phase microextraction/multistep elution/capillary electrophoresis/tandem mass spectrometry. Anal Chem. 71:1999;2270-2278.
    • (1999) Anal Chem , vol.71 , pp. 2270-2278
    • Tong, W.1    Link, A.2    Eng, J.K.3    Yates J.R. III4
  • 31
    • 0342844280 scopus 로고    scopus 로고
    • Capillary electrophoresis and off-line capillary electrophoresis- electrospray ionization quadrupole time-of-flight tandem mass spectrometry of carbohydrates
    • Zamfir A., Konig S., Althoff J., Peter-Katalinc J. Capillary electrophoresis and off-line capillary electrophoresis- electrospray ionization quadrupole time-of-flight tandem mass spectrometry of carbohydrates. J Chromatogr A. 895:2000;291-299.
    • (2000) J Chromatogr A , vol.895 , pp. 291-299
    • Zamfir, A.1    Konig, S.2    Althoff, J.3    Peter-Katalinc, J.4
  • 33
    • 0030033198 scopus 로고    scopus 로고
    • Parent ion scans of unseparated peptide mixtures
    • Matthias W., Gitte N., Matthias M. Parent ion scans of unseparated peptide mixtures. Anal Chem. 68:1996;527-533.
    • (1996) Anal Chem , vol.68 , pp. 527-533
    • Matthias, W.1    Gitte, N.2    Matthias, M.3
  • 34
    • 84987419408 scopus 로고
    • Proposal for a common nomenclature for sequence ions in mass spectra of peptides
    • Roepstorff P., Fohlman J. Proposal for a common nomenclature for sequence ions in mass spectra of peptides. Biomedical Mass Spectrometry. 11:1984;601.
    • (1984) Biomedical Mass Spectrometry , vol.11 , pp. 601
    • Roepstorff, P.1    Fohlman, J.2
  • 35
    • 0030751763 scopus 로고    scopus 로고
    • Screening blood spots for inborn errors of metabolism by electrospray tandem mass spectrometry with a microplate batch process and a computer algorithm for automated flagging of abnormal profiles
    • Rashed M.S., Bucknall M.P., Little D., Awad A., Jacob M., Alamoudi M., Alwattar M., Ozand P.T. Screening blood spots for inborn errors of metabolism by electrospray tandem mass spectrometry with a microplate batch process and a computer algorithm for automated flagging of abnormal profiles. Clin Chem. 43:1997;1129-1141.
    • (1997) Clin Chem , vol.43 , pp. 1129-1141
    • Rashed, M.S.1    Bucknall, M.P.2    Little, D.3    Awad, A.4    Jacob, M.5    Alamoudi, M.6    Alwattar, M.7    Ozand, P.T.8
  • 36
    • 0024121493 scopus 로고
    • Application of continuous-flow liquid chromatography/fast-atom bombardment mass spectrometry to the analysis of diagnostic acylcarnitines in human urine
    • Norwood D.L., Kodo N., Millington D.S. Application of continuous-flow liquid chromatography/fast-atom bombardment mass spectrometry to the analysis of diagnostic acylcarnitines in human urine. Rapid Commun Mass Spectrom. 2:1988;269-272.
    • (1988) Rapid Commun Mass Spectrom , vol.2 , pp. 269-272
    • Norwood, D.L.1    Kodo, N.2    Millington, D.S.3
  • 37
    • 0021176743 scopus 로고
    • Application of high resolution fast atom bombardment and constant B/E ratio linked scanning to the identification and analysis of acylcarnitines in metabolic disease
    • Millington D.S., Roe C.R., Maltby D.A. Application of high resolution fast atom bombardment and constant B/E ratio linked scanning to the identification and analysis of acylcarnitines in metabolic disease. Biomed Mass Spectrom. 11:1984;236-241.
    • (1984) Biomed Mass Spectrom , vol.11 , pp. 236-241
    • Millington, D.S.1    Roe, C.R.2    Maltby, D.A.3
  • 38
    • 0030664016 scopus 로고    scopus 로고
    • Rapid diagnosis of MCAD deficiency: Quantitatively analysis of octanoylcarnitine and other acylcarnitines in newborn blood spots by tandem mass spectrometry
    • Chace D.H., Hillman S.L., Van Hove J.L., Naylor E.W. Rapid diagnosis of MCAD deficiency quantitatively analysis of octanoylcarnitine and other acylcarnitines in newborn blood spots by tandem mass spectrometry . Clin Chem. 43:1997;2106-2113.
    • (1997) Clin Chem , vol.43 , pp. 2106-2113
    • Chace, D.H.1    Hillman, S.L.2    Van Hove, J.L.3    Naylor, E.W.4
  • 39
    • 0027395318 scopus 로고
    • Rapid diagnosis of phenylketonuria by quantitative analysis for phenylalanine and tyrosine in neonatal blood spots by tandem mass spectrometry
    • Chace D.H., Millington D.S., Terada N., Kahler S.G., Roe C.R., Hofman L.F. Rapid diagnosis of phenylketonuria by quantitative analysis for phenylalanine and tyrosine in neonatal blood spots by tandem mass spectrometry. Clin Chem. 39:1993;66-71.
    • (1993) Clin Chem , vol.39 , pp. 66-71
    • Chace, D.H.1    Millington, D.S.2    Terada, N.3    Kahler, S.G.4    Roe, C.R.5    Hofman, L.F.6
  • 40
    • 0028895728 scopus 로고
    • Rapid diagnosis of maple syrup urine disease in blood spots from newborns by tandem mass spectrometry
    • Chace D.H., Hillman S.L., Millington D.S., Kahler S.G., Roe C.R., Naylor E.W. Rapid diagnosis of maple syrup urine disease in blood spots from newborns by tandem mass spectrometry. Clin Chem. 41:1995;62-68.
    • (1995) Clin Chem , vol.41 , pp. 62-68
    • Chace, D.H.1    Hillman, S.L.2    Millington, D.S.3    Kahler, S.G.4    Roe, C.R.5    Naylor, E.W.6
  • 41
    • 0029940590 scopus 로고    scopus 로고
    • Rapid diagnosis of homocystinuria and other hypermethioninemias from newborns' blood spots by tandem mass spectrometry
    • Chace D.H., Hillman S.L., Millington D.S., Kahler S.G., Adam B.W., Levy H.L. Rapid diagnosis of homocystinuria and other hypermethioninemias from newborns' blood spots by tandem mass spectrometry. Clin Chem. 42:1996;349-355.
    • (1996) Clin Chem , vol.42 , pp. 349-355
    • Chace, D.H.1    Hillman, S.L.2    Millington, D.S.3    Kahler, S.G.4    Adam, B.W.5    Levy, H.L.6
  • 42
    • 0034916388 scopus 로고    scopus 로고
    • Neonatal screening for galactosemia by quantitative analysis of hexose monophosphates using tandem mass spectrometry: A retrospective study
    • Jensen U.G., Brandt N.J., Christensen E., Skovby F., Norgaard-Pedersen B., Simonsen H. Neonatal screening for galactosemia by quantitative analysis of hexose monophosphates using tandem mass spectrometry a retrospective study . Clin Chem. 47:2001;1364-1372.
    • (2001) Clin Chem , vol.47 , pp. 1364-1372
    • Jensen, U.G.1    Brandt, N.J.2    Christensen, E.3    Skovby, F.4    Norgaard-Pedersen, B.5    Simonsen, H.6
  • 43
    • 0036149535 scopus 로고    scopus 로고
    • Rapid screening assay of congenital adrenal hyperplasia by measuring 17 alpha-hydroxyprogesterone with high-performance liquid chromatography/electrospray ionization tandem mass spectrometry from dried blood spots
    • Lai C.C., Tsai C.H., Tsai F.J., Wu J.Y., Lin W.D., Lee C.C. Rapid screening assay of congenital adrenal hyperplasia by measuring 17 alpha-hydroxyprogesterone with high-performance liquid chromatography/electrospray ionization tandem mass spectrometry from dried blood spots. J Clin Lab Anal. 16:2002;20-25.
    • (2002) J Clin Lab Anal , vol.16 , pp. 20-25
    • Lai, C.C.1    Tsai, C.H.2    Tsai, F.J.3    Wu, J.Y.4    Lin, W.D.5    Lee, C.C.6
  • 44
    • 0036137877 scopus 로고    scopus 로고
    • Determination of oligosaccharides in Pompe disease by electrospray ionization tandem mass spectrometry
    • Rozaklis T., Ramsay S.L., Whitfield P.D., Ranieri E., Hopwood J.J., Meikle P.J. Determination of oligosaccharides in Pompe disease by electrospray ionization tandem mass spectrometry. Clin Chem. 48:2002;131-139.
    • (2002) Clin Chem , vol.48 , pp. 131-139
    • Rozaklis, T.1    Ramsay, S.L.2    Whitfield, P.D.3    Ranieri, E.4    Hopwood, J.J.5    Meikle, P.J.6
  • 45
    • 0035984619 scopus 로고    scopus 로고
    • Rapid quantitation of globotriaosylceramide in human plasma and urine: A potential application for monitoring enzyme replacement therapy in Anderson-Fabry disease
    • Boscaro F., Pieraccini G., la Marca G., Bartolucci G., Luceri C., Luceri F., Moneti G. Rapid quantitation of globotriaosylceramide in human plasma and urine a potential application for monitoring enzyme replacement therapy in Anderson-Fabry disease . Rapid Commun Mass Spectrom. 16:2002;1507-1514.
    • (2002) Rapid Commun Mass Spectrom , vol.16 , pp. 1507-1514
    • Boscaro, F.1    Pieraccini, G.2    La Marca, G.3    Bartolucci, G.4    Luceri, C.5    Luceri, F.6    Moneti, G.7
  • 46
    • 0035717736 scopus 로고    scopus 로고
    • Characterization of urinary sulfatides in metachromatic leukodystrophy using electrospray ionization-tandem mass spectrometry
    • Whitfield P.D., Sharp P.C., Johnson D.W., Nelson P., Meikle P.J. Characterization of urinary sulfatides in metachromatic leukodystrophy using electrospray ionization-tandem mass spectrometry. Mol Genet Metab. 73:2001;30-37.
    • (2001) Mol Genet Metab , vol.73 , pp. 30-37
    • Whitfield, P.D.1    Sharp, P.C.2    Johnson, D.W.3    Nelson, P.4    Meikle, P.J.5
  • 47
    • 0033026373 scopus 로고    scopus 로고
    • The identification of unusual bile acid metabolites by tandem mass spectrometry: Use of low-energy collision-induced dissociation to produce informative spectra
    • Lemonde H.A., Johnson A.W., Clayton P.T. The identification of unusual bile acid metabolites by tandem mass spectrometry use of low-energy collision-induced dissociation to produce informative spectra . Rapid Commun Mass Spectrom. 13:1999;1159-1164.
    • (1999) Rapid Commun Mass Spectrom , vol.13 , pp. 1159-1164
    • Lemonde, H.A.1    Johnson, A.W.2    Clayton, P.T.3
  • 48
    • 0035130720 scopus 로고    scopus 로고
    • Rapid and quantitative analysis of unconjugated C(27) bile acids in plasma and blood samples by tandem mass spectrometry
    • Johnson D.W., ten Brink H.J., Schuit R.C., Jakobs C. Rapid and quantitative analysis of unconjugated C(27) bile acids in plasma and blood samples by tandem mass spectrometry. J Lipid Res. 42:2001;9-16.
    • (2001) J Lipid Res , vol.42 , pp. 9-16
    • Johnson, D.W.1    Ten Brink, H.J.2    Schuit, R.C.3    Jakobs, C.4
  • 49
    • 0034075405 scopus 로고    scopus 로고
    • Rapid screening of high-risk patients for disorders of purine and pyrimidine metabolism using HPLC-electrospray tandem mass spectrometry of liquid urine or urine-soaked filter paper strips
    • Ito T., van Kuilenburg A.B., Bootsma A.H., Haasnoot A.J., van Cruchten A., Wada Y., van Gennip A.H. Rapid screening of high-risk patients for disorders of purine and pyrimidine metabolism using HPLC-electrospray tandem mass spectrometry of liquid urine or urine-soaked filter paper strips. Clin Chem. 46:2000;445-452.
    • (2000) Clin Chem , vol.46 , pp. 445-452
    • Ito, T.1    Van Kuilenburg, A.B.2    Bootsma, A.H.3    Haasnoot, A.J.4    Van Cruchten, A.5    Wada, Y.6    Van Gennip, A.H.7
  • 50
    • 0034753097 scopus 로고    scopus 로고
    • A rapid screening procedure for cholesterol and dehydrocholesterol by electrospray ionization tandem mass spectrometry
    • Johnson D.W., ten Brink H.J., Jakobs C. A rapid screening procedure for cholesterol and dehydrocholesterol by electrospray ionization tandem mass spectrometry. J Lipid Res. 42:2001;1699-1705.
    • (2001) J Lipid Res , vol.42 , pp. 1699-1705
    • Johnson, D.W.1    Ten Brink, H.J.2    Jakobs, C.3
  • 51
    • 0033756351 scopus 로고    scopus 로고
    • Methylmalonic acid measured in plasma and urine by stable-isotope dilution and electrospray tandem mass spectrometry
    • Magera M.J., Helgeson J.K., Matern D., Rinaldo P. Methylmalonic acid measured in plasma and urine by stable-isotope dilution and electrospray tandem mass spectrometry. Clin Chem. 46:2000;1804-1810.
    • (2000) Clin Chem , vol.46 , pp. 1804-1810
    • Magera, M.J.1    Helgeson, J.K.2    Matern, D.3    Rinaldo, P.4
  • 52
    • 0034781986 scopus 로고    scopus 로고
    • Analysis of dicarboxylic acids by tandem mass spectrometry. High- throughput quantitative measurement of methylmalonic acid in serum, plasma, and urine
    • Kushnir M.M., Komaromy-Hiller G., Shushan B., Urry F.M., Roberts W.L. Analysis of dicarboxylic acids by tandem mass spectrometry. High- throughput quantitative measurement of methylmalonic acid in serum, plasma, and urine. Clin Chem. 47:2001;1993-2002.
    • (2001) Clin Chem , vol.47 , pp. 1993-2002
    • Kushnir, M.M.1    Komaromy-Hiller, G.2    Shushan, B.3    Urry, F.M.4    Roberts, W.L.5
  • 53
    • 0035197509 scopus 로고    scopus 로고
    • Determination of L-pipecolic acid in plasma using chiral liquid chromatography-electrospray tandem mass spectrometry
    • Rashed M.S., Al-Ahaidib L.Y., Aboul-Enein H.Y., Al-Amoudi M., Jacob M. Determination of L-pipecolic acid in plasma using chiral liquid chromatography-electrospray tandem mass spectrometry. Clin Chem. 47:2001;2124-2130.
    • (2001) Clin Chem , vol.47 , pp. 2124-2130
    • Rashed, M.S.1    Al-Ahaidib, L.Y.2    Aboul-Enein, H.Y.3    Al-Amoudi, M.4    Jacob, M.5
  • 54
    • 0034866653 scopus 로고    scopus 로고
    • Quantitative measurement of porphobilinogen in urine by stable-isotope dilution liquid chromatography-tandem mass spectrometry
    • Ford R.E., Magera M.J., Kloke K.M., Chezick P.A., Fauq A., McConnell J.P. Quantitative measurement of porphobilinogen in urine by stable-isotope dilution liquid chromatography-tandem mass spectrometry. Clin Chem. 47:2001;1627-1632.
    • (2001) Clin Chem , vol.47 , pp. 1627-1632
    • Ford, R.E.1    Magera, M.J.2    Kloke, K.M.3    Chezick, P.A.4    Fauq, A.5    McConnell, J.P.6
  • 55
    • 0030063763 scopus 로고    scopus 로고
    • Sensitive, specific quantitative analysis of tacrolimus (FK506) in blood by liquid chromatography-electrospray tandem mass spectrometry
    • Taylor P.J., Jones A., Balderson G.A., Lynch S.V., Norris R.L., Pond S.M. Sensitive, specific quantitative analysis of tacrolimus (FK506) in blood by liquid chromatography-electrospray tandem mass spectrometry. Clin Chem. 42:1996;279-285.
    • (1996) Clin Chem , vol.42 , pp. 279-285
    • Taylor, P.J.1    Jones, A.2    Balderson, G.A.3    Lynch, S.V.4    Norris, R.L.5    Pond, S.M.6
  • 56
    • 0036140448 scopus 로고    scopus 로고
    • Rapid liquid chromatography-tandem mass spectrometry method for routine analysis of cyclosporin A over an extended concentration range
    • Keevil B.G., Tierney D.P., Cooper D.P., Morris M.R. Rapid liquid chromatography-tandem mass spectrometry method for routine analysis of cyclosporin A over an extended concentration range. Clin Chem. 48:2002;69-76.
    • (2002) Clin Chem , vol.48 , pp. 69-76
    • Keevil, B.G.1    Tierney, D.P.2    Cooper, D.P.3    Morris, M.R.4
  • 57
    • 0036188717 scopus 로고    scopus 로고
    • Quantification of sirolimus by liquid chromatography-tandem mass spectrometry using on-line solid-phase extraction
    • Vogeser M., Fleischer C., Meiser B., Groetzner J., Spohrer U., Seidel D. Quantification of sirolimus by liquid chromatography-tandem mass spectrometry using on-line solid-phase extraction. Clin Chem Lab Med. 40:2002;40-45.
    • (2002) Clin Chem Lab Med , vol.40 , pp. 40-45
    • Vogeser, M.1    Fleischer, C.2    Meiser, B.3    Groetzner, J.4    Spohrer, U.5    Seidel, D.6
  • 58
    • 0036267333 scopus 로고    scopus 로고
    • Rapid liquid chromatography-tandem mass spectrometry routine method for simultaneous determination of sirolimus, everolimus, tacrolimus, and cyclosporin A in whole blood
    • Streit F., Armstrong V.W., Oellerich M. Rapid liquid chromatography-tandem mass spectrometry routine method for simultaneous determination of sirolimus, everolimus, tacrolimus, and cyclosporin A in whole blood. Clin Chem. 48:2002;955-958.
    • (2002) Clin Chem , vol.48 , pp. 955-958
    • Streit, F.1    Armstrong, V.W.2    Oellerich, M.3
  • 59
    • 0034968962 scopus 로고    scopus 로고
    • Simultaneous simple and fast quantification of three major immunosuppressants by liquid chromatography-tandem mass-spectrometry
    • Volosov A., Napoli K.L., Soldin S.J. Simultaneous simple and fast quantification of three major immunosuppressants by liquid chromatography-tandem mass-spectrometry. Clin Biochem. 34:2001;285-290.
    • (2001) Clin Biochem , vol.34 , pp. 285-290
    • Volosov, A.1    Napoli, K.L.2    Soldin, S.J.3
  • 60
    • 0036337450 scopus 로고    scopus 로고
    • Simultaneous determination of seven tricyclic antidepressant drugs in human plasma by direct-injection HPLC-APCI-MS-MS with an ion trap detector
    • Kollroser M., Schober C. Simultaneous determination of seven tricyclic antidepressant drugs in human plasma by direct-injection HPLC-APCI-MS-MS with an ion trap detector. Ther Drug Monit. 24:2002;537-544.
    • (2002) Ther Drug Monit , vol.24 , pp. 537-544
    • Kollroser, M.1    Schober, C.2
  • 61
    • 0036140427 scopus 로고    scopus 로고
    • Determination of coumarin-type anticoagulants in human plasma by HPLC- electrospray ionization tandem mass spectrometry with an ion trap detector
    • Kollroser M., Schober C. Determination of coumarin-type anticoagulants in human plasma by HPLC- electrospray ionization tandem mass spectrometry with an ion trap detector. Clin Chem. 48:2002;84-91.
    • (2002) Clin Chem , vol.48 , pp. 84-91
    • Kollroser, M.1    Schober, C.2
  • 62
    • 0032884065 scopus 로고    scopus 로고
    • Broad spectrum drug identification directly from urine, using liquid chromatography-tandem mass spectrometry
    • Fitzgerald R.L., Rivera J.D., Herold D.A. Broad spectrum drug identification directly from urine, using liquid chromatography-tandem mass spectrometry. Clin Chem. 45:1999;1224-1234.
    • (1999) Clin Chem , vol.45 , pp. 1224-1234
    • Fitzgerald, R.L.1    Rivera, J.D.2    Herold, D.A.3
  • 63
    • 0031829181 scopus 로고    scopus 로고
    • Fast screening for drugs of abuse by solid-phase extraction combined with flow-injection ionspray-tandem mass spectrometry
    • Weinmann W., Svoboda M. Fast screening for drugs of abuse by solid-phase extraction combined with flow-injection ionspray-tandem mass spectrometry. J Anal Toxicol. 22:1998;319-328.
    • (1998) J Anal Toxicol , vol.22 , pp. 319-328
    • Weinmann, W.1    Svoboda, M.2
  • 64
    • 0033637280 scopus 로고    scopus 로고
    • Determination of the designer drugs 3, 4-methylenedioxymethamphetamine, 3,4-methylenedioxyethylamphetamine, and 3,4-methylenedioxyamphetamine with HPLC and fluorescence detection in whole blood, serum, vitreous humor, and urine
    • Clauwaert K.M., Van Bocxlaer J.F., De Letter E.A., Van Calenbergh S., Lambert W.E., De Leenheer A.P. Determination of the designer drugs 3, 4-methylenedioxymethamphetamine, 3,4-methylenedioxyethylamphetamine, and 3,4-methylenedioxyamphetamine with HPLC and fluorescence detection in whole blood, serum, vitreous humor, and urine. Clin Chem. 46:2000;1968-1977.
    • (2000) Clin Chem , vol.46 , pp. 1968-1977
    • Clauwaert, K.M.1    Van Bocxlaer, J.F.2    De Letter, E.A.3    Van Calenbergh, S.4    Lambert, W.E.5    De Leenheer, A.P.6
  • 65
    • 0036007254 scopus 로고    scopus 로고
    • Stability of 11-nor-delta(9)-carboxy-tetrahydrocannabinol glucuronide in plasma and urine assessed by liquid chromatography-tandem mass spectrometry
    • Skopp G., Potsch L. Stability of 11-nor-delta(9)-carboxy-tetrahydrocannabinol glucuronide in plasma and urine assessed by liquid chromatography-tandem mass spectrometry. Clin Chem. 48:2002;301-306.
    • (2002) Clin Chem , vol.48 , pp. 301-306
    • Skopp, G.1    Potsch, L.2
  • 66
    • 0024094503 scopus 로고
    • Tandem mass spectrometry in drug-abuse testing, exemplified for anabolic steroids
    • Kinter M., Shipe J.R., Savory J. Tandem mass spectrometry in drug-abuse testing, exemplified for anabolic steroids. Clin Chem. 34:1988;2178.
    • (1988) Clin Chem , vol.34 , pp. 2178
    • Kinter, M.1    Shipe, J.R.2    Savory, J.3
  • 67
    • 0025125769 scopus 로고
    • High-performance liquid chromatography/tandem mass spectrometry: Its use for the identification of stanozolol and its major metabolites in human and equine urine
    • Muck W.M., Henion J.D. High-performance liquid chromatography/tandem mass spectrometry its use for the identification of stanozolol and its major metabolites in human and equine urine . Biomed Environ Mass Spectrom. 19:1990;37-51.
    • (1990) Biomed Environ Mass Spectrom , vol.19 , pp. 37-51
    • Muck, W.M.1    Henion, J.D.2
  • 68
    • 0030573002 scopus 로고    scopus 로고
    • Separation and confirmation of anabolic steroids with quadrupole ion trap tandem mass spectrometry
    • Bowers L.D., Borts D.J. Separation and confirmation of anabolic steroids with quadrupole ion trap tandem mass spectrometry. J Chromatogr B Biomed Appl. 687:1996;69-78.
    • (1996) J Chromatogr B Biomed Appl , vol.687 , pp. 69-78
    • Bowers, L.D.1    Borts, D.J.2
  • 69
    • 0030949397 scopus 로고    scopus 로고
    • Direct determination of anabolic steroid conjugates in human urine by combined high-performance liquid chromatography and tandem mass spectrometry
    • Bean K.A., Henion J.D. Direct determination of anabolic steroid conjugates in human urine by combined high-performance liquid chromatography and tandem mass spectrometry. J Chromatogr B Biomed Sci Appl. 690:1997;65-75.
    • (1997) J Chromatogr B Biomed Sci Appl , vol.690 , pp. 65-75
    • Bean, K.A.1    Henion, J.D.2
  • 70
    • 0036312640 scopus 로고    scopus 로고
    • Liquid chromatography/mass spectrometry in anabolic steroid analysis-optimization and comparison of three ionization techniques: Electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization
    • Leinonen A., Kuuranne T., Kostiainen R. Liquid chromatography/mass spectrometry in anabolic steroid analysis-optimization and comparison of three ionization techniques electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization . J Mass Spectrom. 37:2002;693-698.
    • (2002) J Mass Spectrom , vol.37 , pp. 693-698
    • Leinonen, A.1    Kuuranne, T.2    Kostiainen, R.3
  • 71
    • 0036132137 scopus 로고    scopus 로고
    • Plasma and urinary markers of oral testosterone undecanoate misuse
    • Peng S.H., Segura J., Farre M., Gonzalez J.C., de la Torre X. Plasma and urinary markers of oral testosterone undecanoate misuse. Steroids. 67:2002;39-50.
    • (2002) Steroids , vol.67 , pp. 39-50
    • Peng, S.H.1    Segura, J.2    Farre, M.3    Gonzalez, J.C.4    De La Torre, X.5
  • 72
    • 0033954264 scopus 로고    scopus 로고
    • Direct measurement of urinary testosterone and epitestosterone conjugates using high-performance liquid chromatography/tandem mass spectrometry
    • Borts D.J., Bowers L.D. Direct measurement of urinary testosterone and epitestosterone conjugates using high-performance liquid chromatography/tandem mass spectrometry. J Mass Spectrom. 35:2000;50-61.
    • (2000) J Mass Spectrom , vol.35 , pp. 50-61
    • Borts, D.J.1    Bowers, L.D.2
  • 73
    • 0036720952 scopus 로고    scopus 로고
    • Simultaneous analysis of nicotine, nicotine metabolites, and tobacco alkaloids in serum or urine by tandem mass spectrometry, with clinically relevant metabolic profiles
    • Moyer T.P., Charlson J.R., Enger R.J., Dale L.C., Ebbert J.O., Schroeder D.R., Hurt R.D. Simultaneous analysis of nicotine, nicotine metabolites, and tobacco alkaloids in serum or urine by tandem mass spectrometry, with clinically relevant metabolic profiles. Clin Chem. 48:2002;1460-1471.
    • (2002) Clin Chem , vol.48 , pp. 1460-1471
    • Moyer, T.P.1    Charlson, J.R.2    Enger, R.J.3    Dale, L.C.4    Ebbert, J.O.5    Schroeder, D.R.6    Hurt, R.D.7
  • 75
    • 0032758676 scopus 로고    scopus 로고
    • Analysis of nicotine, 3-hydroxycotinine, cotinine, and caffeine in urine of passive smokers by HPLC-tandem mass spectrometry
    • Tuomi T., Johnsson T., Reijula K. Analysis of nicotine, 3-hydroxycotinine, cotinine, and caffeine in urine of passive smokers by HPLC-tandem mass spectrometry. Clin Chem. 45:1999;2164-2172.
    • (1999) Clin Chem , vol.45 , pp. 2164-2172
    • Tuomi, T.1    Johnsson, T.2    Reijula, K.3
  • 76
    • 0035051242 scopus 로고    scopus 로고
    • Diagnosis of adrenal cortical dysfunction by liquid chromatography-tandem mass spectrometry
    • Kao P.C., Machacek D.A., Magera M.J., Lacey J.M., Rinaldo P. Diagnosis of adrenal cortical dysfunction by liquid chromatography-tandem mass spectrometry. Ann Clin Lab Sci. 31:2001;199-204.
    • (2001) Ann Clin Lab Sci , vol.31 , pp. 199-204
    • Kao, P.C.1    Machacek, D.A.2    Magera, M.J.3    Lacey, J.M.4    Rinaldo, P.5
  • 77
    • 0033818514 scopus 로고    scopus 로고
    • Determination of 17-hydroxyprogesterone in plasma by stable isotope dilution/benchtop liquid chromatography-tandem mass spectrometry
    • Wudy S.A., Hartmann M., Svoboda M. Determination of 17-hydroxyprogesterone in plasma by stable isotope dilution/benchtop liquid chromatography-tandem mass spectrometry. Horm Res. 53:2000;68-71.
    • (2000) Horm Res , vol.53 , pp. 68-71
    • Wudy, S.A.1    Hartmann, M.2    Svoboda, M.3
  • 78
    • 0036386966 scopus 로고    scopus 로고
    • Increased ratio of serum cortisol to cortisone in acute-phase response
    • Vogeser M., Zachoval R., Felbinger T.W., Jacob K. Increased ratio of serum cortisol to cortisone in acute-phase response. Horm Res. 58:2002;172-175.
    • (2002) Horm Res , vol.58 , pp. 172-175
    • Vogeser, M.1    Zachoval, R.2    Felbinger, T.W.3    Jacob, K.4
  • 79
    • 0036721539 scopus 로고    scopus 로고
    • Validation of a high-throughput liquid chromatography-tandem mass spectrometry method for urinary cortisol and cortisone
    • Taylor R.L., Machacek D., Singh R.J. Validation of a high-throughput liquid chromatography-tandem mass spectrometry method for urinary cortisol and cortisone. Clin Chem. 48:2002;1511-1519.
    • (2002) Clin Chem , vol.48 , pp. 1511-1519
    • Taylor, R.L.1    Machacek, D.2    Singh, R.J.3
  • 80
    • 0032895684 scopus 로고    scopus 로고
    • Measurement of plasma renin activity with use of HPLC-electrospray-tandem mass spectrometry
    • Fredline V.F., Kovacs E.M., Taylor P.J., Johnson A.G. Measurement of plasma renin activity with use of HPLC-electrospray-tandem mass spectrometry. Clin Chem. 45:1999;659-664.
    • (1999) Clin Chem , vol.45 , pp. 659-664
    • Fredline, V.F.1    Kovacs, E.M.2    Taylor, P.J.3    Johnson, A.G.4
  • 81
    • 0030853916 scopus 로고    scopus 로고
    • Analysis of bile acids and bile alcohols in urine by capillary column liquid chromatography-mass spectrometry using fast atom bombardment or electrospray ionization and collision-induced dissociation
    • Yang Y., Griffiths W.J., Nazer H., Sjovall J. Analysis of bile acids and bile alcohols in urine by capillary column liquid chromatography-mass spectrometry using fast atom bombardment or electrospray ionization and collision-induced dissociation. Biomed Chromatogr. 11:1997;240-255.
    • (1997) Biomed Chromatogr , vol.11 , pp. 240-255
    • Yang, Y.1    Griffiths, W.J.2    Nazer, H.3    Sjovall, J.4
  • 82
    • 0035130714 scopus 로고    scopus 로고
    • Determination of bile acids in biological fluids by liquid chromatography-electrospray tandem mass spectrometry
    • Perwaiz S., Tuchweber B., Mignault D., Gilat T., Yousef I.M. Determination of bile acids in biological fluids by liquid chromatography-electrospray tandem mass spectrometry. J Lipid Res. 42:2001;114-119.
    • (2001) J Lipid Res , vol.42 , pp. 114-119
    • Perwaiz, S.1    Tuchweber, B.2    Mignault, D.3    Gilat, T.4    Yousef, I.M.5
  • 83
    • 0031888585 scopus 로고    scopus 로고
    • A method for the quantitation of conjugated bile acids in dried blood spots using electrospray ionization-mass spectrometry
    • Mills K.A., Mushtaq I., Johnson A.W., Whitfield P.D., Clayton P.T. A method for the quantitation of conjugated bile acids in dried blood spots using electrospray ionization-mass spectrometry. Pediatr Res. 43:1998;361-368.
    • (1998) Pediatr Res , vol.43 , pp. 361-368
    • Mills, K.A.1    Mushtaq, I.2    Johnson, A.W.3    Whitfield, P.D.4    Clayton, P.T.5
  • 84
    • 0032823860 scopus 로고    scopus 로고
    • Method for the determination of total homocysteine in plasma and urine by stable isotope dilution and electrospray tandem mass spectrometry
    • Magera M.J., Lacey J.M., Casetta B., Rinaldo P. Method for the determination of total homocysteine in plasma and urine by stable isotope dilution and electrospray tandem mass spectrometry. Clin Chem. 45:1999;1517-1522.
    • (1999) Clin Chem , vol.45 , pp. 1517-1522
    • Magera, M.J.1    Lacey, J.M.2    Casetta, B.3    Rinaldo, P.4
  • 85
    • 0036153476 scopus 로고    scopus 로고
    • Analysis of catecholamines in urine by positive-ion electrospray tandem mass spectrometry
    • Kushnir M.M., Urry F.M., Frank E.L., Roberts W.L., Shushan B. Analysis of catecholamines in urine by positive-ion electrospray tandem mass spectrometry. Clin Chem. 48:2002;323-331.
    • (2002) Clin Chem , vol.48 , pp. 323-331
    • Kushnir, M.M.1    Urry, F.M.2    Frank, E.L.3    Roberts, W.L.4    Shushan, B.5
  • 86
    • 0037026431 scopus 로고    scopus 로고
    • Determination of catecholamines and metanephrines in urine by capillary electrophoresis-electrospray ionization-time-of-flight mass spectrometry
    • Peterson Z.D., Collins D.C., Bowerbank C.R., Lee M.L., Graves S.W. Determination of catecholamines and metanephrines in urine by capillary electrophoresis-electrospray ionization-time-of-flight mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci. 776:2002;221-229.
    • (2002) J Chromatogr B Analyt Technol Biomed Life Sci , vol.776 , pp. 221-229
    • Peterson, Z.D.1    Collins, D.C.2    Bowerbank, C.R.3    Lee, M.L.4    Graves, S.W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.