메뉴 건너뛰기




Volumn 2, Issue 4-5, 2002, Pages 138-153

Proteomics without polyacrylamide: Qualitative and quantitative uses of tandem mass spectrometry in proteome analysis

Author keywords

Multi dimensional chromatography; Proteomics; Quantification; Tandem mass spectrometry

Indexed keywords

MESSENGER RNA; POLYACRYLAMIDE; PROTEOME;

EID: 0036731271     PISSN: 1438793X     EISSN: 14387948     Source Type: Journal    
DOI: 10.1007/s10142-001-0041-3     Document Type: Review
Times cited : (33)

References (98)
  • 1
    • 0035241690 scopus 로고    scopus 로고
    • Mass spectrometry in proteomics
    • Aebersold R, Goodlett DR (2001) Mass spectrometry in proteomics. Chem Rev 101:69-95
    • (2001) Chem Rev , vol.101 , pp. 69-95
    • Aebersold, R.1    Goodlett, D.R.2
  • 4
    • 0034657819 scopus 로고    scopus 로고
    • Zeptomole-sensitivity electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry of proteins
    • Belov ME, Gorshkov MV, Udseth HR, Anderson GA, Smith RD (2000) Zeptomole-sensitivity electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry of proteins. Anal Chem 72:2271-2279
    • (2000) Anal Chem , vol.72 , pp. 2271-2279
    • Belov, M.E.1    Gorshkov, M.V.2    Udseth, H.R.3    Anderson, G.A.4    Smith, R.D.5
  • 5
    • 0025617140 scopus 로고
    • Nomenclature for peptide fragment ions (positive ions)
    • Biemann K (1990) Nomenclature for peptide fragment ions (positive ions). Methods Enzymol 193:886-887
    • (1990) Methods Enzymol , vol.193 , pp. 886-887
    • Biemann, K.1
  • 7
    • 0029108047 scopus 로고
    • Recovery of peptides and proteins following matrix-assisted laser desorption ionization mass spectrometry
    • Cerpa-Poljak A, Jenkins A, Duncan MW (1995) Recovery of peptides and proteins following matrix-assisted laser desorption ionization mass spectrometry. Rapid Commun Mass Spectrom 9:233
    • (1995) Rapid Commun Mass Spectrom , vol.9 , pp. 233
    • Cerpa-Poljak, A.1    Jenkins, A.2    Duncan, M.W.3
  • 8
    • 0026706930 scopus 로고
    • Weighing naked proteins: Practical, high-accuracy mass measurement of peptides and proteins
    • Chait BT, Kent SB (1992) Weighing naked proteins: practical, high-accuracy mass measurement of peptides and proteins. Science 257:1885-1894
    • (1992) Science , vol.257 , pp. 1885-1894
    • Chait, B.T.1    Kent, S.B.2
  • 9
    • 0033374004 scopus 로고    scopus 로고
    • Peptide and protein identification by matrix-assisted laser desorption ionization (MALDI) and MALDI-post-source decay time-of-flight mass spectrometry
    • Chaurand P, Luetzenkirchen F, Spengler B (1999) Peptide and protein identification by matrix-assisted laser desorption ionization (MALDI) and MALDI-post-source decay time-of-flight mass spectrometry. J Am Soc Mass Spectrom 10:91-103
    • (1999) J Am Soc Mass Spectrom , vol.10 , pp. 91-103
    • Chaurand, P.1    Luetzenkirchen, F.2    Spengler, B.3
  • 12
    • 0027937460 scopus 로고
    • Determination of nanogram levels of peptide drug in rabbit and human plasma using high-performance liquid chromatography coupled with electrospray ionization mass spectrometry
    • Crowther J, Adusumalli V, Mukherjee T, Jordan K, Abuaf P, Corkum N, Goldstein G, Tolan J (1994) Determination of nanogram levels of peptide drug in rabbit and human plasma using high-performance liquid chromatography coupled with electrospray ionization mass spectrometry. Anal Chem 66:2356-2361
    • (1994) Anal Chem , vol.66 , pp. 2356-2361
    • Crowther, J.1    Adusumalli, V.2    Mukherjee, T.3    Jordan, K.4    Abuaf, P.5    Corkum, N.6    Goldstein, G.7    Tolan, J.8
  • 14
    • 0032009398 scopus 로고    scopus 로고
    • Rapid protein identification using a microscale electrospray LC/MS system on an ion trap mass spectrometer
    • Davis MT, Lee TD (1998) Rapid protein identification using a microscale electrospray LC/MS system on an ion trap mass spectrometer. J Am Soc Mass Spectrom 9:194-201
    • (1998) J Am Soc Mass Spectrom , vol.9 , pp. 194-201
    • Davis, M.T.1    Lee, T.D.2
  • 16
    • 0000568858 scopus 로고
    • Applications of isotope dilution mass spectrometry in clinical chemistry, pharmacokinetics and toxicology
    • DeLeenheer AP, Thienpont LM (1992) Applications of isotope dilution mass spectrometry in clinical chemistry, pharmacokinetics and toxicology. Mass Spectrom Rev 11:249
    • (1992) Mass Spectrom Rev , vol.11 , pp. 249
    • DeLeenheer, A.P.1    Thienpont, L.M.2
  • 17
    • 0030669030 scopus 로고    scopus 로고
    • Exploring the metabolic and genetic control of gene expression on a genomic scale
    • DeRisis L, Iyer VR, Brown PO (1997) Exploring the metabolic and genetic control of gene expression on a genomic scale. Science 278:680-686
    • (1997) Science , vol.278 , pp. 680-686
    • DeRisis, L.1    Iyer, V.R.2    Brown, P.O.3
  • 18
    • 0031888036 scopus 로고    scopus 로고
    • High throughput protein characterization by automated reverse-phase chromatography/electrospray tandem mass spectrometry
    • Ducret A, van Oostveen I, Eng JK, Yates JR III, Aebersold R (1998) High throughput protein characterization by automated reverse-phase chromatography/electrospray tandem mass spectrometry. Protein Sci 7:706-719
    • (1998) Protein Sci , vol.7 , pp. 706-719
    • Ducret, A.1    Van Oostveen, I.2    Eng, J.K.3    Yates III, J.R.4    Aebersold, R.5
  • 19
    • 0000178042 scopus 로고
    • Micro-electrospray. MS: Ultra-high-sensitivity analysis of peptides and proteins
    • Emmett MR, Caprioli RM (1994) Micro-electrospray. MS: ultra-high-sensitivity analysis of peptides and proteins. J Am Soc Mass Spectrom 5:605-613
    • (1994) J Am Soc Mass Spectrom , vol.5 , pp. 605-613
    • Emmett, M.R.1    Caprioli, R.M.2
  • 20
    • 0000857494 scopus 로고
    • An approach to correlate tandem mass spectral data of peptides with amino acid sequences in a protein database
    • Eng JK, McCormack AL, Yates JR III (1994) An approach to correlate tandem mass spectral data of peptides with amino acid sequences in a protein database. J Am Soc Mass Spectrom 5:976-989
    • (1994) J Am Soc Mass Spectrom , vol.5 , pp. 976-989
    • Eng, J.K.1    McCormack, A.L.2    Yates III, J.R.3
  • 21
    • 0024438708 scopus 로고
    • Electrospray ionization for mass spectrometry of large biomolecules
    • Fenn JB, Mann M, Meng CK, Wong SF, Whitehouse CM (1989) Electrospray ionization for mass spectrometry of large biomolecules. Science 246:64-71
    • (1989) Science , vol.246 , pp. 64-71
    • Fenn, J.B.1    Mann, M.2    Meng, C.K.3    Wong, S.F.4    Whitehouse, C.M.5
  • 23
    • 0035823097 scopus 로고    scopus 로고
    • Integrated studies on plant biology using multiparallel techniques
    • Fiehn O, Kloska S, Altmann T (2000) Integrated studies on plant biology using multiparallel techniques. Curr Opin Biotechnol 12:82-86
    • (2000) Curr Opin Biotechnol , vol.12 , pp. 82-86
    • Fiehn, O.1    Kloska, S.2    Altmann, T.3
  • 24
    • 0031814440 scopus 로고    scopus 로고
    • High sensitivity analysis of proteins and peptides by capillary electrophoresis-tandem mass spectrometry: Recent developments in technology and applications
    • Figeys D, Aebersold R (1998) High sensitivity analysis of proteins and peptides by capillary electrophoresis-tandem mass spectrometry: recent developments in technology and applications. Electrophoresis 19:885-892
    • (1998) Electrophoresis , vol.19 , pp. 885-892
    • Figeys, D.1    Aebersold, R.2
  • 25
    • 0032530015 scopus 로고    scopus 로고
    • An integrated microfluidics-tandem mass spectrometry system for automated protein analysis
    • Figeys D, Gygi SP, McKinnon G, Aebersold R (1998) An integrated microfluidics-tandem mass spectrometry system for automated protein analysis. Anal Chem 70:3728-3734
    • (1998) Anal Chem , vol.70 , pp. 3728-3734
    • Figeys, D.1    Gygi, S.P.2    McKinnon, G.3    Aebersold, R.4
  • 26
    • 0033168694 scopus 로고    scopus 로고
    • Data-dependent modulation of solid-phase extraction capillary electrophoresis for the analysis of complex peptide and phosphopeptide mixtures by tandem mass spectrometry: Application to endothelial nitric oxide synthase
    • Figeys D, Corthals GL, Gallis B, Goodlett DR, Ducret A, Corson MA, Aebersold R (1999) Data-dependent modulation of solid-phase extraction capillary electrophoresis for the analysis of complex peptide and phosphopeptide mixtures by tandem mass spectrometry: application to endothelial nitric oxide synthase. Anal Chem 71:2279-2287
    • (1999) Anal Chem , vol.71 , pp. 2279-2287
    • Figeys, D.1    Corthals, G.L.2    Gallis, B.3    Goodlett, D.R.4    Ducret, A.5    Corson, M.A.6    Aebersold, R.7
  • 27
    • 0032767911 scopus 로고    scopus 로고
    • Cell cycle synchronization
    • Futcher B (1999) Cell cycle synchronization. Methods Cell Sci 21:79-86
    • (1999) Methods Cell Sci , vol.21 , pp. 79-86
    • Futcher, B.1
  • 29
    • 84986749851 scopus 로고
    • Reduced elution speed detection for capillary electrophoresis-mass spectrometry
    • Goodlett DR, Wahl JH, Udseth HR, Smith RD (1993b) Reduced elution speed detection for capillary electrophoresis-mass spectrometry. J Microcolumn Separat 5:57
    • (1993) J Microcolumn Separat , vol.5 , pp. 57
    • Goodlett, D.R.1    Wahl, J.H.2    Udseth, H.R.3    Smith, R.D.4
  • 31
  • 34
    • 0033016717 scopus 로고    scopus 로고
    • Correlation between protein and mRNA abundance in yeast
    • Gygi SP, Rochon Y, Franza B, Aebersold R (1999a) Correlation between protein and mRNA abundance in yeast. Mol Cell Biol 19:1720-1730
    • (1999) Mol Cell Biol , vol.19 , pp. 1720-1730
    • Gygi, S.P.1    Rochon, Y.2    Franza, B.3    Aebersold, R.4
  • 35
    • 0032875697 scopus 로고    scopus 로고
    • Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
    • Gygi SP, Rist B, Gerber SA, Turecek F, Gelb MH, Aebersold R (1999b) Quantitative analysis of complex protein mixtures using isotope-coded affinity tags. Nat Biotech 17:994-999
    • (1999) Nat Biotech , vol.17 , pp. 994-999
    • Gygi, S.P.1    Rist, B.2    Gerber, S.A.3    Turecek, F.4    Gelb, M.H.5    Aebersold, R.6
  • 36
    • 0034789979 scopus 로고    scopus 로고
    • Quantitative profiling of differentiation-induced microsomal proteins using isotope-coded affinity tags and mass spectrometry
    • Han DK, Eng J, Zhou H, Aebersold R (2001) Quantitative profiling of differentiation-induced microsomal proteins using isotope-coded affinity tags and mass spectrometry. Nat Biotech 19:946-951
    • (2001) Nat Biotech , vol.19 , pp. 946-951
    • Han, D.K.1    Eng, J.2    Zhou, H.3    Aebersold, R.4
  • 39
  • 41
    • 0030078307 scopus 로고    scopus 로고
    • Automated analytical system for the examination of protein primary structure
    • Hsieh YL, Wang H, Elicone C, Mark J, Martin SA, Regnier F (1996) Automated analytical system for the examination of protein primary structure. Anal Chem 68:455-462
    • (1996) Anal Chem , vol.68 , pp. 455-462
    • Hsieh, Y.L.1    Wang, H.2    Elicone, C.3    Mark, J.4    Martin, S.A.5    Regnier, F.6
  • 44
    • 0025652826 scopus 로고
    • Molecular weight analysis of proteins
    • Jardine I (1990) Molecular weight analysis of proteins. Methods Enzymol 193:441-455
    • (1990) Methods Enzymol , vol.193 , pp. 441-455
    • Jardine, I.1
  • 46
    • 0024289037 scopus 로고
    • Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
    • Karas M, Hillenkamp F (1995) Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons. Anal Chem 60:2299-2301
    • (1995) Anal Chem , vol.60 , pp. 2299-2301
    • Karas, M.1    Hillenkamp, F.2
  • 48
    • 0029746504 scopus 로고    scopus 로고
    • Post-source decay and delayed extraction in matrix-assisted laser desorption/ionization-reflectron time-of-flight mass spectrometry. Are there trade-offs?
    • Kaufmann R, Chaurand P, Kirsch D, Spengler B (1996) Post-source decay and delayed extraction in matrix-assisted laser desorption/ionization-reflectron time-of-flight mass spectrometry. Are there trade-offs? Rapid Commun Mass Spectrom 10:1199-208
    • (1996) Rapid Commun Mass Spectrom , vol.10 , pp. 1199-1208
    • Kaufmann, R.1    Chaurand, P.2    Kirsch, D.3    Spengler, B.4
  • 49
    • 4243802293 scopus 로고
    • Preparation and evaluation of packed capillary liquid chromatography columns with inner diameter from 20 to 50 μ
    • Kennedy R, Jorgenson JW (1991) Preparation and evaluation of packed capillary liquid chromatography columns with inner diameter from 20 to 50 μ. Anal Chem 63:1467
    • (1991) Anal Chem , vol.63 , pp. 1467
    • Kennedy, R.1    Jorgenson, J.W.2
  • 50
    • 0016637146 scopus 로고
    • Protein mapping by combined isoelectric focusing and electrophoresis of mouse tissues. A novel approach to testing for induced point mutations in mammals
    • Klose J (1975) Protein mapping by combined isoelectric focusing and electrophoresis of mouse tissues. A novel approach to testing for induced point mutations in mammals. Human-genetik 26:231-243
    • (1975) Human-genetik , vol.26 , pp. 231-243
    • Klose, J.1
  • 51
    • 0025763551 scopus 로고
    • Codon bias and gene expression
    • Kurland CG (1991) Codon bias and gene expression. FEBS Lett 285:165-169
    • (1991) FEBS Lett , vol.285 , pp. 165-169
    • Kurland, C.G.1
  • 52
    • 0033198571 scopus 로고    scopus 로고
    • Subattomole-sensitivity microchip nanoelectrospray source with time-of-flight mass spectrometry detection
    • Lazar IM, Ramsey RS, Sundberg S, Ramsey JM (1999) Subattomole-sensitivity microchip nanoelectrospray source with time-of-flight mass spectrometry detection. Anal Chem 71:3627
    • (1999) Anal Chem , vol.71 , pp. 3627
    • Lazar, I.M.1    Ramsey, R.S.2    Sundberg, S.3    Ramsey, J.M.4
  • 54
    • 0030621966 scopus 로고    scopus 로고
    • Studying noncovalent protein complexes by electrospray ionization mass spectrometry
    • Loo JA (1997) Studying noncovalent protein complexes by electrospray ionization mass spectrometry. Mass Spectrom Rev 16:1-23
    • (1997) Mass Spectrom Rev , vol.16 , pp. 1-23
    • Loo, J.A.1
  • 55
    • 0027461675 scopus 로고
    • Tandem mass spectrometry of very large molecules. 2. Dissociation of multiply charged proline-containing proteins from electrospray ionization
    • Loo JA, Edmonds CG, Smith RD (1993) Tandem mass spectrometry of very large molecules. 2. Dissociation of multiply charged proline-containing proteins from electrospray ionization. Anal Chem 65:425-438
    • (1993) Anal Chem , vol.65 , pp. 425-438
    • Loo, J.A.1    Edmonds, C.G.2    Smith, R.D.3
  • 57
    • 0034655385 scopus 로고    scopus 로고
    • Accurate mass multiplexed tandem mass spectrometry for high-throughput polypeptide identification from mixtures
    • Masselon C, Anderson GA, Harkewicz R, Brace JE, Pasa-Tolic L, Smith RD (2000) Accurate mass multiplexed tandem mass spectrometry for high-throughput polypeptide identification from mixtures. Anal Chem 72:1918-1824
    • (2000) Anal Chem , vol.72 , pp. 1918-11824
    • Masselon, C.1    Anderson, G.A.2    Harkewicz, R.3    Brace, J.E.4    Pasa-Tolic, L.5    Smith, R.D.6
  • 58
    • 0023664635 scopus 로고
    • Sequence from picomole quantities of proteins electroblotted onto polyvinylidene difluoride membranes
    • Matsudaira P (1987) Sequence from picomole quantities of proteins electroblotted onto polyvinylidene difluoride membranes. J Biol Chem 262:10035-10038
    • (1987) J Biol Chem , vol.262 , pp. 10035-10038
    • Matsudaira, P.1
  • 59
    • 0031568420 scopus 로고    scopus 로고
    • Direct analysis and identification of proteins in mixtures by LC/MS/MS and database searching at the low-femtomole level
    • McCormack AL, Schieltz DM, Goode B, Yang S, Barnes G, Drabin D, Yates JR III (1997) Direct analysis and identification of proteins in mixtures by LC/MS/MS and database searching at the low-femtomole level. Anal Chem 69:767-776
    • (1997) Anal Chem , vol.69 , pp. 767-776
    • McCormack, A.L.1    Schieltz, D.M.2    Goode, B.3    Yang, S.4    Barnes, G.5    Drabin, D.6    Yates III, J.R.7
  • 60
  • 61
    • 0026425260 scopus 로고
    • Nanoscale packed capillary liquid chromatography coupled with mass spectrometry using a coaxial continuous flow fast atom bombardment interface
    • Mosely MA, Deterding LJ, Tomer KB, Jorgenson JW (1991) Nanoscale packed capillary liquid chromatography coupled with mass spectrometry using a coaxial continuous flow fast atom bombardment interface. Anal Chem 63:1467-1473
    • (1991) Anal Chem , vol.63 , pp. 1467-1473
    • Mosely, M.A.1    Deterding, L.J.2    Tomer, K.B.3    Jorgenson, J.W.4
  • 62
    • 0033535961 scopus 로고    scopus 로고
    • Accurate quantitation of protein expression and site-specific phosphorylation
    • Oda Y, Huang K, Cross FR, Cowburn D, Chait BT (1999) Accurate quantitation of protein expression and site-specific phosphorylation. Proc Natl Acad Sci USA 96:6591-6596
    • (1999) Proc Natl Acad Sci USA , vol.96 , pp. 6591-6596
    • Oda, Y.1    Huang, K.2    Cross, F.R.3    Cowburn, D.4    Chait, B.T.5
  • 63
    • 0016711037 scopus 로고
    • High resolution two-dimensional electrophoresis of proteins
    • O'Farrell PH (1975) High resolution two-dimensional electrophoresis of proteins. J Biol Chem 250:4007-4021
    • (1975) J Biol Chem , vol.250 , pp. 4007-4021
    • O'Farrell, P.H.1
  • 64
    • 0031184405 scopus 로고    scopus 로고
    • Two-dimensional SEC/RPLC coupled to mass spectrometry for the analysis of peptides
    • Opiteck GJ, Jorgenson JW (1997) Two-dimensional SEC/RPLC coupled to mass spectrometry for the analysis of peptides. Anal Chem 69:2283-2291
    • (1997) Anal Chem , vol.69 , pp. 2283-2291
    • Opiteck, G.J.1    Jorgenson, J.W.2
  • 66
    • 0034659815 scopus 로고    scopus 로고
    • Proteomics to study genes and genomes
    • Pandey A, Mann M (2000) Proteomics to study genes and genomes. Nature 405:837-846
    • (2000) Nature , vol.405 , pp. 837-846
    • Pandey, A.1    Mann, M.2
  • 68
    • 0028142375 scopus 로고
    • From electrophoretically separated protein to identification: Strategies for sequence and mass analysis
    • Patterson SD (1994) From electrophoretically separated protein to identification: strategies for sequence and mass analysis. Anal Biochem 221:1-15
    • (1994) Anal Biochem , vol.221 , pp. 1-15
    • Patterson, S.D.1
  • 69
    • 0028824080 scopus 로고
    • Mass spectrometric approaches for the identification of gel-separated proteins
    • Patterson SD, Aebersold R (1995) Mass spectrometric approaches for the identification of gel-separated proteins. Electrophoresis 16:1791-1814
    • (1995) Electrophoresis , vol.16 , pp. 1791-1814
    • Patterson, S.D.1    Aebersold, R.2
  • 72
    • 84987419408 scopus 로고
    • Proposal for a common nomenclature for sequence ions in mass spectra of peptides
    • Roepstorff P, Fohlman J (1984) Proposal for a common nomenclature for sequence ions in mass spectra of peptides. J Biomed Mass Spectrom 11:601-601
    • (1984) J Biomed Mass Spectrom , vol.11 , pp. 601-601
    • Roepstorff, P.1    Fohlman, J.2
  • 73
    • 0032535467 scopus 로고    scopus 로고
    • Modification of cysteine residues by alkylation. A tool in peptide mapping and protein identification
    • Sechi S, Chait BT (1998) Modification of cysteine residues by alkylation. A tool in peptide mapping and protein identification. Anal Chem 70:5150-5158
    • (1998) Anal Chem , vol.70 , pp. 5150-5158
    • Sechi, S.1    Chait, B.T.2
  • 77
    • 0029669683 scopus 로고    scopus 로고
    • Data-controlled automation of liquid chromatography/tandem mass spectrometry analysis of peptide mixtures
    • Stahl DC, Swiderek KM, Davis MT, Eee TD (1996) Data-controlled automation of liquid chromatography/tandem mass spectrometry analysis of peptide mixtures. J Am Soc Mass Spectrom 7:532-540
    • (1996) J Am Soc Mass Spectrom , vol.7 , pp. 532-540
    • Stahl, D.C.1    Swiderek, K.M.2    Davis, M.T.3    Eee, T.D.4
  • 79
    • 0033168122 scopus 로고    scopus 로고
    • Identification of proteins in complexes by solid-phase microextraction/multistep elution/capillary electrophoresis/tandem mass spectrometry
    • Tong W, Link A, Eng JK, Yates JR 3rd (1999) Identification of proteins in complexes by solid-phase microextraction/multistep elution/capillary electrophoresis/tandem mass spectrometry. Anal Chem 71:2270-2278
    • (1999) Anal Chem , vol.71 , pp. 2270-2278
    • Tong, W.1    Link, A.2    Eng, J.K.3    Yates III, J.R.4
  • 80
    • 0000326573 scopus 로고
    • Attomole level capillary electrophoresis mass spectrometric protein analysis using 5 μ ID capillaries
    • Wahl JH, Goodlett DR, Udseth HR, Smith RD (1992) Attomole level capillary electrophoresis mass spectrometric protein analysis using 5 μ ID capillaries. Anal Chem 64:3194-3196
    • (1992) Anal Chem , vol.64 , pp. 3194-3196
    • Wahl, J.H.1    Goodlett, D.R.2    Udseth, H.R.3    Smith, R.D.4
  • 81
    • 0028351170 scopus 로고
    • Sheathless capillary electrophoresis-electrospray ionization mass spectrometry using 10 μ I.D. capillaries: Analyses of tryptic digests of cytochrome c
    • Wahl JH, Gale DC, Smith RD (1994) Sheathless capillary electrophoresis-electrospray ionization mass spectrometry using 10 μ I.D. capillaries: analyses of tryptic digests of cytochrome c. J Chromatogr A 659:217-222
    • (1994) J Chromatogr A , vol.659 , pp. 217-222
    • Wahl, J.H.1    Gale, D.C.2    Smith, R.D.3
  • 84
    • 0033827629 scopus 로고    scopus 로고
    • Comparative quantification and identification of phosphoproteins using stable isotope labeling and liquid chromatography/mass spectrometry
    • Weckwerth W, Willmitzer L, Fiehn O (2000) Comparative quantification and identification of phosphoproteins using stable isotope labeling and liquid chromatography/mass spectrometry. Rapid Commun Mass Spectrom 14:1677-1681
    • (2000) Rapid Commun Mass Spectrom , vol.14 , pp. 1677-1681
    • Weckwerth, W.1    Willmitzer, L.2    Fiehn, O.3
  • 86
    • 0000217562 scopus 로고
    • Electrospray and Taylor-cone theory, Doles beam of macromolecules at last
    • Wilm MS, Mann M (1994) Electrospray and Taylor-cone theory, Doles beam of macromolecules at last. Int J Mass Spectrom Ion Processes 136:167-180
    • (1994) Int J Mass Spectrom Ion Processes , vol.136 , pp. 167-180
    • Wilm, M.S.1    Mann, M.2
  • 87
    • 0029685702 scopus 로고    scopus 로고
    • Analytical properties of the nanoelectrospray ion source
    • Wilm M, Mann M (1996) Analytical properties of the nanoelectrospray ion source. Anal Chem 68:1-8
    • (1996) Anal Chem , vol.68 , pp. 1-8
    • Wilm, M.1    Mann, M.2
  • 88
    • 0003095924 scopus 로고    scopus 로고
    • De novo sequencing of proteins with mass spectrometry using the differential scanning technique
    • Kamp RM, Kyriakidis D, Choli-Papadopoulou T (eds). Springer, Berlin Heidelberg New York
    • Wilm M, Neubauer G, Taylor L, Shevchenko A, Bachi A (1999) De novo sequencing of proteins with mass spectrometry using the differential scanning technique. In: Kamp RM, Kyriakidis D, Choli-Papadopoulou T (eds) Proteome and protein analysis. Springer, Berlin Heidelberg New York, pp 65-80
    • (1999) Proteome and Protein Analysis , pp. 65-80
    • Wilm, M.1    Neubauer, G.2    Taylor, L.3    Shevchenko, A.4    Bachi, A.5
  • 89
    • 0035384687 scopus 로고    scopus 로고
    • Proteolytic 18O labeling for comparative proteomics: Model studies with two serotypes of adenovirus
    • Yao X, Freas A, Ramirez J, Demirev PA, Fenselau C (2001) Proteolytic 18O labeling for comparative proteomics: model studies with two serotypes of adenovirus. Anal Chem 73:2836-2842
    • (2001) Anal Chem , vol.73 , pp. 2836-2842
    • Yao, X.1    Freas, A.2    Ramirez, J.3    Demirev, P.A.4    Fenselau, C.5
  • 90
    • 0033621537 scopus 로고    scopus 로고
    • Mass spectrometry. From genomics to proteomics
    • Yates JR III (2000) Mass spectrometry. From genomics to proteomics. Trends Genet 16:5-8
    • (2000) Trends Genet , vol.16 , pp. 5-8
    • Yates III, J.R.1
  • 91
    • 0029645432 scopus 로고
    • Mining genomes: Correlating tandem mass spectra of modified and unmodified peptides to sequences in nucleotide databases
    • Yates JR III, Eng JK, McCormack AL (1995a) Mining genomes: correlating tandem mass spectra of modified and unmodified peptides to sequences in nucleotide databases. Anal Chem 67:3202-3210.
    • (1995) Anal Chem , vol.67 , pp. 3202-3210
    • Yates III, J.R.1    Eng, J.K.2    McCormack, A.L.3
  • 92
    • 0029644596 scopus 로고
    • Method to correlate tandem mass spectra of modified peptides to amino acid sequences in the protein database
    • Yates JR III, Eng JK, McCormack AL, Schieltz D (1995b) Method to correlate tandem mass spectra of modified peptides to amino acid sequences in the protein database. Anal Chem 67:1426-1436
    • (1995) Anal Chem , vol.67 , pp. 1426-1436
    • Yates III, J.R.1    Eng, J.K.2    McCormack, A.L.3    Schieltz, D.4
  • 95
    • 0034161639 scopus 로고    scopus 로고
    • A microdevice with integrated liquid junction for facile peptide and protein analysis by capillary electrophoresis/electrospray mass spectrometry
    • Zhang B, Foret F, Karger BL (2000) A microdevice with integrated liquid junction for facile peptide and protein analysis by capillary electrophoresis/electrospray mass spectrometry. Anal Chem 72:1015-1022
    • (2000) Anal Chem , vol.72 , pp. 1015-1022
    • Zhang, B.1    Foret, F.2    Karger, B.L.3
  • 96
    • 0035252675 scopus 로고    scopus 로고
    • Protein arrays and microarrays
    • Zhu H, Snyder M (2001) Protein arrays and microarrays. Curr Opin Chem Biol 5:40-45
    • (2001) Curr Opin Chem Biol , vol.5 , pp. 40-45
    • Zhu, H.1    Snyder, M.2
  • 98
    • 2742576125 scopus 로고    scopus 로고
    • Accuracy requirements for peptide characterization by monoisotopic molecular mass measurements
    • Zubarev RA, Hakansson P, Sundqvist B (1996) Accuracy requirements for peptide characterization by monoisotopic molecular mass measurements. Anal Chem 68:4060-4063
    • (1996) Anal Chem , vol.68 , pp. 4060-4063
    • Zubarev, R.A.1    Hakansson, P.2    Sundqvist, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.