메뉴 건너뛰기




Volumn 71, Issue , 2014, Pages 15-24

State of art: Optically stimulated luminescence dosimetry - Frontiers of future research

Author keywords

Aluminum oxide; Dosimetry; Luminescent materials; Optically stimulated luminescence; Thermoluminescence

Indexed keywords

DOSIMETRY; MEDICAL PROBLEMS; THERMOLUMINESCENCE;

EID: 85027933880     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2014.03.023     Document Type: Conference Paper
Times cited : (90)

References (132)
  • 1
    • 84859623771 scopus 로고    scopus 로고
    • SU-FF-T-306: Optically stimulated light dosimetry: Commissioning of an optically stimulated luminescence (OSL) system for remote dosimetry audits, the radiological physics Center experience
    • Aguirre, J., Alvarez, P., Followill, D., Ibbott, G., Amador, C., Tailor, R., 2009. SU-FF-T-306: optically stimulated light dosimetry: commissioning of an optically stimulated luminescence (OSL) system for remote dosimetry audits, the radiological physics Center experience. Med. Phys. 36, 2591-2592.
    • (2009) Med. Phys. , vol.36 , pp. 2591-2592
    • Aguirre, J.1    Alvarez, P.2    Followill, D.3    Ibbott, G.4    Amador, C.5    Tailor, R.6
  • 6
    • 0032910059 scopus 로고    scopus 로고
    • A radiation dosimetry method using pulsed optically stimulated luminescence
    • Akselrod, M.S., McKeever, S.W.S., 1999. A radiation dosimetry method using pulsed optically stimulated luminescence. Radiat. Prot. Dosim. 81, 167-176.
    • (1999) Radiat. Prot. Dosim. , vol.81 , pp. 167-176
    • Akselrod, M.S.1    McKeever, S.W.S.2
  • 7
    • 0033747471 scopus 로고    scopus 로고
    • A procedure for the distinction between static and dynamic radiation exposures of personal radiation badges using pulsed optically stimulated luminescence
    • Akselrod, M.S., Agersnap Larsen, N., McKeever, S.W.S., 2000. A procedure for the distinction between static and dynamic radiation exposures of personal radiation badges using pulsed optically stimulated luminescence. Radiat. Meas. 32, 215-225.
    • (2000) Radiat. Meas. , vol.32 , pp. 215-225
    • Akselrod, M.S.1    Agersnap Larsen, N.2    McKeever, S.W.S.3
  • 8
    • 3543093830 scopus 로고    scopus 로고
    • Fluorescent aluminum oxide crystals for volumetric optical data storage and imaging applications
    • Akselrod, M.S., Akselrod, A.E., Orlov, S.S., Sanyal, S., Underwood, T.H., 2003. Fluorescent aluminum oxide crystals for volumetric optical data storage and imaging applications. J. Fluoresc. 13, 503-511.
    • (2003) J. Fluoresc. , vol.13 , pp. 503-511
    • Akselrod, M.S.1    Akselrod, A.E.2    Orlov, S.S.3    Sanyal, S.4    Underwood, T.H.5
  • 9
    • 84862564263 scopus 로고    scopus 로고
    • Estimating thyroid dose in pediatric CT exams from surface dose measurements
    • Al-Senan, R., Mueller, D.L., Hatab, M.R., 2012. Estimating thyroid dose in pediatric CT exams from surface dose measurements. Phys. Med. Biol. 57, 4211-4221.
    • (2012) Phys. Med. Biol. , vol.57 , pp. 4211-4221
    • Al-Senan, R.1    Mueller, D.L.2    Hatab, M.R.3
  • 10
    • 79960224631 scopus 로고    scopus 로고
    • Characteristics of an OSLD in the diagnostic energy range
    • Al-Senan, R.M., Hatab, M.R., 2011. Characteristics of an OSLD in the diagnostic energy range. Med. Phys. 38, 4396-4405.
    • (2011) Med. Phys. , vol.38 , pp. 4396-4405
    • Al-Senan, R.M.1    Hatab, M.R.2
  • 11
    • 22644445292 scopus 로고
    • Storage of energy in beryllium oxide
    • Albrecht, H.O., Mandeville, C.E., 1956. Storage of energy in beryllium oxide. Phys. Rev. 101, 1250-1252.
    • (1956) Phys. Rev. , vol.101 , pp. 1250-1252
    • Albrecht, H.O.1    Mandeville, C.E.2
  • 14
    • 34548247814 scopus 로고    scopus 로고
    • Medical proton dosimetry using radioluminescence from aluminium oxide crystals attached to optical fiber cables
    • Andersen, C.E., Edmund, J.M., Medin, J., Grusell, E., Jain, M., Mattsson, S., 2007. Medical proton dosimetry using radioluminescence from aluminium oxide crystals attached to optical fiber cables. Nucl. Instrum. Methods. Phys. Res. A 580, 466-468.
    • (2007) Nucl. Instrum. Methods. Phys. Res. A , vol.580 , pp. 466-468
    • Andersen, C.E.1    Edmund, J.M.2    Medin, J.3    Grusell, E.4    Jain, M.5    Mattsson, S.6
  • 19
    • 0036390453 scopus 로고    scopus 로고
    • Luminescence characteristics of dental ceramics for retrospective dosimetry: A preliminary study
    • Bailiff, I.K., Correcher, V., Delgado, A., Göksu, Y., Hübner, S., 2002. Luminescence characteristics of dental ceramics for retrospective dosimetry: a preliminary study. Radiat. Prot. Dosim. 101, 519-524.
    • (2002) Radiat. Prot. Dosim. , vol.101 , pp. 519-524
    • Bailiff, I.K.1    Correcher, V.2    Delgado, A.3    Göksu, Y.4    Hübner, S.5
  • 21
    • 77955307899 scopus 로고    scopus 로고
    • Performance studies of an optical fiber OSL/RL dosimetry system in pulsed high-intensity radiation beams
    • Benoit, D., Dusseau, L., Glaser, M., Mukherjee, B., Ravotti, F., 2010. Performance studies of an optical fiber OSL/RL dosimetry system in pulsed high-intensity radiation beams. Radiat. Meas. 45, 688-690.
    • (2010) Radiat. Meas. , vol.45 , pp. 688-690
    • Benoit, D.1    Dusseau, L.2    Glaser, M.3    Mukherjee, B.4    Ravotti, F.5
  • 23
    • 33749820744 scopus 로고    scopus 로고
    • Dosimetry of densely ionising radiation with three LiF phosphors for space applications
    • Bilski, P., 2006. Dosimetry of densely ionising radiation with three LiF phosphors for space applications. Radiat. Prot. Dosim. 120, 397-400.
    • (2006) Radiat. Prot. Dosim. , vol.120 , pp. 397-400
    • Bilski, P.1
  • 24
    • 76049090860 scopus 로고    scopus 로고
    • On the correctness of the thermoluminescent high-temperature ratio (HTR) method for estimating ionization density effects in mixed radiation fields
    • Bilski, P., 2010. On the correctness of the thermoluminescent high-temperature ratio (HTR) method for estimating ionization density effects in mixed radiation fields. Radiat. Meas. 45, 42-50.
    • (2010) Radiat. Meas. , vol.45 , pp. 42-50
    • Bilski, P.1
  • 26
    • 0035445924 scopus 로고    scopus 로고
    • High sensitivity thermoluminescence dosimetry
    • Bos, A.J.J., 2001. High sensitivity thermoluminescence dosimetry. Nucl. Instrum. Methods. Phys. Res. B 184, 3-28.
    • (2001) Nucl. Instrum. Methods. Phys. Res. B , vol.184 , pp. 3-28
    • Bos, A.J.J.1
  • 31
    • 77955308043 scopus 로고    scopus 로고
    • Review of optically stimulated luminescence (OSL) instrumental developments for retrospective dosimetry
    • Bøtter-Jensen, L., Thomsen, K.J., Jain, M., 2010. Review of optically stimulated luminescence (OSL) instrumental developments for retrospective dosimetry. Radiat. Meas. 45, 253-257.
    • (2010) Radiat. Meas. , vol.45 , pp. 253-257
    • Bøtter-Jensen, L.1    Thomsen, K.J.2    Jain, M.3
  • 32
    • 0032291837 scopus 로고    scopus 로고
    • OSL from BeO ceramics: New observations from an old material
    • Bulur, E., Göksu, H.Y., 1998. OSL from BeO ceramics: new observations from an old material. Radiat. Meas. 29, 639-650.
    • (1998) Radiat. Meas. , vol.29 , pp. 639-650
    • Bulur, E.1    Göksu, H.Y.2
  • 33
    • 84889100166 scopus 로고    scopus 로고
    • Time-resolved OSL studies on BeO ceramics
    • Bulur, E., Sarac¸, B.E., 2013. Time-resolved OSL studies on BeO ceramics. Radiat. Meas. 59, 129-138.
    • (2013) Radiat. Meas. , vol.59 , pp. 129-138
    • Bulur, E.1    Sarac¸, B.E.2
  • 38
    • 84883149706 scopus 로고    scopus 로고
    • An optically stimulated luminescence dosimeter for measuring patient exposure from imaging guidance procedures
    • Ding, G.X., Malcolm, A.W., 2013. An optically stimulated luminescence dosimeter for measuring patient exposure from imaging guidance procedures. Phys. Med. Biol. 58, 5885-5897.
    • (2013) Phys. Med. Biol. , vol.58 , pp. 5885-5897
    • Ding, G.X.1    Malcolm, A.W.2
  • 41
    • 77955309867 scopus 로고    scopus 로고
    • Demonstrating the use of optically stimulated luminescence dosimeters (OSLDs) for measurement of staff radiation exposure in interventional fluoroscopy and helmet output factors in radiosurgery
    • Gasparian, P.B.R., Ruan, C., Ahmad, S., Kalavagunta, C., Chen, C.Y., Yukihara, E.G., 2010. Demonstrating the use of optically stimulated luminescence dosimeters (OSLDs) for measurement of staff radiation exposure in interventional fluoroscopy and helmet output factors in radiosurgery. Radiat. Meas. 45, 677-680.
    • (2010) Radiat. Meas. , vol.45 , pp. 677-680
    • Gasparian, P.B.R.1    Ruan, C.2    Ahmad, S.3    Kalavagunta, C.4    Chen, C.Y.5    Yukihara, E.G.6
  • 44
    • 84878939091 scopus 로고    scopus 로고
    • Comparative dose evaluations between XVI and OBI cone beam CT systems using Gafchromic XRQA2 film and nanoDot optical stimulated luminescence detectors
    • Giaddui, T., Cui, Y., Galvin, J., Yu, Y., Xiao, Y., 2013. Comparative dose evaluations between XVI and OBI cone beam CT systems using Gafchromic XRQA2 film and nanoDot optical stimulated luminescence detectors. Med. Phys. 40, 062102.
    • (2013) Med. Phys. , vol.40 , pp. 062102
    • Giaddui, T.1    Cui, Y.2    Galvin, J.3    Yu, Y.4    Xiao, Y.5
  • 45
    • 45049088315 scopus 로고    scopus 로고
    • Towards in vivo OSL dosimetry of human tooth enamel
    • Godfrey-Smith, D.I., 2008. Towards in vivo OSL dosimetry of human tooth enamel. Radiat. Meas. 43, 854-858.
    • (2008) Radiat. Meas. , vol.43 , pp. 854-858
    • Godfrey-Smith, D.I.1
  • 48
    • 84880225513 scopus 로고    scopus 로고
    • Development of Procedures for in Vivo Dosimetry in Radiotherapy
    • International Atomic Energy Agency, Vienna, Austria
    • IAEA, 2013. Development of Procedures for in Vivo Dosimetry in Radiotherapy. Human Health Reports No. 8. International Atomic Energy Agency, Vienna, Austria.
    • (2013) Human Health Reports
    • IAEA1
  • 49
    • 0009992291 scopus 로고    scopus 로고
    • ICRU Report 66: Determination of operational dose equivalent quantities for neutrons
    • ICRU, 2001. ICRU Report 66: determination of operational dose equivalent quantities for neutrons. J. ICRU 1, 1-93.
    • (2001) J. ICRU , vol.1 , pp. 1-93
    • ICRU1
  • 50
    • 85028166390 scopus 로고    scopus 로고
    • ICRU Report 68: Retrospective Assessment of Exposure to Ionizing Radiation
    • ICRU, 2002. ICRU Report 68: Retrospective Assessment of Exposure to Ionizing Radiation. J. ICRU 2.
    • (2002) J. ICRU , vol.2
    • ICRU1
  • 52
    • 45249117719 scopus 로고    scopus 로고
    • Optically stimulated luminescence of electronic components for forensic, retrospective, and accident dosimetry
    • Inrig, E.L., Godfrey-Smith, D.I., Khanna, S., 2008. Optically stimulated luminescence of electronic components for forensic, retrospective, and accident dosimetry. Radiat. Meas. 43, 726-730.
    • (2008) Radiat. Meas. , vol.43 , pp. 726-730
    • Inrig, E.L.1    Godfrey-Smith, D.I.2    Khanna, S.3
  • 53
    • 77955306466 scopus 로고    scopus 로고
    • Fading corrections to electronic component substrates in retrospective accident dosimetry
    • Inrig, E.L., Godfrey-Smith, D.I., Larsson, C.L., 2010. Fading corrections to electronic component substrates in retrospective accident dosimetry. Radiat. Meas. 45, 608-610.
    • (2010) Radiat. Meas. , vol.45 , pp. 608-610
    • Inrig, E.L.1    Godfrey-Smith, D.I.2    Larsson, C.L.3
  • 54
    • 82355169784 scopus 로고    scopus 로고
    • Progress in 2D-OSL-dosimetry with beryllium oxide
    • Jahn, A., Sommer, M., Liebmann, M., Henniger, J., 2011. Progress in 2D-OSL-dosimetry with beryllium oxide. Radiat. Meas. 46, 1908-1911.
    • (2011) Radiat. Meas. , vol.46 , pp. 1908-1911
    • Jahn, A.1    Sommer, M.2    Liebmann, M.3    Henniger, J.4
  • 55
    • 84884817376 scopus 로고    scopus 로고
    • The BeOmax system edosimetry using OSL of BeO for several applications
    • Jahn, A., Sommer, M., Ullrich, W., Wickert, M., Henniger, J., 2013. The BeOmax system edosimetry using OSL of BeO for several applications. Radiat. Meas. 56, 324-327.
    • (2013) Radiat. Meas. , vol.56 , pp. 324-327
    • Jahn, A.1    Sommer, M.2    Ullrich, W.3    Wickert, M.4    Henniger, J.5
  • 56
    • 36749049838 scopus 로고    scopus 로고
    • Characterization of optically stimulated luminescence dosimeters, OSLDs, for clinical dosimetric measurements
    • Jursinic, P.A., 2007. Characterization of optically stimulated luminescence dosimeters, OSLDs, for clinical dosimetric measurements. Med. Phys. 34, 4594-4604.
    • (2007) Med. Phys. , vol.34 , pp. 4594-4604
    • Jursinic, P.A.1
  • 57
    • 73649095518 scopus 로고    scopus 로고
    • Changes in optically stimulated luminescent dosimeter (OSLD) dosimetric characteristics with accumulated dose
    • Jursinic, P.A., 2010. Changes in optically stimulated luminescent dosimeter (OSLD) dosimetric characteristics with accumulated dose. Med. Phys. 37, 132-140.
    • (2010) Med. Phys. , vol.37 , pp. 132-140
    • Jursinic, P.A.1
  • 58
    • 80053583970 scopus 로고    scopus 로고
    • In vivo dosimetry with optically stimulated luminescent dosimeters, OSLDs, compared to diodes; effects of buildup cap thickness and fabrication material
    • Jursinic, P.A., Yahnke, C.J., 2011. In vivo dosimetry with optically stimulated luminescent dosimeters, OSLDs, compared to diodes; effects of buildup cap thickness and fabrication material. Med. Phys. 38, 5432-5440.
    • (2011) Med. Phys. , vol.38 , pp. 5432-5440
    • Jursinic, P.A.1    Yahnke, C.J.2
  • 59
    • 85092678407 scopus 로고    scopus 로고
    • Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors
    • Karsch, L., Beyureuther, E., Burris-Mog, T., Kraft, S., Richter, C., Zeil, K., 2012. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors. Med. Phys. 5.
    • (2012) Med. Phys. , vol.5
    • Karsch, L.1    Beyureuther, E.2    Burris-Mog, T.3    Kraft, S.4    Richter, C.5    Zeil, K.6
  • 64
    • 84860358089 scopus 로고    scopus 로고
    • Storage phosphors for medical imaging
    • Leblans, P., Vandenbroucke, D., Willems, P., 2011. Storage phosphors for medical imaging. Materials 4, 1034-1086.
    • (2011) Materials , vol.4 , pp. 1034-1086
    • Leblans, P.1    Vandenbroucke, D.2    Willems, P.3
  • 65
    • 26544442660 scopus 로고
    • Luminescence of the F center in sapphire
    • Lee, K.H., Crawford Jr., J.H., 1979. Luminescence of the F center in sapphire. Phys. Rev. B 19, 3217-3221.
    • (1979) Phys. Rev. B , vol.19 , pp. 3217-3221
    • Lee, K.H.1    Crawford, J.H.2
  • 67
    • 84921512018 scopus 로고    scopus 로고
    • SU-C-213CD-02: The use of optically stimulated luminescent dosimeters in a cone beam quality assurance testing
    • Lovelock, D., Lim, S., LoSasson, T., 2012. SU-C-213CD-02: the use of optically stimulated luminescent dosimeters in a cone beam quality assurance testing. Med. Phys. 39, 3604.
    • (2012) Med. Phys. , vol.39 , pp. 3604
    • Lovelock, D.1    Lim, S.2    LoSasson, T.3
  • 68
    • 28244472380 scopus 로고    scopus 로고
    • Parallel solution combustion synthesis for combinatorial materials studies
    • Luo, Z.L., Geng, B., Bao, J., Gao, C., 2005. Parallel solution combustion synthesis for combinatorial materials studies. J. Comb. Chem. 7, 942-946.
    • (2005) J. Comb. Chem. , vol.7 , pp. 942-946
    • Luo, Z.L.1    Geng, B.2    Bao, J.3    Gao, C.4
  • 72
    • 0141782293 scopus 로고    scopus 로고
    • On the advantages and disadvantages of optically stimulated luminescence dosimetry and thermoluminescence dosimetry
    • McKeever, S.W.S., Moscovitch, M., 2003. On the advantages and disadvantages of optically stimulated luminescence dosimetry and thermoluminescence dosimetry. Radiat. Prot. Dosim. 104, 263-270.
    • (2003) Radiat. Prot. Dosim. , vol.104 , pp. 263-270
    • McKeever, S.W.S.1    Moscovitch, M.2
  • 78
    • 77955310002 scopus 로고    scopus 로고
    • Effect of deep traps on sensitivity of TLD-500 thermoluminescent detectors
    • Nikiforov, S.V., Kortov, V.S., 2010. Effect of deep traps on sensitivity of TLD-500 thermoluminescent detectors. Radiat. Meas. 45, 527-529.
    • (2010) Radiat. Meas. , vol.45 , pp. 527-529
    • Nikiforov, S.V.1    Kortov, V.S.2
  • 79
    • 84868710431 scopus 로고    scopus 로고
    • Development and characterization of MgO: Nd,Li synthesized by solution combustion synthesis for 2D optically stimulated luminescence dosimetry
    • Oliveira, L.C., Milliken, E.D., Yukihara, E.G., 2013a. Development and characterization of MgO: Nd,Li synthesized by solution combustion synthesis for 2D optically stimulated luminescence dosimetry. J. Lumin 133, 211-216.
    • (2013) J. Lumin , vol.133 , pp. 211-216
    • Oliveira, L.C.1    Milliken, E.D.2    Yukihara, E.G.3
  • 80
    • 84873623338 scopus 로고    scopus 로고
    • Investigations of MgO: Li,Gd thermally and optically stimulated luminescence
    • Oliveira, L.C., Doull, B.A., Yukihara, E.G., 2013b. Investigations of MgO: Li,Gd thermally and optically stimulated luminescence. J. Lumin 137, 282-289.
    • (2013) J. Lumin , vol.137 , pp. 282-289
    • Oliveira, L.C.1    Doull, B.A.2    Yukihara, E.G.3
  • 82
    • 80053569854 scopus 로고    scopus 로고
    • Optically stimulated luminescence in LiF: Mg,Ti: Application to solid-state radiation dosimetry
    • Oster, L., Druzhyna, S., Horowitz, Y.S., 2011. Optically stimulated luminescence in LiF: Mg,Ti: application to solid-state radiation dosimetry. Nucl. Instrum. Methods. Phys. Res. A 648, 261-265.
    • (2011) Nucl. Instrum. Methods. Phys. Res. A , vol.648 , pp. 261-265
    • Oster, L.1    Druzhyna, S.2    Horowitz, Y.S.3
  • 83
    • 33750017101 scopus 로고    scopus 로고
    • Nonmonotonic dose dependence of OSL intensity due to competition during irradiation and readout
    • Pagonis, V., Chen, R., Lawless, J.L., 2006. Nonmonotonic dose dependence of OSL intensity due to competition during irradiation and readout. Radiat. Meas. 41, 903-909.
    • (2006) Radiat. Meas. , vol.41 , pp. 903-909
    • Pagonis, V.1    Chen, R.2    Lawless, J.L.3
  • 84
    • 52249097690 scopus 로고    scopus 로고
    • Introduction of the InLight monitoring service
    • Perks, C.A., Le Roy, G., Prugnaud, B., 2007. Introduction of the InLight monitoring service. Radiat. Prot. Dosim. 125, 220-223.
    • (2007) Radiat. Prot. Dosim. , vol.125 , pp. 220-223
    • Perks, C.A.1    Le Roy, G.2    Prugnaud, B.3
  • 89
    • 52249121207 scopus 로고    scopus 로고
    • Recent developments of optically stimulated luminescence materials and techniques for radiation dosimetry and clinical applications
    • Pradhan, A.S., Lee, J.I., Kim, J.L., 2008. Recent developments of optically stimulated luminescence materials and techniques for radiation dosimetry and clinical applications. J. Med. Phys. 33, 85-99.
    • (2008) J. Med. Phys. , vol.33 , pp. 85-99
    • Pradhan, A.S.1    Lee, J.I.2    Kim, J.L.3
  • 91
    • 11044235032 scopus 로고    scopus 로고
    • Conception of an integrated sensor for the radiation monitoring of the CMS experiment at the Large Hadron Collider
    • Ravotti, F., Glaser, M., Moll, M., Idri, K., Vaillé, J.R., Prevost, H., Dusseau, L., 2004. Conception of an integrated sensor for the radiation monitoring of the CMS experiment at the Large Hadron Collider. IEEE Trans. Nucl. Sci. 51, 3642-3648.
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , pp. 3642-3648
    • Ravotti, F.1    Glaser, M.2    Moll, M.3    Idri, K.4    Vaillé, J.R.5    Prevost, H.6    Dusseau, L.7
  • 92
    • 33749409973 scopus 로고    scopus 로고
    • In vivo and phantom measurements of the secondary photon and neutron doses for prostate patients undergoing 18 MV IMRT
    • Reft, C.S., Runkel-Muller, R., Myrianthopoulos, L., 2006. In vivo and phantom measurements of the secondary photon and neutron doses for prostate patients undergoing 18 MV IMRT. Med. Phys. 33, 3734-3742.
    • (2006) Med. Phys. , vol.33 , pp. 3734-3742
    • Reft, C.S.1    Runkel-Muller, R.2    Myrianthopoulos, L.3
  • 93
    • 65449186980 scopus 로고    scopus 로고
    • The energy dependence and dose response of a commercial optically stimulated luminescence detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams
    • Reft, C.S., 2009. The energy dependence and dose response of a commercial optically stimulated luminescence detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams. Med. Phys. 36, 1690-1699.
    • (2009) Med. Phys. , vol.36 , pp. 1690-1699
    • Reft, C.S.1
  • 95
    • 77954707608 scopus 로고    scopus 로고
    • Determination of multi-slice computed tomography dose index (CTDI) using optically stimulated luminescence technology
    • Ruan, C., Yukihara, E.G., Clouse, W.J., Gasparian, P.B.R., Ahmad, S., 2010. Determination of multi-slice computed tomography dose index (CTDI) using optically stimulated luminescence technology. Med. Phys. 37, 3560-3568.
    • (2010) Med. Phys. , vol.37 , pp. 3560-3568
    • Ruan, C.1    Yukihara, E.G.2    Clouse, W.J.3    Gasparian, P.B.R.4    Ahmad, S.5
  • 98
    • 84855579273 scopus 로고    scopus 로고
    • 3:C optically stimulated luminescence detectors exposed to high-energy heavy charged particles
    • 3:C optically stimulated luminescence detectors exposed to high-energy heavy charged particles. Phys. Med. Biol. 57, 437-454.
    • (2012) Phys. Med. Biol. , vol.57 , pp. 437-454
    • Sawakuchi, G.O.1    Yukihara, E.G.2
  • 99
    • 0014857306 scopus 로고
    • Dosimetric use of beryllium oxide as a thermoluminescent material - A preliminary study
    • Scarpa, G., 1970. Dosimetric use of beryllium oxide as a thermoluminescent material - a preliminary study. Phys. Med. Biol. 15, 667-672.
    • (1970) Phys. Med. Biol. , vol.15 , pp. 667-672
    • Scarpa, G.1
  • 100
    • 34447299153 scopus 로고    scopus 로고
    • 3:C) for film dosimetry in radiotherapy
    • 3:C) for film dosimetry in radiotherapy. Med. Phys. 34, 2113-2118.
    • (2007) Med. Phys. , vol.34 , pp. 2113-2118
    • Schembri, V.1    Heijmen, B.J.M.2
  • 102
    • 84880232522 scopus 로고    scopus 로고
    • In vivo measurements for high dose rate brachytherapy with optically stimulated luminescent dosimeters
    • Sharma, R., Jursinic, P.A., 2013. In vivo measurements for high dose rate brachytherapy with optically stimulated luminescent dosimeters. Med. Phys. 40, 071730.
    • (2013) Med. Phys. , vol.40 , pp. 071730
    • Sharma, R.1    Jursinic, P.A.2
  • 103
    • 80052946491 scopus 로고    scopus 로고
    • Emergency dose estimation using optically stimulated luminescence from human tooth enamel
    • Sholom, S., DeWitt, R., Simon, S.L., Bouville, A., McKeever, S.W.S., 2011. Emergency dose estimation using optically stimulated luminescence from human tooth enamel. Radiat. Meas. 46, 778-782.
    • (2011) Radiat. Meas. , vol.46 , pp. 778-782
    • Sholom, S.1    DeWitt, R.2    Simon, S.L.3    Bouville, A.4    McKeever, S.W.S.5
  • 104
    • 84892623433 scopus 로고    scopus 로고
    • Emergency OSL dosimetry with commonplace materials
    • Sholom, S., McKeever, S.W.S., 2014. Emergency OSL dosimetry with commonplace materials. Radiat. Meas. 61, 33-51.
    • (2014) Radiat. Meas. , vol.61 , pp. 33-51
    • Sholom, S.1    McKeever, S.W.S.2
  • 106
    • 79958801160 scopus 로고    scopus 로고
    • Surface dose measurement for helical tomotherapy
    • Snir, J.A., Mosalaei, H., Jordan, K., Yartsev, S., 2011. Surface dose measurement for helical tomotherapy. Med. Phys. 38, 3104-3107.
    • (2011) Med. Phys. , vol.38 , pp. 3104-3107
    • Snir, J.A.1    Mosalaei, H.2    Jordan, K.3    Yartsev, S.4
  • 107
    • 33749684280 scopus 로고    scopus 로고
    • Investigation of a BeO-based optically stimulated luminescence dosimeter
    • Sommer, M., Henniger, J., 2006. Investigation of a BeO-based optically stimulated luminescence dosimeter. Radiat. Prot. Dosim. 119, 394-397.
    • (2006) Radiat. Prot. Dosim. , vol.119 , pp. 394-397
    • Sommer, M.1    Henniger, J.2
  • 111
    • 4644229252 scopus 로고    scopus 로고
    • Neutron detection and neutron dosimetry
    • van Eijk, C.W.E., 2004. Neutron detection and neutron dosimetry. Radiat. Prot. Dosim. 110, 5-13.
    • (2004) Radiat. Prot. Dosim. , vol.110 , pp. 5-13
    • Van Eijk, C.W.E.1
  • 114
    • 84868597448 scopus 로고    scopus 로고
    • Technical Note: Precision and accuracy of a commercially available CT optically stimulated luminescent dosimetry system for the measurement of CT dose index
    • Vrieze, T.J., Sturchio, G.M., McCollough, C.H., 2012. Technical Note: precision and accuracy of a commercially available CT optically stimulated luminescent dosimetry system for the measurement of CT dose index. Med. Phys. 39, 6580-6584.
    • (2012) Med. Phys. , vol.39 , pp. 6580-6584
    • Vrieze, T.J.1    Sturchio, G.M.2    McCollough, C.H.3
  • 115
    • 84870291859 scopus 로고    scopus 로고
    • On the use of OSL of chip card modules with molding for retrospective and accident dosimetry
    • Woda, C., Fiedler, I., Spöttl, T., 2012. On the use of OSL of chip card modules with molding for retrospective and accident dosimetry. Radiat. Meas. 47, 1068-1073.
    • (2012) Radiat. Meas. , vol.47 , pp. 1068-1073
    • Woda, C.1    Fiedler, I.2    Spöttl, T.3
  • 116
    • 82355182187 scopus 로고    scopus 로고
    • The recent investigations of radiophotoluminescence and its application
    • Yamamoto, T., Maki, D., Sato, F., Miyamoto, Y., Nanto, H., Iida, T., 2011. The recent investigations of radiophotoluminescence and its application. Radiat. Meas. 46, 1554-1559.
    • (2011) Radiat. Meas. , vol.46 , pp. 1554-1559
    • Yamamoto, T.1    Maki, D.2    Sato, F.3    Miyamoto, Y.4    Nanto, H.5    Iida, T.6
  • 117
    • 84861594270 scopus 로고    scopus 로고
    • A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity
    • Yao, R., Bernard, D., Turian, J., Abrams, R.A., Sensakovic, W., Fung, H.C., Chu, J.C.H., 2012. A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity. Med. Phys. 39, 2239-2248.
    • (2012) Med. Phys. , vol.39 , pp. 2239-2248
    • Yao, R.1    Bernard, D.2    Turian, J.3    Abrams, R.A.4    Sensakovic, W.5    Fung, H.C.6    Chu, J.C.H.7
  • 126
    • 44949208497 scopus 로고    scopus 로고
    • Development of new optically stimulated luminescence neutron dosimeters
    • Yukihara, E.G., Mittani, J.C.R., Vanhavere, F., Akselrod, M.S., 2008a. Development of new optically stimulated luminescence neutron dosimeters. Radiat. Meas. 43, 309-314.
    • (2008) Radiat. Meas. , vol.43 , pp. 309-314
    • Yukihara, E.G.1    Mittani, J.C.R.2    Vanhavere, F.3    Akselrod, M.S.4
  • 127
    • 37549059594 scopus 로고    scopus 로고
    • 3:C Optically Stimulated Luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy
    • 3:C Optically Stimulated Luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy. Med. Phys. 35, 260-269.
    • (2008) Med. Phys. , vol.35 , pp. 260-269
    • Yukihara, E.G.1    Mardirossian, G.2    Mirzasadeghi, M.3    Guduru, S.4    Ahmad, S.5
  • 130
    • 79959511680 scopus 로고    scopus 로고
    • Luminescence properties of BeO optically stimulated luminescence (OSL) detectors
    • Yukihara, E.G., 2011. Luminescence properties of BeO optically stimulated luminescence (OSL) detectors. Radiat. Meas. 46, 580-587.
    • (2011) Radiat. Meas. , vol.46 , pp. 580-587
    • Yukihara, E.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.