메뉴 건너뛰기




Volumn 58, Issue 12, 2013, Pages 4357-4366

Performance of KCl:Eu2+ storage phosphor dosimeters for low-dose measurements

Author keywords

[No Author keywords available]

Indexed keywords

CLINICAL APPLICATION; ENERGY DEPENDENCE; PHOTO STIMULATED LUMINESCENCE; POTASSIUM CHLORIDE; RECENT RESEARCHES; STORAGE PHOSPHORS; THERMAL-ANNEALING; THERMOLUMINESCENT DOSIMETERS;

EID: 84878871504     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/58/12/4357     Document Type: Article
Times cited : (15)

References (22)
  • 1
    • 0032874911 scopus 로고    scopus 로고
    • AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
    • DOI 10.1118/1.598691
    • Almond P R, Biggs P J, Coursey B M, Hanson W F, Huq M S, Nath R and Rogers D W 1999 AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams Med. Phys. 26 1847-70 (Pubitemid 29442268)
    • (1999) Medical Physics , vol.26 , Issue.9 , pp. 1847-1870
    • Almond, P.R.1    Biggs, P.J.2    Coursey, B.M.3    Hanson, W.F.4    Huq, M.S.5    Nath, R.6    Rogers, D.W.O.7
  • 2
    • 84870935210 scopus 로고    scopus 로고
    • Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams
    • 10.1118/1.4767770 0094-2405
    • Brown T A, Hogstrom K R, Alvarez D, Matthews K L 2nd, Ham K and Dugas J P 2012 Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams Med. Phys. 39 7412-7
    • (2012) Med. Phys. , vol.39 , Issue.12 , pp. 7412-7417
    • Brown, T.A.1    Hogstrom, K.R.2    Alvarez, D.3    Matthews, K.L.4    Ham, K.5    Dugas, J.P.6
  • 3
    • 13444278584 scopus 로고    scopus 로고
    • Peripheral dose measurement with a MOSFET detector
    • DOI 10.1016/j.apradiso.2004.09.001, PII S0969804304004993
    • Butson M J, Cheung T and Yu P K 2005 Peripheral dose measurement with a MOSFET detector Appl. Radiat. Isot. 62 631-4 (Pubitemid 40215561)
    • (2005) Applied Radiation and Isotopes , vol.62 , Issue.4 , pp. 631-634
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.N.3
  • 4
    • 0028840692 scopus 로고
    • DQE(f) of four generations of computed radiography acquisition devices
    • 10.1118/1.597627 0094-2405
    • Dobbins J T 3rd, Ergun D L, Rutz L, Hinshaw D A, Blume H and Clark D C 1995 DQE(f) of four generations of computed radiography acquisition devices Med. Phys. 22 1581-93
    • (1995) Med. Phys. , vol.22 , Issue.10 , pp. 1581-1593
    • Dobbins, J.T.1    Ergun, D.L.2    Rutz, L.3    Hinshaw, D.A.4    Blume, H.5    Clark, D.C.6
  • 5
    • 0141894318 scopus 로고    scopus 로고
    • Monte Carlo modeling of storage phosphor plate readouts
    • 10.1016/S0168-9002(03)02012-6 0168-9002 A
    • Fasbender R, Li H and Winnacker A 2003 Monte Carlo modeling of storage phosphor plate readouts Nucl. Instrum. Methods Phys. Res. A 512 610-8
    • (2003) Nucl. Instrum. Methods Phys. Res. , vol.512 , Issue.3 , pp. 610-618
    • Fasbender, R.1    Li, H.2    Winnacker, A.3
  • 8
    • 36749049838 scopus 로고    scopus 로고
    • Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements
    • DOI 10.1118/1.2804555
    • Jursinic P A 2007 Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements Med. Phys. 34 4594-604 (Pubitemid 350199438)
    • (2007) Medical Physics , vol.34 , Issue.12 , pp. 4594-4604
    • Jursinic, P.A.1
  • 11
    • 0033625293 scopus 로고    scopus 로고
    • A new needle-crystalline computed radiography detector
    • 10.1007/BF03167640 0897-1889
    • Leblans P, Struye L and Willems P 2000 A new needle-crystalline computed radiography detector J. Digit. Imaging 13 117-20
    • (2000) J. Digit. Imaging , vol.13 , Issue.S1 , pp. 117-120
    • Leblans, P.1    Struye, L.2    Willems, P.3
  • 13
    • 33845934654 scopus 로고    scopus 로고
    • 2+ storage phosphor plates exposed to megavoltage photon beams
    • DOI 10.1118/1.2400617
    • 2+ storage phosphor plates exposed to megavoltage photon beams Med. Phys. 34 103-11 (Pubitemid 46035232)
    • (2007) Medical Physics , vol.34 , Issue.1 , pp. 103-111
    • Li, H.H.1    Gonzalez, A.L.2    Ji, H.3    Duggan, D.M.4
  • 15
    • 25644457670 scopus 로고    scopus 로고
    • Evaluation of a computed radiography system for megavoltage photon beam dosimetry
    • DOI 10.1118/1.2012787
    • Olch A J 2005 Evaluation of a computed radiography system for megavoltage photon beam dosimetry Med. Phys. 32 2987-99 (Pubitemid 41384096)
    • (2005) Medical Physics , vol.32 , Issue.9 , pp. 2987-2999
    • Olch, A.J.1
  • 16
    • 0037038876 scopus 로고    scopus 로고
    • The physics of computed radiography
    • 0031-9155 201
    • Rowlands J A 2002 The physics of computed radiography Phys. Med. Biol. 47 R123-66
    • (2002) Phys. Med. Biol. , vol.47 , Issue.23
    • Rowlands, J.A.1
  • 17
    • 79959537535 scopus 로고    scopus 로고
    • Variations in photon energy spectra of a 6 MV beam and their impact on TLD response
    • 10.1118/1.3575419 0094-2405
    • Scarboro S B, Followill D S, Howell R M and Kry S F 2011 Variations in photon energy spectra of a 6 MV beam and their impact on TLD response Med. Phys. 38 2619-28
    • (2011) Med. Phys. , vol.38 , Issue.5 , pp. 2619-2628
    • Scarboro, S.B.1    Followill, D.S.2    Howell, R.M.3    Kry, S.F.4
  • 18
    • 34447299153 scopus 로고    scopus 로고
    • Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al2 O3:C) for film dosimetry in radiotherapy
    • DOI 10.1118/1.2737160
    • 3 :C) for film dosimetry in radiotherapy Med. Phys. 34 2113-8 (Pubitemid 47055746)
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 2113-2118
    • Schembri, V.1    Heijmen, B.J.M.2