메뉴 건너뛰기




Volumn 45, Issue 3-6, 2010, Pages 677-680

Demonstrating the use of optically stimulated luminescence dosimeters (OSLDs) for measurement of staff radiation exposure in interventional fluoroscopy and helmet output factors in radiosurgery

Author keywords

Gamma knife ; Interventional fluoroscopy; OSL; Output factor; Personal dosimetry

Indexed keywords

ANTHROPOMORPHIC PHANTOMS; GAMMA KNIFE; HIGH PRECISION; INTERVENTIONAL; LOW DOSE; OPTICALLY STIMULATED LUMINESCENCE DOSIMETERS; OSL; OUTPUT FACTORS; RADIATION EXPOSURE; RADIOSURGERY; SCATTERED RADIATIONS; SMALL FIELD SIZE;

EID: 77955309867     PISSN: 13504487     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radmeas.2009.12.001     Document Type: Conference Paper
Times cited : (13)

References (13)
  • 2
    • 0032910059 scopus 로고    scopus 로고
    • A radiation dosimetry method using pulsed optically stimulated luminescence
    • M.S. Akselrod, and S.W.S. McKeever A radiation dosimetry method using pulsed optically stimulated luminescence Radiation Protection Dosimetry 81 1999 167 176
    • (1999) Radiation Protection Dosimetry , vol.81 , pp. 167-176
    • Akselrod, M.S.1    McKeever, S.W.S.2
  • 3
    • 0035103742 scopus 로고    scopus 로고
    • A film technique for the determination of output factors and end effect times for the Leksell Gamma Knife
    • E.E. Ekstrand, and J.D. Bourland A film technique for the determination of output factors and end effect times for the Leksell Gamma Knife Physics in Medicine and Biology 46 2001 703 706
    • (2001) Physics in Medicine and Biology , vol.46 , pp. 703-706
    • Ekstrand, E.E.1    Bourland, J.D.2
  • 4
    • 33645220895 scopus 로고    scopus 로고
    • ICRU, International Commission on Radiation Units Protection ICRU Bethesda, MD
    • ICRU, International Commission on Radiation Units and Protection Patient Dosimetry for X Rays Used in Medical Imaging ICRU Report 74 2005 ICRU Bethesda, MD
    • (2005) Patient Dosimetry for X Rays Used in Medical Imaging
  • 7
    • 0029900838 scopus 로고    scopus 로고
    • Measured scattered X-ray energy spectra for simulated irradiation geometries in diagnostic radiology
    • N.W. Marshall, K. Faulkner, and H. Warren Measured scattered X-ray energy spectra for simulated irradiation geometries in diagnostic radiology Medical Physics 23 7 1996 1271 1276
    • (1996) Medical Physics , vol.23 , Issue.7 , pp. 1271-1276
    • Marshall, N.W.1    Faulkner, K.2    Warren, H.3
  • 8
    • 41049090061 scopus 로고    scopus 로고
    • Occupational radiation doses to operators performing cardiac catheterization procedures
    • D.L. Miller Occupational radiation doses to operators performing cardiac catheterization procedures Health Physics 94 3 2008 211 227
    • (2008) Health Physics , vol.94 , Issue.3 , pp. 211-227
    • Miller, D.L.1
  • 9
    • 0038247942 scopus 로고    scopus 로고
    • Determination of the 4 mm Gamma Knife helmet relative output factor using a variety of detectors
    • J. Tsai, M.J. Rivard, M.J. Engler, J.E. Mignano, and D.E. Wazer Determination of the 4 mm Gamma Knife helmet relative output factor using a variety of detectors Medical Physics 30 5 2003 986 992
    • (2003) Medical Physics , vol.30 , Issue.5 , pp. 986-992
    • Tsai, J.1    Rivard, M.J.2    Engler, M.J.3    Mignano, J.E.4    Wazer, D.E.5
  • 13
    • 37549059594 scopus 로고    scopus 로고
    • 3:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy
    • 3:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy Medical Physics 35 1 2008 260 269
    • (2008) Medical Physics , vol.35 , Issue.1 , pp. 260-269
    • Yukihara, E.G.1    Mardirossian, G.2    Mirzasadeghi, M.3    Guduru, S.4    Ahmad, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.