메뉴 건너뛰기




Volumn 106, Issue 12, 2017, Pages 995-1004

Comparison of outcomes using balloon-expandable versus self-expanding transcatheter prostheses according to the extent of aortic valve calcification

Author keywords

Aortic stenosis; Aortic valve calcification; MDCT; TAVI

Indexed keywords

ACUTE KIDNEY FAILURE; AGED; AORTIC REGURGITATION; AORTIC TRAUMA; AORTIC VALVE CALCIFICATION; AORTIC VALVE DISEASE; ARTERY CALCIFICATION; ARTICLE; BALLOON EXPANDABLE TRANSCATHETER AORTIC VALVE REPLACEMENT; CEREBROVASCULAR ACCIDENT; COMPARATIVE STUDY; DEVICE EMBOLIZATION; DEVICE FAILURE; FEMALE; HEMODYNAMICS; HUMAN; IMAGE ANALYSIS; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PACEMAKER IMPLANTATION; SELF EXPANDABLE TRANSCATHETER AORTIC VALVE REPLACEMENT; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSTHORACIC ECHOCARDIOGRAPHY; AORTIC VALVE; AORTIC VALVE STENOSIS; CALCINOSIS; DIAGNOSTIC IMAGING; HEART VALVE PROSTHESIS; PATHOLOGY; PROCEDURES; PROSTHESIS DESIGN; RETROSPECTIVE STUDY; TREATMENT OUTCOME; VERY ELDERLY;

EID: 85027145947     PISSN: 18610684     EISSN: 18610692     Source Type: Journal    
DOI: 10.1007/s00392-017-1149-3     Document Type: Article
Times cited : (41)

References (36)
  • 1
    • 84964932839 scopus 로고    scopus 로고
    • Transcatheter or surgical aortic-valve replacement in intermediate-risk patients
    • COI: 1:CAS:528:DC%2BC28XhtlOlurrN
    • Leon MB, Smith CR, Mack MJ et al (2016) Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. N Engl J Med 374(17):1609–1620. doi:10.1056/NEJMoa1514616
    • (2016) N Engl J Med , vol.374 , Issue.17 , pp. 1609-1620
    • Leon, M.B.1    Smith, C.R.2    Mack, M.J.3
  • 2
    • 84971320873 scopus 로고    scopus 로고
    • 2016 In-hospital outcome of transcatheter vs. surgical aortic valve replacement in patients with aortic valve stenosis: complete dataset of patients treated in 2013in Germany
    • Mollmann H, Bestehorn K, Bestehorn M et al (2016) 2016 In-hospital outcome of transcatheter vs. surgical aortic valve replacement in patients with aortic valve stenosis: complete dataset of patients treated in 2013in Germany. Clin Res Cardiol 105(6):553–559. doi:10.1007/s00392-016-0962-4
    • (2016) Clin Res Cardiol , vol.105 , Issue.6 , pp. 553-559
    • Mollmann, H.1    Bestehorn, K.2    Bestehorn, M.3
  • 3
    • 85017306295 scopus 로고    scopus 로고
    • Surgical or transcatheter aortic-valve replacement in intermediate-risk patients
    • Reardon MJ, Van Mieghem NM, Popma JJ et al (2017) Surgical or transcatheter aortic-valve replacement in intermediate-risk patients. N Engl J Med 376(14):1321–1331. doi:10.1056/NEJMoa1700456
    • (2017) N Engl J Med , vol.376 , Issue.14 , pp. 1321-1331
    • Reardon, M.J.1    Van Mieghem, N.M.2    Popma, J.J.3
  • 4
    • 84908264633 scopus 로고    scopus 로고
    • Extent and distribution of calcification of both the aortic annulus and the left ventricular outflow tract predict aortic regurgitation after transcatheter aortic valve replacement
    • Buellesfeld L, Stortecky S, Heg D et al (2014) Extent and distribution of calcification of both the aortic annulus and the left ventricular outflow tract predict aortic regurgitation after transcatheter aortic valve replacement. EuroIntervention 10(6):732–738. doi:10.4244/EIJV10I6A126
    • (2014) EuroIntervention , vol.10 , Issue.6 , pp. 732-738
    • Buellesfeld, L.1    Stortecky, S.2    Heg, D.3
  • 5
    • 84941733498 scopus 로고    scopus 로고
    • The impact of calcium volume and distribution in aortic root injury related to balloon-expandable transcatheter aortic valve replacement
    • Hansson NC, Norgaard BL, Barbanti M et al (2015) The impact of calcium volume and distribution in aortic root injury related to balloon-expandable transcatheter aortic valve replacement. J Cardiovasc Comput Tomogr 9(5):382–392. doi:10.1016/j.jcct.2015.04.002
    • (2015) J Cardiovasc Comput Tomogr , vol.9 , Issue.5 , pp. 382-392
    • Hansson, N.C.1    Norgaard, B.L.2    Barbanti, M.3
  • 6
    • 76649123667 scopus 로고    scopus 로고
    • Correlation of Device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis
    • John D, Buellesfeld L, Yuecel S et al (2010) Correlation of Device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis. JACC Cardiovasc Interv 3(2):233–243. doi:10.1016/j.jcin.2009.11.015
    • (2010) JACC Cardiovasc Interv , vol.3 , Issue.2 , pp. 233-243
    • John, D.1    Buellesfeld, L.2    Yuecel, S.3
  • 7
    • 84899645349 scopus 로고    scopus 로고
    • Aortic valve calcium score as a predictor for outcome after TAVI using the CoreValve revalving system
    • Leber AW, Kasel M, Ischinger T et al (2013) Aortic valve calcium score as a predictor for outcome after TAVI using the CoreValve revalving system. Int J Cardiol 166(3):652–657. doi:10.1016/j.ijcard.2011.11.091
    • (2013) Int J Cardiol , vol.166 , Issue.3 , pp. 652-657
    • Leber, A.W.1    Kasel, M.2    Ischinger, T.3
  • 8
    • 84979030736 scopus 로고    scopus 로고
    • Device landing zone calcification and its impact on residual regurgitation after transcatheter aortic valve implantation with different devices
    • Seiffert M, Fujita B, Avanesov M et al (2016) Device landing zone calcification and its impact on residual regurgitation after transcatheter aortic valve implantation with different devices. Eur Heart J Cardiovasc Imaging 17(5):576–584. doi:10.1093/ehjci/jev174
    • (2016) Eur Heart J Cardiovasc Imaging , vol.17 , Issue.5 , pp. 576-584
    • Seiffert, M.1    Fujita, B.2    Avanesov, M.3
  • 9
    • 84867283287 scopus 로고    scopus 로고
    • Guidelines on the management of valvular heart disease (version 2012)
    • Vahanian A, Alfieri O, Andreotti F et al (2012) Guidelines on the management of valvular heart disease (version 2012). Eur Heart J 33(19):2451–2496. doi:10.1093/eurheartj/ehs109
    • (2012) Eur Heart J , vol.33 , Issue.19 , pp. 2451-2496
    • Vahanian, A.1    Alfieri, O.2    Andreotti, F.3
  • 10
    • 84959562001 scopus 로고    scopus 로고
    • Transfemoral aortic valve implantation of Edwards SAPIEN 3 without predilatation
    • Kim WK, Praz F, Blumenstein J et al (2016) Transfemoral aortic valve implantation of Edwards SAPIEN 3 without predilatation. Catheter Cardiovasc Interv. doi:10.1002/ccd.26464
    • (2016) Catheter Cardiovasc Interv
    • Kim, W.K.1    Praz, F.2    Blumenstein, J.3
  • 11
    • 84913611311 scopus 로고    scopus 로고
    • Transfemoral aortic valve implantation of Edwards SAPIEN XT without predilatation is feasible
    • Mollmann H, Kim WK, Kempfert J et al (2014) Transfemoral aortic valve implantation of Edwards SAPIEN XT without predilatation is feasible. Clin Cardiol 37(11):667–671. doi:10.1002/clc.22318
    • (2014) Clin Cardiol , vol.37 , Issue.11 , pp. 667-671
    • Mollmann, H.1    Kim, W.K.2    Kempfert, J.3
  • 12
    • 85020121879 scopus 로고    scopus 로고
    • Transfemoral aortic valve implantation using a self-expanding transcatheter heart valve without pre-dilation
    • Kim WK, Liebetrau C, Renker M et al (2017) Transfemoral aortic valve implantation using a self-expanding transcatheter heart valve without pre-dilation. Int J Cardiol. doi:10.1016/j.ijcard.2017.05.092
    • (2017) Int J Cardiol
    • Kim, W.K.1    Liebetrau, C.2    Renker, M.3
  • 13
    • 84898754246 scopus 로고    scopus 로고
    • First-in-human experience with the Medtronic CoreValve Evolut R
    • Piazza N, Martucci G, Lachapelle K et al (2014) First-in-human experience with the Medtronic CoreValve Evolut R. EuroIntervention 9(11):1260–1263. doi:10.4244/EIJV9I11A215
    • (2014) EuroIntervention , vol.9 , Issue.11 , pp. 1260-1263
    • Piazza, N.1    Martucci, G.2    Lachapelle, K.3
  • 15
    • 84929952488 scopus 로고    scopus 로고
    • Diagnostic accuracy of computed tomography angiography for the detection of coronary artery disease in patients referred for transcatheter aortic valve implantation
    • Opolski MP, Kim WK, Liebetrau C et al (2015) Diagnostic accuracy of computed tomography angiography for the detection of coronary artery disease in patients referred for transcatheter aortic valve implantation. Clin Res Cardiol 104(6):471–480. doi:10.1007/s00392-014-0806-z
    • (2015) Clin Res Cardiol , vol.104 , Issue.6 , pp. 471-480
    • Opolski, M.P.1    Kim, W.K.2    Liebetrau, C.3
  • 16
    • 84958759309 scopus 로고    scopus 로고
    • Cyclic changes in area- and perimeter-derived effective dimensions of the aortic annulus measured with multislice computed tomography and comparison with metric intraoperative sizing
    • Kim WK, Meyer A, Mollmann H et al (2016) Cyclic changes in area- and perimeter-derived effective dimensions of the aortic annulus measured with multislice computed tomography and comparison with metric intraoperative sizing. Clin Res Cardiol 105(7):622–629. doi:10.1007/s00392-016-0971-3
    • (2016) Clin Res Cardiol , vol.105 , Issue.7 , pp. 622-629
    • Kim, W.K.1    Meyer, A.2    Mollmann, H.3
  • 17
    • 84908022512 scopus 로고    scopus 로고
    • Impact of aortic valve calcification, as measured by MDCT, on survival in patients with aortic stenosis: results of an international registry study
    • Clavel MA, Pibarot P, Messika-Zeitoun D et al (2014) Impact of aortic valve calcification, as measured by MDCT, on survival in patients with aortic stenosis: results of an international registry study. J Am Coll Cardiol 64(12):1202–1213. doi:10.1016/j.jacc.2014.05.066
    • (2014) J Am Coll Cardiol , vol.64 , Issue.12 , pp. 1202-1213
    • Clavel, M.A.1    Pibarot, P.2    Messika-Zeitoun, D.3
  • 18
    • 80052051390 scopus 로고    scopus 로고
    • EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease
    • Zamorano JL, Badano LP, Bruce C et al (2011) EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease. J Am Soc Echocardiogr 24(9):937–965. doi:10.1016/j.echo.2011.07.003
    • (2011) J Am Soc Echocardiogr , vol.24 , Issue.9 , pp. 937-965
    • Zamorano, J.L.1    Badano, L.P.2    Bruce, C.3
  • 19
    • 84875975723 scopus 로고    scopus 로고
    • Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature
    • Athappan G, Patvardhan E, Tuzcu EM et al (2013) Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol 61(15):1585–1595. doi:10.1016/j.jacc.2013.01.047
    • (2013) J Am Coll Cardiol , vol.61 , Issue.15 , pp. 1585-1595
    • Athappan, G.1    Patvardhan, E.2    Tuzcu, E.M.3
  • 20
    • 84898644090 scopus 로고    scopus 로고
    • Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial
    • Abdel-Wahab M, Mehilli J, Frerker C et al (2014) Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial. JAMA 311(15):1503–1514. doi:10.1001/jama.2014.3316
    • (2014) JAMA , vol.311 , Issue.15 , pp. 1503-1514
    • Abdel-Wahab, M.1    Mehilli, J.2    Frerker, C.3
  • 21
    • 84925272749 scopus 로고    scopus 로고
    • A revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation
    • Jilaihawi H, Makkar RR, Kashif M et al (2014) A revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging 15(12):1324–1332. doi:10.1093/ehjci/jeu162
    • (2014) Eur Heart J Cardiovasc Imaging , vol.15 , Issue.12 , pp. 1324-1332
    • Jilaihawi, H.1    Makkar, R.R.2    Kashif, M.3
  • 22
    • 84860466759 scopus 로고    scopus 로고
    • Two-year outcomes after transcatheter or surgical aortic-valve replacement
    • COI: 1:CAS:528:DC%2BC38XmsFymsL8%3D
    • Kodali SK, Williams MR, Smith CR et al (2012) Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med 366(18):1686–1695. doi:10.1056/NEJMoa1200384
    • (2012) N Engl J Med , vol.366 , Issue.18 , pp. 1686-1695
    • Kodali, S.K.1    Williams, M.R.2    Smith, C.R.3
  • 23
    • 80255137247 scopus 로고    scopus 로고
    • Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the U.K. TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry
    • Moat NE, Ludman P, de Belder MA et al (2011) Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the U.K. TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry. J Am Coll Cardiol 58(20):2130–2138. doi:10.1016/j.jacc.2011.08.050
    • (2011) J Am Coll Cardiol , vol.58 , Issue.20 , pp. 2130-2138
    • Moat, N.E.1    Ludman, P.2    de Belder, M.A.3
  • 24
    • 85003056152 scopus 로고    scopus 로고
    • Prosthesis-specific predictors of paravalvular regurgitation after transcatheter aortic valve replacement: impact of calcification and sizing on balloon-expandable versus self-expandable transcatheter heart valves
    • Stahli BE, Nguyen-Kim TD, Gebhard C et al (2015) Prosthesis-specific predictors of paravalvular regurgitation after transcatheter aortic valve replacement: impact of calcification and sizing on balloon-expandable versus self-expandable transcatheter heart valves. J Heart Valve Dis 24(1):10–21
    • (2015) J Heart Valve Dis , vol.24 , Issue.1 , pp. 10-21
    • Stahli, B.E.1    Nguyen-Kim, T.D.2    Gebhard, C.3
  • 25
    • 84959917059 scopus 로고    scopus 로고
    • Aortic valve calcium score for paravalvular aortic insufficiency (AVCS II) study in transapical aortic valve implantation
    • Haensig M, Lehmkuhl L, Linke A et al (2016) Aortic valve calcium score for paravalvular aortic insufficiency (AVCS II) study in transapical aortic valve implantation. Heart Surg Forum 19(1):E036–E042. doi:10.1532/hsf.1399
    • (2016) Heart Surg Forum , vol.19 , Issue.1 , pp. E036-E042
    • Haensig, M.1    Lehmkuhl, L.2    Linke, A.3
  • 26
    • 79958178970 scopus 로고    scopus 로고
    • Association of aortic valve calcification severity wiAssociation of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation
    • Koos R, Mahnken AH, Dohmen G et al (2011) Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation. Int J Cardiol 150(2):142–145. doi:10.1016/j.ijcard.2010.03.004
    • (2011) Int J Cardiol , vol.150 , Issue.2 , pp. 142-145
    • Koos, R.1    Mahnken, A.H.2    Dohmen, G.3
  • 27
    • 84865373763 scopus 로고    scopus 로고
    • Aortic valve calcium scoring is a predictor of significant paravalvular aortic insufficiency in transapical-aortic valve implantation
    • (discussion 1240–1231)
    • Haensig M, Lehmkuhl L, Rastan AJ et al (2012) Aortic valve calcium scoring is a predictor of significant paravalvular aortic insufficiency in transapical-aortic valve implantation. Eur J Cardiothorac Surg 41(6):1234–1240. doi:10.1093/ejcts/ezr244 (discussion 1240–1231)
    • (2012) Eur J Cardiothorac Surg , vol.41 , Issue.6 , pp. 1234-1240
    • Haensig, M.1    Lehmkuhl, L.2    Rastan, A.J.3
  • 28
    • 84906334554 scopus 로고    scopus 로고
    • Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement
    • Khalique OK, Hahn RT, Gada H et al (2014) Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement. JACC Cardiovasc Interv 7(8):885–894. doi:10.1016/j.jcin.2014.03.007
    • (2014) JACC Cardiovasc Interv , vol.7 , Issue.8 , pp. 885-894
    • Khalique, O.K.1    Hahn, R.T.2    Gada, H.3
  • 29
    • 80055107711 scopus 로고    scopus 로고
    • Aortic annulus dimensions and leaflet calcification from contrast MSCT predict the need for balloon post-dilatation after TAVI with the Medtronic CoreValve prosthesis
    • Schultz C, Rossi A, van Mieghem N et al (2011) Aortic annulus dimensions and leaflet calcification from contrast MSCT predict the need for balloon post-dilatation after TAVI with the Medtronic CoreValve prosthesis. EuroIntervention 7(5):564–572. doi:10.4244/EIJV7I5A92
    • (2011) EuroIntervention , vol.7 , Issue.5 , pp. 564-572
    • Schultz, C.1    Rossi, A.2    van Mieghem, N.3
  • 30
    • 84908133958 scopus 로고    scopus 로고
    • Impact of balloon post-dilation on clinical outcomes after transcatheter aortic valve replacement with the self-expanding CoreValve prosthesis
    • Barbanti M, Petronio AS, Capodanno D et al (2014) Impact of balloon post-dilation on clinical outcomes after transcatheter aortic valve replacement with the self-expanding CoreValve prosthesis. JACC Cardiovasc Interv 7(9):1014–1021. doi:10.1016/j.jcin.2014.03.009
    • (2014) JACC Cardiovasc Interv , vol.7 , Issue.9 , pp. 1014-1021
    • Barbanti, M.1    Petronio, A.S.2    Capodanno, D.3
  • 31
    • 84880355851 scopus 로고    scopus 로고
    • Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement
    • Barbanti M, Yang TH, Rodes Cabau J et al (2013) Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation 128(3):244–253. doi:10.1161/CIRCULATIONAHA.113.002947
    • (2013) Circulation , vol.128 , Issue.3 , pp. 244-253
    • Barbanti, M.1    Yang, T.H.2    Rodes Cabau, J.3
  • 32
    • 84939492199 scopus 로고    scopus 로고
    • 1-year outcomes after transcatheter aortic valve replacement with balloon-expandable versus self-expandable valves: results from the CHOICE Randomized Clinical Trial
    • Abdel-Wahab M, Neumann FJ, Mehilli J et al (2015) 1-year outcomes after transcatheter aortic valve replacement with balloon-expandable versus self-expandable valves: results from the CHOICE Randomized Clinical Trial. J Am Coll Cardiol 66(7):791–800. doi:10.1016/j.jacc.2015.06.026
    • (2015) J Am Coll Cardiol , vol.66 , Issue.7 , pp. 791-800
    • Abdel-Wahab, M.1    Neumann, F.J.2    Mehilli, J.3
  • 33
    • 84964273473 scopus 로고    scopus 로고
    • Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve
    • Webb J, Gerosa G, Lefevre T et al (2014) Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve. J Am Coll Cardiol 64(21):2235–2243. doi:10.1016/j.jacc.2014.09.026
    • (2014) J Am Coll Cardiol , vol.64 , Issue.21 , pp. 2235-2243
    • Webb, J.1    Gerosa, G.2    Lefevre, T.3
  • 34
    • 85009279306 scopus 로고    scopus 로고
    • Trends in aortic valve replacement in Germany in 2015: transcatheter versus isolated surgical aortic valve repair
    • Gaede L, Blumenstein J, Kim WK et al (2017) Trends in aortic valve replacement in Germany in 2015: transcatheter versus isolated surgical aortic valve repair. Clin Res Cardiol 106(6):411–419. doi:10.1007/s00392-016-1070-1
    • (2017) Clin Res Cardiol , vol.106 , Issue.6 , pp. 411-419
    • Gaede, L.1    Blumenstein, J.2    Kim, W.K.3
  • 35
    • 80052778092 scopus 로고    scopus 로고
    • Transapical aortic valve implantation: analysis of risk factors and learning experience in 299 patients
    • Kempfert J, Rastan A, Holzhey D et al (2011) Transapical aortic valve implantation: analysis of risk factors and learning experience in 299 patients. Circulation 124(11 Suppl):S124–S129. doi:10.1161/CIRCULATIONAHA.110.013425
    • (2011) Circulation , vol.124 , pp. S124-S129
    • Kempfert, J.1    Rastan, A.2    Holzhey, D.3
  • 36
    • 85020200148 scopus 로고    scopus 로고
    • Transcathether aortic valve implantation with the new repositionable self-expandable Evolut R versus CoreValve system: a case-matched comparison
    • Giannini C, De Carlo M, Tamburino C et al (2017) Transcathether aortic valve implantation with the new repositionable self-expandable Evolut R versus CoreValve system: a case-matched comparison. Int J Cardiol. doi:10.1016/j.ijcard.2017.05.095
    • (2017) Int J Cardiol
    • Giannini, C.1    De Carlo, M.2    Tamburino, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.