메뉴 건너뛰기




Volumn 10, Issue 6, 2014, Pages 732-738

Extent and distribution of calcification of both the aortic annulus and the left ventricular outflow tract predict aortic regurgitation after transcatheter aortic valve replacement

Author keywords

Aortic annulus; Calcification; Outflow tract; Transcatheter aortic valve replacement

Indexed keywords

AGED; AORTA ROOT; AORTA STENOSIS; AORTA VALVE REGURGITATION; AORTIC ANNULUS CALCIFICATION; ARTERY CALCIFICATION; ARTICLE; CARDIOVASCULAR MORTALITY; CARDIOVASCULAR PARAMETERS; COMPUTED TOMOGRAPHY SCANNER; CONTROLLED STUDY; CORONARY ARTERY; DISEASE SEVERITY; FEMALE; HEART LEFT VENTRICLE OUTFLOW TRACT OBSTRUCTION; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; IMPLANTATION; LEFT CORONARY CUSP; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; MULTIVARIATE LOGISTIC REGRESSION ANALYSIS; POSTOPERATIVE COMPLICATION; PREDICTION; QUANTITATIVE ANALYSIS; RIGHT CORONARY CUSP; SELF EXPANDING STENT; TRANSCATHETER AORTIC VALVE IMPLANTATION; VERY ELDERLY;

EID: 84908264633     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV10I6A126     Document Type: Article
Times cited : (60)

References (19)
  • 7
    • 76649123667 scopus 로고    scopus 로고
    • Correlation of Device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis
    • John D, Buellesfeld L, Yuecel S, Mueller R, Latsios G, Beucher H, Gerckens U, Grube E. Correlation of Device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis. JACC Cardiovasc Interv. 2010;3:233-43.
    • (2010) JACC Cardiovasc Interv , vol.3 , pp. 233-243
    • John, D.1    Buellesfeld, L.2    Yuecel, S.3    Mueller, R.4    Latsios, G.5    Beucher, H.6    Gerckens, U.7    Grube, E.8
  • 9
    • 79958178970 scopus 로고    scopus 로고
    • Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation
    • Koos R, Mahnken AH, Dohmen G, Brehmer K, Günther RW, Autschbach R, Marx N, Hoffmann R. Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation. Int J Cardiol. 2011;150:142-5.
    • (2011) Int J Cardiol , vol.150 , pp. 142-145
    • Koos, R.1    Mahnken, A.H.2    Dohmen, G.3    Brehmer, K.4    Günther, R.W.5    Autschbach, R.6    Marx, N.7    Hoffmann, R.8
  • 14
    • 31044444136 scopus 로고    scopus 로고
    • Reproducibility of CT measurements of aortic valve calcification, mitral annulus calcification, and aortic wall calcification in the multi-ethnic study of atherosclerosis
    • Budoff MJ, Takasu J, Katz R, Mao S, Shavelle DM, O'Brien KD, Blumenthal RS, Carr JJ, Kronmal R. Reproducibility of CT measurements of aortic valve calcification, mitral annulus calcification, and aortic wall calcification in the multi-ethnic study of atherosclerosis. Acad Radiol. 2006;13:166-72.
    • (2006) Acad Radiol , vol.13 , pp. 166-172
    • Budoff, M.J.1    Takasu, J.2    Katz, R.3    Mao, S.4    Shavelle, D.M.5    O'brien, K.D.6    Blumenthal, R.S.7    Carr, J.J.8    Kronmal, R.9
  • 19
    • 84901190926 scopus 로고    scopus 로고
    • Dynamic characterization of aortic annulus geometry and morphology with multimodality imaging: Predictive value for aortic regurgitation after transcatheter aortic valve replacement
    • Masri A, Schoenhagen P, Svensson L, Kapadia SR, Griffin BP, Tuzcu EM, Desai MY. Dynamic characterization of aortic annulus geometry and morphology with multimodality imaging: predictive value for aortic regurgitation after transcatheter aortic valve replacement. J Thorac Cardiovasc Surg. 2014;147:1847-54.
    • (2014) J Thorac Cardiovasc Surg , vol.147 , pp. 1847-1854
    • Masri, A.1    Schoenhagen, P.2    Svensson, L.3    Kapadia, S.R.4    Griffin, B.P.5    Tuzcu, E.M.6    Desai, M.Y.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.