Volumn 66, Issue 7, 2015, Pages 791-800

1-year outcomes after transcatheter aortic valve replacement with balloon-expandable versus self-expandable valves: Results from the CHOICE randomized clinical trial

Author keywords

aortic stenosis; balloon expandable; self expandable; TAVR

Indexed keywords

AGED; ANTICOAGULANT THERAPY; AORTA STENOSIS; ARTICLE; BALLOON EXPANDABLE TRANSCATHETER AORTIC VALVE; CARDIOVASCULAR MORTALITY; CARDIOVASCULAR PARAMETERS; CEREBROVASCULAR ACCIDENT; CLINICAL ASSESSMENT; CONTROLLED STUDY; DISEASE SEVERITY; ECHOCARDIOGRAPHY; FEMALE; FOLLOW UP; HEART FAILURE; HIGH RISK PATIENT; HOSPITAL READMISSION; HUMAN; MAJOR CLINICAL STUDY; MALE; MITRAL VALVE REGURGITATION; OUTCOME ASSESSMENT; PERCUTANEOUS AORTIC VALVE; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; SELF EXPANDABLE TRANSCATHETER AORTIC VALVE; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSVALVULAR GRADIENT; VERY ELDERLY; AORTIC VALVE STENOSIS; CLINICAL TRIAL; COMPARATIVE STUDY; HEART VALVE PROSTHESIS; MIDDLE AGED; MULTICENTER STUDY; PROSPECTIVE STUDY; PROSTHESIS; STANDARDS; TIME; TRANSLUMINAL VALVULOPLASTY; TREATMENT OUTCOME; TRENDS;

EID: 84939492199     PISSN: 07351097     EISSN: 15583597     Source Type: Journal    
DOI: 10.1016/j.jacc.2015.06.026     Document Type: Article
Times cited : (137)

References (24)
  • 1
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • M.B. Leon, C.R. Smith, M. Mack, et al. for the PARTNER Trial Investigators Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery N Engl J Med 363 2010 1597 1607
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    MacK, M.3
  • 2
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • C.R. Smith, M.B. Leon, M.J. Mack, et al. for the PARTNER Trial Investigators Transcatheter versus surgical aortic-valve replacement in high-risk patients N Engl J Med 364 2011 2187 2198
    • (2011) N Engl J Med , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    MacK, M.J.3
  • 3
    • 84899811656 scopus 로고    scopus 로고
    • Transcatheter aortic-valve replacement with a self-expanding prosthesis
    • D.H. Adams, J.J. Popma, M.J. Reardon, et al. for the U.S. CoreValve Clinical Investigators Transcatheter aortic-valve replacement with a self-expanding prosthesis N Engl J Med 370 2014 1790 1798
    • (2014) N Engl J Med , vol.370 , pp. 1790-1798
    • Adams, D.H.1    Popma, J.J.2    Reardon, M.J.3
  • 4
    • 84899826816 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery
    • J.J. Popma, D.H. Adams, M.J. Reardon, et al. for the CoreValve United States Clinical Investigators Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery J Am Coll Cardiol 63 2014 1972 1981
    • (2014) J Am Coll Cardiol , vol.63 , pp. 1972-1981
    • Popma, J.J.1    Adams, D.H.2    Reardon, M.J.3
  • 5
    • 84907028583 scopus 로고    scopus 로고
    • Treatment of aortic stenosis with a self-expanding transcatheter valve: The international multi-centre ADVANCE study
    • A. Linke, P. Wenaweser, U. Gerckens, et al. for the ADVANCE Study Investigators Treatment of aortic stenosis with a self-expanding transcatheter valve: the international multi-centre ADVANCE study Eur Heart J 35 2014 2672 2684
    • (2014) Eur Heart J , vol.35 , pp. 2672-2684
    • Linke, A.1    Wenaweser, P.2    Gerckens, U.3
  • 6
    • 84931566497 scopus 로고    scopus 로고
    • 5-Year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): A randomised controlled trial
    • M.J. Mack, M.B. Leon, C.R. Smith, et al. for the PARTNER 1 Trial Investigators 5-Year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): a randomised controlled trial Lancet 385 2015 2477 2484
    • (2015) Lancet , vol.385 , pp. 2477-2484
    • MacK, M.J.1    Leon, M.B.2    Smith, C.R.3
  • 7
    • 84929340631 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation in the United Kingdom: Temporal trends, predictors of outcome, and 6-year follow-up: A report from the UK Transcatheter Aortic Valve Implantation (TAVI) Registry 2007 to 2012
    • P.F. Ludman, N. Moat, M.A. de Belder, et al. for the UK TAVI Steering Committee and the National Institute for Cardiovascular Outcomes Research Transcatheter aortic valve implantation in the United Kingdom: temporal trends, predictors of outcome, and 6-year follow-up: a report from the UK Transcatheter Aortic Valve Implantation (TAVI) Registry 2007 to 2012 Circulation 131 2015 1181 1190
    • (2015) Circulation , vol.131 , pp. 1181-1190
    • Ludman, P.F.1    Moat, N.2    De Belder, M.A.3
  • 8
    • 84875213125 scopus 로고    scopus 로고
    • Comparison of hemodynamic performance of self-expandable CoreValve versus balloon-expandable Edwards SAPIEN aortic valves inserted by catheter for aortic stenosis
    • L. Nombela-Franco, M. Ruel, S. Radhakrishnan, and et al. Comparison of hemodynamic performance of self-expandable CoreValve versus balloon-expandable Edwards SAPIEN aortic valves inserted by catheter for aortic stenosis Am J Cardiol 111 2013 1026 1033
    • (2013) Am J Cardiol , vol.111 , pp. 1026-1033
    • Nombela-Franco, L.1    Ruel, M.2    Radhakrishnan, S.3
  • 9
    • 84896509829 scopus 로고    scopus 로고
    • Aortic regurgitation after transcatheter aortic valve implantation with balloon- and self-expandable prostheses: A pooled analysis from a 2-center experience
    • M. Abdel-Wahab, T. Comberg, H.J. Büttner, et al. for the Segeberg-Krozingen TAVI Registry Aortic regurgitation after transcatheter aortic valve implantation with balloon- and self-expandable prostheses: a pooled analysis from a 2-center experience J Am Coll Cardiol Intv 7 2014 284 292
    • (2014) J Am Coll Cardiol Intv , vol.7 , pp. 284-292
    • Abdel-Wahab, M.1    Comberg, T.2    Büttner, H.J.3
  • 10
    • 84874530713 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation with the Edwards SAPIEN versus the Medtronic CoreValve Revalving system devices: A multicenter collaborative study: The PRAGMATIC Plus initiative (Pooled-RotterdAm-Milano-Toulouse in Collaboration)
    • A. Chieffo, G.L. Buchanan, N.M. Van Mieghem, and et al. Transcatheter aortic valve implantation with the Edwards SAPIEN versus the Medtronic CoreValve Revalving system devices: a multicenter collaborative study: the PRAGMATIC Plus initiative (Pooled-RotterdAm-Milano-Toulouse In Collaboration) J Am Coll Cardiol 61 2013 830 836
    • (2013) J Am Coll Cardiol , vol.61 , pp. 830-836
    • Chieffo, A.1    Buchanan, G.L.2    Van Mieghem, N.M.3
  • 11
    • 84898056725 scopus 로고    scopus 로고
    • Postprocedural aortic regurgitation in balloon-expandable and self-expandable transcatheter aortic valve replacement procedures: Analysis of predictors and impact on long-term mortality: Insights from the FRANCE2 Registry
    • E. Van Belle, F. Juthier, S. Susen, et al. for the FRANCE 2 Investigators Postprocedural aortic regurgitation in balloon-expandable and self-expandable transcatheter aortic valve replacement procedures: analysis of predictors and impact on long-term mortality: insights from the FRANCE2 Registry Circulation 129 2014 1415 1427
    • (2014) Circulation , vol.129 , pp. 1415-1427
    • Van Belle, E.1    Juthier, F.2    Susen, S.3
  • 12
    • 84898644090 scopus 로고    scopus 로고
    • Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: The CHOICE randomized clinical trial
    • M. Abdel-Wahab, J. Mehilli, C. Frerker, et al. for the CHOICE investigators Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial JAMA 311 2014 1503 1514
    • (2014) JAMA , vol.311 , pp. 1503-1514
    • Abdel-Wahab, M.1    Mehilli, J.2    Frerker, C.3
  • 13
    • 34250815116 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: Device success and 30-day clinical outcome
    • E. Grube, G. Schuler, L. Buellesfeld, and et al. Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome J Am Coll Cardiol 50 2007 69 76
    • (2007) J Am Coll Cardiol , vol.50 , pp. 69-76
    • Grube, E.1    Schuler, G.2    Buellesfeld, L.3
  • 14
    • 67649532220 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Impact on clinical and valve-related outcomes
    • J.G. Webb, L. Altwegg, R.H. Boone, and et al. Transcatheter aortic valve implantation: impact on clinical and valve-related outcomes Circulation 119 2009 3009 3016
    • (2009) Circulation , vol.119 , pp. 3009-3016
    • Webb, J.G.1    Altwegg, L.2    Boone, R.H.3
  • 15
    • 78651489907 scopus 로고    scopus 로고
    • Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: A consensus report from the Valve Academic Research Consortium
    • M.B. Leon, N. Piazza, E. Nikolsky, and et al. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium Eur Heart J 32 2011 205 217
    • (2011) Eur Heart J , vol.32 , pp. 205-217
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3
  • 16
    • 69549087044 scopus 로고    scopus 로고
    • Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound
    • W.A. Zoghbi, J.B. Chambers, J.G. Dumesnil, and et al. Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound J Am Soc Echocardiogr 22 2009 975 1014
    • (2009) J Am Soc Echocardiogr , vol.22 , pp. 975-1014
    • Zoghbi, W.A.1    Chambers, J.B.2    Dumesnil, J.G.3
  • 18
    • 84860466759 scopus 로고    scopus 로고
    • Two-year outcomes after transcatheter or surgical aortic-valve replacement
    • S.K. Kodali, M.R. Williams, C.R. Smith, et al. for the PARTNER Trial Investigators Two-year outcomes after transcatheter or surgical aortic-valve replacement N Engl J Med 366 2012 1686 1695
    • (2012) N Engl J Med , vol.366 , pp. 1686-1695
    • Kodali, S.K.1    Williams, M.R.2    Smith, C.R.3
  • 19
    • 84873742898 scopus 로고    scopus 로고
    • Reversible Edwards SAPIEN XT dysfunction due to prosthesis thrombosis presenting as early structural deterioration
    • A. Latib, D. Messika-Zeitoun, F. Maisano, and et al. Reversible Edwards SAPIEN XT dysfunction due to prosthesis thrombosis presenting as early structural deterioration J Am Coll Cardiol 61 2013 787 789
    • (2013) J Am Coll Cardiol , vol.61 , pp. 787-789
    • Latib, A.1    Messika-Zeitoun, D.2    Maisano, F.3
  • 20
    • 84923568380 scopus 로고    scopus 로고
    • Valve thrombosis following transcatheter aortic valve implantation: A systematic review
    • J.G. Córdoba-Soriano, R. Puri, I. Amat-Santos, and et al. Valve thrombosis following transcatheter aortic valve implantation: a systematic review Rev Esp Cardiol (Engl Ed) 68 2015 198 204
    • (2015) Rev Esp Cardiol (Engl Ed) , vol.68 , pp. 198-204
    • Córdoba-Soriano, J.G.1    Puri, R.2    Amat-Santos, I.3
  • 21
    • 84892723273 scopus 로고    scopus 로고
    • Hemodynamics in the Valsalva sinuses after transcatheter aortic valve implantation (TAVI)
    • A. Ducci, S. Tzamtzis, M.J. Mullen, and G. Burriesci Hemodynamics in the Valsalva sinuses after transcatheter aortic valve implantation (TAVI) J Heart Valve Dis 22 2013 688 696
    • (2013) J Heart Valve Dis , vol.22 , pp. 688-696
    • Ducci, A.1    Tzamtzis, S.2    Mullen, M.J.3    Burriesci, G.4
  • 22
    • 84924350693 scopus 로고    scopus 로고
    • Clinical outcomes at 1 year following transcatheter aortic valve replacement
    • D.R. Holmes Jr., J.M. Brennan, J.S. Rumsfeld, et al. for the STS/ACC TVT Registry Clinical outcomes at 1 year following transcatheter aortic valve replacement JAMA 313 2015 1019 1028
    • (2015) JAMA , vol.313 , pp. 1019-1028
    • Holmes, Jr.D.R.1    Brennan, J.M.2    Rumsfeld, J.S.3
  • 23
    • 84901048870 scopus 로고    scopus 로고
    • Influence of transcatheter aortic valve replacement strategy and valve design on stroke after transcatheter aortic valve replacement: A meta-analysis and systematic review of literature
    • G. Athappan, R.D. Gajulapalli, P. Sengodan, and et al. Influence of transcatheter aortic valve replacement strategy and valve design on stroke after transcatheter aortic valve replacement: a meta-analysis and systematic review of literature J Am Coll Cardiol 63 2014 2101 2110
    • (2014) J Am Coll Cardiol , vol.63 , pp. 2101-2110
    • Athappan, G.1    Gajulapalli, R.D.2    Sengodan, P.3
  • 24
    • 84926214214 scopus 로고    scopus 로고
    • Assessment of paravalvular aortic regurgitation after transcatheter aortic valve replacement: Intra-core laboratory variability
    • R.T. Hahn, P. Pibarot, N.J. Weissman, L. Rodriguez, and W.A. Jaber Assessment of paravalvular aortic regurgitation after transcatheter aortic valve replacement: intra-core laboratory variability J Am Soc Echocardiogr 28 2015 415 422
    • (2015) J Am Soc Echocardiogr , vol.28 , pp. 415-422
    • Hahn, R.T.1    Pibarot, P.2    Weissman, N.J.3    Rodriguez, L.4    Jaber, W.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.