메뉴 건너뛰기




Volumn 64, Issue 21, 2014, Pages 2235-2243

Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve

Author keywords

aortic stenosis; transcatheter aortic valve replacement

Indexed keywords

AGED; AORTA STENOSIS; AORTA VALVE PROSTHESIS; ARTICLE; CLINICAL TRIAL; COMORBIDITY; DISEASE SEVERITY; ECHOCARDIOGRAPHY; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MITRAL VALVE REGURGITATION; MORTALITY; MULTICENTER STUDY; PROSPECTIVE STUDY; SURGICAL RISK; TRANSCATHETER AORTIC VALVE IMPLANTATION; TREATMENT OUTCOME;

EID: 84964273473     PISSN: 07351097     EISSN: 15583597     Source Type: Journal    
DOI: 10.1016/j.jacc.2014.09.026     Document Type: Article
Times cited : (279)

References (22)
  • 1
    • 84880591192 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement with SAPIEN 3: A new balloon expandable transcatheter heart valve
    • R.K. Binder, J. Rodés-Cabau, and D.A. Wood Transcatheter aortic valve replacement with SAPIEN 3: a new balloon expandable transcatheter heart valve J Am Coll Cardiol Intv 6 2013 293 300
    • (2013) J Am Coll Cardiol Intv , vol.6 , pp. 293-300
    • Binder, R.K.1    Rodés-Cabau, J.2    Wood, D.A.3
  • 2
    • 84872143850 scopus 로고    scopus 로고
    • Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document
    • A.P. Kappetein, S.J. Head, and P. Genereux Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document EuroIntervention 8 2012 782 795
    • (2012) EuroIntervention , vol.8 , pp. 782-795
    • Kappetein, A.P.1    Head, S.J.2    Genereux, P.3
  • 3
    • 69549087044 scopus 로고    scopus 로고
    • Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound: A report from the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves
    • W. Zoghbi, J. Chambers, and J. Dumesnil Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves J Am Soc Echocardiogr 22 2009 975 1014
    • (2009) J Am Soc Echocardiogr , vol.22 , pp. 975-1014
    • Zoghbi, W.1    Chambers, J.2    Dumesnil, J.3
  • 4
    • 84870743337 scopus 로고    scopus 로고
    • SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR)
    • S. Achenbach, V. Delgado, J. Hausleiter, P. Schoenhagen, J. Min, and J. Leipsic SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR) J Cardiovasc Comput Tomogr 6 2012 366 380
    • (2012) J Cardiovasc Comput Tomogr , vol.6 , pp. 366-380
    • Achenbach, S.1    Delgado, V.2    Hausleiter, J.3    Schoenhagen, P.4    Min, J.5    Leipsic, J.6
  • 5
    • 84880355851 scopus 로고    scopus 로고
    • Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement
    • M. Barbanti, T.H. Yang, and J. Rodés Cabau Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement Circulation 128 2013 244 253
    • (2013) Circulation , vol.128 , pp. 244-253
    • Barbanti, M.1    Yang, T.H.2    Rodés Cabau, J.3
  • 6
    • 84880614039 scopus 로고    scopus 로고
    • The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: A prospective, multicenter, controlled trial
    • R.K. Binder, J.G. Webb, and A.B. Willson The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial J Am Coll Cardiol 62 2013 431 438
    • (2013) J Am Coll Cardiol , vol.62 , pp. 431-438
    • Binder, R.K.1    Webb, J.G.2    Willson, A.B.3
  • 7
    • 33644860328 scopus 로고    scopus 로고
    • Percutaneous aortic valve implantation retrograde from the femoral artery
    • J.G. Webb, M. Chandavimol, and C. Thompson Percutaneous aortic valve implantation retrograde from the femoral artery Circulation 113 2006 842 850
    • (2006) Circulation , vol.113 , pp. 842-850
    • Webb, J.G.1    Chandavimol, M.2    Thompson, C.3
  • 8
    • 77954621513 scopus 로고    scopus 로고
    • Thirty-day results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve
    • M. Thomas, G. Schymik, and T. Walther Thirty-day results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry: a European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve Circulation 122 2010 62 69
    • (2010) Circulation , vol.122 , pp. 62-69
    • Thomas, M.1    Schymik, G.2    Walther, T.3
  • 9
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • M.B. Leon, C.R. Smith, and M. Mack Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery N Engl J Med 363 2010 1597 1607
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3
  • 10
    • 84880584190 scopus 로고    scopus 로고
    • A randomized evaluation of the SAPIEN XT transcatheter valve system in patients with aortic stenosis who are not candidates for surgery: PARTNER II, inoperable cohort
    • for the PARTNER II investigators March 10, 2013; San Francisco, CA
    • Leon MB, for the PARTNER II investigators. A randomized evaluation of the SAPIEN XT transcatheter valve system in patients with aortic stenosis who are not candidates for surgery: PARTNER II, inoperable cohort. Paper presented at the 62nd Annual Scientific Session of the American College of Cardiology; March 10, 2013; San Francisco, CA.
    • 62nd Annual Scientific Session of the American College of Cardiology
    • Leon, M.B.1
  • 11
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • C.R. Smith, M.B. Leon, and M.J. Mack Transcatheter versus surgical aortic-valve replacement in high-risk patients N Engl J Med 364 2011 2187 2198
    • (2011) N Engl J Med , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    Mack, M.J.3
  • 12
    • 84893345659 scopus 로고    scopus 로고
    • 30-Day Outcomes from the SOURCE XT TAVI Post Approval Study
    • May, 2012; Paris, France
    • Wendler O. 30-Day Outcomes from the SOURCE XT TAVI Post Approval Study. Paper presented at: EuroPCR 2012; May, 2012; Paris, France.
    • EuroPCR 2012
    • Wendler, O.1
  • 13
    • 84887950245 scopus 로고    scopus 로고
    • Outcomes following transcatheter aortic valve replacement in the United States
    • M. Mack, J. Brennan, and R. Brindis Outcomes following transcatheter aortic valve replacement in the United States JAMA 310 2013 2069 2077
    • (2013) JAMA , vol.310 , pp. 2069-2077
    • Mack, M.1    Brennan, J.2    Brindis, R.3
  • 14
    • 84899811656 scopus 로고    scopus 로고
    • Transcatheter aortic-valve replacement with a self-expanding prosthesis
    • D.H. Adams, J.J. Popma, and M.J. Reardon Transcatheter aortic-valve replacement with a self-expanding prosthesis N Engl J Med 370 2014 1790 1798
    • (2014) N Engl J Med , vol.370 , pp. 1790-1798
    • Adams, D.H.1    Popma, J.J.2    Reardon, M.J.3
  • 15
    • 84865848038 scopus 로고    scopus 로고
    • Cerebral embolization during transcatheter aortic valve implantation: A transcranial Doppler study
    • P. Kahlert, F. Al-Rashid, and P. Dottger Cerebral embolization during transcatheter aortic valve implantation: a transcranial Doppler study Circulation 126 2012 1245 1255
    • (2012) Circulation , vol.126 , pp. 1245-1255
    • Kahlert, P.1    Al-Rashid, F.2    Dottger, P.3
  • 16
    • 79251565276 scopus 로고    scopus 로고
    • Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis
    • C. Tamburino, D. Capodanno, and A. Ramondo Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis Circulation 123 2011 299 308
    • (2011) Circulation , vol.123 , pp. 299-308
    • Tamburino, C.1    Capodanno, D.2    Ramondo, A.3
  • 17
    • 84861534743 scopus 로고    scopus 로고
    • Predictive factors, efficacy and safety of balloon post-dilation following transcatheter aortic valve implantation with a balloon-expandable valve
    • L. Nombella-Franco, J. Rodés-Cabau, and R. DeLarochellière Predictive factors, efficacy and safety of balloon post-dilation following transcatheter aortic valve implantation with a balloon-expandable valve J Am Coll Cardiol Intv 5 2012 499 512
    • (2012) J Am Coll Cardiol Intv , vol.5 , pp. 499-512
    • Nombella-Franco, L.1    Rodés-Cabau, J.2    Delarochellière, R.3
  • 18
    • 84879176272 scopus 로고    scopus 로고
    • Efficacy and safety of postdilatation to reduce paravalvular regurgitation during balloon-expandable transcatheter aortic valve replacement
    • B. Daneault, E. Koss, and R.T. Hahn Efficacy and safety of postdilatation to reduce paravalvular regurgitation during balloon-expandable transcatheter aortic valve replacement Circ Cardiovasc Interv 6 2013 85 91
    • (2013) Circ Cardiovasc Interv , vol.6 , pp. 85-91
    • Daneault, B.1    Koss, E.2    Hahn, R.T.3
  • 19
    • 84904970354 scopus 로고    scopus 로고
    • Outcomes with post-dilation following transcatheter aortic valve replacement: The PARTNER i trial (Placement of Aortic Transcatheter Valve)
    • R.T. Hahn, P. Pibarot, and J. Webb Outcomes with post-dilation following transcatheter aortic valve replacement: the PARTNER I trial (Placement of Aortic Transcatheter Valve) J Am Coll Cardiol Intv 7 2014 781 789
    • (2014) J Am Coll Cardiol Intv , vol.7 , pp. 781-789
    • Hahn, R.T.1    Pibarot, P.2    Webb, J.3
  • 20
    • 84867839502 scopus 로고    scopus 로고
    • Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve
    • M. Urena, M. Mok, and V. Serra Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve J Am Coll Cardiol 60 2012 1743 1752
    • (2012) J Am Coll Cardiol , vol.60 , pp. 1743-1752
    • Urena, M.1    Mok, M.2    Serra, V.3
  • 21
    • 84896075428 scopus 로고    scopus 로고
    • Intentional underexpansion of balloon-expandable transcatheter aortic valves in patients with borderline annular sizes: Proof of concept and clinical implications
    • M. Barbanti, J. Leipsic, and R. BInder Intentional underexpansion of balloon-expandable transcatheter aortic valves in patients with borderline annular sizes: proof of concept and clinical implications J Am Coll Cardiol 63 2014 976 981
    • (2014) J Am Coll Cardiol , vol.63 , pp. 976-981
    • Barbanti, M.1    Leipsic, J.2    Binder, R.3
  • 22
    • 84964198068 scopus 로고    scopus 로고
    • Incidence and severity of paravalvular aortic regurgitation with MDCT nominal area oversizing or undersizing after transcatheter heart valve replacement with the SAPIEN 3: A comparison with the SAPIEN XT
    • In press
    • T. Yang, J. Webb, and P. Blanke Incidence and severity of paravalvular aortic regurgitation with MDCT nominal area oversizing or undersizing after transcatheter heart valve replacement with the SAPIEN 3: a comparison with the SAPIEN XT J Am Coll Cardiol Intv 2014 In press.
    • (2014) J Am Coll Cardiol Intv
    • Yang, T.1    Webb, J.2    Blanke, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.