메뉴 건너뛰기




Volumn 7, Issue 9, 2014, Pages 1014-1021

Impact of balloon post-dilation on clinical outcomes after transcatheter aortic valve replacement with the self-expanding CoreValve prosthesis

(27)  Barbanti, Marco a,b   Petronio, Anna Sonia c   Capodanno, Davide a,b   Ettori, Federica d   Colombo, Antonio e   Bedogni, Francesco f   De Marco, Federico g   De Carlo, Marco c   Fiorina, Claudia d   Latib, Azeem e   Testa, Luca f   Bruschi, Giuseppe g   Poli, Arnaldo h   Giannini, Cristina c   Curello, Salvatore d   Maffeo, Diego d   Sgroi, Carmelo a,b   Martina, Paola h   Gulino, Simona a   Patanè, Martina a   more..


Author keywords

post dilation; TAVR; underexpansion

Indexed keywords

AGED; AORTA DISSECTION; AORTA STENOSIS; AORTA VALVE REGURGITATION; ARTICLE; ARTIFICIAL HEART PACEMAKER; BALLOON CATHETER; BALLOON DILATATION; BALLOON POST DILATION; CARDIOVASCULAR MORTALITY; CLINICAL EFFECTIVENESS; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; FOLLOW UP; HEART LEFT BUNDLE BRANCH BLOCK; HEART LEFT VENTRICLE EJECTION FRACTION; HEART MUSCLE CONDUCTION DISTURBANCE; HEART VENTRICLE PERFORATION; HUMAN; MAJOR CLINICAL STUDY; MALE; MITRAL VALVE REGURGITATION; OUTCOME ASSESSMENT; PATIENT SAFETY; PERCUTANEOUS AORTIC VALVE; PERCUTANEOUS CORONARY INTERVENTION; PROSPECTIVE STUDY; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSLUMINAL VALVULOPLASTY; VASCULAR GUIDE WIRE; ADVERSE EFFECTS; AORTA VALVE; AORTIC VALVE INSUFFICIENCY; AORTIC VALVE STENOSIS; CEREBROVASCULAR DISORDERS; CLINICAL TRIAL; DEVICES; FACTUAL DATABASE; HEART CATHETERIZATION; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; HEMODYNAMICS; ITALY; KAPLAN MEIER METHOD; MORTALITY; MULTICENTER STUDY; MYOCARDIAL INFARCTION; PATHOPHYSIOLOGY; PROSTHESIS; RISK FACTOR; TIME; TREATMENT OUTCOME; VERY ELDERLY;

EID: 84908133958     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2014.03.009     Document Type: Article
Times cited : (49)

References (14)
  • 1
    • 84860494889 scopus 로고    scopus 로고
    • Transcatheter aortic-valve replacement for inoperable severe aortic stenosis
    • PARTNER Trial Investigators
    • R.R. Makkar, G.P. Fontana, H. Jilaihawi PARTNER Trial Investigators Transcatheter aortic-valve replacement for inoperable severe aortic stenosis N Engl J Med 366 2012 1696 1704
    • (2012) N Engl J Med , vol.366 , pp. 1696-1704
    • Makkar, R.R.1    Fontana, G.P.2    Jilaihawi, H.3
  • 2
    • 84860466759 scopus 로고    scopus 로고
    • Two-year outcomes after transcatheter or surgical aortic-valve replacement
    • PARTNER Trial Investigators
    • S.K. Kodali, M.R. Williams, C.R. Smith PARTNER Trial Investigators Two-year outcomes after transcatheter or surgical aortic-valve replacement N Engl J Med 366 2012 1686 1695
    • (2012) N Engl J Med , vol.366 , pp. 1686-1695
    • Kodali, S.K.1    Williams, M.R.2    Smith, C.R.3
  • 3
    • 84875975723 scopus 로고    scopus 로고
    • Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: Meta-analysis and systematic review of literature
    • G. Athappan, E. Patvardhan, and E.M. Tuzcu Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature J Am Coll Cardiol 61 2013 1585 1595
    • (2013) J Am Coll Cardiol , vol.61 , pp. 1585-1595
    • Athappan, G.1    Patvardhan, E.2    Tuzcu, E.M.3
  • 4
    • 77956839815 scopus 로고    scopus 로고
    • Management of implant failure during transcatheter aortic valve implantation
    • G.P. Ussia, M. Barbanti, and S. Immè Management of implant failure during transcatheter aortic valve implantation Catheter Cardiovasc Interv 76 2010 440 449
    • (2010) Catheter Cardiovasc Interv , vol.76 , pp. 440-449
    • Ussia, G.P.1    Barbanti, M.2    Immè, S.3
  • 5
    • 84861534743 scopus 로고    scopus 로고
    • Predictive factors, efficacy, and safety of balloon post-dilation after transcatheter aortic valve implantation with a balloon-expandable valve
    • L. Nombela-Franco, J. Rodés-Cabau, and R. DeLarochellière Predictive factors, efficacy, and safety of balloon post-dilation after transcatheter aortic valve implantation with a balloon-expandable valve J Am Coll Cardiol Intv 5 2012 499 512
    • (2012) J Am Coll Cardiol Intv , vol.5 , pp. 499-512
    • Nombela-Franco, L.1    Rodés-Cabau, J.2    Delarochellière, R.3
  • 6
    • 84879176272 scopus 로고    scopus 로고
    • Efficacy and safety of postdilatation to reduce paravalvular regurgitation during balloon-expandable transcatheter aortic valve replacement
    • B. Daneault, E. Koss, and R.T. Hahn Efficacy and safety of postdilatation to reduce paravalvular regurgitation during balloon-expandable transcatheter aortic valve replacement Circ Cardiovasc Interv 6 2013 85 91
    • (2013) Circ Cardiovasc Interv , vol.6 , pp. 85-91
    • Daneault, B.1    Koss, E.2    Hahn, R.T.3
  • 7
    • 84905444008 scopus 로고    scopus 로고
    • Usefulness of contrast injection during balloon aortic valvuloplasty before transcatheter aortic valve replacement: A pilot study
    • M. Barbanti, C. Sgroi, and S. Immè Usefulness of contrast injection during balloon aortic valvuloplasty before transcatheter aortic valve replacement: a pilot study EuroIntervention 10 2014 241 247
    • (2014) EuroIntervention , vol.10 , pp. 241-247
    • Barbanti, M.1    Sgroi, C.2    Immè, S.3
  • 8
    • 67649576622 scopus 로고    scopus 로고
    • Procedural success and 30-day clinical outcomes after percutaneous aortic valve replacement using current third-generation self-expanding CoreValve prosthesis
    • C. Tamburino, D. Capodanno, and M. Mulè Procedural success and 30-day clinical outcomes after percutaneous aortic valve replacement using current third-generation self-expanding CoreValve prosthesis J Invasive Cardiol 21 2009 93 98
    • (2009) J Invasive Cardiol , vol.21 , pp. 93-98
    • Tamburino, C.1    Capodanno, D.2    Mulè, M.3
  • 9
    • 70349202652 scopus 로고    scopus 로고
    • Expanding the eligibility for transcatheter aortic valve implantation the trans-subclavian retrograde approach using: The III generation CoreValve Revalving system
    • C. Fraccaro, M. Napodano, and G. Tarantini Expanding the eligibility for transcatheter aortic valve implantation the trans-subclavian retrograde approach using: the III generation CoreValve Revalving system J Am Coll Cardiol Intv 2 2009 828 833
    • (2009) J Am Coll Cardiol Intv , vol.2 , pp. 828-833
    • Fraccaro, C.1    Napodano, M.2    Tarantini, G.3
  • 10
    • 84864258184 scopus 로고    scopus 로고
    • Direct aortic access for transcatheter self-expanding aortic bioprosthetic valves implantation
    • G. Bruschi, F. de Marco, and L. Botta Direct aortic access for transcatheter self-expanding aortic bioprosthetic valves implantation Ann Thorac Surg 94 2012 497 503
    • (2012) Ann Thorac Surg , vol.94 , pp. 497-503
    • Bruschi, G.1    De Marco, F.2    Botta, L.3
  • 11
    • 78651337155 scopus 로고    scopus 로고
    • Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: A consensus report from the Valve Academic Research Consortium
    • M.B. Leon, N. Piazza, and E. Nikolsky Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: a consensus report from the Valve Academic Research Consortium J Am Coll Cardiol 57 2011 253 269
    • (2011) J Am Coll Cardiol , vol.57 , pp. 253-269
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3
  • 12
    • 84877347266 scopus 로고    scopus 로고
    • Evaluation and management of paravalvular aortic regurgitation after transcatheter aortic valve replacement
    • J.M. Sinning, M. Vasa-Nicotera, and D. Chin Evaluation and management of paravalvular aortic regurgitation after transcatheter aortic valve replacement J Am Coll Cardiol 62 2013 11 20
    • (2013) J Am Coll Cardiol , vol.62 , pp. 11-20
    • Sinning, J.M.1    Vasa-Nicotera, M.2    Chin, D.3
  • 13
    • 84856460597 scopus 로고    scopus 로고
    • Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation
    • K. Takagi, A. Latib, and R. Al-Lamee Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation Catheter Cardiovasc Interv 78 2011 432 443
    • (2011) Catheter Cardiovasc Interv , vol.78 , pp. 432-443
    • Takagi, K.1    Latib, A.2    Al-Lamee, R.3
  • 14
    • 79951985830 scopus 로고    scopus 로고
    • The valve-in-valve technique for treatment of aortic bioprosthesis malposition an analysis of incidence and 1-year clinical outcomes from the Italian CoreValve registry
    • G.P. Ussia, M. Barbanti, and A. Ramondo The valve-in-valve technique for treatment of aortic bioprosthesis malposition an analysis of incidence and 1-year clinical outcomes from the Italian CoreValve registry J Am Coll Cardiol 57 2011 1062 1068
    • (2011) J Am Coll Cardiol , vol.57 , pp. 1062-1068
    • Ussia, G.P.1    Barbanti, M.2    Ramondo, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.