메뉴 건너뛰기




Volumn 166, Issue 3, 2013, Pages 652-657

Aortic valve calcium score as a predictor for outcome after TAVI using the CoreValve revalving system

Author keywords

Aortic stenosis; Calcium score; CT; TAVI; Transcatheter aortic valve implantation

Indexed keywords

AGED; ANGIOCARDIOGRAPHY; AORTA VALVE PROSTHESIS; AORTA VALVE REGURGITATION; AORTA VALVE STENOSIS; AORTIC VALVE CALCIUM SCORE; ARTICLE; BALLOON; CARDIOGENIC SHOCK; CARDIOVASCULAR PARAMETERS; CATHETER SHEATH; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; CONTROLLED STUDY; DISEASE CLASSIFICATION; DISEASE SEVERITY; ECHOCARDIOGRAPH; FEMALE; GUIDE WIRE; HEART LEFT VENTRICLE EJECTION FRACTION; HUMAN; MAJOR CLINICAL STUDY; MALE; MORTALITY; OUTCOME ASSESSMENT; PRIORITY JOURNAL; SELF EXPANDING STENT; SURVIVAL RATE; TRANSCATHETER AORTIC VALVE IMPLANTATION; VERY ELDERLY; AORTA VALVE; AORTIC VALVE STENOSIS; CALCINOSIS; FOLLOW UP; HEART CATHETERIZATION; HEART VALVE REPLACEMENT; MULTIDETECTOR COMPUTED TOMOGRAPHY; PATHOLOGY; PREDICTIVE VALUE; PROCEDURES; RADIOGRAPHY; SEVERITY OF ILLNESS INDEX; TREATMENT OUTCOME;

EID: 84899645349     PISSN: 01675273     EISSN: 18741754     Source Type: Journal    
DOI: 10.1016/j.ijcard.2011.11.091     Document Type: Article
Times cited : (80)

References (35)
  • 1
    • 33749634251 scopus 로고    scopus 로고
    • Percutaneous implantation of the core-valve self-expanding valve prosthesis in high-risk patients with aortic valve disease: The siegburg first-in-man study
    • Grube E, Laborde JC, Gerckens U, et al. Percutaneous implantation of the Core-Valve self-expanding valve prosthesis in high-risk patients with aortic valve disease: the Siegburg first-in-man study. Circulation 2006; 114: 1616-24.
    • (2006) Circulation , vol.114 , pp. 1616-1624
    • Grube, E.1    Laborde, J.C.2    Gerckens, U.3
  • 2
    • 77954860710 scopus 로고    scopus 로고
    • Immediate and mid-term results of transfe-moral aortic valve implantation using either the edwards sapien transcatheter heart valve or the medtronic CoreValve system in high-risk patients with aortic stenosis
    • Attias D, Himbert D, Ducrocq G, et al. Immediate and mid-term results of transfe-moral aortic valve implantation using either the Edwards Sapien transcatheter heart valve or the Medtronic CoreValve System in high-risk patients with aortic stenosis. Arch Cardiovasc Dis 2010; 103: 236-45.
    • (2010) Arch Cardiovasc Dis , vol.103 , pp. 236-245
    • Attias, D.1    Himbert, D.2    Ducrocq, G.3
  • 3
    • 78449256676 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Predictors of procedural success - The siegburg-bern experience
    • Buellesfeld L, Wenaweser P, Gerckens U, et al. Transcatheter aortic valve implantation: predictors of procedural success - the Siegburg-Bern experience. Eur Heart J 2010; 31: 984-91.
    • (2010) Eur Heart J , vol.31 , pp. 984-991
    • Buellesfeld, L.1    Wenaweser, P.2    Gerckens, U.3
  • 4
    • 78549256704 scopus 로고    scopus 로고
    • Comparison between transcatheter and surgical prosthetic valve implantation in patients with severe aortic stenosis and reduced left ventricular ejection fraction
    • Clavel MA, Webb JG, Rodes-Cabau J, et al. Comparison between transcatheter and surgical prosthetic valve implantation in patients with severe aortic stenosis and reduced left ventricular ejection fraction. Circulation 2010; 122: 1928-36.
    • (2010) Circulation , vol.122 , pp. 1928-1936
    • Clavel, M.A.1    Webb, J.G.2    Rodes-Cabau, J.3
  • 5
    • 78651469380 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Early results of the FRANCE (FRench aortic national CoreValve and edwards) registry
    • Eltchaninoff H, Prat A, Gilard M, et al. Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry. Eur Heart J 2011; 32(2): 191-7.
    • (2011) Eur Heart J , vol.32 , Issue.2 , pp. 191-197
    • Eltchaninoff, H.1    Prat, A.2    Gilard, M.3
  • 6
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • Leon MB, Smith CR, Mack M, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 2010; 363: 1597-607.
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3
  • 7
    • 78651520483 scopus 로고    scopus 로고
    • One year follow-up of the multi-centre european PARTNER transcatheter heart valve study
    • Lefevre T, Kappetein AP, Wolner E, et al. One year follow-up of the multi-centre European PARTNER transcatheter heart valve study. Eur Heart J 2011; 32: 148-57.
    • (2011) Eur Heart J , vol.32 , pp. 148-157
    • Lefevre, T.1    Kappetein, A.P.2    Wolner, E.3
  • 8
    • 79251565276 scopus 로고    scopus 로고
    • Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis
    • Tamburino C, Capodanno D, Ramondo A, et al. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation 2011; 123: 299-308.
    • (2011) Circulation , vol.123 , pp. 299-308
    • Tamburino, C.1    Capodanno, D.2    Ramondo, A.3
  • 9
    • 78349239329 scopus 로고    scopus 로고
    • Complications of transcatheter aortic valve implantation with the cor-evalve - What have we learned so far?
    • Moussa ID Complications of transcatheter aortic valve implantation with the cor-evalve - what have we learned so far? Catheter Cardiovasc Interv 2010; 76: 767-8.
    • (2010) Catheter Cardiovasc Interv , vol.76 , pp. 767-768
    • Moussa, I.D.1
  • 10
    • 78650573226 scopus 로고    scopus 로고
    • Cerebral embolism following trans-catheter aortic valve implantation comparison of transfemoral and transapical approaches
    • Rodes-Cabau J, Dumont E, Boone RH, et al. Cerebral embolism following trans-catheter aortic valve implantation comparison of transfemoral and transapical approaches. J Am Coll Cardiol 2010; 57: 18-28.
    • (2010) J Am Coll Cardiol , vol.57 , pp. 18-28
    • Rodes-Cabau, J.1    Dumont, E.2    Boone, R.H.3
  • 11
    • 78149452061 scopus 로고    scopus 로고
    • Incidence and predictors of atrioventricular conduction impairment after transcatheter aortic valve implantation
    • Roten L, Wenaweser P, Delacretaz E, et al. Incidence and predictors of atrioventricular conduction impairment after transcatheter aortic valve implantation. Am J Cardiol 2010; 106: 1473-80.
    • (2010) Am J Cardiol , vol.106 , pp. 1473-1480
    • Roten, L.1    Wenaweser, P.2    Delacretaz, E.3
  • 12
    • 78649962873 scopus 로고    scopus 로고
    • Migration of a transcatheter aortic valve in the left ventricular outflow tract
    • Seipelt RG, Hanekop G, Schillinger W. Migration of a transcatheter aortic valve in the left ventricular outflow tract. Heart 2010; 96: 1949-50.
    • (2010) Heart , vol.96 , pp. 1949-1950
    • Seipelt, R.G.1    Hanekop, G.2    Schillinger, W.3
  • 13
    • 77957276107 scopus 로고    scopus 로고
    • Acute left main obstructions following TAVI
    • Stabile E, Sorropago G, Cioppa A, et al. Acute left main obstructions following TAVI. Euro Intervention 2010; 6: 100-5.
    • (2010) Euro Intervention , vol.6 , pp. 100-105
    • Stabile, E.1    Sorropago, G.2    Cioppa, A.3
  • 14
    • 79955929785 scopus 로고    scopus 로고
    • The impact of percutaneous implantation of aortic valve prosthesis in the treatment of severe aortic stenosis
    • Caballero-Borrego J, Alonso-Briales JH, Munoz-Garcia A, et al. The impact of percutaneous implantation of aortic valve prosthesis in the treatment of severe aortic stenosis. Int J Cardiol 2011; 149: 128-30.
    • (2011) Int J Cardiol , vol.149 , pp. 128-130
    • Caballero-Borrego, J.1    Alonso-Briales, J.H.2    Munoz-Garcia, A.3
  • 15
    • 73649110271 scopus 로고    scopus 로고
    • Multimodality quantitative imaging of aortic root for transcatheter aortic valve implantation: More complex than it appears
    • Tuzcu EM, Kapadia SR, Schoenhagen P. Multimodality quantitative imaging of aortic root for transcatheter aortic valve implantation: more complex than it appears. J Am Coll Cardiol 2010; 55: 195-7.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 195-197
    • Tuzcu, E.M.1    Kapadia, S.R.2    Schoenhagen, P.3
  • 16
    • 77957064982 scopus 로고    scopus 로고
    • Cardiac CT: Necessary for precise sizing for transcatheter aortic implantation
    • Schultz CJ, Moelker AD, Tzikas A, et al. Cardiac CT: necessary for precise sizing for transcatheter aortic implantation. Euro Intervention 2010; 6(Suppl. G):G6-G13.
    • (2010) Euro Intervention , vol.6 , Issue.SUPPL. G
    • Schultz, C.J.1    Moelker, A.D.2    Tzikas, A.3
  • 17
    • 78649686007 scopus 로고    scopus 로고
    • Aortic annulus sizing prior to transcatheter aortic valve implantation: More answers yet more questions!!
    • Moussa ID Aortic annulus sizing prior to transcatheter aortic valve implantation: more answers yet more questions!! Catheter Cardiovasc Interv 2010; 76: 1020-1.
    • (2010) Catheter Cardiovasc Interv , vol.76 , pp. 1020-1021
    • Moussa, I.D.1
  • 18
    • 73649096192 scopus 로고    scopus 로고
    • Multimodal assessment of the aortic annulus diameter: Implications for transcatheter aortic valve implantation
    • Messika-Zeitoun D, Serfaty JM, Brochet E, et al. Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation. J Am Coll Cardiol 2010; 55: 186-94.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 186-194
    • Messika-Zeitoun, D.1    Serfaty, J.M.2    Brochet, E.3
  • 19
    • 79952278899 scopus 로고    scopus 로고
    • Multimodality imaging in transcatheter aortic valve implantation: Key steps to assess procedural feasibility
    • Delgado V, Ewe SH, Ng AC, et al. Multimodality imaging in transcatheter aortic valve implantation: key steps to assess procedural feasibility. Euro Intervention 2010; 6: 643-52.
    • (2010) Euro Intervention , vol.6 , pp. 643-652
    • Delgado, V.1    Ewe, S.H.2    Ng, A.C.3
  • 20
    • 77952027747 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function
    • Delgado V, Ng AC, van de Veire NR, et al. Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function. Eur Heart J 2010; 31: 1114-23.
    • (2010) Eur Heart J , vol.31 , pp. 1114-1123
    • Delgado, V.1    Ng, A.C.2    Van De Veire, N.R.3
  • 21
    • 78649706404 scopus 로고    scopus 로고
    • Relation of aortic valve calcium detected by cardiac computed tomography to all-cause mortality
    • Blaha MJ, Budoff MJ, Rivera JJ, et al. Relation of aortic valve calcium detected by cardiac computed tomography to all-cause mortality. Am J Cardiol 2010; 106: 1787-91.
    • (2010) Am J Cardiol , vol.106 , pp. 1787-1791
    • Blaha, M.J.1    Budoff, M.J.2    Rivera, J.J.3
  • 22
    • 44949107279 scopus 로고    scopus 로고
    • Transcatheter valve implantation for patients with aortic stenosis: A position statement from the european association of cardio-thoracic surgery (EACTS) and the european society of cardiology (ESC), in collaboration with the european association of percutaneous cardiovascular interventions (EAPCI)
    • Vahanian A, Alfieri O, Al-Attar N, et al. Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur Heart J 2008; 29: 1463-70.
    • (2008) Eur Heart J , vol.29 , pp. 1463-1470
    • Vahanian, A.1    Alfieri, O.2    Al-Attar, N.3
  • 23
    • 28844467934 scopus 로고    scopus 로고
    • First report on a human percutaneous transluminal implantation of a self-expanding valve prosthesis for interventional treatment of aortic valve stenosis
    • Grube E, Laborde JC, Zickmann B, et al. First report on a human percutaneous transluminal implantation of a self-expanding valve prosthesis for interventional treatment of aortic valve stenosis. Catheter Cardiovasc Interv 2005; 66: 465-9.
    • (2005) Catheter Cardiovasc Interv , vol.66 , pp. 465-469
    • Grube, E.1    Laborde, J.C.2    Zickmann, B.3
  • 24
    • 0038376203 scopus 로고    scopus 로고
    • Coronary artery calcium quantification at multi-detector row CT: Influence of heart rate and measurement methods on interacquisition variability initial experience
    • Hong C, Bae KT, Pilgram TK, Zhu F. Coronary artery calcium quantification at multi-detector row CT: influence of heart rate and measurement methods on interacquisition variability initial experience. Radiology 2003; 228: 95-100.
    • (2003) Radiology , vol.228 , pp. 95-100
    • Hong, C.1    Bae, K.T.2    Pilgram, T.K.3    Zhu, F.4
  • 25
    • 0037612249 scopus 로고    scopus 로고
    • Coronary artery calcium: Accuracy and reproducibility of measurements with multi-detector row CT - Assessment of effects of different thresholds and quantification methods
    • Hong C, Bae KT, Pilgram TK. Coronary artery calcium: accuracy and reproducibility of measurements with multi-detector row CT - assessment of effects of different thresholds and quantification methods. Radiology 2003; 227: 795-801.
    • (2003) Radiology , vol.227 , pp. 795-801
    • Hong, C.1    Bae, K.T.2    Pilgram, T.K.3
  • 26
    • 0036242437 scopus 로고    scopus 로고
    • Coronary artery calcium: Absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies
    • Hong C, Becker CR, Schoepf UJ, Ohnesorge B, Bruening R, Reiser MF. Coronary artery calcium: absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies. Radiology 2002; 223: 474-80.
    • (2002) Radiology , vol.223 , pp. 474-480
    • Hong, C.1    Becker, C.R.2    Schoepf, U.J.3    Ohnesorge, B.4    Bruening, R.5    Reiser, M.F.6
  • 27
    • 75249106893 scopus 로고    scopus 로고
    • Relationship between the logistic EuroSCORE and the society of thoracic surgeons predicted risk of mortality score in patients implanted with the CoreValve ReValving system - A bern-rotterdam study
    • Piazza N, Wenaweser P, van Gameren M, et al. Relationship between the logistic EuroSCORE and the Society of Thoracic Surgeons Predicted Risk of Mortality score in patients implanted with the CoreValve ReValving system - a Bern-Rotterdam Study. Am Heart J 2010; 159: 323-9.
    • (2010) Am Heart J , vol.159 , pp. 323-329
    • Piazza, N.1    Wenaweser, P.2    Van Gameren, M.3
  • 28
    • 64649096899 scopus 로고    scopus 로고
    • Relationship of metabolic syndrome with incident aortic valve calcium and aortic valve calcium progression: The multi-ethnic study of atherosclerosis (MESA)
    • Katz R, Budoff MJ, Takasu J, et al. Relationship of metabolic syndrome with incident aortic valve calcium and aortic valve calcium progression: the Multi-Ethnic Study of Atherosclerosis (MESA). Diabetes 2009; 58: 813-9.
    • (2009) Diabetes , vol.58 , pp. 813-819
    • Katz, R.1    Budoff, M.J.2    Takasu, J.3
  • 29
    • 76349096736 scopus 로고    scopus 로고
    • Relationship of aortic valve calcification with coronary artery calcium severity: The multi-ethnic study of atherosclerosis (MESA)
    • Nasir K, Katz R, Al-Mallah M, et al. Relationship of aortic valve calcification with coronary artery calcium severity: the Multi-Ethnic Study of Atherosclerosis (MESA). J Cardiovasc Comput Tomogr 2010; 4: 41-6.
    • (2010) J Cardiovasc Comput Tomogr , vol.4 , pp. 41-46
    • Nasir, K.1    Katz, R.2    Al-Mallah, M.3
  • 30
    • 76849105220 scopus 로고    scopus 로고
    • Incidence and progression of aortic valve calcium in the multi-ethnic study of atherosclerosis (MESA)
    • Owens DS, Katz R, Takasu J, Kronmal R, Budoff MJ, O'Brien KD. Incidence and progression of aortic valve calcium in the Multi-ethnic Study of Atherosclerosis (MESA). Am J Cardiol 2010; 105: 701-8.
    • (2010) Am J Cardiol , vol.105 , pp. 701-708
    • Owens, D.S.1    Katz, R.2    Takasu, J.3    Kronmal, R.4    Budoff, M.J.5    O'Brien, K.D.6
  • 32
    • 76649127789 scopus 로고    scopus 로고
    • Procedural and mid-term results in patients with aortic stenosis treated with implantation of 2 (in-series) CoreValve prostheses in 1 procedure
    • Gerckens U, Latsios G, Mueller R, et al. Procedural and mid-term results in patients with aortic stenosis treated with implantation of 2 (in-series) CoreValve prostheses in 1 procedure. JACC Cardiovasc Interv 2010; 3: 244-50.
    • (2010) JACC Cardiovasc Interv , vol.3 , pp. 244-250
    • Gerckens, U.1    Latsios, G.2    Mueller, R.3
  • 33
    • 76649123667 scopus 로고    scopus 로고
    • Correlation of device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis
    • John D, Buellesfeld L, Yuecel S, et al. Correlation of device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis. JACC Cardiovasc Interv 2010; 3: 233-43.
    • (2010) JACC Cardiovasc Interv , vol.3 , pp. 233-243
    • John, D.1    Buellesfeld, L.2    Yuecel, S.3
  • 34
    • 79958176452 scopus 로고    scopus 로고
    • Mechanisms, treatment and course of paravalvular aortic regurgitation after percutaneous implantation of the CoreValve aortic prosthesis
    • Munoz-Garcia AJ, Alonso-Briales JH, Jimenez-Navarro MF, et al. Mechanisms, treatment and course of paravalvular aortic regurgitation after percutaneous implantation of the CoreValve aortic prosthesis. Int J Cardiol 2011; 149: 389-92.
    • (2011) Int J Cardiol , vol.149 , pp. 389-392
    • Munoz-Garcia, A.J.1    Alonso-Briales, J.H.2    Jimenez-Navarro, M.F.3
  • 35
    • 79958178970 scopus 로고    scopus 로고
    • Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation
    • Koos R, Mahnken AH, Dohmen G, et al. Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation. Int J Cardiol 2011; 150: 142-5.
    • (2011) Int J Cardiol , vol.150 , pp. 142-145
    • Koos, R.1    Mahnken, A.H.2    Dohmen, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.