메뉴 건너뛰기




Volumn 30, Issue 2, 2016, Pages 201-216

Monitoring high-risk patients: minimally invasive and non-invasive possibilities

Author keywords

cardiac output; echocardiography; haemodynamic monitoring; minimally invasive; non invasive; pulse contour analysis; stroke volume

Indexed keywords

DEVICES; HEMODYNAMICS; HUMAN; PERIOPERATIVE PERIOD; PHYSIOLOGIC MONITORING; RISK; TRENDS;

EID: 84969931596     PISSN: 15216896     EISSN: 1532169X     Source Type: Journal    
DOI: 10.1016/j.bpa.2016.04.006     Document Type: Review
Times cited : (10)

References (89)
  • 1
    • 84866510395 scopus 로고    scopus 로고
    • Mortality after surgery in Europe: a 7 day cohort study
    • [1] Pearse, R.M., Moreno, R.P., Bauer, P., et al. Mortality after surgery in Europe: a 7 day cohort study. Lancet 380 (2012), 1059–1065.
    • (2012) Lancet , vol.380 , pp. 1059-1065
    • Pearse, R.M.1    Moreno, R.P.2    Bauer, P.3
  • 2
    • 84928987193 scopus 로고    scopus 로고
    • Estimated need for surgery worldwide based on prevalence of diseases: a modelling strategy for the WHO Global Health Estimate
    • [2] Rose, J., Weiser, T.G., Hider, P., et al. Estimated need for surgery worldwide based on prevalence of diseases: a modelling strategy for the WHO Global Health Estimate. Lancet Glob Health 3:Suppl. 2 (2015), S13–S20.
    • (2015) Lancet Glob Health , vol.3 , pp. S13-S20
    • Rose, J.1    Weiser, T.G.2    Hider, P.3
  • 3
    • 84930375715 scopus 로고    scopus 로고
    • Estimate of the global volume of surgery in 2012: an assessment supporting improved health outcomes
    • [3] Weiser, T.G., Haynes, A.B., Molina, G., et al. Estimate of the global volume of surgery in 2012: an assessment supporting improved health outcomes. Lancet, 385(Suppl. 2), 2015, S11.
    • (2015) Lancet , vol.385 , pp. S11
    • Weiser, T.G.1    Haynes, A.B.2    Molina, G.3
  • 4
    • 70349610473 scopus 로고    scopus 로고
    • Variation in hospital mortality associated with inpatient surgery
    • [4] Ghaferi, A.A., Birkmeyer, J.D., Dimick, J.B., Variation in hospital mortality associated with inpatient surgery. N Engl J Med 361 (2009), 1368–1375.
    • (2009) N Engl J Med , vol.361 , pp. 1368-1375
    • Ghaferi, A.A.1    Birkmeyer, J.D.2    Dimick, J.B.3
  • 5
    • 24944566109 scopus 로고    scopus 로고
    • Determinants of long-term survival after major surgery and the adverse effect of postoperative complications
    • [5] Khuri, S.F., Henderson, W.G., DePalma, R.G., et al. Determinants of long-term survival after major surgery and the adverse effect of postoperative complications. Ann Surg 242 (2005), 326–341.
    • (2005) Ann Surg , vol.242 , pp. 326-341
    • Khuri, S.F.1    Henderson, W.G.2    DePalma, R.G.3
  • 6
    • 79959733145 scopus 로고    scopus 로고
    • EuSOS: European surgical outcomes study
    • [6] Pearse, R.M., Rhodes, A., Moreno, R., et al. EuSOS: European surgical outcomes study. Eur J Anaesthesiol 28 (2011), 454–456.
    • (2011) Eur J Anaesthesiol , vol.28 , pp. 454-456
    • Pearse, R.M.1    Rhodes, A.2    Moreno, R.3
  • 7
    • 34447630814 scopus 로고    scopus 로고
    • Identification and characterisation of the high-risk surgical population in the United Kingdom
    • [7] Pearse, R.M., Harrison, D.A., James, P., et al. Identification and characterisation of the high-risk surgical population in the United Kingdom. Crit Care, 10, 2006, R81.
    • (2006) Crit Care , vol.10 , pp. R81
    • Pearse, R.M.1    Harrison, D.A.2    James, P.3
  • 8
    • 44949133927 scopus 로고    scopus 로고
    • Mortality and utilisation of critical care resources amongst high-risk surgical patients in a large NHS trust
    • [8] Jhanji, S., Thomas, B., Ely, A., et al. Mortality and utilisation of critical care resources amongst high-risk surgical patients in a large NHS trust. Anaesthesia 63 (2008), 695–700.
    • (2008) Anaesthesia , vol.63 , pp. 695-700
    • Jhanji, S.1    Thomas, B.2    Ely, A.3
  • 9
    • 4344631022 scopus 로고    scopus 로고
    • The effect of critical care outreach on postoperative serious adverse events
    • [9] Story, D.A., Shelton, A.C., Poustie, S.J., et al. The effect of critical care outreach on postoperative serious adverse events. Anaesthesia 59 (2004), 762–766.
    • (2004) Anaesthesia , vol.59 , pp. 762-766
    • Story, D.A.1    Shelton, A.C.2    Poustie, S.J.3
  • 10
    • 84859787405 scopus 로고    scopus 로고
    • A review of the peri-operative care of surgical patients.
    • Knowing the risk. London: National Confidential Enquiry into Patient Outcome and Death. date last accessed.
    • [10] Findlay GA, Protopapa K, Smith N, et al. Knowing the risk. A review of the peri-operative care of surgical patients. London: National Confidential Enquiry into Patient Outcome and Death. http://www/.ncepod.or g.uk/2011report2/do wnloads/POC _fullreport.pdf date last accessed.
    • Findlay, G.A.1    Protopapa, K.2    Smith, N.3
  • 11
    • 31744438011 scopus 로고    scopus 로고
    • Functional hemodynamic monitoring
    • [11] Pinsky, M.R., Payen, D., Functional hemodynamic monitoring. Crit Care 9 (2005), 566–572.
    • (2005) Crit Care , vol.9 , pp. 566-572
    • Pinsky, M.R.1    Payen, D.2
  • 12
    • 84988698623 scopus 로고    scopus 로고
    • The effects of goal-directed fluid therapy based on dynamic parameters on post-surgical outcome: a meta-analysis of randomized controlled trials
    • [12] Benes, J., Giglio, M., Brienza, N., et al. The effects of goal-directed fluid therapy based on dynamic parameters on post-surgical outcome: a meta-analysis of randomized controlled trials. Crit Care, 18, 2014, 584.
    • (2014) Crit Care , vol.18 , pp. 584
    • Benes, J.1    Giglio, M.2    Brienza, N.3
  • 13
    • 84944890296 scopus 로고    scopus 로고
    • Fluid management guided by a continuous non-invasive arterial pressure device is associated with decreased postoperative morbidity after total knee and hip replacement
    • [13] Benes, J., Haidingerova, L., Pouska, J., et al. Fluid management guided by a continuous non-invasive arterial pressure device is associated with decreased postoperative morbidity after total knee and hip replacement. BMC Anesthesiol, 15, 2015, 148.
    • (2015) BMC Anesthesiol , vol.15 , pp. 148
    • Benes, J.1    Haidingerova, L.2    Pouska, J.3
  • 14
    • 84926417476 scopus 로고    scopus 로고
    • Goal-directed fluid therapy with closed-loop assistance during moderate risk surgery using noninvasive cardiac output monitoring: a pilot study
    • [14] Joosten, A., Huynh, T., Suehiro, K., et al. Goal-directed fluid therapy with closed-loop assistance during moderate risk surgery using noninvasive cardiac output monitoring: a pilot study. Br J Anaesth 114 (2015), 886–892.
    • (2015) Br J Anaesth , vol.114 , pp. 886-892
    • Joosten, A.1    Huynh, T.2    Suehiro, K.3
  • 15
    • 0000961898 scopus 로고
    • An experimental study of blood pressure and of pulse pressure in man
    • [15] Erlanger, J., Hooker, D.R., An experimental study of blood pressure and of pulse pressure in man. Johns Hopkins Hosp Rep 12 (1904), 145–378.
    • (1904) Johns Hopkins Hosp Rep , vol.12 , pp. 145-378
    • Erlanger, J.1    Hooker, D.R.2
  • 16
    • 0027195184 scopus 로고
    • Computation of aortic flow from pressure in humans using a nonlinear, three-element model
    • [16] Wesseling, K.H., Jansen, J.R., Settels, J.J., et al. Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J Appl Physiol (1985) 74 (1993), 2566–2573.
    • (1993) J Appl Physiol (1985) , vol.74 , pp. 2566-2573
    • Wesseling, K.H.1    Jansen, J.R.2    Settels, J.J.3
  • 17
    • 79953017467 scopus 로고    scopus 로고
    • Cardiac output monitoring: an integrative perspective
    • [17] Alhashemi, J.A., Cecconi, M., Hofer, C.K., Cardiac output monitoring: an integrative perspective. Crit Care, 15, 2011, 214.
    • (2011) Crit Care , vol.15 , pp. 214
    • Alhashemi, J.A.1    Cecconi, M.2    Hofer, C.K.3
  • 18
    • 84928795847 scopus 로고    scopus 로고
    • Common pitfalls and tips and tricks to get the most out of your transpulmonary thermodilution device: results of a survey and state-of-the-art review
    • [18] Hofkens, P.J., Verrijcken, A., Merveille, K., et al. Common pitfalls and tips and tricks to get the most out of your transpulmonary thermodilution device: results of a survey and state-of-the-art review. Anaesthesiol Intensive Ther 47 (2015), 89–116.
    • (2015) Anaesthesiol Intensive Ther , vol.47 , pp. 89-116
    • Hofkens, P.J.1    Verrijcken, A.2    Merveille, K.3
  • 19
    • 84953314150 scopus 로고    scopus 로고
    • Transcardiopulmonary thermodilution-calibrated arterial waveform analysis: a primer for anesthesiologists and intensivists
    • [19] Laight, N.S., Levin, A.I., Transcardiopulmonary thermodilution-calibrated arterial waveform analysis: a primer for anesthesiologists and intensivists. J Cardiothorac Vasc Anesth 29 (2015), 1051–1064.
    • (2015) J Cardiothorac Vasc Anesth , vol.29 , pp. 1051-1064
    • Laight, N.S.1    Levin, A.I.2
  • 20
    • 84865017866 scopus 로고    scopus 로고
    • A comparison of third-generation semi-invasive arterial waveform analysis with thermodilution in patients undergoing coronary surgery
    • [20] Broch, O., Renner, J., Gruenewald, M., et al. A comparison of third-generation semi-invasive arterial waveform analysis with thermodilution in patients undergoing coronary surgery. Sci World J, 2012, 2012, 451081.
    • (2012) Sci World J , vol.2012 , pp. 451081
    • Broch, O.1    Renner, J.2    Gruenewald, M.3
  • 21
    • 79953827557 scopus 로고    scopus 로고
    • Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients
    • [21] De Backer, D., Marx, G., Tan, A., et al. Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients. Intensive Care Med 37 (2011), 233–240.
    • (2011) Intensive Care Med , vol.37 , pp. 233-240
    • De Backer, D.1    Marx, G.2    Tan, A.3
  • 22
    • 84878336009 scopus 로고    scopus 로고
    • Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo
    • [22] Marque, S., Gros, A., Chimot, L., et al. Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo. J Clin Monit Comput 27 (2013), 273–279.
    • (2013) J Clin Monit Comput , vol.27 , pp. 273-279
    • Marque, S.1    Gros, A.2    Chimot, L.3
  • 23
    • 84858433268 scopus 로고    scopus 로고
    • Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients
    • [23] Monnet, X., Anguel, N., Jozwiak, M., et al. Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients. Br J Anaesth 108 (2012), 615–622.
    • (2012) Br J Anaesth , vol.108 , pp. 615-622
    • Monnet, X.1    Anguel, N.2    Jozwiak, M.3
  • 24
    • 84880528583 scopus 로고    scopus 로고
    • Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes
    • [24] Suehiro, K., Tanaka, K., Funao, T., et al. Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes. Br J Anaesth 111 (2013), 170–177.
    • (2013) Br J Anaesth , vol.111 , pp. 170-177
    • Suehiro, K.1    Tanaka, K.2    Funao, T.3
  • 25
    • 84933679758 scopus 로고    scopus 로고
    • Reliability of a new 4th generation FloTrac algorithm to track cardiac output changes in patients receiving phenylephrine
    • [25] Ji, F., Li, J., Fleming, N., et al. Reliability of a new 4th generation FloTrac algorithm to track cardiac output changes in patients receiving phenylephrine. J Clin Monit Comput 29 (2015), 467–473.
    • (2015) J Clin Monit Comput , vol.29 , pp. 467-473
    • Ji, F.1    Li, J.2    Fleming, N.3
  • 26
    • 77953533489 scopus 로고    scopus 로고
    • Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study
    • [26] Benes, J., Chytra, I., Altmann, P., et al. Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study. Crit Care, 14, 2010, R118.
    • (2010) Crit Care , vol.14 , pp. R118
    • Benes, J.1    Chytra, I.2    Altmann, P.3
  • 27
    • 77953960618 scopus 로고    scopus 로고
    • Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients: a randomized, controlled trial
    • [27] Mayer, J., Boldt, J., Mengistu, A.M., et al. Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients: a randomized, controlled trial. Crit Care, 14, 2010, R18.
    • (2010) Crit Care , vol.14 , pp. R18
    • Mayer, J.1    Boldt, J.2    Mengistu, A.M.3
  • 28
    • 84878282847 scopus 로고    scopus 로고
    • Goal-directed intraoperative fluid therapy guided by stroke volume and its variation in high-risk surgical patients: a prospective randomized multicentre study
    • [28] Scheeren, T.W., Wiesenack, C., Gerlach, H., et al. Goal-directed intraoperative fluid therapy guided by stroke volume and its variation in high-risk surgical patients: a prospective randomized multicentre study. J Clin Monit Comput 27 (2013), 225–233.
    • (2013) J Clin Monit Comput , vol.27 , pp. 225-233
    • Scheeren, T.W.1    Wiesenack, C.2    Gerlach, H.3
  • 29
    • 56349120707 scopus 로고    scopus 로고
    • Reliability of continuous cardiac output measurement during intra-abdominal hypertension relies on repeated calibrations: an experimental animal study
    • [29] Gruenewald, M., Renner, J., Meybohm, P., et al. Reliability of continuous cardiac output measurement during intra-abdominal hypertension relies on repeated calibrations: an experimental animal study. Crit Care, 12, 2008, R132.
    • (2008) Crit Care , vol.12 , pp. R132
    • Gruenewald, M.1    Renner, J.2    Meybohm, P.3
  • 30
    • 84855993098 scopus 로고    scopus 로고
    • Validation of the LiDCO pulse contour system in patients with impaired left ventricular function
    • author reply 88–9
    • [30] Mowat, I., Todman, E., Jaggar, S., Validation of the LiDCO pulse contour system in patients with impaired left ventricular function. Anaesthesia, 67, 2012, 188 author reply 88–9.
    • (2012) Anaesthesia , vol.67 , pp. 188
    • Mowat, I.1    Todman, E.2    Jaggar, S.3
  • 31
    • 84920832773 scopus 로고    scopus 로고
    • Evaluation of the utility of the Vigileo FloTrac(), LiDCO(), USCOM and CardioQ() to detect hypovolaemia in conscious volunteers: a proof of concept study
    • [31] O'Loughlin, E., Ward, M., Crossley, A., et al. Evaluation of the utility of the Vigileo FloTrac(), LiDCO(), USCOM and CardioQ() to detect hypovolaemia in conscious volunteers: a proof of concept study. Anaesthesia 70 (2015), 142–149.
    • (2015) Anaesthesia , vol.70 , pp. 142-149
    • O'Loughlin, E.1    Ward, M.2    Crossley, A.3
  • 32
    • 34250805960 scopus 로고    scopus 로고
    • The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration
    • [32] Bein, B., Meybohm, P., Cavus, E., et al. The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration. Anesth Analg 105 (2007), 107–113.
    • (2007) Anesth Analg , vol.105 , pp. 107-113
    • Bein, B.1    Meybohm, P.2    Cavus, E.3
  • 33
    • 79952062181 scopus 로고    scopus 로고
    • Uncalibrated pulse power analysis fails to reliably measure cardiac output in patients undergoing coronary artery bypass surgery
    • [33] Broch, O., Renner, J., Hocker, J., et al. Uncalibrated pulse power analysis fails to reliably measure cardiac output in patients undergoing coronary artery bypass surgery. Crit Care, 15, 2011, R76.
    • (2011) Crit Care , vol.15 , pp. R76
    • Broch, O.1    Renner, J.2    Hocker, J.3
  • 34
    • 84874382964 scopus 로고    scopus 로고
    • Stroke volume optimization in elective bowel surgery: a comparison between pulse power wave analysis (LiDCOrapid) and oesophageal Doppler (CardioQ)
    • [34] Nordstrom, J., Hallsjo-Sander, C., Shore, R., et al. Stroke volume optimization in elective bowel surgery: a comparison between pulse power wave analysis (LiDCOrapid) and oesophageal Doppler (CardioQ). Br J Anaesth 110 (2013), 374–380.
    • (2013) Br J Anaesth , vol.110 , pp. 374-380
    • Nordstrom, J.1    Hallsjo-Sander, C.2    Shore, R.3
  • 35
    • 84922511808 scopus 로고    scopus 로고
    • Comparison of pulse contour analysis by Pulsioflex and Vigileo to measure and track changes of cardiac output in critically ill patients
    • [35] Monnet, X., Vaquer, S., Anguel, N., et al. Comparison of pulse contour analysis by Pulsioflex and Vigileo to measure and track changes of cardiac output in critically ill patients. Br J Anaesth 114 (2015), 235–243.
    • (2015) Br J Anaesth , vol.114 , pp. 235-243
    • Monnet, X.1    Vaquer, S.2    Anguel, N.3
  • 36
    • 84960124141 scopus 로고    scopus 로고
    • Accuracy of an autocalibrated pulse contour analysis in cardiac surgery patients: a bi-center clinical trial
    • [36] Broch, O., Carbonell, J., Ferrando, C., et al. Accuracy of an autocalibrated pulse contour analysis in cardiac surgery patients: a bi-center clinical trial. BMC Anesthesiol, 15, 2015, 171.
    • (2015) BMC Anesthesiol , vol.15 , pp. 171
    • Broch, O.1    Carbonell, J.2    Ferrando, C.3
  • 37
    • 84883521100 scopus 로고    scopus 로고
    • Perioperative goal-directed hemodynamic therapy based on radial arterial pulse pressure variation and continuous cardiac index trending reduces postoperative complications after major abdominal surgery: a multi-center, prospective, randomized study
    • [37] Salzwedel, C., Puig, J., Carstens, A., et al. Perioperative goal-directed hemodynamic therapy based on radial arterial pulse pressure variation and continuous cardiac index trending reduces postoperative complications after major abdominal surgery: a multi-center, prospective, randomized study. Crit Care, 17, 2013, R191.
    • (2013) Crit Care , vol.17 , pp. R191
    • Salzwedel, C.1    Puig, J.2    Carstens, A.3
  • 38
    • 67849110105 scopus 로고    scopus 로고
    • Perioperative hemodynamic monitoring with transesophageal Doppler technology
    • [38] Schober, P., Loer, S.A., Schwarte, L.A., Perioperative hemodynamic monitoring with transesophageal Doppler technology. Anesth Analg 109 (2009), 340–353.
    • (2009) Anesth Analg , vol.109 , pp. 340-353
    • Schober, P.1    Loer, S.A.2    Schwarte, L.A.3
  • 39
    • 68049142922 scopus 로고    scopus 로고
    • Oesophageal Doppler
    • [39] Singer, M., Oesophageal Doppler. Curr Opin Crit Care 15 (2009), 244–248.
    • (2009) Curr Opin Crit Care , vol.15 , pp. 244-248
    • Singer, M.1
  • 40
    • 84927950049 scopus 로고    scopus 로고
    • Oesophageal Doppler cardiac output monitoring: a longstanding tool with evolving indications and applications
    • [40] Colquhoun, D.A., Roche, A.M., Oesophageal Doppler cardiac output monitoring: a longstanding tool with evolving indications and applications. Best Pract Res Clin Anaesthesiol 28 (2014), 353–362.
    • (2014) Best Pract Res Clin Anaesthesiol , vol.28 , pp. 353-362
    • Colquhoun, D.A.1    Roche, A.M.2
  • 41
    • 0031946626 scopus 로고    scopus 로고
    • Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients
    • [41] Lefrant, J.Y., Bruelle, P., Aya, A.G., et al. Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients. Intensive Care Med 24 (1998), 347–352.
    • (1998) Intensive Care Med , vol.24 , pp. 347-352
    • Lefrant, J.Y.1    Bruelle, P.2    Aya, A.G.3
  • 42
    • 36849055073 scopus 로고    scopus 로고
    • Systematic review of the literature for the use of oesophageal Doppler monitor for fluid replacement in major abdominal surgery
    • [42] Abbas, S.M., Hill, A.G., Systematic review of the literature for the use of oesophageal Doppler monitor for fluid replacement in major abdominal surgery. Anaesthesia 63 (2008), 44–51.
    • (2008) Anaesthesia , vol.63 , pp. 44-51
    • Abbas, S.M.1    Hill, A.G.2
  • 43
    • 85044707653 scopus 로고    scopus 로고
    • Systematic review of the clinical effectiveness and cost-effectiveness of oesophageal Doppler monitoring in critically ill and high-risk surgical patients
    • iii–iv, ix–xii, 1–95
    • [43] Mowatt, G., Houston, G., Hernandez, R., et al. Systematic review of the clinical effectiveness and cost-effectiveness of oesophageal Doppler monitoring in critically ill and high-risk surgical patients. Health Technol Assess, 13, 2009 iii–iv, ix–xii, 1–95.
    • (2009) Health Technol Assess , vol.13
    • Mowatt, G.1    Houston, G.2    Hernandez, R.3
  • 44
    • 33748419499 scopus 로고    scopus 로고
    • Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resection
    • [44] Noblett, S.E., Snowden, C.P., Shenton, B.K., et al. Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resection. Br J Surg 93 (2006), 1069–1076.
    • (2006) Br J Surg , vol.93 , pp. 1069-1076
    • Noblett, S.E.1    Snowden, C.P.2    Shenton, B.K.3
  • 45
    • 79952990404 scopus 로고    scopus 로고
    • Oesophageal Doppler monitoring: should it be routine for high-risk surgical patients?
    • [45] Singer, M., Oesophageal Doppler monitoring: should it be routine for high-risk surgical patients?. Curr Opin Anaesthesiol 24 (2011), 171–176.
    • (2011) Curr Opin Anaesthesiol , vol.24 , pp. 171-176
    • Singer, M.1
  • 46
    • 81055144252 scopus 로고    scopus 로고
    • NICE guidance on CardioQ(TM) oesophageal Doppler monitoring
    • [46] Ghosh, S., Arthur, B., Klein, A.A., NICE guidance on CardioQ(TM) oesophageal Doppler monitoring. Anaesthesia 66 (2011), 1081–1083.
    • (2011) Anaesthesia , vol.66 , pp. 1081-1083
    • Ghosh, S.1    Arthur, B.2    Klein, A.A.3
  • 47
    • 84887847387 scopus 로고    scopus 로고
    • Systematic review and meta-analysis of oesophageal Doppler-guided fluid management in colorectal surgery
    • [47] Srinivasa, S., Lemanu, D.P., Singh, P.P., et al. Systematic review and meta-analysis of oesophageal Doppler-guided fluid management in colorectal surgery. Br J Surg 100 (2013), 1701–1708.
    • (2013) Br J Surg , vol.100 , pp. 1701-1708
    • Srinivasa, S.1    Lemanu, D.P.2    Singh, P.P.3
  • 48
    • 0017032294 scopus 로고
    • Contribution to the continuous indirect blood pressure measurement
    • [48] Penaz, J., Voigt, A., Teichmann, W., Contribution to the continuous indirect blood pressure measurement. Z Gesamte Inn Med 31 (1976), 1030–1033.
    • (1976) Z Gesamte Inn Med , vol.31 , pp. 1030-1033
    • Penaz, J.1    Voigt, A.2    Teichmann, W.3
  • 49
    • 22144477500 scopus 로고    scopus 로고
    • Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger
    • [49] Bogert, L.W., van Lieshout, J.J., Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger. Exp Physiol 90 (2005), 437–446.
    • (2005) Exp Physiol , vol.90 , pp. 437-446
    • Bogert, L.W.1    van Lieshout, J.J.2
  • 50
    • 33746367766 scopus 로고    scopus 로고
    • Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops
    • [50] Fortin, J., Marte, W., Grullenberger, R., et al. Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops. Comput Biol Med 36 (2006), 941–957.
    • (2006) Comput Biol Med , vol.36 , pp. 941-957
    • Fortin, J.1    Marte, W.2    Grullenberger, R.3
  • 51
    • 84938515702 scopus 로고    scopus 로고
    • Continuous noninvasive cardiac output determination using the CNAP system: evaluation of a cardiac output algorithm for the analysis of volume clamp method-derived pulse contour
    • [51] Wagner, J.Y., Grond, J., Fortin, J., et al. Continuous noninvasive cardiac output determination using the CNAP system: evaluation of a cardiac output algorithm for the analysis of volume clamp method-derived pulse contour. J Clin Monit Comput, 2015, 10.1007/s10877-015-9744-1.
    • (2015) J Clin Monit Comput
    • Wagner, J.Y.1    Grond, J.2    Fortin, J.3
  • 52
    • 84878202433 scopus 로고    scopus 로고
    • A comparison of continuous non-invasive arterial pressure with invasive radial and femoral pressure in patients undergoing cardiac surgery
    • [52] Broch, O., Bein, B., Gruenewald, M., et al. A comparison of continuous non-invasive arterial pressure with invasive radial and femoral pressure in patients undergoing cardiac surgery. Minerva Anestesiol 79 (2013), 248–256.
    • (2013) Minerva Anestesiol , vol.79 , pp. 248-256
    • Broch, O.1    Bein, B.2    Gruenewald, M.3
  • 53
    • 84866350766 scopus 로고    scopus 로고
    • Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery
    • [53] Fischer, M.O., Avram, R., Carjaliu, I., et al. Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery. Br J Anaesth 109 (2012), 514–521.
    • (2012) Br J Anaesth , vol.109 , pp. 514-521
    • Fischer, M.O.1    Avram, R.2    Carjaliu, I.3
  • 54
    • 84880525789 scopus 로고    scopus 로고
    • Non-invasive continuous arterial pressure monitoring with Nexfin does not sufficiently replace invasive measurements in critically ill patients
    • [54] Hohn, A., Defosse, J.M., Becker, S., et al. Non-invasive continuous arterial pressure monitoring with Nexfin does not sufficiently replace invasive measurements in critically ill patients. Br J Anaesth 111 (2013), 178–184.
    • (2013) Br J Anaesth , vol.111 , pp. 178-184
    • Hohn, A.1    Defosse, J.M.2    Becker, S.3
  • 55
    • 84862782626 scopus 로고    scopus 로고
    • Noninvasive continuous arterial blood pressure monitoring with Nexfin(R)
    • [55] Martina, J.R., Westerhof, B.E., van Goudoever, J., et al. Noninvasive continuous arterial blood pressure monitoring with Nexfin(R). Anesthesiology 116 (2012), 1092–1103.
    • (2012) Anesthesiology , vol.116 , pp. 1092-1103
    • Martina, J.R.1    Westerhof, B.E.2    van Goudoever, J.3
  • 56
    • 34047190842 scopus 로고    scopus 로고
    • American National Standard for Electronic or Automated Sphygmomanometers
    • AAMI Arlington
    • [56] Sphygmomanometers ANSfEoA, American National Standard for Electronic or Automated Sphygmomanometers. 2002, AAMI, Arlington.
    • (2002)
  • 57
    • 0034869820 scopus 로고    scopus 로고
    • A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients
    • [57] Jansen, J.R., Schreuder, J.J., Mulier, J.P., et al. A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients. Br J Anaesth 87 (2001), 212–222.
    • (2001) Br J Anaesth , vol.87 , pp. 212-222
    • Jansen, J.R.1    Schreuder, J.J.2    Mulier, J.P.3
  • 58
    • 0005928630 scopus 로고    scopus 로고
    • Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress
    • [58] Harms, M.P., Wesseling, K.H., Pott, F., et al. Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress. Clin Sci (Lond) 97 (1999), 291–301.
    • (1999) Clin Sci (Lond) , vol.97 , pp. 291-301
    • Harms, M.P.1    Wesseling, K.H.2    Pott, F.3
  • 59
    • 0032942194 scopus 로고    scopus 로고
    • Continuous cardiac output in septic shock by simulating a model of the aortic input impedance: a comparison with bolus injection thermodilution
    • [59] Jellema, W.T., Wesseling, K.H., Groeneveld, A.B., et al. Continuous cardiac output in septic shock by simulating a model of the aortic input impedance: a comparison with bolus injection thermodilution. Anesthesiology 90 (1999), 1317–1328.
    • (1999) Anesthesiology , vol.90 , pp. 1317-1328
    • Jellema, W.T.1    Wesseling, K.H.2    Groeneveld, A.B.3
  • 60
    • 84858342283 scopus 로고    scopus 로고
    • A comparison of the Nexfin(R) and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery
    • [60] Broch, O., Renner, J., Gruenewald, M., et al. A comparison of the Nexfin(R) and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery. Anaesthesia 67 (2012), 377–383.
    • (2012) Anaesthesia , vol.67 , pp. 377-383
    • Broch, O.1    Renner, J.2    Gruenewald, M.3
  • 61
    • 84861144517 scopus 로고    scopus 로고
    • Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal Doppler
    • [61] Chen, G., Meng, L., Alexander, B., et al. Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal Doppler. J Clin Anesth 24 (2012), 275–283.
    • (2012) J Clin Anesth , vol.24 , pp. 275-283
    • Chen, G.1    Meng, L.2    Alexander, B.3
  • 62
    • 84867900309 scopus 로고    scopus 로고
    • The estimation of cardiac output by the Nexfin device is of poor reliability for tracking the effects of a fluid challenge
    • [62] Monnet, X., Picard, F., Lidzborski, E., et al. The estimation of cardiac output by the Nexfin device is of poor reliability for tracking the effects of a fluid challenge. Crit Care, 16, 2012, R212.
    • (2012) Crit Care , vol.16 , pp. R212
    • Monnet, X.1    Picard, F.2    Lidzborski, E.3
  • 63
    • 84881370424 scopus 로고    scopus 로고
    • Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output
    • [63] Bubenek-Turconi, S.I., Craciun, M., Miclea, I., et al. Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output. Anesth Analg 117 (2013), 366–372.
    • (2013) Anesth Analg , vol.117 , pp. 366-372
    • Bubenek-Turconi, S.I.1    Craciun, M.2    Miclea, I.3
  • 64
    • 84856303645 scopus 로고    scopus 로고
    • Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement
    • [64] Ilies, C., Bauer, M., Berg, P., et al. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement. Br J Anaesth 108 (2012), 202–210.
    • (2012) Br J Anaesth , vol.108 , pp. 202-210
    • Ilies, C.1    Bauer, M.2    Berg, P.3
  • 65
    • 84927744364 scopus 로고    scopus 로고
    • Comparison of a continuous noninvasive arterial pressure device with invasive measurements in cardiovascular postsurgical intensive care patients: a prospective observational study
    • [65] Ilies, C., Grudev, G., Hedderich, J., et al. Comparison of a continuous noninvasive arterial pressure device with invasive measurements in cardiovascular postsurgical intensive care patients: a prospective observational study. Eur J Anaesthesiol 32 (2015), 20–28.
    • (2015) Eur J Anaesthesiol , vol.32 , pp. 20-28
    • Ilies, C.1    Grudev, G.2    Hedderich, J.3
  • 66
    • 84865264710 scopus 로고    scopus 로고
    • Detection of hypotension during Caesarean section with continuous non-invasive arterial pressure device or intermittent oscillometric arterial pressure measurement
    • [66] Ilies, C., Kiskalt, H., Siedenhans, D., et al. Detection of hypotension during Caesarean section with continuous non-invasive arterial pressure device or intermittent oscillometric arterial pressure measurement. Br J Anaesth 109 (2012), 413–419.
    • (2012) Br J Anaesth , vol.109 , pp. 413-419
    • Ilies, C.1    Kiskalt, H.2    Siedenhans, D.3
  • 67
    • 77956019814 scopus 로고    scopus 로고
    • Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia
    • [67] Jeleazcov, C., Krajinovic, L., Munster, T., et al. Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia. Br J Anaesth 105 (2010), 264–272.
    • (2010) Br J Anaesth , vol.105 , pp. 264-272
    • Jeleazcov, C.1    Krajinovic, L.2    Munster, T.3
  • 68
    • 79957736830 scopus 로고    scopus 로고
    • Assessment of trending ability of cardiac output monitors by polar plot methodology
    • [68] Critchley, L.A., Yang, X.X., Lee, A., Assessment of trending ability of cardiac output monitors by polar plot methodology. J Cardiothorac Vasc Anesth 25 (2011), 536–546.
    • (2011) J Cardiothorac Vasc Anesth , vol.25 , pp. 536-546
    • Critchley, L.A.1    Yang, X.X.2    Lee, A.3
  • 69
    • 84948720097 scopus 로고    scopus 로고
    • The accuracy of the CNAP(R) device compared with invasive radial artery measurements for providing continuous noninvasive arterial blood pressure readings at a medical intensive care unit: a method-comparison study
    • [69] Smolle, K.H., Schmid, M., Prettenthaler, H., et al. The accuracy of the CNAP(R) device compared with invasive radial artery measurements for providing continuous noninvasive arterial blood pressure readings at a medical intensive care unit: a method-comparison study. Anesth Analg 121 (2015), 1508–1516.
    • (2015) Anesth Analg , vol.121 , pp. 1508-1516
    • Smolle, K.H.1    Schmid, M.2    Prettenthaler, H.3
  • 70
    • 84922338379 scopus 로고    scopus 로고
    • Continuous non-invasive monitoring improves blood pressure stability in upright position: randomized controlled trial
    • [70] Benes, J., Simanova, A., Tovarnicka, T., et al. Continuous non-invasive monitoring improves blood pressure stability in upright position: randomized controlled trial. J Clin Monit Comput 29 (2015), 11–17.
    • (2015) J Clin Monit Comput , vol.29 , pp. 11-17
    • Benes, J.1    Simanova, A.2    Tovarnicka, T.3
  • 71
    • 34547132055 scopus 로고    scopus 로고
    • Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance
    • [71] Keren, H., Burkhoff, D., Squara, P., Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am J Physiol Heart Circ Physiol 293 (2007), H583–H589.
    • (2007) Am J Physiol Heart Circ Physiol , vol.293 , pp. H583-H589
    • Keren, H.1    Burkhoff, D.2    Squara, P.3
  • 72
    • 41949125848 scopus 로고    scopus 로고
    • Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique
    • [72] Raval, N.Y., Squara, P., Cleman, M., et al. Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique. J Clin Monit Comput 22 (2008), 113–119.
    • (2008) J Clin Monit Comput , vol.22 , pp. 113-119
    • Raval, N.Y.1    Squara, P.2    Cleman, M.3
  • 73
    • 84880165176 scopus 로고    scopus 로고
    • Noninvasive cardiac output measurements in patients with pulmonary hypertension
    • [73] Rich, J.D., Archer, S.L., Rich, S., Noninvasive cardiac output measurements in patients with pulmonary hypertension. Eur Respir J 42 (2013), 125–133.
    • (2013) Eur Respir J , vol.42 , pp. 125-133
    • Rich, J.D.1    Archer, S.L.2    Rich, S.3
  • 74
    • 34447131664 scopus 로고    scopus 로고
    • Noninvasive cardiac output monitoring (NICOM): a clinical validation
    • [74] Squara, P., Denjean, D., Estagnasie, P., et al. Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med 33 (2007), 1191–1194.
    • (2007) Intensive Care Med , vol.33 , pp. 1191-1194
    • Squara, P.1    Denjean, D.2    Estagnasie, P.3
  • 75
    • 79953674181 scopus 로고    scopus 로고
    • Measurement of cardiac output in children by bioreactance
    • [75] Ballestero, Y., Lopez-Herce, J., Urbano, J., et al. Measurement of cardiac output in children by bioreactance. Pediatr Cardiol 32 (2011), 469–472.
    • (2011) Pediatr Cardiol , vol.32 , pp. 469-472
    • Ballestero, Y.1    Lopez-Herce, J.2    Urbano, J.3
  • 76
    • 84869162516 scopus 로고    scopus 로고
    • Cardiac output measurements using the bioreactance technique in critically ill patients
    • [76] Fagnoul, D., Vincent, J.L., Backer de, D., Cardiac output measurements using the bioreactance technique in critically ill patients. Crit Care, 16, 2012, 460.
    • (2012) Crit Care , vol.16 , pp. 460
    • Fagnoul, D.1    Vincent, J.L.2    Backer de, D.3
  • 77
    • 20944444823 scopus 로고    scopus 로고
    • A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors
    • [77] Ishihara, H., Okawa, H., Tanabe, K., et al. A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors. J Clin Monit Comput 18 (2004), 313–320.
    • (2004) J Clin Monit Comput , vol.18 , pp. 313-320
    • Ishihara, H.1    Okawa, H.2    Tanabe, K.3
  • 78
    • 78650835760 scopus 로고    scopus 로고
    • A novel continuous cardiac output monitor based on pulse wave transit time
    • [78] Sugo, Y., Ukawa, T., Takeda, S., et al. A novel continuous cardiac output monitor based on pulse wave transit time. Conf Proc IEEE Eng Med Biol Soc 2010 (2010), 2853–2856.
    • (2010) Conf Proc IEEE Eng Med Biol Soc , vol.2010 , pp. 2853-2856
    • Sugo, Y.1    Ukawa, T.2    Takeda, S.3
  • 79
    • 84877106251 scopus 로고    scopus 로고
    • The ability of a new continuous cardiac output monitor to measure trends in cardiac output following implementation of a patient information calibration and an automated exclusion algorithm
    • [79] Ishihara, H., Sugo, Y., Tsutsui, M., et al. The ability of a new continuous cardiac output monitor to measure trends in cardiac output following implementation of a patient information calibration and an automated exclusion algorithm. J Clin Monit Comput 26 (2012), 465–471.
    • (2012) J Clin Monit Comput , vol.26 , pp. 465-471
    • Ishihara, H.1    Sugo, Y.2    Tsutsui, M.3
  • 80
    • 84869386502 scopus 로고    scopus 로고
    • Comparison of esCCO and transthoracic echocardiography for non-invasive measurement of cardiac output intensive care
    • [80] Bataille, B., Bertuit, M., Mora, M., et al. Comparison of esCCO and transthoracic echocardiography for non-invasive measurement of cardiac output intensive care. Br J Anaesth 109 (2012), 879–886.
    • (2012) Br J Anaesth , vol.109 , pp. 879-886
    • Bataille, B.1    Bertuit, M.2    Mora, M.3
  • 81
    • 33745697192 scopus 로고    scopus 로고
    • Transoesophageal echocardiography (TOE) in the operating room
    • [81] Kneeshaw, J.D., Transoesophageal echocardiography (TOE) in the operating room. Br J Anaesth 97 (2006), 77–84.
    • (2006) Br J Anaesth , vol.97 , pp. 77-84
    • Kneeshaw, J.D.1
  • 82
    • 0042415684 scopus 로고    scopus 로고
    • ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography–summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASE Committee to Update the 1997 Guidelines for the Clinical Application of Echocardiography)
    • [82] Cheitlin, M.D., Armstrong, W.F., Aurigemma, G.P., et al. ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography–summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASE Committee to Update the 1997 Guidelines for the Clinical Application of Echocardiography). J Am Coll Cardiol 42 (2003), 954–970.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 954-970
    • Cheitlin, M.D.1    Armstrong, W.F.2    Aurigemma, G.P.3
  • 83
    • 0030053416 scopus 로고    scopus 로고
    • Transgastric, pulsed Doppler echocardiographic determination of cardiac output
    • [83] Descorps-Declere, A., Smail, N., Vigue, B., et al. Transgastric, pulsed Doppler echocardiographic determination of cardiac output. Intensive Care Med 22 (1996), 34–38.
    • (1996) Intensive Care Med , vol.22 , pp. 34-38
    • Descorps-Declere, A.1    Smail, N.2    Vigue, B.3
  • 84
    • 0345131662 scopus 로고    scopus 로고
    • Intraoperative determination of cardiac output using multiplane transesophageal echocardiography: a comparison to thermodilution
    • [84] Perrino, A.C. Jr., Harris, S.N., Luther, M.A., Intraoperative determination of cardiac output using multiplane transesophageal echocardiography: a comparison to thermodilution. Anesthesiology 89 (1998), 350–357.
    • (1998) Anesthesiology , vol.89 , pp. 350-357
    • Perrino, A.C.1    Harris, S.N.2    Luther, M.A.3
  • 85
    • 84929741503 scopus 로고    scopus 로고
    • Focused intraoperative transthoracic echocardiography by anesthesiologists: a feasibility study
    • [85] Kratz, T., Campo Dell'Orto, M., Exner, M., et al. Focused intraoperative transthoracic echocardiography by anesthesiologists: a feasibility study. Minerva Anestesiol 81 (2015), 490–496.
    • (2015) Minerva Anestesiol , vol.81 , pp. 490-496
    • Kratz, T.1    Campo Dell'Orto, M.2    Exner, M.3
  • 86
    • 42449084898 scopus 로고    scopus 로고
    • What type of monitoring has been shown to improve outcomes in acutely ill patients?
    • [86] Ospina-Tascon, G.A., Cordioli, R.L., Vincent, J.L., What type of monitoring has been shown to improve outcomes in acutely ill patients?. Intensive Care Med 34 (2008), 800–820.
    • (2008) Intensive Care Med , vol.34 , pp. 800-820
    • Ospina-Tascon, G.A.1    Cordioli, R.L.2    Vincent, J.L.3
  • 87
    • 84901807828 scopus 로고    scopus 로고
    • Effect of a perioperative, cardiac output-guided hemodynamic therapy algorithm on outcomes following major gastrointestinal surgery: a randomized clinical trial and systematic review
    • [87] Pearse, R.M., Harrison, D.A., MacDonald, N., et al. Effect of a perioperative, cardiac output-guided hemodynamic therapy algorithm on outcomes following major gastrointestinal surgery: a randomized clinical trial and systematic review. JAMA 311 (2014), 2181–2190.
    • (2014) JAMA , vol.311 , pp. 2181-2190
    • Pearse, R.M.1    Harrison, D.A.2    MacDonald, N.3
  • 88
    • 84902174639 scopus 로고    scopus 로고
    • A review of intraoperative goal-directed therapy using arterial waveform analysis for assessment of cardiac output
    • [88] Mehta, N., Fernandez-Bustamante, A., Seres, T., A review of intraoperative goal-directed therapy using arterial waveform analysis for assessment of cardiac output. Sci World J, 2014, 2014, 702964.
    • (2014) Sci World J , vol.2014 , pp. 702964
    • Mehta, N.1    Fernandez-Bustamante, A.2    Seres, T.3
  • 89
    • 84878317998 scopus 로고    scopus 로고
    • Effectiveness of non-cardiac preoperative testing in non-cardiac elective surgery: a systematic review
    • [89] Johansson, T., Fritsch, G., Flamm, M., et al. Effectiveness of non-cardiac preoperative testing in non-cardiac elective surgery: a systematic review. Br J Anaesth 110 (2013), 926–939.
    • (2013) Br J Anaesth , vol.110 , pp. 926-939
    • Johansson, T.1    Fritsch, G.2    Flamm, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.