메뉴 건너뛰기




Volumn 16, Issue 6, 2012, Pages

Cardiac output measurements using the bioreactance technique in critically ill patients

Author keywords

[No Author keywords available]

Indexed keywords

HYPERTENSIVE FACTOR; INOTROPIC AGENT;

EID: 84869162516     PISSN: 13648535     EISSN: 1466609X     Source Type: Journal    
DOI: 10.1186/cc11481     Document Type: Letter
Times cited : (45)

References (4)
  • 1
    • 34447131664 scopus 로고    scopus 로고
    • Noninvasive cardiac output monitoring (NICOM): a clinical validation
    • 10.1007/s00134-007-0640-0, 17458538
    • Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C. Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med 2007, 33:1191-1194. 10.1007/s00134-007-0640-0, 17458538.
    • (2007) Intensive Care Med , vol.33 , pp. 1191-1194
    • Squara, P.1    Denjean, D.2    Estagnasie, P.3    Brusset, A.4    Dib, J.C.5    Dubois, C.6
  • 2
    • 67249088798 scopus 로고    scopus 로고
    • Comparison between Flotrac-Vigileo and bioreactance, a totally noninvasive method for cardiac output monitoring
    • 10.1186/cc7884, 2717435, 19454009
    • Marque S, Cariou A, Chiche JD, Squara P. Comparison between Flotrac-Vigileo and bioreactance, a totally noninvasive method for cardiac output monitoring. Crit Care 2009, 13:R73. 10.1186/cc7884, 2717435, 19454009.
    • (2009) Crit Care , vol.13
    • Marque, S.1    Cariou, A.2    Chiche, J.D.3    Squara, P.4
  • 3
    • 41949125848 scopus 로고    scopus 로고
    • Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique
    • 10.1007/s10877-008-9112-5, 18340540
    • Raval NY, Squara P, Cleman M, Yalamanchili K, Winklmaier M, Burkhoff D. Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique. J Clin Monit Comput 2008, 22:113-119. 10.1007/s10877-008-9112-5, 18340540.
    • (2008) J Clin Monit Comput , vol.22 , pp. 113-119
    • Raval, N.Y.1    Squara, P.2    Cleman, M.3    Yalamanchili, K.4    Winklmaier, M.5    Burkhoff, D.6
  • 4
    • 78650415602 scopus 로고    scopus 로고
    • Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test
    • 10.1007/s00134-010-1990-6, 20665001
    • Benomar B, Ouattara A, Estagnasie P, Brusset A, Squara P. Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test. Intensive Care Med 2010, 36:1875-1881. 10.1007/s00134-010-1990-6, 20665001.
    • (2010) Intensive Care Med , vol.36 , pp. 1875-1881
    • Benomar, B.1    Ouattara, A.2    Estagnasie, P.3    Brusset, A.4    Squara, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.